Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
2.
J Synchrotron Radiat ; 25(Pt 4): 1238-1248, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29979187

RESUMO

The SwissFEL Aramis beamline, covering the photon energies between 1.77 keV and 12.7 keV, features a suite of online photon diagnostics tools to help both users and FEL operators in analysing data and optimizing experimental and beamline performance. Scientists will be able to obtain information about the flux, spectrum, position, pulse length, and arrival time jitter versus the experimental laser for every photon pulse, with further information about beam shape and size available through the use of destructive screens. This manuscript is an overview of the diagnostics tools available at SwissFEL and presents their design, working principles and capabilities. It also features new developments like the first implementation of a THz-streaking based temporal diagnostics for a hard X-ray FEL, capable of measuring pulse lengths to 5 fs r.m.s. or better.

3.
J Synchrotron Radiat ; 21(Pt 2): 340-51, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24562555

RESUMO

A new diffractometer for microcrystallography has been developed for the three macromolecular crystallography beamlines of the Swiss Light Source. Building upon and critically extending previous developments realised for the high-resolution endstations of the two undulator beamlines X06SA and X10SA, as well as the super-bend dipole beamline X06DA, the new diffractometer was designed to the following core design goals. (i) Redesign of the goniometer to a sub-micrometer peak-to-peak cylinder of confusion for the horizontal single axis. Crystal sizes down to at least 5 µm and advanced sample-rastering and scanning modes are supported. In addition, it can accommodate the new multi-axis goniometer PRIGo (Parallel Robotics Inspired Goniometer). (ii) A rapid-change beam-shaping element system with aperture sizes down to a minimum of 10 µm for microcrystallography measurements. (iii) Integration of the on-axis microspectrophotometer MS3 for microscopic sample imaging with 1 µm image resolution. Its multi-mode optical spectroscopy module is always online and supports in situ UV/Vis absorption, fluorescence and Raman spectroscopy. (iv) High stability of the sample environment by a mineral cast support construction and by close containment of the cryo-stream. Further features are the support for in situ crystallization plate screening and a minimal achievable detector distance of 120 mm for the Pilatus 6M, 2M and the macromolecular crystallography group's planned future area detector Eiger 16M.

4.
J Synchrotron Radiat ; 20(Pt 5): 765-76, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23955041

RESUMO

The combination of X-ray diffraction experiments with optical methods such as Raman, UV/Vis absorption and fluorescence spectroscopy greatly enhances and complements the specificity of the obtained information. The upgraded version of the in situ on-axis micro-spectrophotometer, MS2, at the macromolecular crystallography beamline X10SA of the Swiss Light Source is presented. The instrument newly supports Raman and resonance Raman spectroscopy, in addition to the previously available UV/Vis absorption and fluorescence modes. With the recent upgrades of the spectral bandwidth, instrument stability, detection efficiency and control software, the application range of the instrument and its ease of operation were greatly improved. Its on-axis geometry with collinear X-ray and optical axes to ensure optimal control of the overlap of sample volumes probed by each technique is still unique amongst comparable facilities worldwide and the instrument has now been in general user operation for over two years.


Assuntos
Cristalografia por Raios X , Análise Espectral Raman/instrumentação , Desenho Assistido por Computador , Cristalografia por Raios X/instrumentação , Cristalografia por Raios X/métodos , Desenho de Equipamento , Substâncias Macromoleculares , Reprodutibilidade dos Testes , Software , Espectrometria de Fluorescência/instrumentação , Espectrometria de Fluorescência/métodos , Espectrofotometria Ultravioleta/instrumentação , Espectrofotometria Ultravioleta/métodos , Análise Espectral Raman/métodos
5.
Phys Med Biol ; 66(13)2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34126607

RESUMO

The introduction of non-invasive imaging techniques such as MRI imaging for treatment planning and optical eye tracking for in-room eye localization would obviate the requirement of clips implantation for many patients undergoing ocular proton therapy. This study specifically addresses the issue of torsional eye movement detection during patient positioning. Non-invasive detection of eye torsion is performed by measuring the iris pattern rotations using a beams eye view optical camera. When handling images of patients to be treated using proton therapy, a number of additional challenges are encountered, such as changing eye position, pupil dilatation and illumination. A method is proposed to address these extra challenges while also compensating for the effect of cornea distortion in eye torsion computation. The accuracy of the proposed algorithm was evaluated against corresponding measurement of eye torsion using the clips configuration measured on x-ray images. This study involves twenty patients who received ocular proton therapy at Paul Scherrer Institute and it is covered by ethical approval (EKNZ 2019-01987).


Assuntos
Terapia com Prótons , Movimentos Oculares , Face , Humanos , Iris , Imagem Óptica
6.
J Synchrotron Radiat ; 16(Pt 2): 173-82, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19240329

RESUMO

X-ray crystallography at third-generation synchrotron sources permits tremendous insight into the three-dimensional structure of macromolecules. Additional information is, however, often required to aid the transition from structure to function. In situ spectroscopic methods such as UV-Vis absorption and (resonance) Raman can provide this, and can also provide a means of detecting X-ray-induced changes. Here, preliminary results are introduced from an on-axis UV-Vis absorption and Raman multimode spectrometer currently being integrated into the beamline environment at X10SA of the Swiss Light Source. The continuing development of the spectrometer is also outlined.


Assuntos
Cristalografia por Raios X/instrumentação , Substâncias Macromoleculares/química , Espectrofotometria Ultravioleta/instrumentação , Desenho Assistido por Computador , Cristalografia por Raios X/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA