Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Ann Biol Clin (Paris) ; 72(4): 423-34, 2014.
Artigo em Francês | MEDLINE | ID: mdl-25119800

RESUMO

We evaluated the analytical performances of the SPAPLUS(®) immunoturbidimeter assays manufactured by The Binding Site(®) for the quantification of thirteen immunological parameters in serum: IgG, IgA, IgM and IgD immunoglobulins, IgG subclasses (1 to 4), IgA subclasses (1 and 2), beta-2 microglobulin, free light chains kappa and lambda. The within-day precision (repeatability) and the between-day precision (reproducibility) were obtained for two or three concentration levels depending of the parameter and were below the recommendations of the manufacturer, except for the repeatability of IgG1 (at a level of concentration of 6.7 g/L). An agreement above 90% (with Bland and Altman analysis) was observed between the results obtained with SPAPLUS(®) and those obtained with the nephelometer IMMAGE(®) 800 or radial immunodiffusion. The evaluation confirmed the linearity of the assays and the absence of contamination for all the parameters tested. We also assessed the practicability of the SPAPLUS(®) in terms of maintenance, frequency of calibration and cadence tests. The SPAPLUS(®) immunoturbidimeter displays good analytical performances for the immunological parameters evaluated in the present work.


Assuntos
Imunoglobulinas/sangue , Testes Imunológicos/instrumentação , Nefelometria e Turbidimetria/instrumentação , Microglobulina beta-2/sangue , Humanos , Reprodutibilidade dos Testes
2.
Clin Vaccine Immunol ; 16(5): 772-4, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19321696

RESUMO

We have evaluated three anti-hepatitis E virus (anti-HEV) immunoglobulin M (IgM) assays, the EIAgen HEV IgM assay (Adaltis), the HEV IgM enzyme-linked immunosorbent assay 3.0, and the Assure HEV IgM rapid test (MP Diagnostics), for the routine detection of acute genotype 3 HEV. Their sensitivities were fairly good (90%, 88%, and 82%), and their specificities were excellent (100%, 99.5%, and 100%).


Assuntos
Anticorpos Anti-Hepatite/sangue , Hepatite E/diagnóstico , Imunoglobulina M/sangue , Hepatite E/imunologia , Vírus da Hepatite E/classificação , Vírus da Hepatite E/imunologia , Humanos , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA