Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Antimicrob Chemother ; 79(7): 1637-1644, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38828950

RESUMO

OBJECTIVES: Exposure of healthcare workers to antibiotics may cause adverse health effects. Results of environmental contamination with antibiotics, obtained by taking surface wipe samples, can be used as an indicator for potential exposure to these sensitizing drugs. The objective was to describe the results of repeated measurements of contamination with antibiotics on multiple surfaces in hospital wards. Standardized needle and syringe preparation techniques and cleaning procedures were used. METHODS: The preparation table and the floor around the waste bin in six wards were sampled and analysed for contamination with the antibiotics amoxicillin, benzylpenicillin, cefotaxime, ceftriaxone, flucloxacillin, meropenem, piperacillin and vancomycin. Sampling was performed in four trials during 8 months. Depending on the outcome of the trials, the cleaning procedure was adapted. Liquid chromatography with tandem mass spectrometry was used for the analysis of the drugs. RESULTS: During the four trials, contamination with all eight antibiotics was omnipresent on all preparation tables and floors in the six wards. The highest contamination was found for amoxicillin (1291 ng/cm2). Changing the cleaning procedure did not reduce the level of contamination. CONCLUSIONS: Surface contamination with the antibiotics was widespread and most probably caused by spillage during the preparation in combination with an ineffective cleaning procedure. Strategies should be developed and implemented by institutions for safe handling of antibiotics to reduce environmental contamination and potential exposure of healthcare workers to these sensitizing drugs.


Assuntos
Antibacterianos , Antibacterianos/análise , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem , Exposição Ocupacional/análise , Hospitais
2.
J Oncol Pharm Pract ; : 10781552231205481, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38115732

RESUMO

INTRODUCTION: Exposure of healthcare workers to hazardous drugs can lead to adverse health effects supporting the importance of a continuous monitoring program, for example, by taking surface wipe samples. The objective was to describe the results of repeated monitoring of contamination with hazardous drugs on multiple surfaces in a hospital pharmacy and at two wards using standardized preparation techniques and cleaning procedures. METHODS: Twelve surfaces in the hospital pharmacy and at two wards were sampled and analyzed for contamination with the hazardous drugs cyclophosphamide, doxorubicin, 5-fluorouracil, gemcitabine, methotrexate, and paclitaxel. The drugs were prepared with a closed-system drug transfer device (CSTD). Sampling of the drugs was performed in four trials during eight months. Liquid chromatography tandem mass spectrometry was used for the analysis of the drugs. RESULTS: During the four trials, contamination with five of the six hazardous drugs was found on half of the surfaces in the pharmacy and in a ward. Seventeen out of 288 possible outcomes were positive (6%), with the biological safety cabinet grate (n = 6) and scanner (n = 5) most frequently contaminated. The highest level of contamination was observed on the pass-thru window (cyclophosphamide: 2.90 ng/cm2) and the touch screen of the Diana device (5-fluorouracil: 2.38 ng/cm2). Both levels were below the action level of 10 ng/cm2. CONCLUSIONS: The long-term use of a CSTD in combination with appropriate cleaning has proven effective in achieving low levels of surface contamination with hazardous drugs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA