Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Pulm Med ; 24(1): 385, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39123152

RESUMO

BACKGROUND: The aim of our study was to investigate serum chitotriosidase level in tuberculosis patients, its relationship with microbiological and clinical parameters, and response to treatment. MATERIALS AND METHODS: This longitudinal panel study included 149 patients with confirmed TB disease. Serum chitotriosidase activity was measured at the beginning and the end of treatment. Factors associated with chitotriosidase activity were explored using univariate and multivariable logistic regression analysis. RESULTS: Out of 149 study participants, 71(47.7%) were female. The mean age was 53.0 (SD = 18.2). Majority of cases were new 118(79.2), predominantly 145 (97.3%) having pulmonary tuberculosis. More than half of the patients were sputum smear positive 91 (61.1%) while culture positive in 146 (98%) of them. According to radiological findings, cavitary lesions were found in 92 (63.4%) patients. Anti TB treatment was associated with significant decrease in serum chitotriosidase level (< 0.001). New TB treatment (OR = 4.41%;95% CI = 1.20-9.89), and cavitary lesions (OR = 3.86;95%CI = 0,59-26.57) were found to be significantly associated with decrease of chitotriosidase activity. CONCLUSIONS: The results of our study showed that serum chitotriosidase values are strong biomarkers for starting anti TB treatment and for treatment monitoring, since decrease in serum chitotriosidase level can predict favorable treatment response in patients with tuberculosis. Further studies are needed to explore these, and other factors associated with chitotriosidase activity among tuberculosis patients.


Assuntos
Antituberculosos , Hexosaminidases , Escarro , Tuberculose Pulmonar , Humanos , Feminino , Hexosaminidases/sangue , Masculino , Pessoa de Meia-Idade , Antituberculosos/uso terapêutico , Tuberculose Pulmonar/tratamento farmacológico , Tuberculose Pulmonar/sangue , Adulto , Idoso , Escarro/microbiologia , Estudos Longitudinais , Sérvia , Modelos Logísticos , Resultado do Tratamento , Biomarcadores/sangue , Análise Multivariada , Mycobacterium tuberculosis/isolamento & purificação
2.
Clin Chem Lab Med ; 56(12): 2015-2038, 2018 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-30004902

RESUMO

This document provides a joint recommendation for venous blood sampling of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Preanalytical Phase (WG-PRE) and Latin American Working Group for Preanalytical Phase (WG-PRE-LATAM) of the Latin America Confederation of Clinical Biochemistry (COLABIOCLI). It offers guidance on the requirements for ensuring that blood collection is a safe and patient-centered procedure and provides practical guidance on how to successfully overcome potential barriers and obstacles to its widespread implementation. The target audience for this recommendation are healthcare staff members directly involved in blood collection. This recommendation applies to the use of a closed blood collection system and does not provide guidance for the blood collection with an open needle and syringe and catheter collections. Moreover, this document neither addresses patient consent, test ordering, sample handling and transport nor collection from children and unconscious patients. The recommended procedure is based on the best available evidence. Each step was graded using a system that scores the quality of the evidence and the strength of the recommendation. The process of grading was done at several face-to-face meetings involving the same mixture of stakeholders stated previously. The main parts of this recommendation are: 1) Pre-sampling procedures, 2) Sampling procedure, 3) Post-sampling procedures and 4) Implementation. A first draft of the recommendation was circulated to EFLM members for public consultation. WG-PRE-LATAM was also invited to comment the document. A revised version has been sent for voting on to all EFLM and COLABIOCLI members and has been officially endorsed by 33/40 EFLM and 21/21 COLABIOCLI members. We encourage professionals throughout Europe and Latin America to adopt and implement this recommendation to improve the quality of blood collection practices and increase patient and workers safety.


Assuntos
Coleta de Amostras Sanguíneas , Ciência de Laboratório Médico , Química Clínica , Europa (Continente) , Humanos , América Latina
3.
Clin Chem Lab Med ; 57(2): 183-194, 2018 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-30055099

RESUMO

Background Nowadays over-the-counter (OTC) drugs and dietary supplements are widely used. Their use can have a significant impact on the validity of laboratory results. The aim of this multicenter European study was to determine the frequency of consumption of various dietary products and OTC drugs among patients and explore their level of knowledge and awareness about the potential impact of various products on laboratory test results. Methods Eighteen European countries participated in this study. The survey was carried out anonymously on a subsequent series of outpatients (n=200) in each participating country. Included were patients who were referred to the laboratory for blood sampling and who voluntarily agreed to participate in the study. The survey included questions about the frequency of consumption of various products, awareness of the importance of informing physicians and laboratory staff about it and information about influence of preanalytical factors in general on laboratory test results. Results In total, 68% of patients were regularly taking at least one OTC drug or dietary supplement. The frequency of patients consuming at least one OTC drug or dietary supplement differed between countries (p=0.001). Vitamins (38%), minerals (34%), cranberry juice (20%), acetylsalicylic acid (ASA) (17%) and omega fatty acids (17%) were the most commonly used in our study. Conclusions The use of various OTC drugs and dietary supplements is highly prevalent in Europe and patients are often not willing to disclose this information to the laboratory staff and ordering physician. The education of both patients and healthcare staff is needed.


Assuntos
Conscientização , Testes de Química Clínica , Suplementos Nutricionais , Conhecimento , Medicamentos sem Prescrição , Pacientes/psicologia , Europa (Continente) , Humanos , Inquéritos e Questionários
4.
Clin Chem Lab Med ; 55(10): 1478-1488, 2017 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-28688224

RESUMO

The improving quality of laboratory testing requires a deep understanding of the many vulnerable steps involved in the total examination process (TEP), along with the identification of a hierarchy of risks and challenges that need to be addressed. From this perspective, the Working Group "Laboratory Errors and Patient Safety" (WG-LEPS) of International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) is focusing its activity on implementation of an efficient tool for obtaining meaningful information on the risk of errors developing throughout the TEP, and for establishing reliable information about error frequencies and their distribution. More recently, the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has created the Task and Finish Group "Performance specifications for the extra-analytical phases" (TFG-PSEP) for defining performance specifications for extra-analytical phases. Both the IFCC and EFLM groups are working to provide laboratories with a system to evaluate their performances and recognize the critical aspects where improvement actions are needed. A Consensus Conference was organized in Padova, Italy, in 2016 in order to bring together all the experts and interested parties to achieve a consensus for effective harmonization of quality indicators (QIs). A general agreement was achieved and the main outcomes have been the release of a new version of model of quality indicators (MQI), the approval of a criterion for establishing performance specifications and the definition of the type of information that should be provided within the report to the clinical laboratories participating to the QIs project.


Assuntos
Laboratórios/normas , Segurança do Paciente/normas , Congressos como Assunto , Erros de Diagnóstico , Humanos , Indicadores de Qualidade em Assistência à Saúde/normas
5.
Clin Chem Lab Med ; 55(3): 348-357, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27988505

RESUMO

The knowledge of error rates is essential in all clinical laboratories as it enables them to accurately identify their risk level, and compare it with those of other laboratories in order to evaluate their performance in relation to the State-of-the-Art (i.e. benchmarking) and define priorities for improvement actions. Although no activity is risk free, it is widely accepted that the risk of error is minimized by the use of Quality Indicators (QIs) managed as a part of laboratory improvement strategy and proven to be suitable monitoring and improvement tools. The purpose of QIs is to keep the error risk at a level that minimizes the likelihood of patients. However, identifying a suitable State-of-the-Art is challenging, because it calls for the knowledge of error rates measured in a variety of laboratories throughout world that differ in their organization and management, context, and the population they serve. Moreover, it also depends on the choice of the events to keep under control and the individual procedure for measurement. Although many laboratory professionals believe that the systemic use of QIs in Laboratory Medicine may be effective in decreasing errors occurring throughout the total testing process (TTP), to improve patient safety as well as to satisfy the requirements of International Standard ISO 15189, they find it difficult to maintain standardized and systematic data collection, and to promote continued high level of interest, commitment and dedication in the entire staff. Although many laboratories worldwide express a willingness to participate to the Model of QIs (MQI) project of IFCC Working Group "Laboratory Errors and Patient Safety", few systematically enter/record their own results and/or use a number of QIs designed to cover all phases of the TTP. Many laboratories justify their inadequate participation in data collection of QIs by claiming that the number of QIs included in the MQI is excessive. However, an analysis of results suggests that QIs need to be split into further measurements. As the International Standard on Laboratory Accreditation and approved guidelines do not specify the appropriate number of QIs to be used in the laboratory, and the MQI project does not compel laboratories to use all the QIs proposed, it appears appropriate to include in the MQI all the indicators of apparent utility in monitoring critical activities. The individual laboratory should also be able to decide how many and which QIs can be adopted. In conclusion, the MQI project is proving to be an important tool that, besides providing the TTP error rate and spreading the importance of the use of QIs in enhancing patient safety, highlights critical aspects compromising the widespread and appropriate use of QIs.


Assuntos
Serviços de Laboratório Clínico/normas , Técnicas de Laboratório Clínico/normas , Laboratórios/normas , Erros Médicos/prevenção & controle , Segurança do Paciente , Indicadores de Qualidade em Assistência à Saúde , Humanos
6.
Clin Chem Lab Med ; 53(9): 1321-31, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25536667

RESUMO

BACKGROUND: An observational study was conducted in 12 European countries by the European Federation of Clinical Chemistry and Laboratory Medicine Working Group for the Preanalytical Phase (EFLM WG-PRE) to assess the level of compliance with the CLSI H3-A6 guidelines. METHODS: A structured checklist including 29 items was created to assess the compliance of European phlebotomy procedures with the CLSI H3-A6 guideline. A risk occurrence chart of individual phlebotomy steps was created from the observed error frequency and severity of harm of each guideline key issue. The severity of errors occurring during phlebotomy was graded using the risk occurrence chart. RESULTS: Twelve European countries participated with a median of 33 (18-36) audits per country, and a total of 336 audits. The median error rate for the total phlebotomy procedure was 26.9 % (10.6-43.8), indicating a low overall compliance with the recommended CLSI guideline. Patient identification and test tube labelling were identified as the key guideline issues with the highest combination of probability and potential risk of harm. Administrative staff did not adhere to patient identification procedures during phlebotomy, whereas physicians did not adhere to test tube labelling policy. CONCLUSIONS: The level of compliance of phlebotomy procedures with the CLSI H3-A6 guidelines in 12 European countries was found to be unacceptably low. The most critical steps in need of immediate attention in the investigated countries are patient identification and tube labelling.


Assuntos
Coleta de Amostras Sanguíneas/normas , Fidelidade a Diretrizes/estatística & dados numéricos , Guias de Prática Clínica como Assunto , Sociedades Científicas/normas , Inquéritos e Questionários , Humanos , Flebotomia , Medição de Risco
7.
Clin Chem Lab Med ; 52(7): 951-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24622792

RESUMO

Quality indicators (QIs) are fundamental tools for enabling users to quantify the quality of all operational processes by comparing it against a defined criterion. QIs data should be collected over time to identify, correct, and continuously monitor defects and improve performance and patient safety by identifying and implementing effective interventions. According to the international standard for medical laboratories accreditation, the laboratory shall establish and periodically review QIs to monitor and evaluate performance throughout critical aspects of pre-, intra-, and post-analytical processes. However, while some interesting programs on indicators in the total testing process have been developed in some countries, there is no consensus for the production of joint recommendations focusing on the adoption of universal QIs and common terminology in the total testing process. A preliminary agreement has been achieved in a Consensus Conference organized in Padua in 2013, after revising the model of quality indicators (MQI) developed by the Working Group on "Laboratory Errors and Patient Safety" of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). The consensually accepted list of QIs, which takes into consideration both their importance and applicability, should be tested by all potentially interested clinical laboratories to identify further steps in the harmonization project.


Assuntos
Técnicas de Laboratório Clínico/normas , Medicina Clínica/normas , Indicadores de Qualidade em Assistência à Saúde/normas , Humanos
8.
Blood Cells Mol Dis ; 50(3): 222-5, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23265739

RESUMO

INTRODUCTION: We evaluated a novel approach for investigation of lymphocyte dysregulation in Gaucher patients by including determination of IgH and TCR gene rearrangements together with levels of immunoglobulins, natural autoantibodies as well as presence of monoclonal protein. MATERIALS AND METHODS: Measurement of serum immunoglobulins, monoclonal immunoglobulins, selected autoantibodies, as well as analysis of immunoglobulin heavy chain and T cell receptor gene rearrangements. RESULTS: Immunoglobulin disorder was detected in 29.6% patients, 40.7% demonstrated presence of B cell clonality and 44.4% demonstrated presence of autoantibodies. In five patients in our series, the presence of IgH gene rearrangement was the only detectable indicator of B cell dysfunction. TCR gene rearrangements were not found in any of the patients. CONCLUSION: Based on our results, we propose IgH gene rearrangements as a new biomarker for investigation of B cell dysfunction occurring as a complication of Gaucher disease.


Assuntos
Linfócitos B/imunologia , Linfócitos B/metabolismo , Doença de Gaucher/genética , Doença de Gaucher/imunologia , Hipergamaglobulinemia/genética , Hipergamaglobulinemia/imunologia , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Cadeias Pesadas de Imunoglobulinas/genética , Masculino , Pessoa de Meia-Idade , Receptores de Antígenos de Linfócitos T/genética , Receptores de Antígenos de Linfócitos T/imunologia , Adulto Jovem
9.
Clin Chem Lab Med ; 51(8): 1585-93, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23729577

RESUMO

BACKGROUND: European questionnaire survey was conducted by the European Federation of Clinical Chemistry and Laboratory Medicine Working Group for the Preanalytical Phase (EFLM WG-PA) to assess how phlebotomy is performed in EFLM countries, including differences in personnel, level of education and skills, and to investigate the presence and compliance of national phlebotomy guidelines on this matter. METHODS: A questionnaire was constructed containing questions elucidating different aspects of the organization behind the phlebotomy praxis on a national basis, including questions on the staff performing phlebotomy, the education of these staff members, and the existence of and adherence to national guidelines. All 39 EFLM member countries were invited to participate. RESULTS: In total 28/39 (72%) EFLM member countries responded. Seven out of the 28 (25%) have national phlebotomy guidelines and five have implemented other guidelines. The estimated compliance with phlebotomy guidance for the laboratories in the countries that have national guidelines available is poor, regardless to whether the phlebotomy was under the laboratory control or not. Most countries were interested in EFLM guidelines and to participate in a pilot EFLM preanalytical phase external quality assessment (EQA) scheme. In the responding EFLM member countries, the majority of phlebotomy is performed by nurses and laboratory technicians. Their basic education is generally 4-5 years of high school, followed by 2-5 years of colleague or university studies. Only a third (10/28; 36%) of the participating member countries has any specific training available as a continuous educational resource. A specific training for phlebotomy is not part of the education required to become qualified in 6/28 (21%) and 9/28 (32%) of countries for nurses and laboratory technicians, respectively. In countries and professions where training is required, most require more than 5 h of training. CONCLUSIONS: Based on the results of this survey we conclude the following: 1) There is a need to assess the quality of current practices, compliance to the CLSI H3-A6 guidelines and to identify some most critical steps which occur during phlebotomy, in different healthcare settings, across Europe; 2) Existing CLSI H3-A6 phlebotomy guidelines should be adapted and used locally in all European countries which do not have their own guidelines; 3) National EFLM societies need to be engaged in basic training program development and continuous education of healthcare phlebotomy staff (implementing the certification of competence).


Assuntos
Química Clínica/educação , Química Clínica/normas , Guias como Assunto , Ciência de Laboratório Médico/educação , Ciência de Laboratório Médico/normas , Flebotomia , Química Clínica/organização & administração , Coleta de Dados , Escolaridade , União Europeia , Humanos , Ciência de Laboratório Médico/organização & administração , Prática Profissional , Inquéritos e Questionários
10.
Platelets ; 23(2): 143-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-21767238

RESUMO

There is a paucity of data on the effects of enzyme replacement therapy (ERT) on the coagulation abnormalities and platelet function of patients with Gaucher's disease (GDPs) and much of this data are controversial. This study investigates the haemostatic parameters in treatment-naïve GDPs and the effects of ERT. 31 Serbian treatment-naïve type 1 GDPs (M/F 17/14; median age 49 years, splenectomized 9/31) were studied. The complete blood count, prothrombin time (PT), activated partial tromboplastin time (aPTT) and coagulation factors were measured using the standard methods. Platelet aggregation was assessed with a whole-blood aggregometer. Splenic volumes were assessed using computer tomography. Twenty-one patients were treated with ERT (Imiglucerase). The haemostatic parameters were assessed after 6, 12 and 24 months (ERT(6, 12, 24)). Initially bleeding episodes were registered in 10/31 GDPs. Median platelet count was 108 × 10(9)/L; 22/31 GDPs were thrombocytopenic. The PT and aPTT values were abnormal in 16/31 and 13/31 GDPs, respectively. Platelet aggregation abnormalities were recorded in 19/31GDPs. Median platelet aggregation was reduced in response to adenosine-diphosphate 5 µmol/L (ADP(5) 0.46) and collagen 5 µmol/L (Col(5) 0.47). Splenic volume inversely correlated with the platelet count and a reduced response to arachidonic acid (AA), Col(5) and ADP(5) (p < 0.05). The splenectomized GDPs had a significantly lower platelet aggregation to Col(10) (p < 0.05). Bleeding GDPs had a significantly lower platelet count, higher chitotriosidase levels and a greater splenic volume compared to non-bleeding patients (p < 0.01). ERT: The number of bleeding GDPs had significantly decreased by ERT(6) (1/10; p < 0.01). The platelet count had significantly increased by ERT(6) (ERT(6) 180 × 10(9)/L, p < 0.01). The PT increased significantly from ERT(0) to ERT(24) (PT(0) 65%, PT(24) 81%; p < 0.05). The von Willebrand factor had increased significantly by ERT(6) and ERT(24) (ERT(0) 56%, ERT(6) 70%, ERT(12) 70%, ERT(24) 86%; p < 0.01). The number of GDPs with abnormal platelet aggregation had decreased significantly by ERT(6) (10/19; p < 0.05). Platelet aggregation on ADP(10) and AA significantly increased by ERT(6) (ADP(10): ERT(0) 0.75, ERT(6) 0.8 p < 0.01; AA: ERT(0) 0.7, ERT(6) 0.8 p < 0.05). In conclusion, platelet dysfunction and coagulation abnormalities were found in a considerable number of our GDPs. The absence of severe bleeding episodes suggests that the haemostatic system is sufficiently balanced and therefore the exact mechanism of the etiology of these abnormalities need to be fully clarified. ERT resulted in the cessation of bleeding and marked increase in platelet count, PT, vWF and platelet aggregation.


Assuntos
Terapia de Reposição de Enzimas/métodos , Doença de Gaucher/sangue , Doença de Gaucher/tratamento farmacológico , Glucosilceramidase/uso terapêutico , Adolescente , Adulto , Idoso , Coagulação Sanguínea/efeitos dos fármacos , Criança , Pré-Escolar , Feminino , Hemorragia/sangue , Hemorragia/etiologia , Hemostasia/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Agregação Plaquetária/efeitos dos fármacos , Contagem de Plaquetas , Baço/fisiopatologia , Adulto Jovem
11.
J Med Biochem ; 40(3): 245-251, 2021 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-34177368

RESUMO

Background: To investigate the influence of lipid metabolism disorders on the risk of deep vein thrombosis. Methods: A total of 200 subjects participated in the study, 100 of whom experienced DVT with or without PTE, and 100 healthy subjects representing the control group. We classified patients and controls in terms of serum concentrations of chylomicrons, LDL, IDL, VLDL, and HDL particles, as those with or without hyperlipoproteinemia and in terms of serum Lp (a) lipoprotein levels, as those with hyperLp (a) lipoproteinemia (serum Lp (a) values >0.3 g/L) and those without hyperLp (a) lipoproteinemia (serum Lp (a) values <0.3 g/L). Based on the modified and supplemented Fredrickson classification, participants with verified existences of hyperlipoproteinemia were classified into subgroups based on the type of hyperlipoproteinemia. Unconditional logistic regression was used to calculate ORs with 95% CIS as a measure of the relative risks for venous thrombosis in participants with hyperlipoproteinemia compared with those without hyperlipoproteinemia. The analysis was adjusted for all potential confounders (age, sex, obesity) related to the functionality of the lipid metabolism, and at the same time, may have an impact on the risk of venous thrombosis. Results: The results of the comparison of the mean values of individual lipid status parameters between the patient group and the control group clearly indicate higher concentrations of total cholesterol (5.93 mmol/L vs. 5.52 mmol/L), total triglycerides (1.58 mmol/L vs. 1.50 mmol/L), and LDL-cholesterol (3.83 mmol/L vs. 3.44 mmol/L) in the patient group relative to the control group, with a statistically significant difference observed only in the case of LDL-cholesterol concentrations. We have found that type IIa hyperlipoproteinemia is associated with a nearly double increased risk for deep vein thrombosis (OR 1.99; Cl 1.01-3.90), while type IIb, IV, or hyperLp (a) lipoproteinemia did not influence the risk (OR 1.22; 95% Cl 0.79-1.84; OR 0.89; 95% Cl 0.52-1.54 OR 1.85; 95% CI 0.84-4.04). Conclusions: Hypercholesterolemia doubles the risk of deep vein thrombosis development.

12.
Diagnosis (Berl) ; 8(1): 111-119, 2021 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-31990661

RESUMO

BACKGROUND: Laboratory tests are an essential aspect of current medical practice and their use has grown exponentially. Several studies however have demonstrated inappropriate use of laboratory testing. This inappropriateness can lead to delayed or wrong diagnosis, negatively impacting patient safety and an increase in health care expenditure. The aim of the present small-scale survey was to obtain information on the current status of demand management in European laboratories, as well as the opinions of laboratory and clinical professionals in this regard. METHODS: Two surveys were developed, one for laboratory specialists and one for clinicians, covering information on current use, knowledge and opinions on the possible impact of different demand management strategies on patient outcome and health care costs. Additionally, we asked for the current state and willingness on collaboration of laboratory specialists and clinicians. RESULTS: One hundred and fifty responses, 72 laboratory specialists and 78 clinicians, from nine countries were received. Developing local ordering protocols/profiles in collaboration with clinicians was the most used strategy (80.3% of laboratories). Of clinicians, 85.6% considered measures to ensure appropriate use of tests necessary and 100% were interested in advice/information about their indication. Of the laboratory specialists 97.2% were either already participating or willing to participate in multidisciplinary groups on the appropriateness of test demand as were 60.3% of clinicians, and 85.9% of clinicians were interested in attending activities about laboratory test demand management. CONCLUSIONS: The results of our survey show that tools to improve the appropriate use of laboratory tests are already regularly used today. Laboratory medicine specialists as well as clinicians are willing to undertake additional shared activities aimed at improving patient-centered laboratory diagnostic workup.


Assuntos
Laboratórios , Especialização , Europa (Continente) , Humanos , Inquéritos e Questionários
13.
J Med Biochem ; 39(1): 60-65, 2020 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-32549779

RESUMO

BACKGROUND: In a rare Gaucher disease, reduced activity of lysosomal b-glucocerebrosidase incompletely blocks glucosphingolipid catabolism. Accumulation of the unhydrolyzed substrate glucosylceramide within lysosomes results in progressive, multisystem Gaucher disease, classified into three types. Both parkinsonism and peripheral neuropathy are observed in cases of putative non-neuronopathic type 1 disease. In the current study we investigated whether the peripheral neural response in type 1 Gaucher disease patients, with no neural manifestations is conditioned by the influence of sex hormones. METHODS: The catalytic activity of b-glucocerebrosidase in peripheral blood leukocytes was determined spectrofluorometrically. Direct sequencing of the GBA1 gene was performed. Somatosensory evoked potentials were recorded after electrical stimulation of the median nerve of both arms. Stimuli of 0.2 ms duration at a frequency of 5 Hz were used. Sex hormones were determined by radioimmunoassay using a gamma scintillation counter. RESULTS: Analysis of the somatosensory evoked potentials revealed significant differences in peak latencies on periphery between men and women in both control and type 1 Gaucher disease groups. Analysis by gender showed significant associations between latencies and sex hormones only in female patients: negative correlation between oestradiol concentration and N9 peak latency, and a strong negative correlation of testosterone levels with all peak latencies on the periphery (N9-N13). CONCLUSIONS: A relationship between testosterone concentrations and the latencies of potentials evoked on peripheral nerves exists only in females with type 1 Gaucher disease. We point out sexual dimorphism in the development of this entity.

15.
Clin Chim Acta ; 497: 35-40, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31295446

RESUMO

Quality indicators (QIs) are key tools for improving the quality of laboratory services, by reducing error rates and safeguarding patient safety. A body of accumulated evidence confirms the relevance of QIs and their impact on the overall quality of laboratory information. The consensus achieved on a list of "harmonized" QIs, along with the system used for data collection and reporting throughout an international benchmarking programme, has enabled achieving realistic performance targets, based on knowledge of the state-of-the-art. Data collected in 2017 and 2018 have been analyzed and performance measures obtained by laboratories participating in the project are summarized in the present article. The laboratory performance measures have been classified into three levels (optimum, desirable or minimum) in agreement with the widely accepted model of analytical quality specifications.


Assuntos
Técnicas de Laboratório Clínico , Erros Médicos , Segurança do Paciente , Indicadores de Qualidade em Assistência à Saúde , Humanos
16.
J Med Biochem ; 38(3): 332-341, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31156344

RESUMO

BACKGROUND: The objective of this prospective study was to evaluate whether soluble programmed cell death-1/programmed cell death-ligand 1 (PD-1/PD-L1) and serum amyloid A1 (SAA1) are potential diagnostic, predictive or prognostic biomarkers in lung cancer. METHODS: Lung cancer patients (n=115) with advanced metastatic disease, 101 with non-small cell lung cancer, NSCLC (77 EGFR wild-type NSCLC patients on chemotherapy, 15 EGFR mutation positive adenocarcinoma patients, 9 patients with mPD-L1 Expression ≥50% NSCLC - responders to immunotherapy), and 14 patients with small cell lung cancer (SCLC) were examined. ELISA method was used to determine sPD-L1 and SAA1 concentrations in patients' plasma. RESULTS: Significantly higher blood concentrations of sPD-L1 and SAA1 were noted in lung cancer patients compared with a healthy control group. In PD-L1+ NSCLC patients, a significantly higher sPD-L1 level was noticed compared to any other lung cancer subgroup, as well as the highest average SAA1 value compared to other subgroups. CONCLUSIONS: It seems that sPD-1/PD-L1 might be a potential biomarker, prognostic and/ or predictive, particularly in patients treated with immunotherapy. Serum amyloid A1 has potential to act as a good predictor of patients' survival, as well as a biomarker of a more advanced disease, with possibly good capability to predict the course of disease measured at different time points.

17.
Ann Biol Clin (Paris) ; 77(2): 131-154, 2019 04 01.
Artigo em Francês | MEDLINE | ID: mdl-30998194

RESUMO

This document provides a joint recommendation for venous blood sampling of the European federation of clinical chemistry and laboratory medicine (EFLM) Working Group for preanalytical phase (WG-PRE) and Latin American working group for preanalytical phase (WG-PRE-LATAM) of the Latin America confederation of clinical biochemistry (COLABIOCLI). It offers guidance on the requirements for ensuring that blood collection is a safe and patient-centered procedure and provides practical guidance on how to successfully overcome potential barriers and obstacles to its widespread implementation. The target audience for this recommendation are healthcare staff members directly involved in blood collection. This recommendation applies to the use of a closed blood collection system and does not provide guidance for the blood collection with an open needle and syringe and catheter collections. Moreover, this document neither addresses patient consent, test ordering, sample handling and transport nor collection from children and unconscious patients. The recommended procedure is based on the best available evidence. Each step was graded using a system that scores the quality of the evidence and the strength of the recommendation. The process of grading was done at several face-to-face meetings involving the same mixture of stakeholders stated previously. The main parts of this recommendation are: 1) Pre-sampling procedures, 2) Sampling procedure, 3) Post-sampling procedures and 4) Implementation. A first draft of the recommendation was circulated to EFLM members for public consultation. WG-PRE-LATAM was also invited to comment the document. A revised version has been sent for voting on to all EFLM and COLABIOCLI members and has been officially endorsed by 33/40 EFLM and 21/21 COLABIOCLI members. We encourage professionals throughout Europe and Latin America to adopt and implement this recommendation to improve the quality of blood collection practices and increase patient and workers safety.


Assuntos
Coleta de Amostras Sanguíneas/normas , Química Clínica/normas , Técnicas de Laboratório Clínico/normas , Flebotomia/normas , Fase Pré-Analítica/normas , Adulto , Coleta de Amostras Sanguíneas/métodos , Química Clínica/organização & administração , Criança , Técnicas de Laboratório Clínico/métodos , Europa (Continente) , Humanos , América Latina , Flebotomia/métodos , Fase Pré-Analítica/métodos , Sociedades Médicas/organização & administração , Sociedades Médicas/normas , Manejo de Espécimes/métodos , Manejo de Espécimes/normas
18.
J Med Biochem ; 37(3): 279-288, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30584397

RESUMO

An adequate assessment of the measurement uncertainty in a laboratory medicine is one of the most important factors for a reliable interpretation of the results. A large number of standards and guidelines indicate the need for a proper assessment of the uncertainty of measurement results in routine laboratory practice. The available documents generally recommend participation in the proficiency schemes/ external quality control, as well as the internal quality control, in order to primarily verify the quality performance of the method. Although all documents meet the requirements of the International Standard, ISO 15189, the standard itself does not clearly define the method by which the measurement results need to be assessed and there is no harmonization in practice regarding to this. Also, the uncertainty of measurement results is the data relating to the measured result itself, but all factors that influence the interpretation of the measured value, which is ultimately used for diagnosis and monitoring of the patient's treatment, should be taken into account. So in laboratory medicine, an appropriate assessment of the uncertainty of the measurement results should have the ultimate goal of reducing diagnostic uncertainty. However, good professional laboratory practice and understanding analytical aspects of the test for each individual laboratory is necessary to adequately define the uncertainty of measurement results for specific laboratory tests, which helps to implement good clinical practice. Also, setting diagnoses in medicine is a decision with a certain degree of uncertainty, rather than statistically and mathematically calculated conclusion.

19.
J Med Biochem ; 37(3): 307-312, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30598627

RESUMO

BACKGROUND: Several studies support the evidence of increased incidence of hematological complications in Gaucher disease including monoclonal and polyclonal gammopathies and blood malignancies, especially multiple myeloma. METHODS: Serum concentrations of immunoglobulins and PCR analysis of the IGH gene rearrangements were performed. The clonal PCR products were directly sequenced and analyzed with the appropriate database and tools. Serum monoclonal proteins were detected and identified by electrophoresis. RESULTS: Among 27 Gaucher patients, clonal IGH rearrangement was discovered in eight, with 5/8 having also serum monoclonal protein. Elevated immunoglobulins were detected in 9/27 patients. Follow-up data for 17 patients showed that the clonal rearrangement remained the same in four of them, however, in one patient it disappeared after the follow-up period. The remaining 12/17 patients were without previous IGH clonal rearrangement and remained so after the follow-up. CONCLUSIONS: Although clonal expansion may occur relatively early in the disease course, at least judging by the IGH gene rearrangements in Gaucher patients, the detected clones may be transient. A careful clinical follow-up in these patients is mandatory, including monitoring for lymphoid neoplasms, especially multiple myeloma.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA