Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38226697

RESUMO

Gadolinium-based contrast agents (GBCAs) are routinely used in magnetic resonance imaging (MRI). They are essential for choosing the most appropriate medical or surgical strategy for patients with serious pathologies, particularly in oncologic, inflammatory, and cardiovascular diseases. However, GBCAs have been associated with an increased risk of nephrogenic systemic fibrosis in patients with renal failure, as well as the possibility of deposition in the brain, bones, and other organs, even in patients with normal renal function. Research is underway to reduce the quantity of gadolinium injected, without compromising image quality and diagnosis. The next generation of GBCAs will enable a reduction in the gadolinium dose administered. Gadopiclenol is the first of this new generation of GBCAs, with high relaxivity, thus having the potential to reduce the gadolinium dose while maintaining good in vivo stability due to its macrocyclic structure. High-stability and high-relaxivity GBCAs will be one of the solutions for reducing the dose of gadolinium to be administered in clinical practice, while the development of new technologies, including optimization of MRI acquisitions, new contrast mechanisms, and artificial intelligence may help reduce the need for GBCAs. Future solutions may involve a combination of next-generation GBCAs and image-processing techniques to optimize diagnosis and treatment planning while minimizing exposure to gadolinium. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 3.

2.
J Comput Assist Tomogr ; 40(6): 985-990, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27331928

RESUMO

OBJECTIVE: Beyond fat suppression (FS), the efficacy of (fat-water separation or Dixon [FWD]) Dixon imaging in gadolinium-enhanced spine imaging has yet to be validated. This study evaluated enhanced opposed-phase (OP) and fat-only (FO) images along with water-only (WO; FS) images against traditional unenhanced techniques and rated the incremental value of in-phase imaging in patients with presumed neoplastic focal spine lesions. METHODS: A retrospective cohort study of 36 subjects with focal spine lesions imaged with FWD was evaluated qualitatively and quantitatively. RESULTS: Enhanced OP, WO, and FO images were of significant value in detection of osseous lesions, surpassing the lesion conspicuity with conventional techniques both qualitatively and quantitatively, although the impact of in-phase imaging was limited. Water-only imaging performed well for FS. CONCLUSIONS: Contrast-enhanced FO, WO, and OP outperform traditional techniques, providing reliable lesion characterization and highest conspicuity. In-phase imaging offered limited impact on the subjective assessment of enhancement. The added value and robustness of FWD, particularly the unique contrast provided by FO imaging, suggests consideration for routine use for postgadolinium spine imaging.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Água Corporal/diagnóstico por imagem , Doenças da Medula Óssea/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Doenças da Coluna Vertebral/diagnóstico por imagem , Adulto , Idoso , Estudos de Coortes , Meios de Contraste , Feminino , Gadolínio , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
3.
J Comput Assist Tomogr ; 39(3): 329-33, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25978591

RESUMO

OBJECTIVE: We explored how a novel T1-weighted 3-dimensional (3D) fast spin echo (FSE) sequence (Cube; GE, Waukesha, Wis) might outperform conventional 2-dimensional (2D) FSE techniques for contrast-enhanced imaging of the pituitary and parasellar region. METHODS: Ninety-one patients were imaged with 3D Cube and conventional 2D FSE on a 3.0-T magnetic resonance scanner. Two neuroradiologists independently assessed images for anatomical delineation (infundibulum, optic apparatus, and cavernous sinus), degree of artifact, and confidence in lesion definition or exclusion using a 5-point scale. In addition, the readers were asked to rank overall preference. RESULTS: Readers A and B found 3D Cube to be better or equal to 2D FSE in 84% and 86% of the cases. Three-dimensional Cube provided significantly better images than 2D FSE with respect to delineation of the infundibulum (P < 0.0001), cavernous sinus (P < 0.0001), optic apparatus (P = 0.002 for reader A and P = 0.265 for reader B), and fewer artifacts at the sellar floor (P < 0.0001). Three-dimensional Cube provided greater lesion conspicuity or confidence in lesion exclusion (P < 0.0001). CONCLUSIONS: Three-dimensional Cube provides superior quality with thinner slices as well as diminished artifact and can replace conventional 2D FSE sequences for routine evaluations of the pituitary and parasellar region.


Assuntos
Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Hipófise/patologia , Neoplasias Hipofisárias/patologia , Sela Túrcica/patologia , Adolescente , Adulto , Idoso , Algoritmos , Criança , Meios de Contraste , Feminino , Gadolínio , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin , Adulto Jovem
4.
Radiol Clin North Am ; 57(2): 377-395, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30709476

RESUMO

Osseous metastases are the most common spine tumor and increasingly prevalent as advances in cancer treatments allow patients to live longer with their disease. Evidence-based algorithms derive the majority of their data from imaging studies and reports; the radiologist should understand the most current treatments and report in the language of the treatment team for efficient and effective communication and patient care. Advanced imaging techniques such as diffusion-weighted imaging and dynamic contrast-enhanced MRI are increasingly used for diagnosis and problem solving. Radiologists have a growing role in treatment of patients with metastatic disease, performing cement augmentation and tumor ablation.


Assuntos
Diagnóstico por Imagem/métodos , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Humanos , Coluna Vertebral/diagnóstico por imagem
5.
Clin Neurol Neurosurg ; 109(2): 138-45, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16934921

RESUMO

OBJECTIVE: To evaluate the contribution of CT angiography (CTA) in predicting clinical outcome in a broad spectrum of patients presenting with acute neurological deficits suggestive of brain ischemia, to assess its strengths and limitations in this setting, and examine its influence on selection of patients for thrombolytic treatment. PATIENTS AND METHODS: Prospective, observational outcome study of 54 consecutive patients with acute neurological deficits suggestive of brain ischemia who received immediate CTA. Clinical outcome was compared for patients presenting with and without arterial occlusion on CTA. Treatment decisions made by a vascular neurologist blinded to CTA results were compared to CTA cognizant treatment. RESULTS: For patients presenting with slight to moderate neurological deficits, the sensitivity and specificity for predicting good clinical outcome was 0.62 and 0.79, respectively, using the initial NIH Stroke Scale (NIHSS) score alone, and 0.38 and 0.92 if additionally, CTA showed no occlusion. For patients presenting with more severe deficits, the sensitivity and specificity for predicting poor clinical outcome using the NIHSS score alone was 0.79 and 0.60, compared to 0.67 and 0.92 if CTA showed vessel obstruction. CTA correctly identified six stroke mimickers. Selection of patients for thrombolysis made with knowledge of CTA results were more often conservative, and corresponded to CTA blinded decisions in 42/50 cases (84%, r=0.72). CONCLUSIONS: Combining CTA results with the neurological exam allows increased specificity for predicting clinical outcome as compared to predictions based on admission NIH Stroke Scale score alone. Awareness of CTA results was occasionally associated with less aggressive treatment and testing decisions.


Assuntos
Angiografia Cerebral , Infarto Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Anticoagulantes/uso terapêutico , Infarto Cerebral/tratamento farmacológico , Heparina/uso terapêutico , Humanos , Infusões Intra-Arteriais , Infusões Intravenosas , Angiografia por Ressonância Magnética , Exame Neurológico , Variações Dependentes do Observador , Prognóstico , Sensibilidade e Especificidade , Terapia Trombolítica , Ativador de Plasminogênio Tecidual/uso terapêutico
6.
Magn Reson Imaging Clin N Am ; 14(1): 1-15, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16530631

RESUMO

3T MRI is ready to meet the needs of clinical practice. SAR limitations are minimized by technical advances and surface coils are available for all core applications. With appropriate adjustments to scanning protocols, one can master the challenges of scanning at 3T; studies of the brain, spine, chest, abdomen, pelvis, vasculature, and extremities can be consistently higher in quality than are those obtained at 1.5T. The superior studies that are obtainable at 3T have great appeal to clinicians who are sophisticated about MR technology in areas, such as neurology, orthopedics, vascular surgery, and oncology,and encourage a shift in referrals toward practices that invest in higher field technology. The greater sensitivity to magnetic susceptibility offers unique benefits in functional neuroimaging, and available software/hardware packages enhance clinical setting feasibility, which adds a source of new referrals. The greater overall signal of 3T can be manipulated to make scanning more comfortable and with less motion artifact because scan times could be half as long. Spectacular anatomic delineation that is provided by high-definition scanning at true 1024 resolution can improve preoperative assessment and may improve sensitivity to smaller lesions. 3T provides practices with an advantage that is sought increasingly by high field strength purchasers in a competitive market. Only cost considerations stand in the way of the eventual domination of 3T systems in the high field strength market.


Assuntos
Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Desenho de Equipamento , Humanos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Fenômenos Físicos , Física , Avaliação da Tecnologia Biomédica
7.
Mult Scler J Exp Transl Clin ; 2: 2055217316655365, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28607731

RESUMO

OBJECTIVE/BACKGROUND: The majority of multiple sclerosis patients experience impaired walking ability, which impacts quality of life. Timed 25-foot walk is commonly used to gauge gait impairment but results can be broadly variable. Objective biological markers that correlate closely with patients' disability are needed. Diffusion tensor imaging, quantifying fiber tract integrity, might provide such information. In this project we analyzed relationships between timed 25-foot walk, conventional and diffusion tensor imaging magnetic resonance imaging markers. DESIGN/METHODS: A cohort of gait impaired multiple sclerosis patients underwent brain and cervical spinal cord magnetic resonance imaging. Diffusion tensor imaging mean diffusivity and fractional anisotropy were measured on the brain corticospinal tracts and spinal restricted field of vision at C2/3. We analyzed relationships between baseline timed 25-foot walk, conventional and diffusion tensor imaging magnetic resonance imaging markers. RESULTS: Multivariate linear regression analysis showed a statistically significant association between several magnetic resonance imaging and diffusion tensor imaging metrics and timed 25-foot walk: brain mean diffusivity corticospinal tracts (p = 0.004), brain corticospinal tracts axial and radial diffusivity (P = 0.004 and 0.02), grey matter volume (p = 0.05), white matter volume (p = 0.03) and normalized brain volume (P = 0.01). The linear regression model containing mean diffusivity corticospinal tracts and controlled for gait assistance was the best fit model (p = 0.004). CONCLUSIONS: Our results suggest an association between diffusion tensor imaging metrics and gait impairment, evidenced by brain mean diffusivity corticospinal tracts and timed 25-foot walk.

8.
Stroke ; 33(1): 276-8, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11779922

RESUMO

BACKGROUND AND PURPOSE: We sought to evaluate the ability of CT angiography (CTA) to determine vessel occlusion before acute stroke treatment and to predict its impact on patient outcome. METHODS: Consecutive patients with acute focal neurological deficits received immediate brain CTA. Occlusion on CTA was correlated with other neuroimaging studies and clinical outcome. RESULTS: Diagnostic CTA was obtained in 54 patients: catheter angiography (digital subtraction angiography) confirmed the CTA findings in 12 of 14 patients (86%). CTA results were consistent with at least 1 other neuroimaging study in 40 of 50 patients (80%). Patients with occlusion on CTA had significantly worse discharge National Institutes of Health Stroke Scale (NIHSS) score (mean 14.3 versus 4.5, P=0.0023). In multivariate analysis, both CTA-determined presence of occlusion and admission NIHSS score were independent predictors of clinical outcome. CONCLUSIONS: In our study there was good agreement between acute CTA interpretation and subsequent imaging studies. CTA evidence of occlusion correlated strongly and independently with poor clinical outcome. CTA provides relevant data regarding vessel patency in acute stroke, which may be of value in selecting patients for aggressive treatment.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Angiografia Cerebral/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Angiografia Digital/métodos , Isquemia Encefálica/diagnóstico , Humanos , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Angiografia por Ressonância Magnética , Acidente Vascular Cerebral/diagnóstico , Resultado do Tratamento
9.
Clin Imaging ; 38(6): 821-5, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25069752

RESUMO

Our objective was to compare plaque volumes of multidetector computed tomographic images reconstructed using adaptive statistical iterative reconstruction (ASIR), model-based iterative reconstruction (MBIR), and filtered back projection (FBP). We reviewed 25 patients for a total of 50 extremities imaged on the same scanner. Calcified plaque FBP volume (3468.2 ± 2634.8 mm(3)) was higher than ASIR (2548.1 ± 2166.5 mm(3)). Calcified plaque FBP volume was higher than MBIR (mean=2345.7 ± 1935.4 mm(3)). Our findings suggest that traditional FBP methods overestimate disease compared to newer reconstruction methods.


Assuntos
Algoritmos , Efeitos Psicossociais da Doença , Tomografia Computadorizada Multidetectores/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Interface Usuário-Computador , Calcificação Vascular/diagnóstico por imagem , Angiografia/métodos , Humanos , Iopamidol , Doença Arterial Periférica/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
10.
Neuroimaging Clin N Am ; 24(2): 349-64, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24792613

RESUMO

Few tasks in imaging are more challenging than that of optimizing evaluations of the instrumented spine. The authors describe how applying fundamental and more advanced principles to postoperative spine computed tomography and magnetic resonance examinations mitigates the challenges associated with metal implants and significantly improves image quality and consistency. Newer and soon-to-be-available enhancements should provide improved visualization of tissues and hardware as multispectral imaging sequences continue to develop.


Assuntos
Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico , Doenças da Coluna Vertebral/cirurgia , Fusão Vertebral/instrumentação , Tomografia Computadorizada por Raios X/métodos , Artefatos , Humanos , Sensibilidade e Especificidade , Doenças da Coluna Vertebral/diagnóstico
11.
Magn Reson Imaging Clin N Am ; 21(2): 299-320, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23642555

RESUMO

As in the brain, the sensitivity of diffusion-weighted imaging (DWI) to ischemic damage in the spinal cord may provide early identification of infarction. Diffusion anisotropy may enhance the detection and understanding of damage to the long fiber tracts with clinical implications for diseases such as multiple sclerosis and amyotrophic lateral sclerosis and may also yield insight into damage that occurs with spondylotic and traumatic myelopathy. This article reviews the basis for DWI for the evaluation of the spinal cord, osseous, and soft tissues of the spine and reviews the imaging appearance of a variety of disease states.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Doenças da Medula Espinal/patologia , Doenças da Coluna Vertebral/patologia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA