Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(1): 186-193, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38140761

RESUMO

BACKGROUND: Patients undergoing transcatheter aortic valve implantation (TAVI) frequently have coronary artery disease requiring percutaneous coronary intervention (PCI). Usually, PCI and TAVI are performed in two separate procedures and current studies are investigating potential benefits regarding the order. However, the two interventions may also be performed simultaneously, thereby limiting the risk associated with repeated vascular access. Data evaluating benefit and harm of concomitant procedures are scarce. AIMS: Therefore, this study aimed to evaluate concomitant PCI (coPCI) in TAVI patients regarding Valve Academic Research Consortium 3 (VARC-3) endpoints and long-term mortality. METHODS: A total of 2233 consecutive TAVI patients from the EVERY-VALVE registry were analyzed according to the VARC-3 endpoint definitions. A total of 274 patients had undergone TAVI and concomitant PCI (coPCI group). They were compared to 226 TAVI patients who had received PCI within 60 days before TAVI in a stepwise approach (swPCI group) and to the remaining 1733 TAVI patients who had not undergone PCI recently (noPCI group). RESULTS: Overall median age was 81.4 years, median Society of Thoracic Surgeons score was 4.0%. Patients in the coPCI and in the swPCI group were predominantly male with reduced left-ventricular ejection fraction. Rates of VARC-3 composite endpoints technical success and 30-day device success were comparable between all three groups. Mortality rates at 3 years after TAVI were similar (coPCI, 34.2% vs. swPCI, 31.9% vs. noPCI, 34.0% p = 0.84). CONCLUSIONS: coPCI during TAVI seems comparable in a retrospective analysis. Compared to a stepwise approach, it has similar rates of composite endpoints technical success and device success as well as long-term mortality.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Estudos Retrospectivos , Volume Sistólico , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Função Ventricular Esquerda , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
2.
Catheter Cardiovasc Interv ; 93(1): 71-78, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30232838

RESUMO

AIM AND OBJECTIVE: We sought to investigate and compare outcomes 2 years after Hybrid-stenting with bioresorbable vascular scaffolds (BVS) and contemporary metallic drug-eluting stents (DES) within the same coronary lesion versus BVS alone. METHODS: Between 11/2012 and 7/2015 at our institution, 134 (33.2%) were treated with Hybrid-stenting for complex or long coronary lesions, 270 patients were treated by BVS alone. The primary outcome of interest was target lesion failure (TLF) at 2-years of follow-up. RESULTS: Patients treated by Hybrid-stenting were more frequently men (80% vs. 70%, p = 0.04) had extensive multivessel disease (84% vs. 71%, p < 0.01) including more complex (89% vs. 52%, p < 0.01) and longer lesions (28.9 mm vs 16.4 ± mm, p < 0.01) resulting in longer treated segments (47.3 mm vs 21.5 mm, p < 0.01) and more residual in-segment stenosis (12.3% vs 8.5%, p < 0.01) compared to BVS alone patients. At 2 years, cumulative incidence of TLF was 9.7% of Hybrid-stenting patients and 11.5% of BVS alone patients (p = 0.62), myocardial infarction (3.0% vs 4.1%, p = 0.59) and mortality (1.5% vs 4.1%, p = 0.17), respectively. Target lesion revascularization occurred in 9 Hybrid-stenting patients (2 located in DES) and in 20 BVS alone patients, cumulative incidence 6.7% vs. 7.4% (p = 0.80). Chronic kidney disease and residual in-segment stenosis >30% were identified as independent predictors of TLF at 2-years. CONCLUSION: Despite differences in clinical and angiographic profile, Hybrid-stenting performed similar to BVS alone at 2 years after percutaneous coronary intervention.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Stents Farmacológicos , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 89(4): E162-E168, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27038099

RESUMO

OBJECTIVES: To identify potential predictors for ventricular conduction delay and to evaluate the impact of interventricular dyssynchrony on mortality after implantation of a balloon-expandable aortic valve (BEV). METHODS AND RESULTS: Clinical, computertomographical (CT), and electrocardiographical (ECG) data from 225 transcatheter aortic valve implantation (TAVI) patients were analyzed. Procedures were performed between May 2010 and September 2013 via transfemoral access using a BEV. Incidence of new-onset left bundle branch block (NOP-LBBB) at discharge was 23.1% (n = 52). Predictive factors for NOP-LBBB were first degree atrioventricular (AV) block (odds ratio (OR): 3.91, 95% confidence interval (CI): 1.58 to 9.64), area cover index (OR: 1.83, 95% CI: 1.26 to 2.67), annulus calcification > first degree (OR: 3.01, 95% CI: 1.36 to 6.66), and annulus to left coronary distance (OR: 0.65, 95% CI: 0.44 to 0.96). At 1-year follow-up, no significant difference was observed concerning all-cause mortality (15.6% among non NOP-LBBB and 9.6% among NOP-LBBB patients, P = 0.278) and cardiovascular mortality (4.6% among non NOP-LBBB and 5.8% among NOP-LBBB patients, P = 0.737). CONCLUSION: In addition to previous predictors, annulus to left coronary distance and area cover index have been identified as new predictors for NOP-LBBB. NOP-LBBB showed no relevant impact on mortality after one year. Further investigation including larger populations and longer follow-up is required to confirm these findings and develop an algorithm for identification of patients at risk for NOP-LBBB associated adverse events. © 2016 Wiley Periodicals, Inc.


Assuntos
Aorta Torácica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/etiologia , Vasos Coronários/diagnóstico por imagem , Próteses Valvulares Cardíacas/efeitos adversos , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Bloqueio de Ramo/diagnóstico , Cateterismo Cardíaco , Eletrocardiografia , Feminino , Humanos , Incidência , Masculino , Razão de Chances , Complicações Pós-Operatórias , Prognóstico , Fatores de Risco , Tomografia Computadorizada por Raios X
4.
J Interv Cardiol ; 30(1): 16-23, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27896843

RESUMO

BACKGROUND: Optimal strut coverage and early vascular healing are important factors to reduce the risk of stent thrombosis. Data on early vascular healing with the new bioresorbable vascular scaffolds (BVS) are lacking. Further, healing response after BVS implantation in different clinical presentation has not been fully investigated. METHODS AND RESULTS: We assessed with optical coherence tomography (OCT) the early vascular response to BVS implantation in 26 consecutive patients presenting with acute coronary syndrome (ACS) or stable angina (SA). Images from 16 BVSs (17,166 struts) in ACS patients and 17 BVSs (23,045 struts) in SA patients were analyzed. The mean implanted BVS diameter and length was 3.1 ± 0.4 mm and 20.4 ± 5.8 mm. At mean 47.6 ± 6.3 days, overall 99% of BVS struts were covered. There were no differences between ACS and SA on the amount of tissue coverage per strut (0.09 ± 0.02 mm vs. 0.09 ± 0.01 mm; P = 0.86, respectively) and lumen area stenosis (24.2 ± 19.3% vs. 22.3 ± 22.0%; P = 0.78, respectively). However, a numerically higher proportion of protruding (ACS 1.2 ± 2.7%; SA 4.2 ± 6.5%; P = 0.11) and malapposed (ACS 0.4 ± 0.5%; SA 2.4 ± 5.8%; P = 0.18) struts were observed in SA compared to ACS, with trendy better healing score in ACS (1.87 ± 1.67 vs. 5.28 ± 7.28, P = 0.08). CONCLUSION: Early after BVS implantation almost complete scaffold strut coverage without any thrombi was observed by OCT, independent by the clinical presentation at index coronary intervention. However, BVS in ACS lesions were associated with easier strut penetration and a trendy better healing score compared with SA.


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/diagnóstico por imagem , Angina Estável/diagnóstico por imagem , Implante de Prótese Vascular , Prótese Vascular , Cicatrização , Síndrome Coronariana Aguda/terapia , Idoso , Angina Estável/terapia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento
5.
Platelets ; 27(5): 446-51, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26940818

RESUMO

While promising data with the novel bioresorbable vascular scaffold (BVS) are accumulating, signals of scaffold thrombosis (ST) were noted in recent reports. We aimed to assess the relationship between the total surface area (TSA) of implanted everolimus-eluting BVSs and the on-treatment adenosine diphosphate (ADP)-induced platelet reactivity in patients undergoing percutaneous coronary intervention (PCI). 202 consecutive patients undergoing BVS implantation and platelet function testing were included. For investigating the impact of the scaffold surface on platelet reactivity, patients were stratified into two groups regarding the median BVS TSA. The on-treatment ADP-induced platelet reactivity was determined with the Multiplate analyzer and 30-day follow-up was available in 98% of patients. ADP-induced platelet aggregation values (median, [IQR]) did not differ between the two study groups (12.0 [9.0-19.0] U for patients with TSA > 1.39 cm(2) and 13.0 [9.0-19.5] U for patients with TSA ≤ 1.39 cm(2); p = 0.69). No correlation was observed between the BVS TSA and levels of platelet reactivity (Spearman rank correlation = -0.10, p = 0.16). At 30 days after PCI, two early STs (1%) were documented. Thus, in patients on a dual antiplatelet treatment regimen following BVS implantation, the extent of blood-to-BVS contact surface does not negatively affect levels of on-treatment platelet reactivity.


Assuntos
Implantes Absorvíveis , Plaquetas/metabolismo , Ativação Plaquetária , Alicerces Teciduais , Idoso , Plaquetas/efeitos dos fármacos , Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Ativação Plaquetária/efeitos dos fármacos , Inibidores da Agregação Plaquetária/farmacologia , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Retrospectivos , Trombose/sangue , Trombose/etiologia , Trombose/terapia , Resultado do Tratamento
6.
Artif Organs ; 38(3): 231-4, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24147881

RESUMO

In this retrospective study, we investigated the impact of preconditioning of the right ventricle with the calcium sensitizer levosimendan immediately before left ventricular assist device (LVAD) implantation on outcome and survival. Nine consecutive LVAD patients (seven suffering from dilative cardiomyopathy and two from ischemic cardiomyopathy) with echocardiographic and invasive evidence of right heart insufficiency received levosimendan with 0.1 µg/kg body weight/min for 24 h before implantation of the assist device (seven HeartWare and two Jarvik 2000). Administration of levosimendan was safe and had not to be discontinued in any patient. We observed no relevant side effects. Twelve-month survival after implantation of the LVAD was 89% representing a superior outcome compared with the fifth INTERMACS registry data with 75% survival. Two temporary extracorporeal membrane-oxygenation implantations were necessary due to intraoperative right ventricular dysfunction. Only one patient died 5 weeks after LVAD implantation of multiorgan failure, five patients were successfully transplanted, and three patients underwent LVAD implantation for destination therapy. Levosimendan might improve clinical outcome and survival when used as pretreatment in patients with right heart insufficiency prior to LVAD implantation. However, we recommend a larger controlled trial in the future to confirm our preliminary results.


Assuntos
Cardiomiopatias/cirurgia , Cardiotônicos/uso terapêutico , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Hidrazonas/uso terapêutico , Piridazinas/uso terapêutico , Idoso , Cardiomiopatias/tratamento farmacológico , Feminino , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Simendana , Resultado do Tratamento
7.
Eur J Cardiothorac Surg ; 66(1)2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39037934

RESUMO

OBJECTIVES: Aortic valved allografts (homografts) have been used alternatively to mechanical or biological valve prostheses in expectation of better durability; however, homograft valves do degenerate, and redo procedures have proven challenging due to heavy wall calcification. The aim of the study was to compare the outcome of open surgical (SAVR) and transcatheter aortic valve replacement (TAVR) in degenerated homografts. METHODS: Between 1993 and 2022, 81 patients underwent repeat aortic valve procedures having previously received an aortic homograft. The redo had become necessary due to regurgitation in 85% and stenosis in 15%. Sixty-five percent underwent open surgery, 35% TAVR. RESULTS: Isolated SAVR was possible in 79%, and root procedures were necessary in 21%. TAVR was performed in 79% via transfemoral and 21% via transapical access. Median prosthetic valve size was 23 (22.3-23.2) mm in the SAVR and 26 (25.2-26.9) in the TAVR group. Thirty-day mortality was 0% in the TAVR and 7% in the SAVR group (P = n.s.). TAVR showed a significantly better outcome concerning prolonged ventilation (0 vs 21%, P = 0.013) as well as ICU (1 vs 2 days; P < 0.001) and in-hospital stay (10.5 vs 13 days; P = 0.028). Five-year survival was statistically comparable between groups, and no severe leakage was observed. CONCLUSIONS: SAVR following structural homograft degeneration shows acceptable results, but the perioperative risk remains substantial and poorly predictable. TAVR presents a reasonable and more easily accessible alternative and is associated with good short- and mid-term results. In the absence of relevant contraindications, TAVR is presently the preferred treatment option for these patients at our center.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Reoperação , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Valva Aórtica/cirurgia , Idoso , Substituição da Valva Aórtica Transcateter/métodos , Reoperação/estatística & dados numéricos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Aloenxertos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Falha de Prótese , Resultado do Tratamento , Estudos Retrospectivos , Bioprótese , Pessoa de Meia-Idade
8.
JACC Cardiovasc Interv ; 17(8): 1020-1028, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38658116

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective and safe therapy for severe aortic stenosis. Rapid or fast pacing is required for implantation, which can be performed via a pre-existing cardiac implantable electric device (CIED). However, safety data on CIEDs for pacing in TAVR are missing. OBJECTIVES: The aim of this study was to elucidate procedural safety and feasibility of internal pacing with a CIED in TAVR. METHODS: Patients undergoing TAVR with a CIED were included in this analysis. Baseline characteristics, procedural details, and complications according to Valve Academic Research Consortium 3 (VARC-3) criteria after TAVR were compared between both groups. RESULTS: A total of 486 patients were included. Pacing was performed using a CIED in 150 patients and a transient pacemaker in 336 patients. No differences in technical success according to VARC-3 criteria or procedure duration occurred between the groups. The usage of transient pacers for pacing was associated with a significantly higher bleeding rate (bleeding type ≥2 according to VARC-3-criteria; 2.0% vs 13.1%; P < 0.01). Furthermore, impairment of the CIED appeared in 2.3% of patients after TAVR only in the group in which pacing was performed by a transient pacer, leading to surgical revision of the CIED in 1.3% of all patients when transient pacemakers were used. CONCLUSIONS: Internal pacing using a CIED is safe and feasible without differences of procedural time and technical success and might reduce bleeding rates. Furthermore, pacing using a CIED circumvents the risk of lead dislocation. Our data provide an urgent call for the use of a CIED for pacing during a TAVR procedure in general.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Estudos de Viabilidade , Hospitais com Alto Volume de Atendimentos , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Resultado do Tratamento , Fatores de Tempo , Idoso , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Índice de Gravidade de Doença , Medição de Risco
9.
JACC Cardiovasc Interv ; 17(1): 76-87, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38199755

RESUMO

BACKGROUND: Knowledge about atrial functional tricuspid regurgitation (afTR) in transcatheter aortic valve replacement (TAVR) patients is scarce. OBJECTIVES: The aim of the study was to analyze the association between the entity and the development of tricuspid regurgitation (TR) in patients undergoing TAVR for aortic stenosis and concomitant TR. METHODS: We analyzed patients undergoing TAVR for severe aortic stenosis from January 2013 to December 2020 and concomitant at least moderate TR at baseline. afTR was defined as enlargement of the right atrium in relation to the right ventricle. TR development after TAVR and 3-year all-cause mortality were evaluated. RESULTS: Out of 3,474 TAVR patients, we identified 420 patients with concomitant at least moderate TR. A total of 363 patients were included in the study, with 178 patients stratified in the afTR and 185 in the non-afTR group based on a receiver-operating characteristic curve cutoff of 1.132 of the right atrial/right ventricular area ratio. TR improvement after TAVR was observed in significantly less patients with afTR compared with non-afTR (31.1% vs 60.6%; P < 0.001). Multivariate regression analysis confirmed afTR as independent predictor for TR persistence (adjusted OR: 2.80; 95% CI: 1.66-4.76; P < 0.001). Moreover, afTR was associated with aggravation of TR after TAVR (17.0% vs 6.8%; P = 0.013). Three-year all-cause mortality was significantly higher in patients with persistence compared with patients with improvement of TR (P < 0.001). CONCLUSIONS: In TAVR patients, afTR is an independent predictor for TR persistence. Moreover, TR persistence is associated with increased 3-year all-cause mortality.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Átrios do Coração , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
10.
Clin Res Cardiol ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748208

RESUMO

BACKGROUND: Right ventricular (RV) dysfunction in patients undergoing transcatheter aortic valve implantation (TAVI) for aortic stenosis (AS) has long been disregarded. We aimed to assess the predictive value of RV to pulmonary artery coupling (RV/PAc), defined as tricuspid annular plane systolic excursion to systolic pulmonary artery pressure, on mortality in different flow types of AS after TAVI. METHODS: All patients undergoing TAVI for AS at our centre between 2018 and 2020 were assessed; 862 patients were analysed. The cohort was dichotomized using a ROC analysis (cut-off 0.512 mm/mmHg), into 429 patients with preserved and 433 patients with reduced RV/PAc. RESULTS: Reduced RV/PAc was associated with male sex and a higher rate of comorbidities. Short-term VARC-3 endpoints and NYHA classes at follow-up were comparable. Reduced RV/PAc was associated with higher 2-year all-cause mortality (35.0% [30.3-39.3%] vs. 15.4% [11.9-18.7%], hazard ratio 2.5 [1.9-3.4], p < 0.001). Cardiovascular mortality was almost tripled. Results were consistent after statistical adjustment and in a multivariate model. Sub-analyses of AS flow types revealed lower RV/PAc in classical and paradoxical low-flow low-gradient AS, with the majority having reduced RV/PAc (74% and 59%). RV/PAc retained its predictive value in these subgroups. CONCLUSIONS: RV dysfunction defined by low RV/PAc is a strong mortality predictor after TAVI independent of flow group. It should be incorporated in future TAVI risk assessment.

11.
Basic Res Cardiol ; 108(6): 388, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24065117

RESUMO

Endogenous circulation of bone marrow-derived cells (BMCs) was observed in patients with dilated cardiomyopathy (DCM) who showed cardiac upregulation of Vascular Cell Adhesion Protein-1 (VCAM-1). However, the underlying pathophysiology is currently unknown. Thus, we aimed to analyze circulation, migration and G-CSF-based mobilization of BMCs in a murine model of virus-induced DCM. Mice with coxsackievirus B3 (CVB3) induced DCM and healthy controls were analyzed regarding their myocardial homing factors by PCR. To determine cardiac VCAM-1 expression ELISA and immunohistochemistry were applied. Flow cytometry was performed to analyze BMCs. Cardiac diameters and function were evaluated by echocardiography before and 4 weeks after G-CSF treatment. In murine CVB3-induced DCM an increase of BMCs in peripheral blood and a decrease of BMCs in bone marrow was observed. We found an enhanced migration of Very Late Antigen-4 (VLA-4⁺) BMCs to the diseased heart overexpressing VCAM-1 and higher numbers of CD45⁻CD34⁻Sca-1⁺ and CD45⁻CD34⁻c-kit⁺ cells. Mobilization of BMCs by G-CSF boosted migration along the VCAM-1/VLA-4 axis and reduced apoptosis of cardiomyocytes. Significant improvement of cardiac function was detected by echocardiography in G-CSF-treated mice. Blocking VCAM-1 by a neutralizing antibody reduced the G-CSF-dependent effects on stem cell migration and cardiac function. This is the first study showing that in virus-induced DCM VCAM-1/VLA-4 interaction is crucial for recruitment of circulating BMCs leading to beneficial anti-apoptotic effects resulting in improved cardiac function after G-CSF-induced mobilization.


Assuntos
Células da Medula Óssea/citologia , Cardiomiopatia Dilatada/fisiopatologia , Movimento Celular/fisiologia , Integrina alfa4beta1/metabolismo , Molécula 1 de Adesão de Célula Vascular/metabolismo , Animais , Cardiomiopatia Dilatada/metabolismo , Cardiomiopatia Dilatada/virologia , Infecções por Coxsackievirus , Modelos Animais de Doenças , Ecocardiografia , Ensaio de Imunoadsorção Enzimática , Citometria de Fluxo , Fator Estimulador de Colônias de Granulócitos/metabolismo , Fator Estimulador de Colônias de Granulócitos/farmacologia , Humanos , Imuno-Histoquímica , Camundongos , Reação em Cadeia da Polimerase em Tempo Real , Células-Tronco/citologia
12.
J Cardiovasc Transl Res ; 16(1): 152-154, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35668315

RESUMO

Our study investigated the feasibility to measure pressure profiles inside the inflation balloon during direct implantation of Edwards Sapien 3 ultra-prostheses using an additional syringe with a digital pressure read-out. Pressure profiles of 15 patients for 26 mm valve size were analyzed. Uniform patterns were found for 5 patients similar to those of previously acquired in vitro curves. 10 patients showed strikingly different pressure profiles compared to the above-mentioned group, marked by an earlier pressure increase, single or multiple pressure drops or higher overall pressure. Measuring the percentage of under-expansion of the prostheses, using calibrated angiographic projections revealed a significant difference between both groups. Our data raises the hypothesis that the acquisition of pressure profiles might help to better understand not only the implantation procedure itself but also the highly individual patient-device interaction, offering new information and a new perspective on optimization of TAVR implantation in the future.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Resultado do Tratamento , Desenho de Prótese
13.
Int J Cardiol ; 376: 100-107, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36758861

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a well-established, safe and effective therapy for severe symptomatic aortic stenosis (AS). The aim of this study was to objectively quantify improvement of physical activity after TAVR, with consideration of different low-gradient AS subtypes. METHODS AND RESULTS: All patients undergoing TAVR for severe AS were screened. Participants received a wearable activity tracker (Fitbit®) at hospital discharge following TAVR and 6 months thereafter. The difference of median daily steps was defined as surrogate outcome for physical activity. For analysis, patients were grouped into high-gradient (HG) AS (dPmean ≥40 mmHg), classical low-flow low-gradient (LFLG) AS (dPmean <40 mmHg, EF <50%), paradoxical LFLG-AS (dPmean <40 mmHg, EF ≥50%, SVi ≤35 ml/m2) and normal-flow low-gradient (NFLG) AS (dPmean <40 mmHg, EF ≥50%, SVi >35 ml/m2) according to mean transvalvular pressure gradient (dPmean), stroke volume index (SVi) and left-ventricular ejection fraction (LVEF). RESULTS AND CONCLUSIONS: The analysis is based on 230 patients. The median daily step count was 4409 [IQR 2581-7487] after hospital discharge and 5326 [IQR 3045-8668] 6 months thereafter. Median difference of daily steps was ∆529 [IQR -702-2152]). Patients with HG-AS and paradoxical LFLG-AS showed a significant improvement of daily steps (∆951 [IQR -378-2323], p <0.001 and (∆1392 [IQR -609-4444], p = 0.02, respectively). Patients with classical LFLG-AS showed no statistically relevant improvement of daily steps (∆192 [IQR -687-770], p = 0.79). Patients with NFLG-AS showed a numerical decline in daily steps without statistical significance (∆-300 [IQR -1334-1406], p = 0.67). This first prospective study of this sample size shows significant improvement of physical activity after TAVR with an objective and reproducible method. This was mainly driven by an improvement in patients with HG-AS and paradoxical LFLG-AS.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estudos Prospectivos , Volume Sistólico , Função Ventricular Esquerda , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Exercício Físico , Resultado do Tratamento , Índice de Gravidade de Doença
14.
Clin Res Cardiol ; 112(5): 645-655, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36637479

RESUMO

AIM: The aim of this study was to analyse the predictive value of CTA-determined tricuspid annular dilatation (TAD) on the persistence of tricuspid regurgitation (TR) in patients undergoing transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) and concomitant at least moderate TR. METHODS AND RESULTS: 288 consecutive patients treated with TAVR due to severe AS and concomitant at least moderate TR at baseline were included in the analysis. As cutoff for TAD, the median value of the CTA-determined, to the body surface area-normalized tricuspid annulus diameter (25.2 mm/m2) was used. TAD had no impact on procedural characteristics or outcomes, including procedural death and technical or device failure according to the Valve Academic Research Consortium 3 criteria. However, the primary outcome of the study-TR persistence after TAVR was significantly more frequent in patients with compared to patients without TAD (odds ratio 2.60, 95% confidence interval 1.33-5.16, p < 0.01). Multivariable logistic regression analysis, adjusting for clinical and echocardiographic baseline characteristics, which are known to influence aetiology or severity of TR, confirmed TAD as an independent predictor of TR persistence after TAVR (adjusted odds ratio 2.30, 95% confidence interval 1.20-4.46, p = 0.01). Moreover, 2 year all-cause mortality was significantly higher in patients with persistence or without change of TR compared to patients with TR improvement (log-rank p < 0.01). CONCLUSION: In patients undergoing TAVR for severe AS and concomitant at least moderate TR at baseline, TAD is a predictor of TR persistence, which is associated with increased 2-year all-cause mortality.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/etiologia , Dilatação/efeitos adversos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Retrospectivos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Índice de Gravidade de Doença
15.
Int J Cardiol ; 371: 299-304, 2023 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-36306951

RESUMO

BACKGROUND: Normal-flow (stroke volume index, SVi >35 ml/m2) low-gradient (dPmean <40 mmHg) aortic stenosis (NFLG-AS) is subject of scientific debate. Guidelines fail to give conclusive treatment recommendations. We hypothesized that NFLG patients are heterogenous, containing a subgroup similar to high-gradient aortic stenosis patients (dPmean ≥40 mmHg, HG-AS) concerning characteristics and outcomes. METHODS: 2326 patients undergoing transcatheter aortic valve replacement (TAVI) at our centre between 2013 and 2019 were analysed. 386 patients fulfilled criteria of NFLG-AS. Their median dPmean was 33 mmHg, which was used for grouping (204 patients with higher gradient NFLG-AS, 186 patients with lower gradient NFLG-AS). They were compared to 956 HG-AS patients. RESULTS: Characteristics of lower gradient NFLG-AS patients differed from HG-AS patients in many aspects while higher gradient NFLG-AS and HG-AS patients were mostly similar, underscored by higher Society of Thoracic Surgeons scores in lower gradient NFLG-AS (lower gradient NFLG-AS, 3.9, HG-AS, 3.0, p = 0.03, higher gradient NFLG-AS, 3.0, p = 0.04). Procedural complications were comparable. Estimated 3-year all-cause mortality was higher in lower gradient NFLG-AS compared to HG-AS patients (hazard ratio 1.7, p < 0.01), whereas mortality of higher gradient NFLG-AS was similar to HG-AS patients (hazard ratio 1.2, p = 0.31). Cardiovascular mortality was highest among lower gradient NFLG-AS patients (21.6% vs. higher gradient NFLG-AS, 15.4%, vs. HG-AS, 11.1%, p < 0.01). CONCLUSIONS: NFLG-AS patients are indeed heterogenous. NFLG-AS patients with higher gradients resemble HG-AS patients in clinical characteristics and outcomes and should not be treated differently. Lower gradient NFLG-AS patients have increased long-term mortality and the use of TAVI requires careful consideration.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Função Ventricular Esquerda , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Índice de Gravidade de Doença
16.
EuroIntervention ; 19(6): 526-536, 2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37042426

RESUMO

BACKGROUND: Concomitant moderate/severe mitral regurgitation (MR) is observed in 17-35% of patients undergoing transcatheter aortic valve implantation (TAVI) and contributes to a worse prognosis. Studies analysing outcomes in patients undergoing TAVI with different MR aetiologies, including atrial functional MR (aFMR), are lacking. AIMS: We aimed to analyse outcomes and changes in MR severity in patients with aFMR, ventricular functional (vFMR) and primary mitral regurgitation (PMR) following TAVI. METHODS: We analysed all consecutive patients with at least moderate MR undergoing TAVI between January 2013 and December 2020 at the Munich University Hospital. Characterisation of MR aetiology was performed by detailed individual echocardiographic assessment. Three-year mortality, changes in MR severity and New York Heart Association (NYHA) Functional Class at follow-up were assessed. RESULTS: Out of 3,474 patients undergoing TAVI, 631 patients showed MR ≥2+ (172 with aFMR, 296 with vFMR, 163 with PMR). Procedural characteristics and endpoints were comparable between groups. The rate of MR improvement was 80.2% in aFMR patients, which was significantly higher compared to both other groups (vFMR: 69.4%; p=0.03; PMR: 40.8%; p<0.001). The estimated 3-year survival rates did not differ between aetiologies (p=0.57). However, MR persistence at follow-up was associated with increased mortality (hazard ratio 1.49, 95% confidence interval: 1.04-2.11; p=0.027), mainly driven by the PMR subgroup of patients. NYHA Class improved significantly in all groups. In patients with baseline MR ≥3+, the PMR aetiology was associated with the lowest MR improvement, the lowest survival rates and least symptomatic improvement. CONCLUSIONS: TAVI reduces MR severity and symptoms in patients with aFMR, vFMR and less-pronounced PMR. The presence of aFMR was associated with the greatest MR severity improvement.


Assuntos
Estenose da Valva Aórtica , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Resultado do Tratamento , Prognóstico , Ecocardiografia , Estenose da Valva Aórtica/diagnóstico , Índice de Gravidade de Doença , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
17.
Front Cardiovasc Med ; 10: 1106114, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36776253

RESUMO

Background: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a valuable treatment option for patients in cardiogenic shock, but complications during decannulation may worsen the overall outcome. Therefore, the aim of this study was to compare the efficacy and safety of suture-based to pure plug-based vascular closure devices for VA-ECMO decannulation. Methods: In this retrospective study, the procedural outcome of 33 patients with suture-based Perclose ProGlide closure devices was compared to 38 patients with MANTA plug-based closure devices. Results: Rate of technically correct placement of closure devices was 88% in the suture-based group and 97% in the plug-based group (p = 0.27). There was a significant reduction of severe bleeding events during VA-ECMO decannulation in plug-based versus suture-based systems (3% vs. 21%, p = 0.04). Ischemic complications occurred in 6% with suture-based and 5% with plug-based device (p = 1.00). Pseudoaneurysm formation was detected in 3% in both groups (p = 1.00). No switch to vascular surgery due to bleeding after decannulation was necessary in both groups. Conclusion: Based on our retrospective analysis, we propose that plug-based vascular closure should be the preferred option for VA-ECMO decannulation. This hypothesis should be further tested in a randomized trial.

18.
JACC Cardiovasc Interv ; 16(16): 1965-1973, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37648344

RESUMO

BACKGROUND: Patients with severe aortic regurgitation (AR) are often not considered for surgery because of increased surgical risk. Because of unique anatomical characteristics among patients with AR, interventional treatment options are limited, and implantation results are inconsistent compared with those among patients with aortic stenosis. OBJECTIVES: The authors describe the initial commercial experience of the first Conformité Européenne-marked transfemoral transcatheter aortic valve replacement system (JenaValve Trilogy [JV]) for the treatment of patients with AR. METHODS: This multicenter registry included 58 consecutive patients from 6 centers across Germany. Transcatheter aortic valve replacement was performed with the JV system for isolated severe and symptomatic AR. Patient characteristics, primary implantation outcomes, and valve performance up to 30 days were analyzed using Valve Academic Research Consortium 3 definitions. RESULTS: The mean patient age was 76.5 ± 9 years, with a mean Society of Thoracic Surgeons score of 4.2% ± 4.3%. Device success was achieved in 98% of patients. The mean gradient was 4.3 ± 1.6 mm Hg, and no moderate or severe paravalvular regurgitation occurred. No conversion to open heart surgery or valve embolization was reported. There were no major vascular complications or bleeding events. The rate of new permanent pacemaker implantation was 19.6%. At 30 days, 92% of the patients were in NYHA functional class I or II, and the 30-day mortality rate was 1.7%. CONCLUSIONS: Treatment of patients with severe symptomatic AR using the transfemoral JV system is safe and effective. Given its favorable hemodynamic performance and low complication rates, this system may offer a new treatment option for patients with AR not suitable for surgery.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Coração , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
19.
J Clin Med ; 12(1)2023 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-36615162

RESUMO

Background: Heparin-induced thrombocytopenia (HIT) is a serious, immune-mediated adverse drug reaction to unfractionated heparin (UFH) affecting also patients undergoing venoarterial extracorporeal membrane oxygenation (VA-ECMO). Although the association between VA-ECMO support and the development of thrombocytopenia has long been known and discussed, HIT as one underlying cause is still insufficiently understood. Therefore, the purpose of this study was to further investigate the epidemiology, mortality, diagnosis, and clinical management of HIT occurring in VA-ECMO patients treated with UFH. Methods: We conducted a retrospective single-center study including adult patients (≥18 years) with VA-ECMO support in the cardiac intensive care unit (ICU) of the University Hospital of Munich (LMU) between January 2013 and May 2022, excluding patients with a known history of HIT upon admission. Differences in baseline characteristics and clinical outcome between excluded HIT (positive anti-platelet factor 4 (PF4)/heparin antibody test but negative functional assay) and confirmed HIT (positive anti-PF4/heparin antibody test and positive functional assay) VA-ECMO patients as well as diagnosis and clinical management of HIT were analysed. Results: Among the 373 patients included, anti-PF4/heparin antibodies were detected in 53/373 (14.2%) patients. Functional HIT testing confirmed HIT in 13 cases (3.5%) and excluded HIT in 40 cases (10.7%), corresponding to a prevalence of confirmed HIT of 13/373 (3.5%) [1.6, 5.3] and a positive predictive value (PPV) of 24.5% for the antibody screening test. The platelet course including platelet recovery following argatroban initiation was similar between all groups. One-month mortality in patients with excluded HIT was 14/40 (35%) and 3-month mortality 17/40 (43%), compared to 5/13 (38%) (p > 0.999), and 6/13 (46%) (p > 0.999) in patients with confirmed HIT. Neurological outcome in both groups measured by the cerebral performance category of survivors on hospital discharge was similar, as well as adverse events during VA-ECMO therapy. Conclusions: With a prevalence of 3.5%, HIT is a non-frequent complication in patients on VA-ECMO and was not associated with a higher mortality rate. HIT was ultimately excluded by functional essay in 75% of VA-ECMO patients with clinical suspicion of HIT and positive anti-PF4/heparin antibody test. Argatroban seems to be an appropriate and safe therapeutic option for confirmed HIT-positive patients on VA-ECMO support.

20.
Clin Res Cardiol ; 112(10): 1427-1435, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37337011

RESUMO

BACKGROUND: Cardiohepatic syndrome (CHS) has been identified as an important but underrecognized survival predictor in multiple cardiovascular disease entities. The objectives of this study were to evaluate the prevalence and prognostic value of CHS in patients undergoing TAVR for severe aortic stenosis (AS). METHODS: The study included patients with available laboratory parameters of hepatic function who underwent TAVR from July 2013 until December 2019 at our center. CHS was defined as an elevation of at least two of three laboratory cholestasis parameters above the upper limit of normal (bilirubin, alkaline phosphatase, and gamma glutamyl transferase). Study endpoints were three-year survival, technical and device failure (VARC 3), as well as New York Heart Association (NYHA) functional class at follow-up. RESULTS: Among a total of 953 analyzed patients (47.6% females, median age 80.0 [76.0-85.0] years) CHS was present in 212 patients (22.4%). In patients with vs. without CHS, rates of technical (6.1% vs. 8.4%, p = 0.29) and device failure (18.9% vs. 17.3%, p = 0.59) were comparable. NYHA functional class at baseline and follow-up was more severe in patients with CHS. Nevertheless, heart failure symptoms improved from baseline to follow-up irrespective of hepatic function. Three-year survival rates were significantly lower in patients with CHS (49.4 vs. 65.4%, p < 0.001). The predictive value of CHS persisted after adjustment in a multivariable analysis (hazard ratio 1.58, p < 0.01). CONCLUSION: In patients undergoing TAVR, CHS is prevalent in 22% of patients and is associated with increased postinterventional mortality. Thus, CHS should be included in the decision-making process within the TAVR heart team. Cardiohepatic syndrome (CHS) as defined by an elevation of at least two of three laboratory cholestasis parameters above the upper limit of normal was prevalent in 22% of patients undergoing TAVR for severe AS. The presence of CHS was associated with more severe heart failure symptoms and worse three-year survival.


Assuntos
Estenose da Valva Aórtica , Colestase , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA