1.
N Engl J Med ; 383(15): 1447-1457, 2020 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-32865376

RESUMO

BACKGROUND: The effect of single as compared with dual antiplatelet treatment on bleeding and thromboembolic events after transcatheter aortic-valve implantation (TAVI) in patients who do not have an indication for long-term anticoagulation has not been well studied. METHODS: In a randomized, controlled trial, we assigned a subgroup of patients who were undergoing TAVI and did not have an indication for long-term anticoagulation, in a 1:1 ratio, to receive aspirin alone or aspirin plus clopidogrel for 3 months. The two primary outcomes were all bleeding (including minor, major, and life-threatening or disabling bleeding) and non-procedure-related bleeding over a period of 12 months. Most bleeding at the TAVI puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2) at 1 year, with both outcomes tested sequentially for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: A total of 331 patients were assigned to receive aspirin alone and 334 were assigned to receive aspirin plus clopidogrel. A bleeding event occurred in 50 patients (15.1%) receiving aspirin alone and in 89 (26.6%) receiving aspirin plus clopidogrel (risk ratio, 0.57; 95% confidence interval [CI], 0.42 to 0.77; P = 0.001). Non-procedure-related bleeding occurred in 50 patients (15.1%) and 83 patients (24.9%), respectively (risk ratio, 0.61; 95% CI, 0.44 to 0.83; P = 0.005). A secondary composite 1 event occurred in 76 patients (23.0%) receiving aspirin alone and in 104 (31.1%) receiving aspirin plus clopidogrel (difference, -8.2 percentage points; 95% CI for noninferiority, -14.9 to -1.5; P<0.001; risk ratio, 0.74; 95% CI for superiority, 0.57 to 0.95; P = 0.04). A secondary composite 2 event occurred in 32 patients (9.7%) and 33 patients (9.9%), respectively (difference, -0.2 percentage points; 95% CI for noninferiority, -4.7 to 4.3; P = 0.004; risk ratio, 0.98; 95% CI for superiority, 0.62 to 1.55; P = 0.93). A total of 44 patients (13.3%) and 32 (9.6%), respectively, received oral anticoagulation during the trial. CONCLUSIONS: Among patients undergoing TAVI who did not have an indication for oral anticoagulation, the incidence of bleeding and the composite of bleeding or thromboembolic events at 1 year were significantly less frequent with aspirin than with aspirin plus clopidogrel administered for 3 months. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Assuntos
Aspirina/uso terapêutico , Clopidogrel/uso terapêutico , Hemorragia/induzido quimicamente , Inibidores da Agregação Plaquetária/uso terapêutico , Trombose/prevenção & controle , Substituição da Valva Aórtica Transcateter , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Aspirina/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Quimioterapia Combinada , Feminino , Hemorragia/epidemiologia , Humanos , Incidência , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Período Pós-Operatório , Trombose/epidemiologia
2.
N Engl J Med ; 382(18): 1696-1707, 2020 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-32223116

RESUMO

BACKGROUND: The roles of anticoagulation alone or with an antiplatelet agent after transcatheter aortic-valve implantation (TAVI) have not been well studied. METHODS: We performed a randomized trial of clopidogrel in patients undergoing TAVI who were receiving oral anticoagulation for appropriate indications. Patients were assigned before TAVI in a 1:1 ratio not to receive clopidogrel or to receive clopidogrel for 3 months. The two primary outcomes were all bleeding and non-procedure-related bleeding over a period of 12 months. Procedure-related bleeding was defined as Bleeding Academic Research Consortium type 4 severe bleeding, and therefore most bleeding at the puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction at 12 months (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2), both tested for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: Bleeding occurred in 34 of the 157 patients (21.7%) receiving oral anticoagulation alone and in 54 of the 156 (34.6%) receiving oral anticoagulation plus clopidogrel (risk ratio, 0.63; 95% confidence interval [CI], 0.43 to 0.90; P = 0.01); most bleeding events were at the TAVI access site. Non-procedure-related bleeding occurred in 34 patients (21.7%) and in 53 (34.0%), respectively (risk ratio, 0.64; 95% CI, 0.44 to 0.92; P = 0.02). Most bleeding occurred in the first month and was minor. A secondary composite 1 event occurred in 49 patients (31.2%) receiving oral anticoagulation alone and in 71 (45.5%) receiving oral anticoagulation plus clopidogrel (difference, -14.3 percentage points; 95% CI for noninferiority, -25.0 to -3.6; risk ratio, 0.69; 95% CI for superiority, 0.51 to 0.92). A secondary composite 2 event occurred in 21 patients (13.4%) and in 27 (17.3%), respectively (difference, -3.9 percentage points; 95% CI for noninferiority, -11.9 to 4.0; risk ratio, 0.77; 95% CI for superiority, 0.46 to 1.31). CONCLUSIONS: In patients undergoing TAVI who were receiving oral anticoagulation, the incidence of serious bleeding over a period of 1 month or 1 year was lower with oral anticoagulation alone than with oral anticoagulation plus clopidogrel. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Assuntos
Anticoagulantes/uso terapêutico , Clopidogrel/uso terapêutico , Hemorragia/induzido quimicamente , Inibidores da Agregação Plaquetária/uso terapêutico , Substituição da Valva Aórtica Transcateter , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Quimioterapia Combinada , Hemorragia/epidemiologia , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos
3.
Catheter Cardiovasc Interv ; 101(3): 505-510, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36651339

RESUMO

OBJECTIVE: The elevated risk of adverse events following percutaneous coronary intervention in diabetic patients persists with newer-generation DES. The polymer-free amphilimus-eluting stent (PF-AES) possesses characteristics with a potentially enhanced performance in patients with diabetes. Data from the 1-year follow-up period has been previously published. The aim of this subanalysis was to assess long-term performance of two contemporary drug-eluting stents (DES) in a diabetic population. METHODS: In the ReCre8 trial, patients were stratified for diabetes and troponin status, and randomized to implantation of a permanent polymer zotarolimus-eluting stent (PP-ZES) or PF-AES. The primary endpoint was target-lesion failure (TLF), a composite of cardiac death, target-vessel myocardial infarction and target-lesion revascularization. Clinical outcomes between discharge and 3 years follow-up were assessed. RESULTS: A total of 302 patients with diabetes were included in this analysis. After 3 years, TLF occurred in 12.5% of PP-ZES patients versus 10.0% in PF-AES patients (p = 0.46). Similarly, the separate components of TLF were comparable between the two study arms. The secondary composite endpoint of NACE was higher in the PP-ZES arm with 45 cases (29.6%) versus 30 cases (20.0%) in the PF-AES arm (p = 0.036). In the insulin-dependent diabetic population, TLF occurred in 19.1% of PP-ZES patients versus 10.4% of PF-AES patients (p = 0.21). NACE occurred in 40.4% of PP-ZES patients versus 27.1% of PF-AES patients (p = 0.10). CONCLUSIONS: This subanalysis shows that the use of PF-AES results in similar clinical outcomes as compared to PP-ZES, yet some benefits of use of PF-AES in diabetic patients may prevail. Future dedicated trials should confirm these findings.


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/induzido quimicamente , Seguimentos , Fatores de Risco , Resultado do Tratamento , Diabetes Mellitus/diagnóstico , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fármacos Cardiovasculares/efeitos adversos
4.
Catheter Cardiovasc Interv ; 102(2): 273-280, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37221985

RESUMO

BACKGROUND: NobleStitch EL is a novel suture-based technique used for patent foramen ovale (PFO) closure and an alternative to traditional double-disc devices without the need for antithrombotic therapy. However, successful closure rates are still unknown, and certain anatomies may be unfavorable for successful closure. AIMS: We assessed the efficacy of the NobleStitch EL and sought to identify patient-related anatomical features associated with successful suture-based closure. METHODS: We included 55 patients who underwent PFO closure with the NobleStitch EL in The Netherlands and Switzerland. Successful closure was defined as residual right-to-left shunt grade ≤1 with Valsalva maneuver at a cardiac ultrasound. Predefined possible anatomical determinants for effective closure included PFO length, atrial septal aneurysm, PFO entry- and exit diameter. RESULTS: Successful closure was achieved in 33 patients (60%). The PFO length was shorter in patients with successful closure compared to unsuccessful closure with a median length of 9.6 mm (IQR 8.0-15.0) versus 13.3 mm (IQR 11.4-18.6) on preprocedural ultrasound (p = 0.041) and 9.9 mm (IQR 8.0-13.1) versus 12.5 mm (IQR 9.7-15.4) on angiography (p = 0.049). Additionally, the PFO exit diameter and PFO volume were smaller in patients with successful closure than unsuccessful closure, with a mean diameter of 7.0 ± 3.1 mm versus 9.5 ± 3.8 mm (p = 0.015) and a median volume of 381 mm3 (IQR 286-894) versus 985 mm3 (IQR 572-1550) (p = 0.016). CONCLUSION: In our study cohort, the successful PFO closure rate using NobleStitch EL was relatively low (60%). With this alternative procedure, patients with a small PFO driven by a short PFO tunnel length and small exit diameter seem to be eligible for successful suture-based closure.


Assuntos
Forame Oval Patente , Acidente Vascular Cerebral , Humanos , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Forame Oval Patente/complicações , Resultado do Tratamento , Ecocardiografia Transesofagiana , Cateterismo Cardíaco , Suturas
5.
Catheter Cardiovasc Interv ; 101(6): 1134-1143, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37036268

RESUMO

OBJECTIVE: To determine the prognostic impact of coronary artery disease (CAD) in patients randomized to bivalirudin or unfractionated heparin (UFH) during transcatheter aortic valve replacement (TAVR). BACKGROUND: CAD is a common comorbidity among patients undergoing TAVR and studies provide conflicting data on its prognostic impact. METHODS: The Bivalirudin on Aortic Valve Intervention Outcomes-3 (BRAVO-3) randomized trial compared the use of bivalirudin versus UFH in 802 high-surgical risk patients undergoing transfemoral TAVR for severe symptomatic aortic stenosis. Patients were stratified according to the presence or absence of history of CAD as well as periprocedural anticoagulation. The coprimary endpoints were net adverse cardiac events (NACE; a composite of all-cause mortality, myocardial infarction, stroke, or major bleeding) and major Bleeding Academic Research Consortium (BARC) bleeding ≥3b at 30 days postprocedure. RESULTS: Among 801 patients, 437 (54.6%) had history of CAD of whom 223 (51.0%) received bivalirudin. There were no significant differences in NACE (adjusted odds ratio [OR]: 1.04; 95% confidence interval [CI]: 0.69-1.58) or BARC ≥ 3b bleeding (adjusted OR: 0.84; 95% CI: 0.51-1.39) in patients with vs without CAD at 30 days. Among CAD patients, periprocedural use of bivalirudin was associated with similar NACE (OR: 0.80; 95% CI: 0.47-1.35) and BARC ≥ 3b bleeding (OR: 0.64; 95% CI: 0.33-1.25) compared with UFH, irrespective of history of CAD (p-interaction = 0.959 for NACE; p-interaction = 0.479 for major bleeding). CONCLUSION: CAD was not associated with a higher short-term risk of NACE or major bleeding after TAVR. Periprocedural anticoagulation with bivalirudin did not show any advantage over UFH in patients with and without CAD.


Assuntos
Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Humanos , Heparina/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Antitrombinas/efeitos adversos , Resultado do Tratamento , Hirudinas/efeitos adversos , Hemorragia/induzido quimicamente , Fragmentos de Peptídeos/efeitos adversos , Proteínas Recombinantes/efeitos adversos
6.
Catheter Cardiovasc Interv ; 100(3): 439-448, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35830708

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective alternative to surgical aortic valve replacement for patients who are at increased surgical risk. Consequently, frailty is common in patients undergoing TAVR. OBJECTIVES: This study aims to investigate the impact of frailty on outcomes following TAVR. METHODS: A retrospective cohort study was conducted, including all TAVR candidates who visited the geriatric outpatient clinic for preoperative screening. Frailty status was assessed according to the Groningen Frailty Indicator. The primary outcome of the study was defined as the occurrence of postoperative complications, and this was evaluated according to the Clavien-Dindo classification. An additional analysis was performed to assess the impact of frailty on 1-year all-cause mortality and complications within 30 days of TAVR according to the Valve Academic Research Consortium (VARC-2) criteria. The VARC-2 criteria provide harmonized endpoint definitions for TAVR studies. RESULTS: In total, 431 patients with a mean age of 80.8 ± 6.2 years were included, of whom 56% were female. Frailty was present in 36% of the participants. Frailty was associated with a higher risk of the composite outcome of complications [adjusted odds ratio (OR): 1.55 (95% confidence interval, CI: 1.03-2.34)], 30-day mortality [adjusted OR: 4.84 (95% CI: 1.62-14.49)], 3-month mortality [adjusted OR: 2.52 (95% CI: 1.00-6.28)] and 1-year mortality [adjusted OR: 2.96 (95% CI: 1.46-6.00)]. CONCLUSIONS: Frailty is common in TAVR patients and is associated with an increased overall risk of postoperative complications, particularly mortality. Increased optimization of screening and treatment of frailty in the guidelines for valvular heart diseases is recommended.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Fragilidade/complicações , Fragilidade/diagnóstico , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 99(2): 366-372, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33811730

RESUMO

OBJECTIVES: The purpose of this analysis was to compare target-lesion failure (TLF) of a permanent polymer zotarolimus-eluting stent (PP-ZES) versus a polymer-free amphilimus-eluting stent (PF-AES) in diabetics. BACKGROUND: The improvement of outcomes with new-generation drug-eluting stent as seen in the general population is less pronounced among diabetics. The PF-AES introduces an elution-technology with potential enhanced performance in diabetics. METHODS: In this subanalysis of the ReCre8 trial, patients were randomized to either a PP-ZES or PF-AES after stratification for diabetes and troponin status. The primary device-oriented endpoint was TLF, a composite of cardiac death, target-vessel myocardial infarction and target-lesion revascularization. RESULTS: In the ReCre8 trial, 304 (20%) patients were diabetic and 96 (6%) had insulin-dependent diabetes mellitus. There was no statistically significant difference between the two study arms regarding the primary endpoint (PP-ZES 7.2% vs. PF-AES 4.0%; p = .21), although the composite of net adverse clinical events was higher in the PP-ZES arm (15.7 vs. 8.0%; p = .035). Stent thrombosis was low in both groups with no cases in the PP-ZES arm and 1 case in the PF-AES arm (p = .32). Regarding insulin-treated diabetics, TLF was higher in the PP-ZES arm (14.9 vs. 2.1%; p = .022). CONCLUSIONS: Diabetics could potentially benefit from a dedicated stent, releasing sirolimus with a lipophilic carrier (amphilimus-formulation). Future trials should confirm the potential benefit of a PF-AES in this population.


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/induzido quimicamente , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Desenho de Prótese , Stents , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 99(3): 664-673, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34582631

RESUMO

OBJECTIVES: to test the safety and efficacy of intravascular imaging and specifically optical coherence tomography (OCT) as a diagnostic tool for left main angioplasty and analyze the mid-term outcome accordingly. BACKGROUND: Clinical data and international guidelines recommend the use of intravascular imaging ultrasound (IVUS) to guide left main (LM) angioplasty. Despite early experience using OCT in this setting is encouraging, the evidence supporting its use is still limited. METHODS: ROCK II is a multicenter, investigator-driven, retrospective European study to compare the performance of IVUS and OCT versus angiography in patients undergoing distal-LM stenting. The primary study endpoint was target-lesion failure (TLF) including cardiac death, target-vessel myocardial infarction and target-lesion revascularization. We designed this study hypothesizing the superiority of intravascular imaging over angiographic guidance alone, and the non-inferiority of OCT versus IVUS. RESULTS: A total of 730 patients, 377 with intravascular-imaging guidance (162 OCT, 215 IVUS) and 353 with angiographic guidance, were analyzed. The one-year rate of TLF was 21.2% with angiography and 12.7% with intravascular-imaging (p = 0.039), with no difference between OCT and IVUS (p = 0.26). Intravascular-imaging was predictor of freedom from TLF (HR 0.46; 95% CI 0.23-0.93: p = 0.03). Propensity-score matching identified three groups of 100 patients each with no significant differences in baseline characteristics. The one-year rate of TLF was 16% in the angiographic, 7% in the OCT and 6% in the IVUS group, respectively (p = 0.03 for IVUS or OCT vs. angiography). No between-group significant differences in the rate of individual components of TLF were found. CONCLUSIONS: Intravascular imaging was superior to angiography for distal LM stenting, with no difference between OCT and IVUS.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos
9.
Heart Vessels ; 37(2): 194-199, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34374824

RESUMO

Coronary sinus Reducer (CSR) implantation is currently recommended to relieve angina in patients with refractory symptoms despite optimal medical therapy and maximally achievable revascularization. The impact of diabetes mellitus on outcome after CSR implantation is at present unknown. We aimed to explore the impact of CSR in refractory angina patients with diabetes mellitus. Data from consecutive patients undergoing CSR implantation at four different centres between 2014 and 2018 were included. Patients were divided according to the presence or absence of diabetes mellitus. Primary objective of this analysis was to evaluate the clinical response to CSR implantation defined as an improvement of ≥ 1 classes of the Canadian Cardiovascular Society (CCS) Classification. A total of 219 patients were included, 116 (53%) of whom had diabetes mellitus. The median age of the population was 69 years and 167 patients (76%) were male. There were no significant differences between groups of patients with and without diabetes mellitus with respect to CCS class at baseline (p value = 0.32) and at follow-up (p = 0.75). Over a median follow-up of 393 [224-1004] days, 84 (72%) of the patients with diabetes mellitus met the primary outcome, similarly to those without diabetes mellitus (p = 0.28). Fifty-three patients (24%) did not have an improvement in CCS class and no one experienced worsening of angina. CSR implantation was equally effective in improving angina symptoms among patients with refractory angina and diabetes mellitus compared to patients without diabetes mellitus.


Assuntos
Seio Coronário , Diabetes Mellitus , Idoso , Angina Pectoris/diagnóstico , Angina Pectoris/etiologia , Angina Pectoris/cirurgia , Canadá , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Diabetes Mellitus/epidemiologia , Humanos , Masculino , Resultado do Tratamento
10.
Eur Heart J ; 42(27): 2670-2679, 2021 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-34000004

RESUMO

AIMS: The REFLECT I trial investigated the safety and effectiveness of the TriGuard™ HDH (TG) cerebral embolic deflection device in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: This prospective, multicentre, single-blind, 2:1 randomized (TG vs. no TG) study aimed to enrol up to 375 patients, including up to 90 roll-in patients. The primary combined safety endpoint (VARC-2 defined early safety) at 30 days was compared with a performance goal. The primary efficacy endpoint was a hierarchical composite of (i) all-cause mortality or any stroke at 30 days, (ii) National Institutes of Health Stroke Scale (NIHSS) worsening at 2-5 days or Montreal Cognitive Assessment worsening at 30 days, and (iii) total volume of cerebral ischaemic lesions detected by diffusion-weighted magnetic resonance imaging at 2-5 days. Cumulative scores were compared between treatment groups using the Finkelstein-Schoenfeld method. A total of 258 of the planned, 375 patients (68.8%) were enrolled (54 roll-in and 204 randomized). The primary safety outcome was met compared with the performance goal (21.8% vs. 35%, P < 0.0001). The primary hierarchical efficacy endpoint was not met (mean efficacy score, higher is better: -5.3 ± 99.8 TG vs. 11.8 ± 96.4 control, P = 0.31). Covert central nervous system injury was numerically lower with TG both in-hospital (46.1% vs. 60.3%, P = 0.0698) and at 5 days (61.7 vs. 76.2%, P = 0.054) compared with controls. CONCLUSION: REFLECT I demonstrated that TG cerebral protection during TAVR was safe in comparison with historical TAVR data but did not meet the predefined effectiveness endpoint compared with unprotected TAVR controls.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Método Simples-Cego , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 97(4): E597-E606, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32886869

RESUMO

OBJECTIVES: To compare the outcomes of transfemoral ACURATE neo (NEO) and Sapien 3 (S3) patients in terms of device success and clinical safety outcomes using a propensity score analysis. BACKGROUND: Differences in clinical outcomes between the latest-generation balloon-expandable S3 and self-expanding NEO in a "real-world transfemoral TAVI population" are still unclear. METHODS: We compared up to 6 months clinical outcomes using a propensity score analysis (inverse probability of treatment weighting [IPTW]) to account for differences in baseline characteristics. RESULTS: A total of 345 patients underwent transfemoral transcatheter aortic valve implantation (TAVI) with either NEO or S3 at two centers in the Netherlands. Composite device success and early safety endpoints were comparable between NEO and S3 (Device success: IPTW-adjusted OR: 0.35 [95% CI: 0.12-1.18], and early safety: IPTW-adjusted OR: 0.51 [95% CI: 0.19-1.38]). Six-months mortality was 5.3 versus 3.6%, stroke was 2.8 versus 3.3%, and pacemaker rate was 6.1 versus 8.6%, respectively with p = NS. Mean aortic gradient was lower in the NEO group (5.72 ± 2.47 vs. 9.05 ± 3.48; p = <.001), with a comparable rate of moderate or severe paravalvular leak (0 versus 2.1%; p = NS). CONCLUSIONS: Device success and clinical safety outcomes were comparable for both valves. Up to 6-months follow-up clinical outcomes and mortality rate remained excellent. Mean aortic gradient was lower after ACURATE neo implantation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Pontuação de Propensão , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 97(7): E929-E935, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33211373

RESUMO

OBJECTIVES: We hypothesized that some coronary sinus (CS) anatomies allow a more straightforward CS Reducer (CSR) implantation. BACKGROUND: Recent decades have seen a rise in patients with chronic angina. When complete revascularization and maximal medical therapy fail to reduce symptoms, CSR has become a new therapeutic option. METHODS: We identified a classical C-shape-a near horizontal course of the proximal portion of a circular CS-in a retrospective analysis of 47 CSR implantations and compared the procedural time, fluoroscopic time, contrast use, presence of valves or bifurcations and procedural complications with the non-C-shape CS anatomy. RESULTS: We found a significant difference in procedural (20.0 [19.0-24.7] min vs. 24.5 [20.7-51.0] min; p = .028 and fluoroscopic time (9.5 [7.5-14.5] min vs. 11.0 [7.9-30.0] min; p = .016). There was no significant difference in contrast use. The presence of bifurcations or valves along the CS course did not influence the procedural timings. CONCLUSION: This study is the first systematic evaluation of CS anatomy and its procedural implications. We identified a favorable C-shape anatomy which allows for a more straightforward implantation. Operators should be aware of the different implications of CS anatomy, their influence on guiding catheter stability and overall procedure complexity.


Assuntos
Seio Coronário , Angina Pectoris , Seio Coronário/diagnóstico por imagem , Humanos , Estudos Retrospectivos , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 98(6): E870-E880, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-33909348

RESUMO

OBJECTIVES: To determine the prognostic impact of anemia in patients randomized to bivalirudin or unfractionated heparin (UFH) during transcatheter aortic valve replacement (TAVR). BACKGROUND: Whether the periprocedural use of bivalirudin as compared with UFH in anemic patients undergoing TAVR has an impact on outcomes remains unknown. METHODS: The BRAVO-3 trial compared the use of bivalirudin versus UFH in 802 high risk patients undergoing transfemoral TAVR for severe symptomatic aortic stenosis. Patients were stratified according to the presence (defined as hemoglobin levels <13 g/dl in men and <12 g/dl in women) or absence of anemia. The primary outcomes were net adverse cardiac events (NACE; a composite of all-cause mortality, myocardial infarction, stroke, or bleeding) and major bleeding (Bleeding Academic Research Consortium ≥3b) at 30 days. RESULTS: Among 798 patients with available baseline hemoglobin levels, 427 (54%) were anemic of whom 221 (52%) received bivalirudin. There were no significant differences in NACE and major bleeding at 30 days between patients with and without anemia, irrespective of the type of anticoagulant used (pinteraction  = 0.71 for NACE, pinteraction  = 1.0 for major bleeding). However, anemic patients had a higher risk of major vascular complications (adjusted OR 2.43, 95% CI 1.42-4.16, p = 0.001), and acute kidney injury (adjusted OR 1.74, 95% CI 1.16-2.59, p = 0.007) compared to non-anemic patients at 30 days. CONCLUSIONS: Anemia was not associated with a higher risk of NACE or major bleeding at 30 days after TAVR without modification of the treatment effects of periprocedural anticoagulation with bivalirudin versus UFH.


Assuntos
Anemia , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Anemia/diagnóstico , Antitrombinas , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Heparina , Humanos , Masculino , Nitrilas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 97(7): 1462-1469, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33443813

RESUMO

OBJECTIVES: We aimed to evaluate the effect of transcatheter aortic valve implantation (TAVI) approaches on mortality and identify effect modifiers and predictors for mortality. BACKGROUND: Alternative access routes to transfemoral (TF) TAVI include the surgical intra-thoracic direct-aortic (DA) and transapical (TA) approach. TA TAVI has been associated with a higher mortality rate. We hypothesized that this is related to effect modifiers, in particular the left ventricular ejection fraction (LVEF). METHODS: This multicentre study derived its data from prospective registries. To adjust for confounders, we used propensity-score based, stabilized inverse probability weighted Cox regression models. RESULTS: In total, 5,910 patients underwent TAVI via TF (N = 4,072), DA (N = 524), and TA (N = 1,314) access. Compared to TF, 30-day mortality was increased among DA (HR 1.87, 95%CI 1.26-2.78, p = .002) and TA (HR 3.34, 95%CI 2.28-4.89, p < .001) cases. Compared to TF, 5-year mortality was increased among TA cases (HR 1.50, 95%CI 1.24-1.83, p < .001). None of the variables showed a significant interaction between the approaches and mortality. An impaired LVEF (≤35%) increased mortality in all approaches. CONCLUSIONS: The surgical intra-thoracic TA and DA TAVI are both associated with a higher 30-day mortality than TF TAVI. TA TAVI is associated with a higher 5-year mortality than TF TAVI. The DA approach may therefore have some advantages over the TA approach when TF access is not feasible.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Prospectivos , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda
15.
Circulation ; 139(1): 67-77, 2019 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-30586704

RESUMO

BACKGROUND: Polymer-free amphilimus-eluting stents (PF-AES) represent a novel elution technology in the current era of drug-eluting stents. The clinical safety and efficacy of PF-AES as compared with latest-generation permanent-polymer zotarolimus-eluting stents (PP-ZES) have not yet been investigated in a large randomized trial. METHODS: In this physician-initiated, prospective, multicenter, randomized, noninferiority trial, an all-comers population requiring percutaneous coronary intervention was enrolled across 3 European sites. Randomization (1:1 ratio) to PP-ZES or PF-AES was performed after stratification for troponin status and diabetes mellitus. In both treatment arms, troponin-positive patients were planned for 12-month dual antiplatelet therapy, whereas troponin-negative patients were planned for 1-month dual antiplatelet therapy. Outcome assessors were blinded to the allocated treatment. The device-oriented primary end point of target-lesion failure was defined as cardiac death, target-vessel myocardial infarction, or target-lesion revascularization at 12-months as analyzed by modified intention-to-treat (80% power, and a 3.5% noninferiority margin). RESULTS: In total, 1502 patients were randomized and 1491 treated with the assigned stent and available for follow-up. The primary end point occurred in 42 (5.6%) of the 744 patients receiving PP-ZES versus 46 (6.2%) of the 747 patients receiving PF-AES. PF-AES were clinically noninferior to PP-ZES (risk difference, 0.5%; upper limit 1-sided 95% confidence interval, 2.6%; Pnoninferiority=0.0086). Cardiac death occurred in 10 (1.3%) versus 10 patients (1.3%; P value for difference, 1.00), target-vessel myocardial infarction occurred in 18 (2.4%) versus 17 patients (2.3%; P value for difference, 0.87), and target-lesion revascularization occurred in 22 (2.9%) versus 20 patients (2.6%; P value for difference, 0.75) for PF-AES as compared with PP-ZES. Overall, definite or probable stent thrombosis occurred in 1.0%. CONCLUSIONS: PF-AES were noninferior to PP-ZES regarding target-lesion failure at 12 months. Findings regarding the secondary end point and prespecified subgroups were generally consistent with that of the primary end point. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02328898.


Assuntos
Síndrome Coronariana Aguda/terapia , Angina Estável/terapia , Angina Instável/terapia , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/análogos & derivados , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/mortalidade , Idoso , Angina Estável/diagnóstico , Angina Estável/mortalidade , Angina Instável/diagnóstico , Angina Instável/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
16.
BMC Cardiovasc Disord ; 20(1): 285, 2020 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-32527220

RESUMO

BACKGROUND: Previous renal denervation (RDN) studies showed controversial results in reducing blood pressure. The aim of this study was to provide evidence supporting the effectiveness of laparoscopic-based renal denervation (L-RDN) in treating hypertension. METHODS: Sixteen Beagle dogs were randomly divided into RDN group (n = 12) and sham group (n = 4). Neurogenic hypertension was generated in all dogs via carotid artery route. L-RDN was performed in the RDN group, with sham operation performed as a control. Blood pressure (BP) changes were recorded at 2, 4, 6, and 8 weeks after the procedure. Changes in serum creatinine (sCr), blood urea nitrogen (BUN) and level of norepinephrine (NE) were analyzed. Histological changes of kidney and renal arteries were also evaluated. RESULTS: BP and NE levels were significantly elevated after hypertension induction (p < 0.01). Systolic and diastolic BP of RDN group were decreased by 15.5 mmHg and 7.3 mmHg (p < 0.0001 and p = 0.0021, respectively) at the eighth week after L-RDN. Invasive systolic and diastolic BP of RDN group were significantly decreased by 14.5 mmHg and 15.3 mmHg (p < 0.0001). In contrast, there was no significant decrease in blood pressure in the sham group. In addition, RDN group but not the sham group showed a significant decrease in NE levels (p < 0.001), while no significant changes in sCr and BUN were observed in both groups. Pathological examinations showed no discernible damage, tear, or dissection to the renal arteries in RND group. CONCLUSIONS: L-RDN lowered BP and NE levels in hypertensive dogs without affecting renal artery morphology and kidney function.


Assuntos
Pressão Sanguínea , Hipertensão/cirurgia , Rim/irrigação sanguínea , Laparoscopia , Artéria Renal/inervação , Simpatectomia , Nervo Vago/cirurgia , Animais , Biomarcadores/sangue , Nitrogênio da Ureia Sanguínea , Creatinina/sangue , Modelos Animais de Doenças , Cães , Feminino , Hipertensão/etiologia , Hipertensão/fisiopatologia , Masculino , Norepinefrina/sangue , Fatores de Tempo , Nervo Vago/fisiopatologia
17.
Int Heart J ; 61(4): 713-719, 2020 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-32684591

RESUMO

Differences in the benefits of conscious sedation (CS) and general anesthesia (GA) during transfemoral aortic valve implantation (TAVI) are unclear.We aimed to assess differences in procedural and clinical outcomes based on the type of anesthesia received during TAVI.We analyzed SOURCE 3 Registry data for patients who received the SAPIEN 3 valve by type of anesthesia used during TAVI.Of the 1694 TAVI patients, 1027 received CS and 667 received GA. Patients were similar at baseline (81.5 years; Society of Thoracic Surgeons risk score 7.0). Compared with the GA group, the CS group had fewer intra-procedural transesophageal echocardiography (TEE) and post implantation dilatations performed, and less contrast medium was used. The CS group had significantly less kidney injury at 7 days post-procedure than the GA group (0.4% versus 1.5%, P = 0.014). Moderate paravalvular leaks (PVL) occurred more frequently in the CS group versus the GA group (2.2% versus 0.8%; P = 0.041). No severe PVL were reported. Median total hospital length of stay (LOS) after TAVI was 10 days in the CS group and 11 days in the GS group. At 30 days, all-cause death was 2.1% in CS and 1.7% in GS (P = 0.47), and myocardial infarction was 0.2% in CS and 0.1% in GS (P = 0.83).Our analyses found no significant major outcome differences between CS and GA during TAVI.


Assuntos
Anestesia Geral/estatística & dados numéricos , Sedação Consciente/estatística & dados numéricos , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino
18.
Catheter Cardiovasc Interv ; 94(1): 61-69, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30604493

RESUMO

BACKGROUND: Polymer-free amphilimus-eluting stents (PF-AES) represent a novel elution-technology in coronary stenting. We aimed to assess 1-year clinical outcomes of PF-AES as compared to latest-generation permanent polymer zotarolimus-eluting stents (PP-ZES) in a real-world all-comers setting. METHODS: A prospective registry of patients treated with either PF-AES or PP-ZES between 2014 and 2016 was conducted. The primary outcome was defined as major adverse cardiac and cerebrovascular events (MACCE), and the secondary outcome was defined as target-lesion failure (TLF) at 1 year. To account for measured confounders, a propensity-score adjusted Cox proportional-hazard model was built to evaluate clinical outcomes. RESULTS: A total of 734 consecutive patients with 1,269 DES implantations were enrolled. The population was characterized by 28% diabetes, 24% ST-segment elevation myocardial infarction, and a high number of complex lesions (69%). The rate of MACCE was 11.5% for PF-AES and 13.6% for PP-ZES, plog-rank = 0.11. TLF was numerically lower in PF-AES as compared to PP-ZES (5.4 vs. 6.1%, plog-rank = 0.68). After propensity-score adjustment, PF-AES showed a trend toward a lower rate of MACCE and a favorable rate of TLF as compared to PP-ZES (HR 0.70; 95%CI 0.45 to 1.10, P = 0.12; and HR 0.88; 95%CI 0.47 to 1.65, P = 0.68, respectively). Rates of definite ST were low (0.8 vs. 0.3%, plog-rank = 0.62). CONCLUSIONS: Our study suggests that implantation of PF-AES was safe and effective in real-world patients, with low-rates of MACCE and TLF at 1 year. Our data needs to be confirmed by a large trial to evaluate the clinical outcomes of this novel polymer-free, eluting-technology used in PF-AES.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Pontuação de Propensão , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 94(6): 795-805, 2019 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30901147

RESUMO

OBJECTIVES: To explore the prevalence of smoking, and its association with clinical and mortality outcome among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Less data exist regarding the effect of baseline smoking status on clinical and mortality outcome among patients undergoing TAVR. METHODS: Consecutive patients who underwent TAVR at two high volume Dutch centers were included. Smoking status was prospectively questioned by a structured interview at admission. Primary endpoint was 1-year all-cause mortality after TAVR. RESULTS: A total of 913 consecutive patients (80.1 ± 7.6 years; logistic EuroSCORE: 16.5 ± 9.9%) who underwent TAVR for severe aortic valve stenosis were included. There were 47% (n = 432) males, and 57% (n = 522) never-smokers, and 35% (n = 317) prior-smokers, and 8% (n = 74) current-smokers. Smokers (i.e., prior-smokers or current-smokers) were younger compared to never-smokers (78.9 ± 7.9 and 76.4 ± 8.0 vs. 81.3 ± 7.1, P < 0.000, respectively). Median follow-up time was 365 (interquartile range [IQR]: 280-365) days. Overall, prior-smoking was not associated with all-cause mortality at 1-year following TAVR (hazard ratio [HR] 0.83, 95% confidence interval [CI] 0.55-1.23). After stratification according to sex, male prior-smokers showed better 1-year survival after TAVR than male never-smokers (12% vs. 20%; P = 0.018, respectively, HR 0.52, 95% CI 0.29-0.89), while this reversed effect was not observed among female prior-smokers versus female never-smokers after TAVR (HR 1.70, 95% CI 0.95-3.05). CONCLUSIONS: Overall, baseline prior-smokers had similar 1-year mortality outcome after TAVR compared with baseline never-smokers. However, there was a reversed association between baseline prior-smoking status and 1-year mortality after TAVR among males, which could partially be explained due to the favorable baseline characteristics.


Assuntos
Estenose da Valva Aórtica/cirurgia , Fumar Cigarros/efeitos adversos , Ex-Fumantes , não Fumantes , Fumantes , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Fumar Cigarros/mortalidade , Feminino , Humanos , Masculino , Países Baixos , Prevalência , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
20.
Catheter Cardiovasc Interv ; 91(5): 884-891, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28707375

RESUMO

BACKGROUND: Patients with diabetes mellitus (DM) remain at higher risk of restenosis after percutaneous coronary intervention despite the use of contemporary drug-eluting stents. The Cre8 amphilimus-eluting stent (AES) has shown promising results in DM patients. Whether this holds true irrespective of patient's clinical and angiographic complexity is unknown. METHODS: Five hundred and ninety five consecutive patients (738 lesions) undergoing AES implantation were included in the INVESTIG8 multicenter registry. Patients were stratified according to DM status and further stratified according to patients' complexity. The prespecified primary endpoint was target lesion failure (TLF)-defined as the composite of cardiac death, target-vessel myocardial infarction, and target lesion revascularization (TLR). RESULTS: DM patients were more often complex as compared to non-DM patients (70% vs. 61%, P = 0.015). At 18-month follow-up, there was a trend to a higher TLF rate in DM than in non-DM patients (6.9% vs. 3.5%, P = 0.063). This was largely driven by a markedly higher risk of TLF among complex DM patients as compared to simple DM patients (8.9% vs. 2.4%, P = 0.053). A multivariate analysis identified complexity (HR 6.11, 95% CI: 1.42-26.2) but not DM (HR 1.59; 95% CI 0.71-3.56) as an independent predictor of TLF. Of note, TLR rates were similar between DM and non-DM patients (3.3% vs. 1.9%, P = 0.228). CONCLUSIONS: In this real-world, multicenter registry the Cre8 AES showed favorable clinical outcomes in DM patients. Increased risk of TLF appears to be driven by patients' complexity rather than DM status. These findings will need to be confirmed in a large-scale randomized trial.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/etiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Stents Farmacológicos/efeitos adversos , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Recidiva , Sistema de Registros , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS