Med Biol Eng Comput ; 43(5): 552-6, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16411626

RESUMO

The paper describes the design, technical characteristics and first results of an adjustable staircase with commercial force plates embedded in the steps and custom force transducers as part of the handrail supports. For the railing assembly, the greatest errors (< 10% of maximum signal) and cross-talk range (0.58-6.74%) were in the medial-lateral direction and were corrected using a calibration matrix. Power spectral density analyses showed free vibration frequency responses for both the railing (15 Hz) and steps (38.6 Hz) that were relatively distinct from lower applied forces recorded during stair ascent. The creation of standardised filtering protocols was therefore possible to provide step reaction force signals identical to the literature and examples of upper-limb reaction forces that have not been shown before. Such a staircase will allow a more complete study of full body contributions to stair walking across various subject populations.


Assuntos
Marcha/fisiologia , Extremidade Inferior/fisiologia , Extremidade Superior/fisiologia , Fenômenos Biomecânicos/instrumentação , Desenho de Equipamento , Humanos , Locomoção/fisiologia , Transdutores
2.
Clin Biomech (Bristol, Avon) ; 15(1): 1-8, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10590338

RESUMO

OBJECTIVE: To develop a method to obtain accurate three-dimensional scapular attitudes and to assess their concurrent validity and reliability. STUDY DESIGN: In this methodological study, the three-dimensional scapular attitudes were calculated in degrees, using a rotation matrix (cyclic Cardanic sequence), from spatial coordinates obtained with the probing of three non colinear landmarks first on an anatomical model and second on a healthy subject. BACKGROUND: Although abnormal movement of the scapula is related to shoulder impingement syndrome, it is not clearly understood whether or not scapular motion impairment is a predisposing factor. Characterization of three-dimensional scapular attitudes in planes and at joint angles for which sub-acromial impingement is more likely to occur is not known. METHODS: The Optotrak probing system was used. An anatomical model of the scapula was built and allowed us to impose scapular attitudes of known direction and magnitude. A local coordinate reference system was defined with three non colinear anatomical landmarks to assess accuracy and concurrent validity of the probing method with fixed markers. Axial rotation angles were calculated from a rotation matrix using a cyclic Cardanic sequence of rotations. The same three non colinear body landmarks were digitized on one healthy subject and the three dimensional scapular attitudes obtained were compared between sessions in order to assess the reliability. RESULTS AND CONCLUSIONS: The measure of three dimensional scapular attitudes calculated from data using the Optotrak probing system was accurate with means of the differences between imposed and calculated rotation angles ranging from 1.5 degrees to 4.2 degrees. Greatest variations were observed around the third axis of the Cardanic sequence associated with posterior-anterior transverse rotations. The mean difference between the Optotrak probing system method and fixed markers was 1.73 degrees showing a good concurrent validity. Differences between the two methods were generally very low for one and two direction displacements and the largest discrepancies were observed for imposed displacements combining movement about the three axes. The between sessions variation of three dimensional scapular attitudes was less than 10% for most of the arm positions adopted by a healthy subject suggesting a good reliability. The Optotrak probing system used with a standardized protocol lead to accurate, valid and reliable measures of scapular attitudes. RELEVANCE: Although abnormal range of motion of the scapula is often related to shoulder pathologies, reliable outcome measures to quantify three-dimensional scapular motion on subjects are not available. It is important to establish a standardized protocol to characterize three-dimensional scapular motion on subjects using a method for which the accuracy and validity are known. The method used in the present study has provided such a protocol and will now allow to verify to what extent, scapular motion impairment is linked to the development of specific shoulder pathologies.


Assuntos
Processamento de Imagem Assistida por Computador/instrumentação , Escápula/anatomia & histologia , Escápula/fisiologia , Fenômenos Biomecânicos , Humanos , Modelos Anatômicos , Amplitude de Movimento Articular/fisiologia , Reprodutibilidade dos Testes , Rotação , Estatísticas não Paramétricas