Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Breath Res ; 13(2): 021001, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30523983

RESUMO

BACKGROUND: The aetiology of lower respiratory tract infections is challenging to investigate. Despite the wide array of diagnostic tools, invasive techniques, such as bronchoalveolar lavage (BAL), are often required to obtain adequate specimens. PneumoniaCheckTM is a new device that collects aerosol particles from cough, allowing microbiological analyses. Up to now it has been tested only for bacteria detection, but no study has investigated its usefulness for virus identification. METHODS: In this pilot study we included 12 consecutive patients with pneumonia. After testing cough adequacy via a peak flow meter, a sampling with PneumoniaCheckTM was collected and a BAL was performed in each patient. Microbiological analyses for virus identification were performed on each sample and concordance between the two techniques was tested (sensitivity, specificity and positive/negative predictive values), taking BAL results as reference. RESULTS: BAL was considered adequate in 10 patients. Among them, a viral pathogen was identified by PneumoniaCheckTM 6 times, each on different samples, whereas BAL allowed to detect the presence of a virus on 7 patients (14 positivities). Overall, the specificity for PneumoniaCheckTM to detect a virus was 100%, whereas the sensitivity was 66%. When considering only herpes viruses, PneumoniaCheckTM showed a lower sensitivity, detecting a virus in 1/4 of infected patients (25%). CONCLUSIONS: In this pilot study PneumoniaCheckTM showed a good correlation with BAL for non-herpes virologic identification in pneumonia patients, providing excellent specificity. Further studies on larger population are needed to confirm these results and define its place in the panorama of rapid diagnostic tests for lower respiratory tract infections.


Assuntos
Aerossóis/análise , Tosse/diagnóstico , Pneumonia Associada a Assistência à Saúde/diagnóstico , Adulto , Idoso , Líquido da Lavagem Broncoalveolar/virologia , Feminino , Pneumonia Associada a Assistência à Saúde/virologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Adulto Jovem
2.
Minerva Med ; 109(3): 239-247, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29458243

RESUMO

Mild-to-moderate hemoptysis is defined as the expectoration of blood or blood-streaked sputum originating from the lower respiratory tract, in volumes that do not immediately threaten the patient's life. Nevertheless, it is a very common respiratory symptom and the list of underlying respiratory or non-respiratory diseases is vast, ranging from the most worrying to more easily manageable etiologies. In this narrative review, we have analyzed the most recent recommendations inferred from the literature, in terms of diagnostic as well as therapeutic approach.


Assuntos
Hemoptise/diagnóstico , Hemoptise/terapia , Humanos , Guias de Prática Clínica como Assunto , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA