Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 217
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Clin Radiol ; 79(2): 117-123, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37989667

RESUMO

AIM: To evaluate variation in magnetic resonance imaging (MRI) technique and reporting of rectal cancer staging examinations across the UK. MATERIALS AND METHODS: A retrospective, multi-centre audit was undertaken of imaging protocols and information documented within consecutive MRI rectal cancer reports between March 2020 and August 2021, which were compared against American and European guidelines. Inclusion criteria included histologically proven rectal adenocarcinoma and baseline staging MRI rectum only. RESULTS: Fully anonymised data from 924 MRI reports by 78 radiologists at 24 centres were evaluated. Thirty-two per cent of radiologists used template reporting, but these reports offered superior documentation of 13 out of 18 key tumour features compared to free-text reports including T-stage, relation to peritoneal reflection and mesorectal fascia (MRF), nodal status, and presence of extramural venous invasion (EMVI; p<0.027 in each). There was no significant differences in the remaining five features. Across all tumour locations, the tumour relationship to the MRF, the presence of EMVI, and the presence of tumour deposits were reported in 79.5%, 85.6%, and 44% of cases, respectively, and tumour, nodal, and distant metastatic stage documented in 94.4%, 97.7%, and 78.3%. In low rectal tumours, the relationship to the anal sphincter complex was reported in only 54.6%. CONCLUSION: Considerable variation exists in rectal cancer MRI acquisition and reporting in this sample of UK centres. Inclusion of key radiological features in reports must be improved for risk stratification and treatment decisions. Template reporting is superior to free-text reporting. Routine adoption of standardised radiology practices should now be considered to improve standards to facilitate personalised precision treatment for patients to improve outcomes.


Assuntos
Radiologia , Neoplasias Retais , Humanos , Estudos Retrospectivos , Neoplasias Retais/patologia , Imageamento por Ressonância Magnética/métodos , Reino Unido , Estadiamento de Neoplasias , Invasividade Neoplásica/patologia
2.
Clin Radiol ; 76(10): 748-762, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33579518

RESUMO

The incidence of gastrointestinal (GI) malignancy is increasing worldwide. In particular, there is a concerning rise in incidence of GI cancer in younger adults. Direct endoscopic visualisation of luminal tumour sites requires invasive procedures, which are associated with certain risks, but remain necessary because of limitations in current imaging techniques and the continuing need to obtain tissue for diagnosis and genetic analysis; however, management of GI cancer is increasingly reliant on non-invasive, radiological imaging to diagnose, stage, and treat these malignancies. Oesophageal, gastric, and colorectal malignancies require specialist investigation and treatment due to the complex nature of the anatomy, biology, and subsequent treatment strategies. As cancer imaging techniques develop, many opportunities to improve tumour detection, diagnostic accuracy and treatment monitoring present themselves. This review article aims to report current imaging practice, advances in various radiological modalities in relation to GI luminal tumour sites and describes opportunities for GI radiologists to improve patient outcomes.


Assuntos
Neoplasias Colorretais/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Gástricas/diagnóstico por imagem , Humanos
3.
Clin Radiol ; 75(4): 308-315, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31836179

RESUMO

AIM: To evaluate the association between the image quality of cancer staging whole-body magnetic resonance imaging (WB-MRI) and patient demographics, distress, and perceived scan burden. MATERIALS AND METHODS: A sample of patients recruited prospectively to multicentre trials comparing WB-MRI with standard scans for staging lung and colorectal cancer were invited to complete two questionnaires. The baseline questionnaire, administered at recruitment, collated data on demographics, distress and co-morbidity. The follow-up questionnaire, completed after staging investigations, measured perceived WB-MRI scan burden (scored 1 low to 7 high). WB-MRI anatomical coverage, and technical quality was graded by a radiographic technician and grading combined to categorise the scan as "optimal", "sub-optimal" or "degraded". A radiologist categorised 30 scans to test interobserver agreement. Data were analysed using the chi-square, Fisher's exact, t-tests, and multinomial regression. RESULTS: One hundred and fourteen patients were included in the study (53 lung, 61 colorectal; average age 65.3 years, SD=11.8; 66 men [57.9%]). Overall, 45.6% (n=52), scans were classified as "optimal" quality, 39.5% (n=45) "sub-optimal", and 14.9% (n=17) as "degraded". In adjusted analyses, greater deprivation level and higher patient-reported scan burden were both associated with a higher likelihood of having a sub-optimal versus an optimal scan (odds ratio [OR]: 4.465, 95% confidence interval [CI]: 1.454 to 13.709, p=0.009; OR: 1.987, CI: 1.153 to 3.425, p=0.013, respectively). None of the variables predicted the likelihood of having a degraded scan. CONCLUSIONS: Deprivation and patients' perceived experience of the WB-MRI are related to image quality. Tailored protocols and individualised patient management before and during WB-MRI may improve image quality.


Assuntos
Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Pacientes/psicologia , Estresse Psicológico/complicações , Imagem Corporal Total/métodos , Idoso , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Garantia da Qualidade dos Cuidados de Saúde , Inquéritos e Questionários
4.
Clin Radiol ; 74(5): 346-356, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30803815

RESUMO

Machine learning is now being increasingly employed in radiology to assist with tasks such as automatic lesion detection, segmentation, and characterisation. We are currently involved in an National Institute of Health Research (NIHR)-funded project, which aims to develop machine learning methods to improve the diagnostic performance and reduce the radiology reading time of whole-body magnetic resonance imaging (MRI) scans, in patients being staged for cancer (MALIBO study). We describe here the main challenges we have encountered during the course of this project. Data quality and uniformity are the two most important data traits to be considered in clinical trials incorporating machine learning. Robust data pre-processing and machine learning pipelines have been employed in MALIBO, a task facilitated by the now freely available machine learning libraries and toolboxes. Another important consideration for achieving the desired clinical outcome in MALIBO, was to effectively host the resulting machine learning output, along with the clinical images, for reading in a clinical environment. Finally, a range of legal, ethical, and clinical acceptance issues should be considered when attempting to incorporate computer-assisting tools into clinical practice. The road from translating computational methods into potentially useful clinical tools involves an analytical, stepwise adaptation approach, as well as engagement of a multidisciplinary team.


Assuntos
Aprendizado de Máquina , Imageamento por Ressonância Magnética/métodos , Imagem Corporal Total/métodos , Algoritmos , Humanos , Estudos Multicêntricos como Assunto , Neoplasias/diagnóstico , Estudos Observacionais como Assunto
5.
Clin Radiol ; 74(10): 814.e9-814.e19, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31376918

RESUMO

AIM: To investigate whether subjective radiologist grading of motility on magnetic resonance enterography (MRE) is as effective as software quantification, and to determine the combination of motility metrics with the strongest association with symptom severity. MATERIALS AND METHODS: One hundred and five Crohn's disease patients (52 male, 53 female, 16-68 years old, mean age 34 years old) recruited from two sites underwent MRE, including a 20 second breath-hold cine motility sequence. Each subject completed a Harvey-Bradshaw Index (HBI) symptom questionnaire. Five features within normally appearing bowel were scored visually by two experienced radiologists, and then quantified using automated analysis software, including (1) mean motility, (2) spatial motility variation, (3) temporal motility variation, (4) area of motile bowel, (5) intestinal distension. Multivariable linear regression derived the combination of features with the highest association with HBI score. RESULTS: The best automated metric combination was temporal variation (p<0.05) plus area of motile bowel (p<0.05), achieving an R2 adjusted value of 0.036. Spatial variation was also associated with symptoms (p<0.05, R2 adjusted = 0.034); however, when visually assessed by radiologists, none of the features had a significant relationship with the HBI score. CONCLUSION: Software quantified temporal and spatial variability in bowel motility are associated with abdominal symptoms in Crohn's disease. Subjective radiologist assessment of bowel motility is insufficient to detect aberrant motility. Automated analysis of motility patterns holds promise as an objective biomarker for aberrant physiology underlying symptoms in enteric disorders.


Assuntos
Doença de Crohn/diagnóstico por imagem , Motilidade Gastrointestinal/fisiologia , Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Doença de Crohn/fisiopatologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Intestino Delgado/fisiopatologia , Masculino , Pessoa de Meia-Idade , Radiologistas , Índice de Gravidade de Doença , Software , Adulto Jovem
6.
Clin Radiol ; 78(3): 166-167, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36642647
8.
Eur Radiol ; 27(6): 2570-2582, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27757521

RESUMO

OBJECTIVES: To develop guidelines describing a standardised approach to patient preparation and acquisition protocols for magnetic resonance imaging (MRI), computed tomography (CT) and ultrasound (US) of the small bowel and colon, with an emphasis on imaging inflammatory bowel disease. METHODS: An expert consensus committee of 13 members from the European Society of Gastrointestinal and Abdominal Radiology (ESGAR) and European Society of Paediatric Radiology (ESPR) undertook a six-stage modified Delphi process, including a detailed literature review, to create a series of consensus statements concerning patient preparation, imaging hardware and image acquisition protocols. RESULTS: One hundred and fifty-seven statements were scored for agreement by the panel of which 129 statements (82 %) achieved immediate consensus with a further 19 (12 %) achieving consensus after appropriate modification. Nine (6 %) statements were rejected as consensus could not be reached. CONCLUSIONS: These expert consensus recommendations can be used to help guide cross-sectional radiological practice for imaging the small bowel and colon. KEY POINTS: • Cross-sectional imaging is increasingly used to evaluate the bowel • Image quality is paramount to achieving high diagnostic accuracy • Guidelines concerning patient preparation and image acquisition protocols are provided.


Assuntos
Doenças do Colo/patologia , Doenças Inflamatórias Intestinais/patologia , Intestino Delgado/patologia , Adulto , Criança , Consenso , Estudos Transversais , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Inquéritos e Questionários , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Ultrassonografia/métodos
10.
Clin Radiol ; 70(10): 1104-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26145187

RESUMO

AIM: To determine the detection rates and positive predictive value (PPV) of computed tomography (CT) colonography (CTC) according to the magnitude of faecal occult blood test (FOBt) positivity. MATERIALS AND METHODS: Anonymised data from individuals undergoing CTC after a positive FOBt in the English Bowel Cancer Screening Programme were analysed. The detection of colorectal cancer (CRC), advanced neoplasia, and ≥ 6 mm polyps were stratified by the number of positive FOBt windows. The PPV was calculated by reference to subsequent endoscopy results. The influence of the FOBt result on detection rates was estimated with multilevel logistic regression. PPV, CRC stage, and location were compared across groups according to FOBt positivity. RESULTS: Four thousand, six hundred and one individuals were included (mean = 66.7 years, 54.2% men). Detection rates of CRC and advanced neoplasia increased with greater numbers of positive FOBt windows (odds ratio [OR] for CRC = 1.41; 95% confidence interval [CI]: 1.31-1.52; OR for advanced neoplasia = 1.17; 95%CI: 1.12-1.23; both p < 0.0001). The PPV was significantly greater at higher FOBt levels (p = 0.020). The number of positive FOBt windows had no significant effect on stage (p = 0.30) or location (p = 0.20) of confirmed CRC. CONCLUSIONS: The magnitude of FOBt positivity influences the PPV and detection rates when screening for colorectal neoplasia. CTC may be particularly useful for FOBt patients with few positive test windows.


Assuntos
Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/sangue , Neoplasias Colorretais/diagnóstico por imagem , Sangue Oculto , Idoso , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Colorectal Dis ; 16(5): 347-52, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24119259

RESUMO

AIM: Abdominal computed tomography (CT) improves the accuracy of clinical diagnosis and facilitates patient management. Radiation exposure must be considered by requesting clinicians and is especially relevant owing to the increasing use of CT colonography for diagnosis and screening of colorectal disorders. This review describes the radiation dose of abdominopelvic CT and colonography and attempts to quantify the risk for the clinician. METHOD: Articles were searched in the PubMed and Medline databases using combinations of the MeSH terms 'radiation', 'abdominal computed tomography' and 'colonography'. Electronic English language abstracts were read by two reviewers and the full article was retrieved if relevant to the review. RESULTS: Abdominopelvic CT and CT colonography convey significant radiation dose to the patient but also have considerable diagnostic potential. In the right clinical context, the radiation risk should not be overestimated. Techniques to reduce the dose should be used. Repeated imaging in certain patients is a concern and should be monitored. CONCLUSION: Radiation risk can be quantified and presented simply in a manner that both patients and doctors can comprehend and evaluate. This approach will diminish misconceptions and allow a rational choice of diagnostic test.


Assuntos
Cirurgia Colorretal , Conhecimentos, Atitudes e Prática em Saúde , Doses de Radiação , Lesões por Radiação/etiologia , Tomografia Computadorizada por Raios X , Colonografia Tomográfica Computadorizada/efeitos adversos , Comunicação , Humanos , Pelve/diagnóstico por imagem , Radiografia Abdominal/efeitos adversos , Medição de Risco , Tomografia Computadorizada por Raios X/efeitos adversos
13.
Clin Radiol ; 69(6): 597-605, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24589446

RESUMO

AIM: To describe our experience using a 5 year audit of computed tomography colonography (CTC) practice and identify factors that influence diagnostic performance to guide implementation in other centres. MATERIAL AND METHODS: Consecutive patients referred for CTC at a single institution over a 5 year period were identified, and reporting rates and positive predictive value (PPV) calculated for small polyps, large polyps, and colorectal cancer. Diagnostic performance was compared using the Chi-squared test, and trends over time were examined with logistic regression. The effect of faecal tagging and an intravenous spasmolytic were investigated using Fisher's exact test. RESULTS: In total, 4355 CTC examinations were performed. Overall reporting rates and PPV were 17% and 92%, respectively. Negative predictive value (NPV) for cancer was 99.9%. A significant decrease in reporting rate (p < 0.001) was accompanied by an increase in PPV for small polyps (p = 0.02) following the introduction of faecal tagging. Adequacy rates for CTC improved over time (96% to 99%), with improved adequacy rates when using a spasmolytic, 98% versus 96% without. A significant difference in reporting rates, but not PPV, was found between radiologists. CONCLUSION: Accurate colonic investigation using CTC can be delivered safely to a high-risk patient population at a single centre. Faecal tagging and an intravenous spasmolytic improve diagnostic performance.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/estatística & dados numéricos , Neoplasias Colorretais/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Ambulatórios/estatística & dados numéricos , Agendamento de Consultas , Catárticos/administração & dosagem , Colonoscopia/estatística & dados numéricos , Meios de Contraste/administração & dosagem , Atenção à Saúde/estatística & dados numéricos , Fezes/química , Feminino , Humanos , Infusões Intravenosas , Masculino , Auditoria Médica , Pessoa de Meia-Idade , Variações Dependentes do Observador , Equipe de Assistência ao Paciente , Valor Preditivo dos Testes , Encaminhamento e Consulta/estatística & dados numéricos , Reino Unido , Adulto Jovem
14.
bioRxiv ; 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38712140

RESUMO

Neonatal herpes simplex virus (nHSV) is a devastating infection impacting approximately 14,000 newborns globally each year. Infection is associated with high neurologic morbidity and mortality, making early intervention and treatment critical. Clinical outcomes of symptomatic nHSV infections are well-studied, but little is known about the frequency of, or outcomes following, sub-clinical or asymptomatic nHSV. Given the ubiquitous nature of HSV infection and frequency of asymptomatic shedding in adults, subclinical infections are underreported, yet could contribute to long-term neurological damage. To assess potential neurological morbidity associated with subclinical nHSV infection, we developed a low-dose (100 PFU) HSV infection protocol in neonatal C57BL/6 mice. At this dose, HSV DNA was detected in the brain by PCR but was not associated with acute clinical symptoms. However, months after initial inoculation with 100 PFU of HSV, we observed impaired mouse performance on a range of cognitive and memory performance tasks. Memory impairment was induced by infection with either HSV-1 or HSV-2 wild-type viruses, but not by a viral mutant lacking the autophagy-modulating Beclin-binding domain of the neurovirulence gene γ34.5. Retroviral expression of wild type γ34.5 gene led to behavioral pathology in mice, suggesting that γ34.5 expression may be sufficient to cause cognitive impairment. Maternal immunization and HSV-specific antibody treatment prevented offspring from developing neurological sequelae following nHSV-1 infection. Altogether, these results support the idea that subclinical neonatal infections may lead to cognitive decline in adulthood, with possible profound implications for research on human neurodegenerative disorders such as Alzheimer's Disease.

15.
Optica ; 11(4): 569-576, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-39006164

RESUMO

With histopathology results typically taking several days, the ability to stage tumors during interventions could provide a step change in various cancer interventions. X-ray technology has advanced significantly in recent years with the introduction of phase-based imaging methods. These have been adapted for use in standard labs rather than specialized facilities such as synchrotrons, and approaches that enable fast 3D scans with conventional x-ray sources have been developed. This opens the possibility to produce 3D images with enhanced soft tissue contrast at a level of detail comparable to histopathology, in times sufficiently short to be compatible with use during surgical interventions. In this paper we discuss the application of one such approach to human esophagi obtained from esophagectomy interventions. We demonstrate that the image quality is sufficiently high to enable tumor T staging based on the x-ray datasets alone. Alongside detection of involved margins with potentially life-saving implications, staging tumors intra-operatively has the potential to change patient pathways, facilitating optimization of therapeutic interventions during the procedure itself. Besides a prospective intra-operative use, the availability of high-quality 3D images of entire esophageal tumors can support histopathological characterization, from enabling "right slice first time" approaches to understanding the histopathology in the full 3D context of the surrounding tumor environment.

16.
Colorectal Dis ; 15(6): 655-61, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23581820

RESUMO

Diffusion weighted imaging (DWI) is an MRI technique that quantifies the movement of water molecules at a cellular level. As the diffusion properties of water vary in areas of necrosis, high cellularity, inflammation and fibrosis, this technique is inherently sensitive to different pathologies. Having become a well-established adjunct to standard sequences during neurological MRI, technological advances have enabled extrapolation to abdominopelvic imaging, including staging of rectal cancer. Scan acquisitions can be performed rapidly using widely available equipment and consequently there has been rapid dissemination into routine practice. However, while DWI shows promise for detecting, staging and monitoring rectal cancer response to therapy, the evidence base remains scant with no current consensus for technical protocols, interpretation or integration into rectal cancer management. Moreover, those studies available to date have a small sample size and few observers, and their results may not be generalizable to daily practice. This article outlines the physical principles of DWI, reviews the literature and suggests avenues for future research into this important technical development.


Assuntos
Adenocarcinoma/diagnóstico , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Retais/diagnóstico , Adenocarcinoma/terapia , Humanos , Neoplasias Retais/terapia
17.
Clin Radiol ; 68(5): 479-87, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23245277

RESUMO

AIM: To obtain information regarding the provision of computed tomography colonography (CTC) services to the National Health Service (NHS) Bowel Cancer Screening Programme (BCSP). MATERIALS AND METHODS: Specialist screening practitioners at the 58 BCSP screening centres and lead BCSP radiologists at 110 hospitals performing CTC for the Programme were contacted and completed a semi-structured questionnaire administered by telephone. Responses were collated and descriptive statistics derived. RESULTS: One hundred and seven (98%) SSPs and 103 (94%) radiologists were surveyed. All screening centres had access to CTC at 110 hospital sites. All sites used CTC for failed or contraindicated colonoscopy, 24% used it for patients taking anticoagulants, and 17% for those with fear of colonoscopy. Patient preference was not an indication at any site. Multidetector CT (100%), carbon dioxide insufflators (94%), and CTC software (95%) were almost universal. Ninety-one percent of radiographers and 98% of radiologists were trained in CTC image acquisition and interpretation, respectively. Seventy-five percent of the radiologists were gastrointestinal subspecialists and two-thirds had interpreted more than 300 examinations in clinical practice, although 5% had interpreted fewer than 100. Eighty-one percent of radiologists favoured some form of accreditation for CTC interpretation. CONCLUSIONS: CTC is widely available to the BCSP. Appropriate hardware and software is almost ubiquitous. Most radiographers and radiologists offering CTC to the BCSP have received specific training. Formal service evaluation is patchy. The majority of radiologists would welcome national accreditation for CTC.


Assuntos
Competência Clínica/estatística & dados numéricos , Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Pesquisas sobre Atenção à Saúde/métodos , Padrões de Prática Médica/estatística & dados numéricos , Acreditação , Colonografia Tomográfica Computadorizada/estatística & dados numéricos , Detecção Precoce de Câncer/estatística & dados numéricos , Pesquisas sobre Atenção à Saúde/estatística & dados numéricos , Humanos , Entrevistas como Assunto/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Inquéritos e Questionários , Reino Unido
18.
Clin Radiol ; 68(11): 1140-5, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23948662

RESUMO

AIMS: To explore the relative value patients place on comfort and convenience versus test sensitivity and specificity in the context of computed tomographic colonography (CTC) screening. MATERIALS AND METHODS: Twenty semi-structured interviews were carried out with patients attending hospital for radiological tests unrelated to CTC. Preferences for CTC with different types of bowel preparation for CTC screening were examined and interviews were analysed thematically. The discussion guide included separate sections on CTC, bowel preparation methods (non-, reduced- and full-laxative), and sensitivity and specificity. Patients were given information on each topic in turn and asked about their views and preferences during each section. RESULTS: Following information about the test, patients' attitudes towards CTC were positive. Following information on bowel preparation, full-laxative purgation was anticipated to cause more adverse physical and lifestyle effects than using reduced- or non-laxative preparation. However, stated preferences were approximately equally divided, largely due to patients anticipating that non-laxative preparations would reduce test accuracy (because the bowel was not thoroughly cleansed). Following information on sensitivity and specificity (which supported patients' expectations), the predominant stated preference was for full-laxative preparation. CONCLUSIONS: Patients are likely to value test sensitivity and specificity over a more comfortable and convenient preparation. Future research should test this hypothesis on a larger sample.


Assuntos
Catárticos , Colonografia Tomográfica Computadorizada/métodos , Colonografia Tomográfica Computadorizada/psicologia , Neoplasias Colorretais/diagnóstico , Laxantes , Preferência do Paciente/estatística & dados numéricos , Atitude Frente a Saúde , Feminino , Humanos , Entrevistas como Assunto , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
19.
Clin Radiol ; 68(5): 472-8, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23265916

RESUMO

AIM: To compare patients' experiences of either non- or full-laxative bowel preparation with additional faecal tagging and subsequent computed tomographic (CT) colonography using in-depth interviews to elicit detailed responses. MATERIALS AND METHODS: Patients who received CT colonography after non- (n = 9) or full-laxative (n = 9) preparation participated in a semi-structured telephone interview at least 2 days after the investigation. Full-laxative preparation consisted of magnesium citrate and sodium picosulphate administered at home (or polyethylene glycol, if contraindicated), followed by hospital-based faecal tagging with iohexol. Non-laxative preparation was home-based barium sulphate for faecal tagging. Interviews were transcribed and thematically analysed to identify recurrent themes on patients' perceptions and experiences. RESULTS: Experiences of full-laxative preparation were usually negative and characterized by pre-test diarrhoea that caused significant interference with daily routine. Post-test flatus was common. Non-laxative preparation was well-tolerated; patients reported no or minimal changes to bowel habit and rapid return to daily routine. Patients reported worry and uncertainty about the purpose of faecal tagging. For iohexol, this also added burden from waiting before testing. CONCLUSION: Patients' responses supported previous findings that non-laxative preparation is more acceptable than full-laxative preparation but both can be improved. Faecal tagging used in combination with laxative preparation is poorly understood, adding burden and worry. Home-based non-laxative preparation is also poorly understood and patients require better information on the purpose and mechanism in order to give fully informed consent. This may also optimize adherence to instructions. Allowing home-based self-administration of all types of preparation would prevent waiting before testing.


Assuntos
Colonografia Tomográfica Computadorizada/métodos , Meios de Contraste , Fezes , Entrevistas como Assunto/métodos , Laxantes/administração & dosagem , Satisfação do Paciente/estatística & dados numéricos , Idoso , Atitude Frente a Saúde , Sulfato de Bário , Catárticos/administração & dosagem , Citratos/administração & dosagem , Ácido Cítrico/administração & dosagem , Neoplasias Colorretais/diagnóstico por imagem , Feminino , Humanos , Iohexol , Masculino , Compostos Organometálicos/administração & dosagem , Picolinas/administração & dosagem , Polietilenoglicóis/administração & dosagem , Intensificação de Imagem Radiográfica/métodos
20.
Nat Genet ; 2(3): 223-7, 1992 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-1345173

RESUMO

We have applied the technique of exon amplification to the isolation of genes from the chromosome 4p16.3 Huntington's disease (HD) candidate region. Exons recovered from cosmid Y24 identified cDNA clones corresponding to the alpha-subunit of adducin, a calmodulin-binding protein that is thought to promote assembly of spectrin-actin complexes in the formation of the membrane cytoskeleton, alpha-adducin is widely expressed and, at least in brain, is encoded by alternatively spliced mRNAs. The alpha-adducin gene maps immediately telomeric to D4S95, in a region likely to contain the HD defect, and must be scrutinized to establish whether it is the site of the HD mutation.


Assuntos
Proteínas Sanguíneas/genética , Proteínas de Ligação a Calmodulina/genética , Cromossomos Humanos Par 4 , Éxons/genética , Doença de Huntington/genética , Processamento Alternativo/genética , Sequência de Aminoácidos , Animais , Sequência de Bases , Química Encefálica/genética , Proteínas de Ligação a Calmodulina/análise , Proteínas de Ligação a Calmodulina/química , Clonagem Molecular , Humanos , Dados de Sequência Molecular , Técnicas de Amplificação de Ácido Nucleico , Papio , RNA Mensageiro/análise , Mapeamento por Restrição , Análise de Sequência de DNA , Transcrição Gênica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA