Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 202
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 390(3): 212-220, 2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38231622

RESUMO

BACKGROUND: The Resynchronization-Defibrillation for Ambulatory Heart Failure Trial (RAFT) showed a greater benefit with respect to mortality at 5 years among patients who received cardiac-resynchronization therapy (CRT) than among those who received implantable cardioverter-defibrillators (ICDs). However, the effect of CRT on long-term survival is not known. METHODS: We randomly assigned patients with New York Heart Association (NYHA) class II or III heart failure, a left ventricular ejection fraction of 30% or less, and an intrinsic QRS duration of 120 msec or more (or a paced QRS duration of 200 msec or more) to receive either an ICD alone or a CRT defibrillator (CRT-D). We assessed long-term outcomes among patients at the eight highest-enrolling participating sites. The primary outcome was death from any cause; the secondary outcome was a composite of death from any cause, heart transplantation, or implantation of a ventricular assist device. RESULTS: The trial enrolled 1798 patients, of whom 1050 were included in the long-term survival trial; the median duration of follow-up for the 1050 patients was 7.7 years (interquartile range, 3.9 to 12.8), and the median duration of follow-up for those who survived was 13.9 years (interquartile range, 12.8 to 15.7). Death occurred in 405 of 530 patients (76.4%) assigned to the ICD group and in 370 of 520 patients (71.2%) assigned to the CRT-D group. The time until death appeared to be longer for those assigned to receive a CRT-D than for those assigned to receive an ICD (acceleration factor, 0.80; 95% confidence interval, 0.69 to 0.92; P = 0.002). A secondary-outcome event occurred in 412 patients (77.7%) in the ICD group and in 392 (75.4%) in the CRT-D group. CONCLUSIONS: Among patients with a reduced ejection fraction, a widened QRS complex, and NYHA class II or III heart failure, the survival benefit associated with receipt of a CRT-D as compared with ICD appeared to be sustained during a median of nearly 14 years of follow-up. (RAFT ClinicalTrials.gov number, NCT00251251.).


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Estimativa de Kaplan-Meier , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Eletrocardiografia , Seguimentos , Fatores de Tempo
2.
Circulation ; 145(23): 1693-1704, 2022 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-35313733

RESUMO

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) frequently coexist and can be challenging to treat. Pharmacologically based rhythm control of AF has not proven to be superior to rate control. Ablation-based rhythm control was compared with rate control to evaluate if clinical outcomes in patients with HF and AF could be improved. METHODS: This was a multicenter, open-label trial with blinded outcome evaluation using a central adjudication committee. Patients with high-burden paroxysmal (>4 episodes in 6 months) or persistent (duration <3 years) AF, New York Heart Association class II to III HF, and elevated NT-proBNP (N-terminal pro brain natriuretic peptide) were randomly assigned to ablation-based rhythm control or rate control. The primary outcome was a composite of all-cause mortality and all HF events, with a minimum follow-up of 2 years. Secondary outcomes included left ventricular ejection fraction, 6-minute walk test, and NT-proBNP. Quality of life was measured using the Minnesota Living With Heart Failure Questionnaire and the AF Effect on Quality of Life. The primary analysis was time-to-event using Cox proportional hazards modeling. The trial was stopped early because of a determination of apparent futility by the Data Safety Monitoring Committee. RESULTS: From December 1, 2011, to January 20, 2018, 411 patients were randomly assigned to ablation-based rhythm control (n=214) or rate control (n=197). The primary outcome occurred in 50 (23.4%) patients in the ablation-based rhythm-control group and 64 (32.5%) patients in the rate-control group (hazard ratio, 0.71 [95% CI, 0.49-1.03]; P=0.066). Left ventricular ejection fraction increased in the ablation-based group (10.1±1.2% versus 3.8±1.2%, P=0.017), 6-minute walk distance improved (44.9±9.1 m versus 27.5±9.7 m, P=0.025), and NT-proBNP demonstrated a decrease (mean change -77.1% versus -39.2%, P<0.0001). Minnesota Living With Heart Failure Questionnaire demonstrated greater improvement in the ablation-based rhythm-control group (least-squares mean difference of -5.4 [95% CI, -10.5 to -0.3]; P=0.0036), as did the AF Effect on Quality of Life score (least-squares mean difference of 6.2 [95% CI, 1.7-10.7]; P=0.0005). Serious adverse events were observed in 50% of patients in both treatment groups. CONCLUSIONS: In patients with high-burden AF and HF, there was no statistical difference in all-cause mortality or HF events with ablation-based rhythm control versus rate control; however, there was a nonsignificant trend for improved outcomes with ablation-based rhythm control over rate control. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01420393.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Humanos , Qualidade de Vida , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
3.
N Engl J Med ; 382(19): 1823-1831, 2020 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-32374963

RESUMO

BACKGROUND: Access to pacemakers and defibrillators is problematic in places with limited resources. Resterilization and reuse of implantable cardiac devices obtained post mortem from patients in wealthier nations have been undertaken, but uncertainty around the risk of infection is a concern. METHODS: A multinational program was initiated in 1983 to provide tested and resterilized pacemakers and defibrillators to underserved nations; a prospective registry was established in 2003. Patients who received reused devices in this program were matched in a 1:3 ratio with control patients who received new devices implanted in Canada. The primary outcome was infection or device-related death, with mortality from other causes modeled as a competing risk. RESULTS: Resterilized devices were implanted in 1051 patients (mean [±SD] age, 63.2±18.5 years; 43.6% women) in Mexico (36.0%), the Dominican Republic (28.1%), Guatemala (26.6%), and Honduras (9.3%). Overall, 85% received pacemakers and 15% received defibrillators, with one (55.5%), two (38.8%), or three (5.7%) leads. Baseline characteristics did not differ between these patients and the 3153 matched control patients. At 2 years of follow-up, infections had occurred in 21 patients (2.0%) with reused devices and in 38 (1.2%) with new devices (hazard ratio, 1.66; 95% confidence interval, 0.97 to 2.83; P = 0.06); there were no device-related deaths. The most common implicated pathogens were Staphylococcus aureus and S. epidermidis. CONCLUSIONS: Among patients in underserved countries who received a resterilized and reused pacemaker or defibrillator, the incidence of infection or device-related death at 2 years was 2.0%, an incidence that did not differ significantly from that seen among matched control patients with new devices in Canada.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Reutilização de Equipamento , Infecções/etiologia , Marca-Passo Artificial/efeitos adversos , Adulto , Idoso , Estudos de Casos e Controles , Países em Desenvolvimento , Feminino , Seguimentos , Humanos , Incidência , Infecções/epidemiologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Mortalidade , Fatores de Risco , Esterilização
4.
Eur Heart J ; 43(32): 3071-3081, 2022 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-35352813

RESUMO

AIMS: Genetic testing is recommended in specific inherited heart diseases but its role remains unclear and it is not currently recommended in unexplained cardiac arrest (UCA). We sought to assess the yield and clinical utility of genetic testing in UCA using whole-exome sequencing (WES). METHODS AND RESULTS: Survivors of UCA requiring external defibrillation were included from the Cardiac Arrest Survivor with Preserved Ejection fraction Registry. Whole-exome sequencing was performed, followed by assessment of rare variants in previously reported cardiovascular disease genes. A total of 228 UCA survivors (mean age at arrest 39 ± 13 years) were included. The majority were males (66%) and of European ancestry (81%). Following advanced clinical testing at baseline, the likely aetiology of cardiac arrest was determined in 21/228 (9%) cases. Whole-exome sequencing identified a pathogenic or likely pathogenic (P/LP) variant in 23/228 (10%) of UCA survivors overall, increasing the proportion of 'explained' cases from 9% only following phenotyping to 18% when combining phenotyping with WES. Notably, 13 (57%) of the 23 P/LP variants identified were located in genes associated with cardiomyopathy, in the absence of a diagnosis of cardiomyopathy at the time of arrest. CONCLUSIONS: Genetic testing identifies a disease-causing variant in 10% of apparent UCA survivors. The majority of disease-causing variants was located in cardiomyopathy-associated genes, highlighting the arrhythmogenic potential of such variants in the absence of an overt cardiomyopathy diagnosis. The present study supports the use of genetic testing including assessment of arrhythmia and cardiomyopathy genes in survivors of UCA.


Assuntos
Cardiomiopatias , Parada Cardíaca , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/genética , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Cardiomiopatias/genética , Feminino , Testes Genéticos/métodos , Coração , Parada Cardíaca/etiologia , Humanos , Masculino
5.
Eur Heart J ; 43(32): e1-e9, 2022 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-35441664

RESUMO

AIMS: Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVC) is characterized by ventricular arrhythmias (VAs) and sudden cardiac death (SCD). We aimed to develop a model for individualized prediction of incident VA/SCD in ARVC patients. METHODS AND RESULTS: Five hundred and twenty-eight patients with a definite diagnosis and no history of sustained VAs/SCD at baseline, aged 38.2 ± 15.5 years, 44.7% male, were enrolled from five registries in North America and Europe. Over 4.83 (interquartile range 2.44-9.33) years of follow-up, 146 (27.7%) experienced sustained VA, defined as SCD, aborted SCD, sustained ventricular tachycardia, or appropriate implantable cardioverter-defibrillator (ICD) therapy. A prediction model estimating annual VA risk was developed using Cox regression with internal validation. Eight potential predictors were pre-specified: age, sex, cardiac syncope in the prior 6 months, non-sustained ventricular tachycardia, number of premature ventricular complexes in 24 h, number of leads with T-wave inversion, and right and left ventricular ejection fractions (LVEFs). All except LVEF were retained in the final model. The model accurately distinguished patients with and without events, with an optimism-corrected C-index of 0.77 [95% confidence interval (CI) 0.73-0.81] and minimal over-optimism [calibration slope of 0.93 (95% CI 0.92-0.95)]. By decision curve analysis, the clinical benefit of the model was superior to a current consensus-based ICD placement algorithm with a 20.3% reduction of ICD placements with the same proportion of protected patients (P < 0.001). CONCLUSION: Using the largest cohort of patients with ARVC and no prior VA, a prediction model using readily available clinical parameters was devised to estimate VA risk and guide decisions regarding primary prevention ICDs (www.arvcrisk.com).


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Taquicardia Ventricular , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Feminino , Humanos , Lactente , Masculino , Fatores de Risco , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia
6.
Am Heart J ; 234: 90-100, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33472052

RESUMO

Heart failure (HF) and atrial fibrillation (AF) are 2 cardiac conditions that are increasing in prevalence and incidence. The 2 conditions frequently coexist, and are associated with increased morbidity and mortality. Catheter ablation of AF has been successfully performed in patients with HF, with an improvement in HF and AF, when compared to amiodarone, but further data is required to compare this to rate control. OBJECTIVES: The primary objective is to determine whether AF treated by catheter ablation, with or without antiarrhythmic drugs reduces all-cause mortality and hospitalizations for HF as compared with rate control in patients with HF and a high burden AF. METHODS: This is a multi-center prospective randomized open blinded endpoint (PROBE) study. Patients with NYHA class II-III HF (HF with reduced ejection fraction (<35%) or HF with preserved ejection fraction), and high burden AF are included in the trial. Patients are randomized to either rate control or catheter ablation-based AF rhythm control in a 1:1 ratio. Patients in the rate control group receive optimal HF therapy and rate control measures to achieve a resting hazard ratio (HR) < 80 bpm and 6-minute walk HR < 110 bpm. Patients randomized to catheter ablation-based AF rhythm control group receive optimal HF therapy and one or more aggressive catheter ablation, which include PV antral ablation and LA substrate ablation with or without adjunctive antiarrhythmic drug. The primary outcome is a composite of all-cause mortality and hospitalization for heart failure defined as an admission to a health care facility. The sample size is 600. Enrolment has been completed.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Insuficiência Cardíaca/terapia , Anticoagulantes/administração & dosagem , Fibrilação Atrial/complicações , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Causas de Morte , Terapia Combinada/métodos , Tolerância ao Exercício , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Hospitalização , Humanos , Estudos Prospectivos , Qualidade de Vida , Tamanho da Amostra , Volume Sistólico
7.
Am J Med Genet A ; 182(10): 2359-2368, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32808748

RESUMO

Rare loss of function variants in DSP, which codes for the desmosomal protein desmoplakin, have been implicated in dilated and arrhythmogenic right ventricular cardiomyopathies. We present a family with arrhythmogenic cardiomyopathy associated with a novel missense variant in DSP (NM_004415.4): c.877G>A, p.(Glu293Lys). The phenotype is characterized by predominant involvement of the left ventricle with systolic dysfunction, fibrosis, and life-threatening arrhythmias. We performed a systematic review of literature collecting all cardiomyopathy cases with rare missense variants in DSP. We demonstrate that the distribution of missense variants across the protein domains in cardiomyopathy cases differs from that in gnomAD (p = .04), with a case enrichment of rare missense variants in the spectrin repeat domain (36/78 [46%] in cases vs. 449/1495 [30%] in gnomAD; p = .004). Our findings highlight the predominance of cardiac arrhythmia and left ventricular involvement in desmoplakin cardiomyopathy and pinpoint to a potential mutation hotspot in DSP thereby facilitating missense variant interpretation in the diagnostic setting.


Assuntos
Arritmias Cardíacas/genética , Displasia Arritmogênica Ventricular Direita/genética , Desmoplaquinas/genética , Predisposição Genética para Doença , Arritmias Cardíacas/patologia , Displasia Arritmogênica Ventricular Direita/patologia , Feminino , Variação Genética , Ventrículos do Coração/patologia , Humanos , Masculino , Mutação de Sentido Incorreto/genética , Fenótipo
8.
Eur Heart J ; 40(23): 1850-1858, 2019 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-30915475

RESUMO

AIMS: Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVC) is characterized by ventricular arrhythmias (VAs) and sudden cardiac death (SCD). We aimed to develop a model for individualized prediction of incident VA/SCD in ARVC patients. METHODS AND RESULTS: Five hundred and twenty-eight patients with a definite diagnosis and no history of sustained VAs/SCD at baseline, aged 38.2 ± 15.5 years, 44.7% male, were enrolled from five registries in North America and Europe. Over 4.83 (interquartile range 2.44-9.33) years of follow-up, 146 (27.7%) experienced sustained VA, defined as SCD, aborted SCD, sustained ventricular tachycardia, or appropriate implantable cardioverter-defibrillator (ICD) therapy. A prediction model estimating annual VA risk was developed using Cox regression with internal validation. Eight potential predictors were pre-specified: age, sex, cardiac syncope in the prior 6 months, non-sustained ventricular tachycardia, number of premature ventricular complexes in 24 h, number of leads with T-wave inversion, and right and left ventricular ejection fractions (LVEFs). All except LVEF were retained in the final model. The model accurately distinguished patients with and without events, with an optimism-corrected C-index of 0.77 [95% confidence interval (CI) 0.73-0.81] and minimal over-optimism [calibration slope of 0.93 (95% CI 0.92-0.95)]. By decision curve analysis, the clinical benefit of the model was superior to a current consensus-based ICD placement algorithm with a 20.6% reduction of ICD placements with the same proportion of protected patients (P < 0.001). CONCLUSION: Using the largest cohort of patients with ARVC and no prior VA, a prediction model using readily available clinical parameters was devised to estimate VA risk and guide decisions regarding primary prevention ICDs (www.arvcrisk.com).


Assuntos
Arritmias Cardíacas , Displasia Arritmogênica Ventricular Direita , Modelos Estatísticos , Adulto , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/epidemiologia , Displasia Arritmogênica Ventricular Direita/mortalidade , Morte Súbita Cardíaca/epidemiologia , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
9.
J Cardiovasc Electrophysiol ; 29(2): 308-315, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29064134

RESUMO

INTRODUCTION: Expert societies recently published strong recommendations to reduce the exposure of patients and staff to ionizing radiation (IR) during interventional and electrophysiology (EP) procedures. However, adherence to these guidelines remains difficult and the impact of implementing such recommendations is poorly characterized. METHODS AND RESULTS: We conducted a single-center cohort study to quantify radiation exposure over time in three EP laboratories at the Montreal Heart Institute during 5,546 consecutive procedures from 2012 to 2015 by 11 primary operators. Overall, 2,618 (47.2%) procedures were catheter-based and 2,928 (52.8%) were device interventions. Interventions to reduce radiation exposure included educational initiatives to raise awareness (i.e., limiting cine acquisition, patient position, table height), slower frame rate, lower radiation dose per pulse, collimation, and integration with 3-D mapping systems and/or MediGuide technology. An 85% reduction in IR exposure was observed from 2012 to 2015, with the mean dose-area-product (DAP) decreasing from 7.65 ± 0.05 Gy·cm2 to 1.15 ± 0.04 Gy·cm2 (P < 0.001). This was true for catheter-based procedures (mean DAP 16.99 ± 0.08 to 2.00 ± 0.06 Gy·cm2 , P < 0.001) and device interventions (mean DAP 4.18 ± 0.06 to 0.64 ± 0.05 Gy·cm2 , P < 0.001). The median effective dose of IR recorded per quarter by 282 cervical dosimeters on EP staff decreased from 0.57 (IQR 0.18, 1.03) mSv in 2012 to 0.00 (IQR 0.00, 0.19) mSv in 2015, P < 0.001. CONCLUSION: Enforcing good clinical practices with simple measures and low-dose fluoroscopy settings are highly effective in reducing IR exposure in the EP lab. These promising results should encourage other EP labs to adopt similar protective measures.


Assuntos
Cateterismo Cardíaco/métodos , Técnicas Eletrofisiológicas Cardíacas , Exposição Ocupacional/prevenção & controle , Implantação de Prótese/métodos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Humanos , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Fatores de Proteção , Exposição à Radiação/efeitos adversos , Proteção Radiológica , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
10.
J Cardiovasc Electrophysiol ; 28(5): 559-563, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28233925

RESUMO

INTRODUCTION: The standard 4-minute application time for transcatheter cryoablation was determined in the 1990s when the system employed less potent chlorofluorocarbon refrigerants. The current refrigerant, nitrous oxide, generates substantially colder temperatures, with a faster cooling rate. METHODS AND RESULTS: We conducted a preclinical study on 32 mongrel dogs with stratified randomization of right atrial, right ventricular, and left ventricular chambers to 2-minute versus 4-minute application times using 8-mm electrode tip cryocatheters (Freezor Max, Medtronic CryoCath LP, Montreal, Canada). Animals were sacrificed one month after the procedure. Three-dimensional morphometric analyses were conducted in a blinded fashion. A total of 193 identified ablation lesions were processed for histological analyses, 102 with 2-minute applications and 91 with 4-minute applications. Ablation lesion surface area (167.8 ± 21.6 mm2 vs. 194.3 ± 22.6 mm2 , P = 0.40), maximum depth (4.4 ± 0.2 mm vs. 4.5 ± 0.2 mm, P = 0.71), and volume (125.7 ± 69.5 mm3 vs. 141.0 ± 83.5 mm3 , P = 0.25) were similar between groups. Overall, 90.2% of ablation lesions in the right atrium were transmural, 45.6% in the right ventricle, and 2.4% in the left ventricle, with no differences between 2-minute and 4-minute application times (P = 0.55). Thrombus was detected on the endocardial surface of 0.0% and 3.3% of ablation lesions created with 2-minute and 4-minute application times, respectively (P = 0.10). CONCLUSION: Single 2-minute and 4-minute application times result in catheter ablation lesions of similar size using the modern cryoablation system with nitrous oxide as a refrigerant. While these findings suggest the potential to reduce the standard 4-minute application time, further studies are required to compare clinical efficacy.


Assuntos
Cateterismo Cardíaco/métodos , Temperatura Baixa , Criocirurgia/métodos , Átrios do Coração/cirurgia , Ventrículos do Coração/cirurgia , Óxido Nitroso/farmacologia , Animais , Cães , Átrios do Coração/patologia , Ventrículos do Coração/patologia , Modelos Animais , Fatores de Tempo
11.
Europace ; 19(6): 1043-1048, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27377075

RESUMO

AIMS: It remains unknown whether contact force (CF) sensing technology is of value for cavotricuspid isthmus (CTI) ablation. We prospectively evaluated procedural parameters and outcomes of CF-guided vs. CF-blinded CTI ablation for typical atrial flutter (AFL). METHODS AND RESULTS: A total of 70 consecutive patients (62.5 ± 10.9 years) undergoing CTI ablation for AFL were prospectively enrolled, 35 in CF-blinded and 35 in CF-guided groups. A CF-sensing catheter (power 25-35 W) was used in all. In the CF-guided group, CF target range was 10-25 g, whereas in the CF-blinded group, the operator was blinded to CF. The isthmus was divided into anterior, middle, and posterior segments for region-specific CF analysis. The procedural endpoint of bidirectional isthmus block following a 20-min observation period was achieved in all. A trend towards lower fluoroscopy and procedure duration was observed when the CF-guided group was compared with the CF-blinded group. The total radiofrequency (RF) energy delivery time required to achieve bidirectional block was significantly lower in the CF-guided vs. CF-blinded group [10.0 min (IQR 8.3;15.1) vs. 15.9 min (IQR 9.6;24.7), P= 0.0020], with a significant inverse correlation between CF and total RF delivery time (r = -0.36; P= 0.0027). Mean CF measurements significantly increased from anterior to posterior anatomical zones of CTI in the CF-blinded group (ANOVA P= 0.0466). CONCLUSIONS: Catheter ablation of AFL guided by real-time CF assessment results in a significant reduction in total RF delivery time. Real-time CF measurements facilitate the maintenance of homogenous efficient contact all along the CTI, particularly in the anterior segment where CF is generally lower.


Assuntos
Flutter Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Transdutores de Pressão , Potenciais de Ação , Idoso , Análise de Variância , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Distribuição de Qui-Quadrado , Desenho de Equipamento , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
Lancet ; 386(9994): 672-9, 2015 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-26211828

RESUMO

BACKGROUND: Catheter ablation is increasingly used to manage atrial fibrillation, but arrhythmia recurrences are common. Adenosine might identify pulmonary veins at risk of reconnection by unmasking dormant conduction, and thereby guide additional ablation to improve arrhythmia-free survival. We assessed whether adenosine-guided pulmonary vein isolation could prevent arrhythmia recurrence in patients undergoing radiofrequency catheter ablation for paroxysmal atrial fibrillation. METHODS: We did this randomised trial at 18 hospitals in Australia, Europe, and North America. We enrolled patients aged older than 18 years who had had at least three symptomatic atrial fibrillation episodes in the past 6 months, and for whom treatment with an antiarrhythmic drug failed. After pulmonary vein isolation, intravenous adenosine was administered. If dormant conduction was present, patients were randomly assigned (1:1) to additional adenosine-guided ablation to abolish dormant conduction or to no further ablation. If no dormant conduction was revealed, randomly selected patients were included in a registry. Patients were masked to treatment allocation and outcomes were assessed by a masked adjudicating committee. Patients were followed up for 1 year. The primary outcome was time to symptomatic atrial tachyarrhythmia after a single procedure in the intention-to-treat population. The trial is registered with ClinicalTrials.gov, number NCT01058980. FINDINGS: Adenosine unmasked dormant pulmonary vein conduction in 284 (53%) of 534 patients. 102 (69·4%) of 147 patients with additional adenosine-guided ablation were free from symptomatic atrial tachyarrhythmia compared with 58 (42·3%) of 137 patients with no further ablation, corresponding to an absolute risk reduction of 27·1% (95% CI 15·9-38·2; p<0·0001) and a hazard ratio of 0·44 (95% CI 0·31-0·64; p<0·0001). Of 115 patients without dormant pulmonary vein conduction, 64 (55·7%) remained free from symptomatic atrial tachyarrhythmia (p=0·0191 vs dormant conduction with no further ablation). Occurrences of serious adverse events were similar in each group. One death (massive stroke) was deemed probably related to ablation in a patient included in the registry. INTERPRETATION: Adenosine testing to identify and target dormant pulmonary vein conduction during catheter ablation of atrial fibrillation is a safe and highly effective strategy to improve arrhythmia-free survival in patients with paroxysmal atrial fibrillation. This approach should be considered for incorporation into routine clinical practice. FUNDING: Canadian Institutes of Health Research, St Jude Medical, Biosense-Webster, and M Lachapelle (Montreal Heart Institute Foundation).


Assuntos
Adenosina , Antiarrítmicos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/efeitos dos fármacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Modelos de Riscos Proporcionais , Veias Pulmonares/cirurgia , Prevenção Secundária , Resultado do Tratamento
13.
J Cardiovasc Electrophysiol ; 27(11): 1337-1343, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27458078

RESUMO

INTRODUCTION: Cardiac resynchronization therapy (CRT) implant procedures are often complex and prolonged, resulting in substantial ionizing radiation (IR) exposure to the patient and operator. We assessed the impact of lower-dose fluoroscopy settings and a sensor-based electromagnetic tracking system (MediGuide™, MDG) on reducing IR exposure during CRT implantation. METHODS: A single-center 2-group cohort study was conducted on 348 consecutive patients, age 66.4 ± 11.0 years, 80.4% male, with CRT implant procedures from 2013 to 2015. Patients were arbitrarily assigned to MDG (N = 239) versus no MDG (N = 109) guidance. Lower-dose fluoroscopy settings were adopted in January 2015 (3 instead of 6 fps; 23 instead of 40 nGy/pulse; N = 101). RESULTS: Overall, MDG was associated with an 82.1% reduction in IR exposure (393 µGray·m2 vs. 2191 µGray·m2 , P < 0.001). Lower-dose fluoroscopy resulted in a 59.5% reduction in IR-exposure without MDG (1055 µGray·m2 vs. 2608 µGray·m2 , P < 0.001) and 81.8% reduction with MDG (108 µGray·m2 vs. 595 µGray·m2 , P < 0.001). Low-dose fluoroscopy combined with MDG was associated with a 95.9% lower exposure to IR when compared to standard fluoroscopy without MDG (108 µGray·m2 vs. 2608 µGray·m2 , P < 0.001). Procedures with MDG were shorter (96 minutes vs. 123 minutes, P < 0.001) and associated with a trend towards a higher success rate (94.6% vs. 89.0%, P = 0.062), with fewer coronary sinus cannulation failures (2.1% vs. 6.4%, P = 0.040). CONCLUSION: Low-dose fluoroscopy settings are highly effective (>50%) in reducing IR exposure during CRT implant procedures. When combined with MDG, >95% reduction in IR exposure is achieved. Moreover, MDG shortens procedural duration and may improve acute procedural outcomes.

14.
J Cardiovasc Electrophysiol ; 27(4): 404-13, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27074775

RESUMO

BACKGROUND: The association between standard parameters from a simple 12-lead ECG (i.e., QRS duration and PR, JT, and QT intervals) and adverse cardiovascular outcomes (cardiovascular mortality, all-cause mortality, arrhythmic mortality, and hospitalizations) in patients with a history of atrial fibrillation (AF) has not been previously studied. METHODS AND RESULTS: A pooled analysis of patient-level data was conducted on 5,436 patients, age 68.2 ± 8.3 years, 34.8% female, with a history of non-permanent AF randomized in AFFIRM and AF-CHF trials. The predictive value of ECG parameters was assessed in AF and sinus rhythm in multivariate Cox regression models. During a follow-up of 40.8 ± 16.3 months, QRS duration >120 milliseconds was independently associated with all-cause mortality (hazard ratio [HR] 1.46, 95% confidence interval [CI; 1.21-1.76] in AF, P < 0.001), cardiovascular mortality (HR 1.75, 95% CI (1.15-2.65) in sinus rhythm, P = 0.009; HR 1.56, 95% CI [1.27-1.93] in AF, P < 0.001), arrhythmic mortality (HR 1.90, 95% CI [1.09-3.32] in sinus, P = 0.024; HR 1.84, 95% CI [1.35-2.51] in AF, P < 0.001), any hospitalization (HR 1.15, 95% CI [1.02-1.29] in AF, P = 0.027), and cardiovascular hospitalization (HR 1.21, 95% CI [1.06-1.37] in AF; P = 0.004). Increased PR interval (>200 milliseconds) was independently associated with cardiovascular (HR 1.56, 95% CI [1.11-2.21], P = 0.010) and arrhythmic (HR 1.91, 95% CI [1.14-3.18], P = 0.004) mortality. The JT and QTc intervals were not predictive of mortality. CONCLUSIONS: Simple parameters from standard ECGs are significantly and independently associated with adverse cardiovascular outcomes in patients with a history of AF.


Assuntos
Fibrilação Atrial/mortalidade , Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial/mortalidade , Morte Súbita Cardíaca/epidemiologia , Eletrocardiografia/métodos , Hospitalização/estatística & dados numéricos , Idoso , Fibrilação Atrial/diagnóstico , Canadá/epidemiologia , Estimulação Cardíaca Artificial/estatística & dados numéricos , Morte Súbita Cardíaca/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Taxa de Sobrevida , Estados Unidos/epidemiologia
15.
J Thromb Thrombolysis ; 41(2): 328-35, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26238769

RESUMO

Warfarin is an oral anticoagulant agent with a narrow therapeutic index. There is a marked inter- and intra-patient variability in warfarin dose requirement. All factors influencing warfarin response are not known and this study aims to evaluate if regular physical activity (RPA) is a determining factor. RPA level was collected with the Stanford Brief Activity Survey in 1064 incident warfarin users, as part of the Quebec Warfarin Cohort (QWC), and with the Global Physical Activity Questionnaire in 618 patients from the Montreal Heart Institute (MHI) Biobank. Linear regression was performed to model relationship of warfarin dose after 3 months of therapy in the QWC with RPA, while controlling for height, weight, age, CYP2C9 (*2 and *3 alleles) and VKORC1 (*2 allele) genotype. Warfarin dose of prevalent users was modeled in the MHI Biobank for replication. A higher level of physical activity was associated with higher doses of warfarin in both cohorts. In the QWC, physical activity could explain 5.4 % (P < 0.001) and 0.9 % (P = 3.23 × 10(-5)) of variance in dose, in univariate and multivariable models, respectively. Similarly, RPA was found to be associated with 1.7 % (P = 0.0012) and 0.5 % (P = 0.0391) of inter-individual variability in warfarin dose requirement before and after adjustment for other covariables, respectively. RPA is associated with higher warfarin dose requirement. The relevance of clinical recommendations on RPA to maintain a steady response to warfarin should be assessed in further studies.


Assuntos
Modelos Biológicos , Atividade Motora , Inquéritos e Questionários , Varfarina/administração & dosagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Citocromo P-450 CYP2C9/genética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Vitamina K Epóxido Redutases/genética
16.
Circulation ; 129(20): 2021-30, 2014 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-24610807

RESUMO

BACKGROUND: This study reports the impact of cardiac resynchronization therapy (CRT) on hospitalizations in patients randomized to implantable cardioverter-defibrillator (ICD) or ICD-CRT in the Resynchronization-Defibrillation for Ambulatory Heart Failure Trial (RAFT). METHODS AND RESULTS: Hospitalization rates and lengths of hospital stay were compared between the 2 groups. At the 18-month follow-up, the numbers of patients hospitalized for any cause were similar in the ICD (n=351, 38.8%) and ICD-CRT (n=331, 30.0%) groups. The number of patients hospitalized for heart failure was significantly lower in the ICD-CRT (n=101, 11.3%) compared with the ICD (n=141, 15.6%; P=0.003) group. The number of patients hospitalized for a device-related indication was similar in the ICD-CRT group (n=147, 16.4%) and ICD group (n=126, 13.9%; P=0.148). The total number of hospitalizations for any cause (n=1448 versus n=1553; P=0.042), any cardiovascular cause (n=667 versus n=790; P=0.017), and any heart failure cause (n=385 versus n=505; P<0.0001) was significantly lower in ICD-CRT group compared with the ICD group, whereas the number of hospitalizations for device-related causes was significantly higher in the ICD-CRT group compared with the ICD group (246 versus 159; P<0.001). Although the reduction in hospitalizations for heart failure in the CRT-ICD group was offset by an increased number of hospitalizations for device-related indications, the length of hospital stay for any cause was significantly shorter in the ICD-CRT group (8.83±13.30 days) compared with the ICD group (9.59±14.40 days; P=0.005). CONCLUSION: ICD-CRT therapy significantly reduces hospitalizations and total days in hospital in patients with New York Heart Association class II/III heart failure compared with ICD therapy despite increased admissions for device-related indications. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00251251.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Hospitalização/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Readmissão do Paciente/estatística & dados numéricos , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Fatores de Risco , Prevenção Secundária
17.
J Cardiovasc Electrophysiol ; 26(12): 1327-32, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26332293

RESUMO

INTRODUCTION: Rate and rhythm control strategies for atrial fibrillation (AF) are not always effective or well tolerated in patients with congestive heart failure (CHF). We assessed reasons for treatment failure, associated characteristics, and effects on survival. METHODS AND RESULTS: A total of 1,376 patients enrolled in the AF-CHF trial were followed for 37  ±  19 months, 206 (15.0%) of whom failed initial therapy leading to crossover. Rhythm control was abandoned more frequently than rate control (21.0% vs. 9.1%, P < 0.0001). Crossovers from rhythm to rate control were driven by inefficacy, whereas worsening heart failure was the most common reason to crossover from rate to rhythm control. In multivariate analyses, failure of rhythm control was associated with female sex, higher serum creatinine, functional class III or IV symptoms, lack of digoxin, and oral anticoagulation. Factors independently associated with failure of rate control were paroxysmal (vs. persistent) AF, statin therapy, and presence of an implantable cardioverter-defibrillator. Crossovers were not associated with cardiovascular mortality (hazard ratio [HR] 1.11 from rhythm to rate control; 95% confidence interval [95% CI, 0.73-1.73]; P = 0.6069; HR 1.29 from rate to rhythm control; 95% CI, 0.73-2.25; P = 0.3793) or all-cause mortality (HR 1.16 from rhythm to rate control, 95% CI [0.79-1.72], P = 0.4444; HR 1.15 from rate to rhythm control, 95% [0.69, 1.91], P = 0.5873). CONCLUSIONS: Rhythm control is abandoned more frequently than rate control in patients with AF and CHF. The most common reasons for treatment failure are inefficacy for rhythm control and worsening heart failure for rate control. Changing strategies does not impact survival.


Assuntos
Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Frequência Cardíaca , Idoso , Antiarrítmicos/uso terapêutico , Anticoagulantes/uso terapêutico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Fibrilação Atrial/mortalidade , Creatinina/sangue , Desfibriladores Implantáveis , Digoxina/uso terapêutico , Progressão da Doença , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Pessoa de Meia-Idade , Fatores Sexuais , Falha de Tratamento
18.
J Cardiovasc Electrophysiol ; 26(5): 509-14, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25727361

RESUMO

BACKGROUND: Hypertension is an established risk factor for new-onset atrial fibrillation (AF). However, the relationship between blood pressure and recurrent AF is less well understood. METHODS AND RESULTS: A pooled analysis of patient-level data from AFFIRM and AF-CHF trials was conducted on all 2,715 patients with paroxysmal or persistent AF, 68 ± 8 years, 66% male, randomized to rhythm control and followed for 40.6 ± 16.5 months. We assessed the impact of a baseline systolic blood pressure (SBP; <120 mmHg [N = 1,008], 120-140 mmHg [N = 930], >140 mmHg [N = 777]) on recurrent AF and proportion of time spent in AF. In patients with LVEF >40% (N = 1,719), SBP was not associated with recurrent AF in multivariate regression analyses (P = 0.752). In contrast, in patients with LVEF ≤40% (N = 996), the AF recurrence rate was higher in those with an SBP >140 mmHg compared to 120-140 mmHg (hazard ratio 1.47; 95% CI [1.12-1.93], P = 0.005). The rate of recurrent AF was similar in patients with SBP <120 mmHg compared to 120-140 mmHg (hazard ratio 1.15; 95% CI [0.92-1.43], P = 0.225). Consistently, the proportion of time spent in AF was not influenced by SBP in patients with LVEF >40% (P = 0.645). However, in patients with LVEF ≤40%, the adjusted mean proportion of time spent in AF was 17.2% if SBP was <120 mmHg, 15.4% for SBP 120-140 mmHg, and 24.0% for SBP >140 mmHg (P = 0.025). CONCLUSION: Systolic blood pressure is an important determinant of recurrent AF and overall AF burden in patients with left ventricular dysfunction (LVEF≤40%) but not in those with preserved ventricular function.


Assuntos
Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Pressão Sanguínea , Hipertensão/complicações , Hipertensão/fisiopatologia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Distribuição de Qui-Quadrado , Intervalo Livre de Doença , Feminino , Humanos , Hipertensão/diagnóstico , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Análise Multivariada , Modelos de Riscos Proporcionais , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
19.
Pacing Clin Electrophysiol ; 38(1): 63-70, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25311868

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) implant procedures are often complex and prolonged, resulting in significant ionizing radiation (IR) exposure to the patient and operator. We report our early experience working with a novel sensor-based electromagnetic tracking system (MediGuide™, MDG, St. Jude Medical Inc., St. Paul, MN, USA), in terms of procedural IR exposure reduction. METHODS AND RESULTS: Information regarding patient demographics, procedural details, procedural duration, and IR exposure were prospectively collected on 130 consecutive CRT procedures performed between January 2013 and January 2014. Sixty procedures were performed with MDG guidance, and 70 were performed without MDG guidance. Despite a nonsignificant trend toward shorter procedure duration with the use of MDG (120 minutes vs 138 minutes with non-MDG, P = 0.088), a 66% reduction in total IR exposure (median 769 µGray · m(2) vs 2,608 µGray · m(2), P < 0.001) was found. This reduction was primarily driven by a >90% reduction in IR dose required to cannulate the coronary sinus (median 80 µGray · m(2) vs 922 µGray · m(2), P < 0.001), and to a lesser extent from a reduction in IR dose required for LV lead placement (median 330 µGray·m(2) vs 737 µGray · m(2), P = 0.059). In addition, a significant learning curve effect was observed with a significantly shorter procedural duration for the last 15 cases compared to the first 15 cases (median 98 minutes vs 175 minutes, P < 0.001). CONCLUSION: The nonfluoroscopic MDG positioning system is associated with a dramatic reduction in exposure to IR during CRT implant procedures, with a 90% decrease in the IR dose required to cannulate the coronary sinus. A steep learning curve was quantified.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Implantação de Prótese/métodos , Lesões por Radiação/prevenção & controle , Idoso , Radiação Eletromagnética , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Cirurgia Assistida por Computador
20.
Pacing Clin Electrophysiol ; 38(7): 784-90, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25682843

RESUMO

BACKGROUND: Fluoroscopic guidance is used to position catheters during cardiac ablation. We evaluated the impact of a novel nonfluoroscopic sensor-guided electromagnetic navigation system (MG) on radiation exposure during catheter ablation of atrial fibrillation (AF) or atrial flutter (AFL). METHODS: A total of 134 consecutive patients referred for ablation of AF (n = 44) or AFL (n = 90) ablation were prospectively enrolled. In one group the MG system was used for nonfluoroscopic catheter positioning, whereas in the conventional group standard fluoroscopy was utilized. Fluoroscopy times were assessed for each stage of procedure and total radiation exposure was quantified. RESULTS: Patient characteristics were similar between the groups. The procedural end point was achieved in all. Median (interquartile range [IQR]) fluoroscopy times were 12.5 minutes (7.6, 17.4) MG group versus 21.5 minutes (15.3, 23.0) conventional group (P < 0.0001) for AF ablation, and 0.8 minutes (0.4, 2.5) MG group versus 9.9 minutes (5.1, 22.5) conventional group (P < 0.0001) for AFL ablation. Median (IQR) total radiation exposure (µGy·m(2)) was 1,107 (906, 2,033) MG group versus 2,835 (1,688, 3,855) conventional group (P = 0.0001) for AF ablation, and 161 (65, 537) MG group versus 1,651 (796, 4,569) conventional group (P < 0.0001) for AFL ablation. No difference in total procedural time was seen. CONCLUSIONS: The use of a novel nonfluoroscopic catheter tracking system is associated with a significant reduction in radiation exposure during AF and AFL ablation (61% and 90% reduction, respectively). In the era of heightened awareness of the importance of radiation reduction, this system represents a safe and efficient tool to decrease radiation exposure during electrophysiological ablation procedures.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/métodos , Exposição à Radiação/análise , Radiografia Intervencionista/instrumentação , Fibrilação Atrial/diagnóstico por imagem , Flutter Atrial/diagnóstico por imagem , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Doses de Radiação , Proteção Radiológica , Radiografia Intervencionista/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA