1.
Phys Med Biol ; 50(18): 4371-84, 2005 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-16148399

RESUMO

Despite its advantages, the polymer gel-magnetic resonance imaging (MRI) method has not, as yet, been successfully employed in dosimetry of low energy/low dose rate photon-emitting brachytherapy sources such as 125I or 103Pd interstitial seeds. In the present work, two commercially available 125I seed sources, each of approximately 0.5 U, were positioned at two different locations of a polymer gel filled vial. The gel vial was MR scanned with the sources in place 19 and 36 days after seed implantation. Calibration curves were acquired from the coupling of MRI measurements with accurate Monte Carlo dose calculations obtained simulating the exact experimental setup geometry and materials. The obtained gel response data imply that while linearity of response is sustained, sensitivity (calibration curve slope) is significantly increased (approximately 60%) compared to its typical value for the 192Ir (or 60Co and 6 MV LINAC) photon energies. Water equivalence and relative energy response corrections of the gel cannot account for more than 3-4% of this increase, which, therefore, has to be mainly attributed to physicochemical processes related to the low dose rate of the sources and the associated prolonged irradiation time. The calibration data obtained from one 125I source were used to provide absolute dosimetry results for the other 125I source, which were found to agree with corresponding Monte Carlo calculations within experimental uncertainties. It is therefore suggested that, regardless of the underlying factors accounting for the gel dose response to 125I irradiations, polymer gel dosimetry of new 125I or 103Pd sources should be carried out as originally proposed by Heard and Ibbot (2004 J. Phys.: Conf. Ser. 3 221-3), i.e., by irradiating the same gel sample with the new low dose rate source, as well as with a well-characterized low dose rate source which will provide the dose calibration curve for the same irradiation conditions.


Assuntos
Braquiterapia/instrumentação , Braquiterapia/métodos , Radioisótopos do Iodo/uso terapêutico , Radiometria/métodos , Calibragem , Géis , Imageamento por Ressonância Magnética , Método de Monte Carlo , Fótons , Polímeros/química , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos
2.
Phys Rev Lett ; 97(21): 212001, 2006 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-17155738

RESUMO

The mean square polarizability radii of the proton have been measured for the first time in a virtual-Compton-scattering experiment performed at the MIT-Bates out-of-plane scattering facility. Response functions and polarizabilities obtained from a dispersion analysis of the data at Q2 = 0.057 GeV2/c2 are in agreement with O(p3) heavy baryon chiral perturbation theory. The data support the dominance of mesonic effects in the polarizabilities.

3.
Phys Rev Lett ; 94(2): 022003, 2005 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-15698166

RESUMO

We report new precise H(e,e(')p)pi(0) measurements at the Delta(1232) resonance at Q(2)=0.127 (GeV/c)(2) obtained at the MIT-Bates out-of-plane scattering facility which are particularly sensitive to the transverse electric amplitude (E2) of the gamma(*)N-->Delta transition. The new data have been analyzed together with those of earlier measurements to yield precise quadrupole to dipole amplitude ratios: Re(E(3/2)(1+)/M(3/2)(1+))=(-2.3+/-0.3(stat+syst)+/-0.6(model))% and Re(S(3/2)(1+)/M(3/2)(1+))=(-6.1+/-0.2(stat+syst)+/-0.5(model))% for M(3/2)(1+)=(41.4+/-0.3(stat+syst)+/-0.4(model))(10(-3)/m(pi(+))). The derived amplitudes give credence to the conjecture of deformation in hadrons favoring, at low Q2, the dominance of mesonic effects.