Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
eNeuro ; 11(5)2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38627064

RESUMO

Infrared neural stimulation (INS) is a promising area of interest for the clinical application of a neuromodulation method. This is in part because of its low invasiveness, whereby INS modulates the activity of the neural tissue mainly through temperature changes. Additionally, INS may provide localized brain stimulation with less tissue damage. The inferior colliculus (IC) is a crucial auditory relay nucleus and a potential target for clinical application of INS to treat auditory diseases and develop artificial hearing devices. Here, using continuous INS with low to high-power density, we demonstrate the laminar modulation of neural activity in the mouse IC in the presence and absence of sound. We investigated stimulation parameters of INS to effectively modulate the neural activity in a facilitatory or inhibitory manner. A mathematical model of INS-driven brain tissue was first simulated, temperature distributions were numerically estimated, and stimulus parameters were selected from the simulation results. Subsequently, INS was administered to the IC of anesthetized mice, and the modulation effect on the neural activity was measured using an electrophysiological approach. We found that the modulatory effect of INS on the spontaneous neural activity was bidirectional between facilitatory and inhibitory effects. The modulatory effect on sound-evoked responses produced only an inhibitory effect to all examined stimulus intensities. Thus, this study provides important physiological evidence on the response properties of IC neurons to INS. Overall, INS can be used for the development of new therapies for neurological disorders and functional support devices for auditory central processing.


Assuntos
Colículos Inferiores , Raios Infravermelhos , Animais , Colículos Inferiores/fisiologia , Camundongos , Masculino , Estimulação Luminosa/métodos , Estimulação Acústica/métodos , Neurônios/fisiologia , Camundongos Endogâmicos C57BL , Modelos Neurológicos , Potenciais Evocados Auditivos/fisiologia
2.
J Neurosci Methods ; 403: 110048, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38151186

RESUMO

BACKGROUND: Ultrasound stimulation is used to noninvasively stimulate the local and deep areas of the brain. However, the detailed cellular mechanisms of neural activation are still unclear because studies on micro-stimulation at the cellular level are lacking. NEW METHOD: To modulate neural activity at the cellular level, we developed a piezoelectric micromachined ultrasound transducer (PMUT), having circular diaphragms for application on acute brain slice preparations. To monitor neural activities, additionally, we fabricated recording microelectrodes onto the same PMUT device for closed-loop application. RESULTS: To examine the PMUT-driven cellular responses of a brain slice, intracellular calcium signals in individual cells were measured using two calcium indicators. We successfully observed the intracellular responses triggered by the ultrasound of our novel PMUT. In addition, we performed recordings of local field potentials in a brain slice, demonstrating its usefulness as a simultaneous recording interface. COMPARISON WITH EXISTING METHOD(S): Conventional ultrasound stimulators are open-loop systems that risk inducing excessive neural activity because of the absence of neural activity monitoring. In contrast, our PMUT is packaged in a single device with both stimulation and sensor interface for neuromodulation. Further, there are no published reports on in vitro microdevices that can be used for ultrasound stimulation in rodent cortical slices that are several hundred micrometers thick, which maintain the cortical laminar structure and intrinsic neural networks. CONCLUSIONS: Our findings suggest that this novel PMUT device has the potential for being a powerful tool for in vitro brain slice applications and effective closed loop ultrasound stimulation.


Assuntos
Encéfalo , Cálcio , Encéfalo/diagnóstico por imagem , Ultrassonografia , Microeletrodos , Transdutores
3.
J Vis Exp ; (195)2023 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-37306438

RESUMO

A low-cost electroencephalographic (EEG) recording system is proposed here to drive transcranial magnetic stimulation (TMS) of the mouse brain in vivo, utilizing a millimeter-sized coil. Using conventional screw electrodes combined with a custom-made, flexible, multielectrode array substrate, multi-site recording can be carried out from the mouse brain. In addition, we explain how a millimeter-sized coil is produced using low-cost equipment usually found in laboratories. Practical procedures for fabricating the flexible multielectrode array substrate and the surgical implantation technique for screw electrodes are also presented, which are necessary to produce low-noise EEG signals. Although the methodology is useful for recording from the brain of any small animal, the present report focuses on electrode implementation in an anesthetized mouse skull. Furthermore, this method can be easily extended to an awake small animal that is connected with tethered cables via a common adapter and fixed with a TMS device to the head during recording.The present version of the EEG-TMS system, which can include a maximum of 32 EEG channels (a device with 16 channels is presented as an example with fewer channels) and one TMS channel device, is described. Additionally, typical results obtained by the application of the EEG-TMS system to anesthetized mice are briefly reported.


Assuntos
Parafusos Ósseos , Eletroencefalografia , Animais , Camundongos , Encéfalo , Eletrodos , Implantação do Embrião
4.
Front Neurosci ; 16: 824142, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35273476

RESUMO

Ultrasound stimulation is expected to be useful for transcranial local and deep stimulation of the brain, which is difficult to achieve using conventional electromagnetic stimulation methods. Previous ultrasound stimulation experiments have used various types of acute in vitro preparations, including hippocampus slices from rodents and Caenorhabditis elegans tissue. For in vivo preparations, researchers have used the cortices of rodents as targets for transcranial ultrasound stimulation. However, no previous studies have used in vitro ultrasound stimulation in rodent cortical slices to examine the mechanisms of ultrasound-driven central neural circuits. Here we demonstrate the optimal experimental conditions for an in vitro ultrasound stimulation system for measuring activity in brain slices using a multielectrode array substrate. We found that the peak amplitudes of the ultrasound-evoked cortical responses in the brain slices depend on the intensities and durations of the ultrasound stimulation parameters. Thus, our findings provide a new in vitro experimental setup that enables activation of a brain slice via ultrasound stimulation. Accordingly, our results indicate that choosing the appropriate ultrasound waveguide structure and stimulation parameters is important for producing the desired intensity distribution in a localized area within a brain slice. We expect that this experimental setup will facilitate future exploration of the mechanisms of ultrasound-driven neural activity.

5.
Brain Res ; 1796: 148092, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36115587

RESUMO

Transcranial magnetic stimulation (TMS), a minimally/non-invasive method of electromagnetic stimulation of brain tissue, has been shown to be beneficial in clinical therapy for specific neurological diseases and disorders. Magnetic stimulation is also used to modulate human and animal brain activity in basic neuroscience studies. Among experimental animal models, mouse models are particularly popular and uniquely representative of brain disorders in basic neuroscience research. TMS in mouse models may play a substantial role in understanding TMS-induced changes in neural networks and plasticity. Although TMS techniques are widely used to examine rodent disease models, techniques specific for mice using small magnetic stimulators have not been intensively developed. Here, we provide a numerical simulation and a practical method of applying TMS to mice by constructing millimeter-sized TMS coils to deliver a low stimulation intensity while maintaining focality. Our results indicate the TMS coils can produce an electrical field with sufficient magnitude to activate the anesthetized mouse cortex in the presence or absence of the skull in vivo. Our results also show that, immediately after magnetic stimulation, local field and action potentials were reliably observed in a manner that depended on the distance between the coil and the brain, implying even a small coil could reliably evoke cortical activity. Therefore, our results show our millimeter-sized coils could produce electric fields sufficient to alter cortical excitability in mice. These coils could be useful in future preclinical studies to examine detailed mechanisms underlying TMS-induced changes in neural activity of the auditory cortex and other cortical regions.


Assuntos
Córtex Auditivo , Animais , Córtex Auditivo/fisiologia , Encéfalo/fisiologia , Humanos , Fenômenos Magnéticos , Camundongos , Roedores , Estimulação Magnética Transcraniana/métodos
6.
J Neurophysiol ; 106(4): 1901-22, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21697445

RESUMO

Hyperpolarization-activated and cyclic nucleotide-gated (HCN) channels are expressed in dopaminergic (DA) neurons of the ventral tegmental area (VTA) as well as in DA and GABAergic neurons of the substantia nigra (SN). The excitation of DA neurons induced by ethanol has been proposed to result from its enhancing HCN channel current, I(h). Using perforated patch-clamp recordings in rat midbrain slices, we isolated I(h) in these neurons by voltage clamp. We showed that ethanol reversibly increased the amplitude and accelerated the activation kinetics of I(h) and caused a depolarizing shift in its voltage dependence. Using dynamic-clamp conductance injection, we injected artificial I(h) and fluctuating GABAergic synaptic conductance inputs into neurons following block of intrinsic I(h). This demonstrated directly a major role of I(h) in promoting rebound spiking following phasic inhibition, which was enhanced as the kinetics and amplitude of I(h) were changed in the manner induced by ethanol. Similar effects of ethanol were observed on I(h) and firing rate in non-DA, putatively GABAergic interneurons, indicating that in addition to its direct effects on firing, ethanol will produce large changes in the inhibition and disinhibition (via GABAergic interneurons) converging on DA neurons. Thus the overall effects of ethanol on firing of DA cells of the VTA and SN in vivo, and hence on phasic dopamine release in the striatum, appear to be determined substantially by its action on I(h) in both DA cells and GABAergic interneurons.


Assuntos
Canais de Cátion Regulados por Nucleotídeos Cíclicos/fisiologia , Dopamina/fisiologia , Neurônios Dopaminérgicos/efeitos dos fármacos , Etanol/farmacologia , Neurônios GABAérgicos/efeitos dos fármacos , Interneurônios/efeitos dos fármacos , Canais de Potássio/fisiologia , Substância Negra/efeitos dos fármacos , Área Tegmentar Ventral/efeitos dos fármacos , Ácido gama-Aminobutírico/fisiologia , Potenciais de Ação/efeitos dos fármacos , Animais , Neurônios Dopaminérgicos/fisiologia , Neurônios GABAérgicos/fisiologia , Canais Disparados por Nucleotídeos Cíclicos Ativados por Hiperpolarização , Técnicas In Vitro , Interneurônios/fisiologia , Potenciais da Membrana/efeitos dos fármacos , Modelos Neurológicos , Técnicas de Patch-Clamp , Pirimidinas/farmacologia , Ratos , Substância Negra/citologia , Tirosina 3-Mono-Oxigenase/análise , Área Tegmentar Ventral/citologia
7.
PLoS Comput Biol ; 6(9)2010 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-20941393

RESUMO

Fast-spiking (FS) cells in the neocortex are interconnected both by inhibitory chemical synapses and by electrical synapses, or gap-junctions. Synchronized firing of FS neurons is important in the generation of gamma oscillations, at frequencies between 30 and 80 Hz. To understand how these synaptic interactions control synchronization, artificial synaptic conductances were injected in FS cells, and the synaptic phase-resetting function (SPRF), describing how the compound synaptic input perturbs the phase of gamma-frequency spiking as a function of the phase at which it is applied, was measured. GABAergic and gap junctional conductances made distinct contributions to the SPRF, which had a surprisingly simple piecewise linear form, with a sharp midcycle break between phase delay and advance. Analysis of the SPRF showed how the intrinsic biophysical properties of FS neurons and their interconnections allow entrainment of firing over a wide gamma frequency band, whose upper and lower frequency limits are controlled by electrical synapses and GABAergic inhibition respectively.


Assuntos
Sincronização Cortical/fisiologia , Interneurônios/fisiologia , Modelos Neurológicos , Neocórtex/fisiologia , Sinapses/fisiologia , Potenciais Sinápticos/fisiologia , Animais , Distribuição de Qui-Quadrado , Biologia Computacional , Neocórtex/citologia , Técnicas de Patch-Clamp , Ratos , Ratos Wistar , Receptores de GABA/fisiologia
8.
Hear Res ; 377: 208-223, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30981948

RESUMO

Ototoxic-drug-induced hearing disturbances in the auditory periphery are associated with tonotopic map reorganization and neural activity modulation, as well as changes in neural correlates in the central auditory pathway, including the auditory cortex (AC). Previous studies have reported that peripheral auditory impairment induces AC plasticity that involves changes in the balance of excitatory vs. inhibitory synapses, within existing and newly forming patterns of connectivity. Although we know that such plastic changes modulate sound-evoked neural responses and the organization of tonotopic maps in the primary AC (A1), little is known about the effects of peripheral impairment on other frequency-organized AC subfields, such as the anterior auditory field (AAF) and the secondary auditory cortex (A2). Therefore, to examine ototoxic-drug-induced spatiotemporal effects on AC subfields, we measured sound-evoked neural activity in mice before and after the administration of kanamycin sulfate (1 mg/g body weight) and bumetanide (0.05 mg/g body weight), using in vivo transcranial flavoprotein autofluorescence imaging over a 4-week period. At first, ototoxic treatment gradually reduced responses driven by tone bursts with lower- (≤8 kHz) and middle- (e.g., 16 kHz) range frequencies in all AC subfields. Subsequently, response intensities in the A1 recovered to more than 78% of the pre-drug condition; however, in the AAF and A2, they remained significantly lower and were unchanged over 3 weeks. Furthermore, after drug administration, the best frequency (BF) areas of the lower (4 and 8 kHz) and higher (25 and 32 kHz) ranges in all subfields were reduced and shifted to those of a middle range (centered around 16 kHz) during the 3 weeks following drug administration. Our results also indicated that, compared with A1, BF distributions in the AAF and A2 were sharper around 16 kHz 3 weeks after drug administration. These results indicate that the ototoxic-damage-induced tonotopic map reorganizations that occurred in each of the three AC subfields were similar, but that there were subfield-dependent differences in the extent of response intensities and in the activated areas that were responsive to tone bursts with specific frequencies. Thus, by examining cortical reorganization induced by ototoxic drugs, we may contribute to the understanding of how this reorganization can be caused by peripheral damage.


Assuntos
Estimulação Acústica , Córtex Auditivo/diagnóstico por imagem , Mapeamento Encefálico , Flavoproteínas/metabolismo , Perda Auditiva/diagnóstico por imagem , Audição , Microscopia de Fluorescência , Imagem Óptica , Animais , Córtex Auditivo/metabolismo , Córtex Auditivo/fisiopatologia , Limiar Auditivo , Bumetanida , Modelos Animais de Doenças , Potenciais Evocados Auditivos , Feminino , Perda Auditiva/induzido quimicamente , Perda Auditiva/metabolismo , Perda Auditiva/fisiopatologia , Canamicina , Camundongos Endogâmicos C57BL , Plasticidade Neuronal , Tempo de Reação , Fatores de Tempo
9.
Brain Res ; 1721: 146312, 2019 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-31323198

RESUMO

The local application of electrical currents to the cortex is one of the most commonly used techniques to activate neurons, and this intracortical stimulation (ICS) could potentially lead to new types of neuroprosthetic devices that can be directly applied to the cortex. To identify whether ICS-activated circuits are physiological vs. profoundly artificial, it is necessary to record in vivo the responses of the same neuronal population to both natural sensory stimuli and artificial electric stimuli. However, few studies have extensively reported simultaneous electrophysiological recordings combined with ICS. Here, we evaluated the similarity between sound- and ICS-driven cortical response patterns in different cortical layers. In the mouse auditory cortex, we performed laminar recordings using 16-channel silicon electrodes and ICS using sharp glass-pipette electrodes containing biocytin for layer identification. In different cortical depths, short current pulses were delivered in vivo to mice under urethane anesthesia. For the recorded data, we mainly analyzed properties of local field potentials and current source densities (CSDs). We demonstrated that electrical stimulation evoked different excitation patterns according to the stimulated cortical layer; responses to electric stimuli in layer 4 were most likely to mimic acoustic responses. Next, we proposed a CSD-based stimulation method to artificially synthesize sound-driven responses, using an approximation method associated with a linear combination of CSD patterns electrically stimulated in the different cortical layers. The result indicates that synthesized responses were consistent with the canonical model of sound processing. Using these approaches, we provide a new technique in which natural sound-driven responses can be mimicked by well-designed computational stimulation pattern sequences in a layer-dependent manner. These findings may aid in the future development of an electrical stimulation methodology for a cortical prosthesis.


Assuntos
Córtex Auditivo/fisiologia , Percepção Auditiva/fisiologia , Potenciais Evocados Auditivos/fisiologia , Estimulação Acústica/métodos , Acústica , Animais , Encéfalo/fisiologia , Estimulação Elétrica/métodos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Microeletrodos , Neurônios/fisiologia , Som
10.
J Neural Eng ; 16(6): 066014, 2019 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-31642445

RESUMO

OBJECTIVE: Single coil-based systems for magnetic stimulation are widely used for neurostimulation in neuroscience research and clinical treatment of neurological diseases. However, parallelization of magnetic stimulation with multiple coils may generate far greater potential than a single coil, and could thus expand the scope of brain area stimulation. Therefore, we examined whether a multiple coil-based system could improve the effectiveness and focality of conventional single coil-based magnetic stimulation. APPROACH: We designed and tested a micromagnetic stimulation (µMS) device with multiple submillimeter-sized coils as a possible substitute for one large coil. Our design concept is spatially-distributed stimulation strategy involving the small number of coils to be able to mimic desired electric field profiles. To this end, the cost function of the error between the desired and coil-induced electric fields was firstly calculated, and coil currents were repetitively estimated to achieve the smaller number of coils under a certain criterion: a minimum error with spatial sparsity. Using these approaches, we evaluated the capability of our multi-channel µMS via numerical simulations and demonstrated responsive results in animal experiments. MAIN RESULTS: Our approach can enhance control of neural excitation and improve the concentration of the excitation field induced by magnetic stimulation with reduced power consumption. Furthermore, in vivo electrophysiological recordings of mouse brain performed to evaluate our proposed approach for brain stimulation demonstrated experimentally that our multi-channel µMS device can yield more effective stimulation than the single-channel device. In addition, our device permitted electronic spatial adjustment of the stimulus shape and location without moving the coils. SIGNIFICANCE: The development of new multichannel µMS-based therapeutic approaches may be useful because the µMS affects only a restricted brain area. Indeed, the small size of micro-coils and their finer focality with multichannel contribution might be suitable for chronic use, which is difficult using conventional large transcranial magnetic stimulation (TMS) with simple round or figure-eight coils. Thus, our findings support new opportunities to explore magnetic stimulation as a therapeutic approach for neurological disorders.


Assuntos
Córtex Auditivo/fisiologia , Desenho de Equipamento/métodos , Análise em Microsséries/métodos , Estimulação Magnética Transcraniana/métodos , Animais , Encéfalo/fisiologia , Campos Eletromagnéticos , Desenho de Equipamento/instrumentação , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Análise em Microsséries/instrumentação , Roedores , Estimulação Magnética Transcraniana/instrumentação
11.
IEEE Trans Biomed Eng ; 65(6): 1301-1310, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-28880154

RESUMO

OBJECTIVE: Recent studies have reported that micromagnetic stimulation ( MS), which can activate neurons and neural networks via submillimeter inductors, may address several limitations of conventional magnetic stimulation methods. Previous studies have examined the effects of MS on single neurons, yet little is known about how MS can affect brain tissue including local neural networks. Here, we propose a new, readily available implantable MS system and computationally and experimentally evaluate its validity. METHODS: We conducted numerical calculations and experiments to evaluate the physical characteristics, including magnetic flux density, temperature, coil impedance, and structural integrity of the flexible board supporting the MS coils. We then compared sound- and MS-driven neural responses in the mouse auditory cortex using flavoprotein autofluorescence imaging. RESULTS: Our system successfully activated neural tissue, and we observed activity propagation in local neural networks on the brain surface beyond restricted activation of single neurons. Examining the relationships between stimulation parameters and response characteristics, we found that stimulation amplitude and pulse width were the two most important parameters to effectively induce neural activity. CONCLUSION: Our MS device has sufficient potential to drive the brain as an implantable magnetic stimulator for basic neuroscience and clinical applications, although further investigation is required. SIGNIFICANCE: MS can selectively drive and modulate activity in local neural network even at an in vivo tissue level.


Assuntos
Córtex Auditivo/fisiologia , Estimulação Elétrica/instrumentação , Próteses Neurais , Imagem Óptica/métodos , Processamento de Sinais Assistido por Computador , Animais , Imãs , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Desenho de Prótese
12.
Neuroscience ; 371: 346-370, 2018 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-29246784

RESUMO

Magnetic stimulation is widely used in neuroscience research and clinical treatment. Despite recent progress in understanding the neural modulation mechanism of conventional magnetic stimulation methods, the physiological mechanism at the cortical microcircuit level is not well understood due to the poor stimulation focality and large electric artifact in the recording. To overcome these issues, we used a sub-millimeter-sized coil (micro-coil) to stimulate the mouse auditory cortex in vivo. To determine the mechanism, we conducted the first direct electrophysiological recording of micro-coil-driven neural responses at multiple sites on the horizontal surface and laminar areas of the auditory cortex. The laminar responses of local field potentials (LFPs) to the magnetic stimulation reached layer 6, and the spatiotemporal profiles were very similar to those of the acoustic stimulation, suggesting the activation of the same cortical microcircuit. The horizontal LFP responses to the magnetic stimulation were evoked within a millimeter-wide area around the stimulation coil. The activated cortical area was dependent on the coil orientation, providing useful information on the effective position of the coil relative to the brain surface for modulating cortical circuitry activity. In addition, numerical calculation of the induced electric field in the brain revealed that the inhomogeneity of the horizontal electric field to the surface is critical for micro-coil-induced cortical activation. The results suggest that our micro-coil technique has the potential to be used as a chronic, less-invasive and highly focal neuro-stimulator, and is useful for investigating microcircuit responses to magnetic stimulation for clinical treatment.


Assuntos
Córtex Auditivo/fisiologia , Campos Eletromagnéticos , Estimulação Acústica , Animais , Percepção Auditiva/fisiologia , Equipamentos e Provisões Elétricas , Feminino , Masculino , Camundongos Endogâmicos C57BL , Microeletrodos , Vias Neurais/fisiologia , Imagem Óptica , Processamento de Sinais Assistido por Computador , Transmissão Sináptica/fisiologia
13.
J Neurosci Methods ; 293: 77-85, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-28851513

RESUMO

BACKGROUND: Chronic neural recording in freely moving animals is important for understanding neural activities of cortical neurons associated with various behavioral contexts. In small animals such as mice, it has been difficult to implant recording electrodes into exact locations according to stereotactic coordinates, skull geometry, or the shape of blood vessels. The main reason for this difficulty is large individual differences in the exact location of the targeted brain area. NEW METHODS: We propose a new electrode implantation procedure that is combined with transcranial flavoprotein fluorescence imaging. We demonstrate the effectiveness of this method in the auditory cortex (AC) of mice. RESULTS: Prior to electrode implantation, we executed transcranial flavoprotein fluorescence imaging in anesthetized mice and identified the exact location of AC subfields through the skull in each animal. Next, we surgically implanted a microdrive with a tungsten electrode into exactly the identified location. Finally, we recorded neural activity in freely moving conditions and evaluated the success rate of recording auditory responses. COMPARISON WITH EXISTING METHOD(S): These procedures dramatically improved the success rate of recording auditory responses from 21.1% without imaging to 100.0% with imaging. We also identified large individual differences in positional relationships between sound-driven response areas and the squamosal suture or blood vessels. CONCLUSIONS: Combining chronic electrophysiology with transcranial flavoprotein fluorescence imaging before implantation enables the realization of reliable subfield-targeted neural recording from freely moving small animals.


Assuntos
Córtex Auditivo/fisiologia , Córtex Auditivo/cirurgia , Eletrodos Implantados , Flavoproteínas/metabolismo , Imagem Óptica/métodos , Estimulação Acústica , Potenciais de Ação , Animais , Córtex Auditivo/anatomia & histologia , Percepção Auditiva/fisiologia , Variação Biológica Individual , Feminino , Masculino , Camundongos Endogâmicos C57BL , Neurônios/fisiologia , Ratos Wistar
14.
Front Aging Neurosci ; 9: 395, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29311894

RESUMO

The prevalence of tinnitus is known to increase with age. The age-dependent mechanisms of tinnitus may have important implications for the development of new therapeutic treatments. High doses of salicylate can be used experimentally to induce transient tinnitus and hearing loss. Although accumulating evidence indicates that salicylate induces tinnitus by directly targeting neurons in the peripheral and central auditory systems, the precise effect of salicylate on neural networks in the auditory cortex (AC) is unknown. Here, we examined salicylate-induced changes in stimulus-driven laminar responses of AC slices with salicylate superfusion in young and aged senescence-accelerated-prone (SAMP) and -resistant (SAMR) mice. Of the two strains, SAMP1 is known to be a more suitable model of presbycusis. We recorded stimulus-driven laminar local field potential (LFP) responses at multi sites in AC slice preparations. We found that for all AC slices in the two strains, salicylate always reduced stimulus-driven LFP responses in all layers. However, for the amplitudes of the LFP responses, the two senescence-accelerated mice (SAM) strains showed different laminar properties between the pre- and post-salicylate conditions, reflecting strain-related differences in local circuits. As for the relationships between auditory brainstem response (ABR) thresholds and the LFP amplitude ratios in the pre- vs. post-salicylate condition, we found negative correlations in layers 2/3 and 4 for both older strains, and in layer 5 (L5) in older SAMR1. In contrast, the GABAergic agonist muscimol (MSC) led to positive correlations between ABR thresholds and LFP amplitude ratios in the pre- vs. post-MSC condition in younger SAM mice from both strains. Further, in younger mice, salicylate decreased the firing rate in AC L4 pyramidal neurons. Thus, salicylate can directly reduce neural excitability of L4 pyramidal neurons and thereby influence AC neural circuit activity. That we observed age-dependent effects of salicylate and varied GABAergic sensitivity in the AC among mouse strains with hearing loss implies that potential therapeutic mechanisms for tinnitus may operate differently in young vs. aged subjects. Therefore, scientists developing new therapeutic modalities for tinnitus treatment should consider using both aged and young animals.

15.
Brain Res ; 1659: 96-112, 2017 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-28119054

RESUMO

To examine local network properties of the mouse auditory cortex in vitro, we recorded extracellular spatiotemporal laminar profiles driven by short electric local stimulation on a planar multielectrode array substrate. The recorded local field potentials were subsequently evaluated using current source density (CSD) analysis to identify sources and sinks. Current sinks are thought to be an indicator of net synaptic current in the small volume of cortex surrounding the recording site. Thus, CSD analysis combined with multielectrode arrays enabled us to compare mean synaptic activity in response to small current stimuli on a layer-by-layer basis. We also used senescence-accelerated mice (SAM), some strains of which show earlier onset of age-related hearing loss, to examine the characteristic spatiotemporal CSD profiles stimulated by electrodes in specific cortical layers. Thus, the CSD patterns were classified into several clusters based on stimulation sites in the cortical layers. We also found some differences in CSD patterns between the two SAM strains in terms of aging according to principle component analysis with dimension reduction. For simultaneous two-site stimulation, we modeled the obtained CSD profiles as a linear superposition of the CSD profiles to individual single-site stimulation. The model analysis indicated the nonlinearity of spatiotemporal integration over stimulus-driven activity in a layer-specific manner. Finally, on the basis of these results, we discuss the auditory cortex local network properties and the effects of aging on these mouse strains.


Assuntos
Córtex Auditivo/fisiologia , Envelhecimento/fisiologia , Animais , Análise por Conglomerados , Estimulação Elétrica , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Modelos Lineares , Masculino , Camundongos Endogâmicos C57BL , Camundongos Mutantes , Microeletrodos , Análise de Componente Principal , Processamento de Sinais Assistido por Computador , Técnicas de Cultura de Tecidos
16.
Hear Res ; 351: 98-115, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28637591

RESUMO

Salicylate is the active ingredient in aspirin, and in high-doses it is used as an experimental tool to induce transient hearing loss, tinnitus, and hyperacusis. These salicylate-induced perceptual disturbances are associated with tonotopic-map reorganization and neural activity modulation, and such neural correlates have been examined in the central auditory pathway, including the auditory cortex (AC). Although previous studies have reported that salicylate induces increases in noise-burst-evoked neural responses and reorganization of tonotopic maps in the primary AC, little is known about the effects of salicylate on other frequency-organized AC subfields such as the anterior auditory, secondary auditory, and dorsomedial fields. Therefore, to examine salicylate-induced spatiotemporal effects on AC subfields, we measured sound-evoked neural activity in mice before and after the administration of sodium salicylate (SS, 200 mg/kg), using flavoprotein auto-fluorescence imaging. SS-treatment gradually reduced responses driven by tone-bursts with lower (≤8 kHz) and higher (≥25 kHz) frequencies over 3 h, whereas evoked responses to tone-bursts within middle-range frequencies (e.g., 12 and 16 kHz) were sustained and unchanged in the four subfields. Additionally, in each of the four subfields, SS-treatment induced similar reorganization of tonotopic maps, and the response areas selectively driven by the middle-range frequencies were profoundly expanded. Our results indicate that the SS-induced tonotopic map reorganizations in each of the four AC subfields were similar, and only the extent of the activated areas responsive to tone-bursts with specific frequencies was subfield-dependent. Thus, we expect that examining cortical reorganization induced by SS may open the possibility of new treatments aimed at altering cortical reorganization into the normative functional organization.


Assuntos
Córtex Auditivo/fisiopatologia , Mapeamento Encefálico/métodos , Potenciais Evocados Auditivos , Transtornos da Audição/fisiopatologia , Imagem Óptica , Salicilato de Sódio , Zumbido/fisiopatologia , Estimulação Acústica , Animais , Córtex Auditivo/metabolismo , Modelos Animais de Doenças , Flavoproteínas/metabolismo , Transtornos da Audição/induzido quimicamente , Transtornos da Audição/diagnóstico por imagem , Transtornos da Audição/metabolismo , Masculino , Camundongos Endogâmicos C57BL , Fatores de Tempo , Zumbido/induzido quimicamente , Zumbido/diagnóstico por imagem , Zumbido/metabolismo
17.
Hear Res ; 339: 69-79, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27321205

RESUMO

Anesthesia affects central auditory processing. However, it is unclear to what extent the choice of anesthetic agent affects neural responses to sound stimulation. A mixture of three anesthetics (medetomidine, midazolam and butorphanol; MMB) was recently developed as an alternative to ketamine owing to the latter's addictive potential, yet the effect of this combination of anesthetics on neural responses is not known. Here, we compared the spontaneous activity, tuning properties and temporal responses of primary auditory cortical neurons under these two anesthetic conditions, using electrophysiological and flavoprotein autofluorescence imaging methods. Frequency tuning properties were not significantly different between ketamine and MMB anesthesia. However, neural activity under MMB showed decreases in the spontaneous and tone-evoked firing rates in a layer-dependent manner. Moreover, the temporal response patterns were also different between the anesthetics in a layer-dependent manner, which may reflect differences in the anesthetic mechanisms. These results demonstrated how response properties in the primary auditory cortex are affected by the choice of anesthesia.


Assuntos
Córtex Auditivo/efeitos dos fármacos , Butorfanol/administração & dosagem , Ketamina/administração & dosagem , Medetomidina/administração & dosagem , Midazolam/administração & dosagem , Neurônios/efeitos dos fármacos , Anestesia , Anestésicos/administração & dosagem , Anestésicos Dissociativos/administração & dosagem , Animais , Córtex Auditivo/fisiologia , Eletrofisiologia , Flavoproteínas/metabolismo , Audição , Masculino , Neurônios/fisiologia , Ratos , Ratos Wistar , Fatores de Tempo , Xilazina/administração & dosagem
18.
Neurosci Lett ; 633: 189-195, 2016 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-27641319

RESUMO

The effects of anesthesia on the functional auditory characteristics of cortical neurons, such as spatial and temporal response properties, vary between an anesthetized and an awake subject. However, studies have shown that an appropriate anesthetic method that approaches the awake condition is still useful because of its greater stability and controllability. The present study compared neural response properties from two core fields of the mouse auditory cortex under three anesthetic conditions: urethane; ketamine and xylazine hydrochloride (KX) mixture; and a combination of medetomidine, midazolam, and butorphanol (MMB). To measure sound stimulation in vivo, we recorded flavoprotein-autofluorescent images of endogenous green fluorescence. Under all conditions, fluorescence changes in auditory core subfields in response to tones were observed, and response properties, such as peak intensity, latency, duration, and activated areas were analyzed. Results showed larger response peak intensity, latency, and duration in the core subfields under urethane compared with KX and MMB, with no significant differences between KX and MMB. Conversely, under KX anesthesia the activated areas showed characteristic response properties in a subfield-dependent manner. These results demonstrated the varied effects of anesthesia on response properties in the core subfields of the auditory cortex.


Assuntos
Anestésicos Combinados/farmacologia , Córtex Auditivo/efeitos dos fármacos , Flavoproteínas/metabolismo , Estimulação Acústica , Animais , Córtex Auditivo/fisiologia , Butorfanol/farmacologia , Ketamina/farmacologia , Masculino , Medetomidina/farmacologia , Camundongos Endogâmicos C57BL , Midazolam/farmacologia , Imagem Óptica , Uretana/farmacologia , Xilazina/farmacologia
19.
IEEE Trans Biomed Eng ; 50(2): 241-8, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12665038

RESUMO

The capability for multisite stimulation is one of the biggest potential advantages of microelectrode arrays (MEAs). There remain, however, several technical problems which have hindered the development of a practical stimulation system. An important design goal is to allow programmable multisite stimulation, which produces minimal interference with simultaneous extracellular and patch or whole cell clamp recording. Here, we describe a multisite stimulation and recording system with novel interface circuit modules, in which preamplifiers and transistor transistor logic-driven solid-state switching devices are integrated. This integration permits PC-controlled remote switching of each substrate electrode. This allows not only flexible selection of stimulation sites, but also rapid switching of the selected sites between stimulation and recording, within 1.2 ms. This allowed almost continuous monitoring of extracellular signals at all the substrate-embedded electrodes, including those used for stimulation. In addition, the vibration-free solid-state switching made it possible to record whole-cell synaptic currents in one neuron, evoked from multiple sites in the network. We have used this system to visualize spatial propagation patterns of evoked responses in cultured networks of cortical neurons. This MEA-based stimulation system is a useful tool for studying neuronal signal processing in biological neuronal networks, as well as the process of synaptic integration within single neurons.


Assuntos
Potenciais de Ação/fisiologia , Estimulação Elétrica/instrumentação , Potenciais da Membrana/fisiologia , Microeletrodos , Rede Nervosa/fisiologia , Neurônios/fisiologia , Animais , Artefatos , Células Cultivadas , Estimulação Elétrica/métodos , Eletrofisiologia/instrumentação , Eletrofisiologia/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Potenciais Evocados/fisiologia , Espaço Extracelular/fisiologia , Córtex Motor/embriologia , Córtex Motor/fisiologia , Técnicas de Patch-Clamp/instrumentação , Técnicas de Patch-Clamp/métodos , Ratos , Ratos Wistar , Sensibilidade e Especificidade
20.
Phys Rev E Stat Nonlin Soft Matter Phys ; 65(2 Pt 1): 021901, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11863557

RESUMO

This study provides a method for calculating first-order approximations of the Lyapunov exponents of systems with discontinuity in the presence of noise in order to characterize the stability of motions in those systems. This paper in particular illustrates the results of the ways in which noise influences period-doubling bifurcation in the parameter space of an integrate-and-fire model with a periodically modulated reset level. For evaluating a stochastic version of period-doubling bifurcation, the first-passage-time problem of the Ornstein-Uhlenbeck process is used to define a Markov operator governing the transition of a reset-level phase density. The results on the stochastic bifurcation are thus compared with numerical computations of angles and moduli of eigenvalues of the Markov operator that describes the firing properties of the model.


Assuntos
Modelos Neurológicos , Fenômenos Biofísicos , Biofísica , Eletrofisiologia , Cadeias de Markov , Neurônios/fisiologia , Processos Estocásticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA