Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Heart Vessels ; 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38822844

RESUMO

The relationship between subclinical atrial fibrillation (SCAF) and left pulmonary vein anatomy is unknown. This study sought to investigate whether left pulmonary vein trunk predict the development of SCAF in patients with cardiac implantable electronic device (CIED). We also examined the relationship between the duration of SCAF and left pulmonary vein trunk. We retrospectively enrolled 162 patients who underwent implantation of dual-chamber CIEDs and follow-up by remote monitoring system. Computed tomography was used to measure the length of the left pulmonary vein. During median follow up of 2.7 years, the episodes of > 6 min and > 24 h SCAF were observed in 61 (37.7%) and 24 (14.8%) patients, respectively. The diagnosis of sinus node disease (HR: 3.66 [2.06-6.52], P < 0.01 and HR: 2.68 [1.09-6.62], P = 0.04) and left atrial diameter (HR: 1.04 [1.00-1.07], P = 0.04 and HR: 1.05 [1.00-1.10], P = 0.04) were independent predictors for > 6 min and > 24 h SCAF, respectively. Length of the left pulmonary vein trunk was an independent predictor for > 6 min SCAF (HR: 1.06 [1.02-1.10], P < 0.01), but not for > 24 h SCAF (P = 0.06). Sinus node disease, size of the left atrium and length of the left pulmonary vein trunk were related to SCAF. The left pulmonary vein trunk might especially contribute as a trigger rather than as a driver of development of atrial fibrillation.

2.
Artigo em Inglês | MEDLINE | ID: mdl-37988233

RESUMO

Debranching thoracic endovascular aortic repair may disturb the implantation of a cardiac implantable electronic device in the anterior thoracic region. In case 1, the bypass graft between the right axillary artery, left axillary artery, and left common carotid artery disturbed pacemaker implantation from the left anterior thoracic region. Therefore, right-sided implantation was selected. By contrast, in case 2, the bypass graft between axillary arteries in the anterior thoracic region was visible on fluoroscopy, and we performed conventional left-sided pacemaker implantation with extra-thoracic puncture. The pacemaker implantations were successful in both cases. The implantation strategies were affected by the number of debranched arteries and visibility of the bypass graft.

4.
Circ J ; 86(9): 1388-1396, 2022 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-35545551

RESUMO

BACKGROUND: Patients with acute myocardial infarction (AMI) caused by calcified nodules (CN) have worse clinical outcomes following primary percutaneous coronary intervention (PCI). This study investigated the late vascular response after everolimus-eluting stent (EES) implantation assessed by optical coherence tomography (OCT) in patients with AMI caused by CN, by comparing with plaque rupture (PR) and plaque erosion (PE).Methods and Results: Based on the OCT findings in AMI culprit lesions before PCI, a total of 141 patients were categorized into 3 groups (PR, PE, or CN), and the OCT findings immediately and 10 months after PCI were compared. The frequency of PR, PE, and CN was 85 (60%), 45 (32%), and 11 patients (8%), respectively. In the 10-month follow-up OCT, the frequency of lesions with uncovered struts and lesions with malapposed struts were highest in the CN group, followed by the PR and PE groups (82% vs. 52% vs. 40%, P=0.042 and 73% vs. 26% vs. 16%, P<0.001, respectively). The incidence of intra-stent thrombus, re-appearance of CN within the stent, and target lesion revascularization were higher in the CN group compared with the PR and PE groups (36% vs. 9% vs. 7%, P=0.028; 27% vs. 0% vs. 0%, P<0.001; and 18% vs. 2% vs. 2%, P=0.024, respectively). CONCLUSIONS: Late arterial healing response at 10 months after EES implantation in the CN was worse compared with PR and PE in patients with AMI.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Placa Aterosclerótica , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Stents Farmacológicos/efeitos adversos , Everolimo , Humanos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Placa Aterosclerótica/patologia , Stents , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
5.
Heart Vessels ; 37(1): 91-98, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34089364

RESUMO

Central venous access is an essential technique for cardiovascular implantable electronic device (CIED) implantation, and the use of axillary vein approach has recently been increasing. This study sought to examine whether real-time venography-guided extrathoracic puncture facilitates the procedure. We retrospectively analyzed 179 consecutive patients who underwent CIED implantation using the axillary vein puncture method. Patients were divided into two groups: the conventional method group (CG, n = 107) and the real-time venography-guided group (RG, n = 82). The application of real-time venography was at the discretion of individual operators. Operators with experience of less than 50 CIED implantations were defined as inexperienced operators in this study. Puncture duration and number of attempts were significantly less in the RG group than in the CG group (283 ± 198 vs. 421 ± 361 s, p < 0.01, and 3.19 ± 2.00 vs. 4.18 ± 2.85, p < 0.01). These benefits of real-time venography were observed in inexperienced operators, but not in experienced operators. In addition, the success rate without extra attempts at puncture was higher in the RG group (54% vs. 32%, p < 0.01). Although the total amount of contrast medium was higher in the RG group (16.3 ± 4.1 mL vs. 11.9 ± 6.6 mL, p < 0.01), serum levels of creatinine pre- and post-operation were not different in the two groups (p = NS). We concluded that real-time venography is a safe and effective method for axillary vein puncture, especially in inexperienced operators.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Punções , Eletrônica , Humanos , Flebografia , Implantação de Prótese , Estudos Retrospectivos
6.
Heart Vessels ; 37(2): 200-207, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34287687

RESUMO

Optical coherence tomography (OCT)-angiography coregistration during stent implantation may be useful to avoid geographical mismatch and incomplete lesion coverage. Untreated lipid-rich plaque at stent edge is associated with subsequent stent edge restenosis. The present study sought to compare the frequency of untreated lipid-rich plaque at the stent edge between OCT-guided percutaneous coronary intervention (PCI) with and without OCT-angiography coregistration. We investigated 398 patients who underwent OCT-guided stent implantation (n = 198 in the coregistration group, and n = 200 in the no coregistration group). In OCT after PCI, untreated lipid-lich plaque was identified by the maximum lipid arc > 180˚ in the 5-mm stent edge segment. The PCI-targeted lesion characteristics and stent length were not different between the coregistration group and the no coregistration group. The frequency of untreated lipid-rich plaque in either proximal or distal stent edge segment was significantly lower in the coregistration group than in the no coregistration group (16% vs. 26%, P = 0.015). The frequency of stent-edge dissection (5% vs. 6%, P = 0.516) and untreated stenosis (2% vs. 3%, P = 0.724) was low and without significant differences between the two groups. In OCT-guided PCI, the use of OCT-angiography coregistration was associated with a reduced frequency of untreated lipid-rich plaque at stent edges. OCT-angiography coregistration has a positive impact on PCI results.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Humanos , Intervenção Coronária Percutânea/métodos , Stents , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
7.
Circ J ; 85(10): 1781-1788, 2021 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-33473095

RESUMO

BACKGROUND: Optical coherence tomography (OCT) provides valuable information to guide percutaneous coronary intervention (PCI) in acute coronary syndrome (ACS) regarding lesion preparation, stent sizing, and optimization. The aim of the present study was to compare lumen expansion of stent-treated lesions immediately after the procedure for ACS between OCT-guided PCI and angiography-guided PCI.Methods and Results:This study investigated stent-treated lesions immediately after PCI for ACS by using quantitative coronary angiography in 390 patients; 260 patients with OCT-guided PCI and 130 patients with angiography-guided PCI. Before stenting, the frequency of pre-dilatation and thrombus aspiration were not different between the OCT-guided and angiography-guided PCI groups. Stent diameter was significantly larger as a result of OCT-guided PCI (3.11±0.44 mm vs. 2.99±0.45 mm, P=0.011). In post-dilatation, balloon pressure-up (48% vs. 31%, P=0.001) and balloon diameter-up (33% vs. 6%, P<0.001) were more frequently performed in the OCT-guided PCI group. Minimum lumen diameter (2.55±0.35 mm vs. 2.13±0.50 mm, P<0.001) and acute lumen gain (2.18±0.54 mm vs. 1.72±0.63 mm, P<0.001) were significantly larger in the OCT-guided PCI group. Percent diameter stenosis (14±4% vs. 24±10%, P<0.001) and percent area stenosis (15±5% vs. 35±17%, P<0.001) were significantly smaller in the OCT-guided PCI group. CONCLUSIONS: OCT-guided PCI potentially results in larger lumen expansion of stent-treated lesions immediately after PCI in the treatment of ACS compared with angiography-guided PCI.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/cirurgia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Humanos , Intervenção Coronária Percutânea/métodos , Stents , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
8.
Circ J ; 84(6): 911-916, 2020 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-32307358

RESUMO

BACKGROUND: Acute myocardial infarction (AMI) is caused by coronary plaque rupture (PR), plaque erosion (PE), or calcified nodule (CN). We used optical coherence tomography (OCT) to compare stent expansion immediately after primary percutaneous coronary intervention (PCI) in patients with AMI caused by PR, PE, or CN.Methods and Results:In all, 288 AMI patients were assessed by OCT before and immediately after PCI, performed with OCT guidance according to OPINION criteria for stent sizing and optimization. The frequency of OCT-identified PR (OCT-PR), OCT-PE, and OCT-CN was 172 (60%), 82 (28%), and 34 (12%), respectively. Minimum stent area was smallest in the OCT-CN group, followed by the OCT-PE and OCT-PR groups (mean [±SD] 5.20±1.77, 5.44±1.78, and 6.44±2.2 mm2, respectively; P<0.001), as was the stent expansion index (76±13%, 86±14%, and 87±16%, respectively; P=0.001). The frequency of stent malapposition was highest in the OCT-CN group, followed by the OCT-PR and OCT-PE groups (71%, 38%, and 27%, respectively; P<0.001), as was the frequency of stent edge dissection in the proximal reference (44%, 23%, and 10%, respectively; P<0.001). The frequency of tissue protrusion was highest in the OCT-PR group, followed by the OCT-PE and OCT-CN groups (95%, 88%, and 85%, respectively; P=0.036). CONCLUSIONS: Stent expansion was smallest in the OCT-CN group, followed by the OCT-PR and OCT-PE groups. Plaque morphology in AMI culprit lesions may affect stent expansion immediately after primary PCI.


Assuntos
Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/instrumentação , Placa Aterosclerótica , Tomografia de Coerência Óptica , Calcificação Vascular/terapia , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Retrospectivos , Ruptura Espontânea , Stents , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem
9.
Circ J ; 84(12): 2253-2258, 2020 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-33115983

RESUMO

BACKGROUND: Optical flow ratio (OFR) is a recently developed method for functional assessment of coronary artery disease based on computational fluid dynamics of vascular anatomical data from intravascular optical coherence tomography (OCT). The purpose of this study was to investigate the relationship between OFR and fractional flow reserve (FFR) in stent-treated arteries immediately after percutaneous coronary intervention (PCI).Methods and Results:The OFR and FFR were measured in 103 coronary arteries immediately after successful PCI with a stent. An increase in the OFR and FFR values within the stent was defined as in-stent ∆OFR and ∆FFR, respectively. The values of FFR and OFR were 0.89±0.06 and 0.90±0.06, respectively. OFR was highly correlated with FFR (r=0.84, P<0.001). OFR showed a good agreement with FFR, presenting small values of mean difference and root-mean-squared deviation (FFR-OFR: -0.01±0.04). In-stent ∆OFR showed a moderate correlation (r=0.69, P<0.001) and good agreement (in-stent ∆FFR - in-stent ∆OFR: 0.00±0.02) with in-stent ∆FFR. CONCLUSIONS: OFR showed a high correlation and good agreement with FFR in stent-treated arteries immediately after PCI.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Fluxo Óptico , Intervenção Coronária Percutânea , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Stents , Tomografia de Coerência Óptica , Resultado do Tratamento
10.
Int Heart J ; 60(6): 1238-1244, 2019 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-31735779

RESUMO

Recent clinical studies revealed that anatomical information assessed by coronary computed tomography angiography (CTA) may be used effectively to diagnose coronary artery disease (CAD). However, a physiological assessment, demonstrating myocardial ischemia, is required to justify a therapeutic strategy for CAD. This study aimed to investigate whether using CTA to assess myocardial supply area can improve the prediction of myocardial ischemia.We analyzed 201 vessels with moderate (luminal narrowing ≥ 50%, < 70%) and severe (luminal narrowing ≥ 70%, < 99%) stenosis on CTA from 174 patients, who were suspected of having stable angina and underwent measurement of fractional flow reserve (FFR). The myocardial area supplied by the coronary artery, distal to the stenosis, was evaluated with CTA, as reported previously (modified Alberta Provincial Project for Outcome Assessment in Coronary Heart score) and was classified into 3 groups (large, medium, and small).Both percentage area stenosis and myocardial supply area were significantly correlated with FFR (r = -0.46, P < 0.01, and r = -0.45, P < 0.01). Among patients who had coronary plaques, with moderate stenosis and a small myocardial supply area, only 3 of 42 lesions (7%) were identified as ischemic; deviation from the ischemic threshold (FFR = 0.80) was P < 0.01. The combined assessment of lesion stenosis and myocardial supply area, using CTA, improved the prediction of myocardial ischemia significantly compared to lesion stenosis alone (77% versus 59%, P < 0.01).Adding the assessment of myocardial supply area to standard CTA might help predict myocardial ischemia in patients with stable angina pectoris.


Assuntos
Angiografia por Tomografia Computadorizada , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Idoso , Circulação Coronária/fisiologia , Estenose Coronária/complicações , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/etiologia , Valor Preditivo dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA