Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Qual Life Res ; 29(11): 3017-3029, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32857268

RESUMO

PURPOSE: While several studies have investigated clinical outcomes following coronary artery bypass grafting (CABG) vs. percutaneous coronary intervention (PCI), studies investigating self-reported health and the association with adverse outcomes are limited. Thus, the aim was to investigate differences in health-related quality of life (HRQoL), anxiety and depression at discharge and the association with a composite endpoint of the first event of acute cardiac readmission, revascularisation or 1-year mortality among patients undergoing CABG vs. PCI. METHODS: Data from the national cohort study, DenHeart, were used, including measures of HRQoL; EuroQoL-5D-5L (EQ-5D Index Score and VAS) and HeartQoL (Global, Physical and Emotional), anxiety and depression (Hospital Anxiety and Depression Scale, HADS) and register-based follow-up. A total of 7000 patients were included (CABG n = 652, PCI n = 6348) (median age 65, 75% men). Cox Proportional Hazard models were performed among a propensity-matched population of responders (n = 520). RESULTS: HRQoL was significantly better among patients undergoing PCI vs. CABG, but with no differences in time to readmission or revascularisation. HRQoL, anxiety and depression were significantly associated with the risk of the composite endpoint among the PCI group (Hazard Ratio, HR (95% confidence intervals, CI) [EQ-5D index score 3.07 (1.67-5.67), EQ-5D VAS 0.97 (0.96-0.99), HeartQol Global 0.61 (0.38-0.95), HeartQol Emotional 0.56 (0.39-0.80), HADS-D ≥ 8 3.12 (1.61-6.01), HADS-A ≥ 8 2.08 (1.14-3.80)]. CONCLUSION: Patients undergoing PCI reported better HRQoL at discharge compared with patients undergoing CABG, whereas readmission rates were similar. Self-reported health was associated with the risk of adverse events among patients undergoing PCI, but not among patients undergoing CABG. CLINICAL TRIAL REGISTRATION: NCT01926145.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/diagnóstico , Nível de Saúde , Intervenção Coronária Percutânea/efeitos adversos , Qualidade de Vida/psicologia , Autorrelato/normas , Idoso , Estudos de Coortes , Ponte de Artéria Coronária/métodos , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento
2.
Circ Cardiovasc Qual Outcomes ; 14(6): e007302, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34078097

RESUMO

BACKGROUND: In coronary artery bypass grafting (CABG), the use of fractional flow reserve (FFR) is insufficiently investigated. Stenosis assessment usually relies on visual estimates of lesion severity. This study evaluated health-related quality of life (HRQoL) and angina after FFR- versus angiography-guided CABG. METHODS: One hundred patients referred for CABG were randomized to FFR- or angiography-guided CABG. In the FFR group, lesions with FFR>0.80 were deferred, while the surgeon was blinded to the FFR values in the angiography group. Before and 6 months after CABG, HRQoL was assessed by the health state classifier EQ-5D of the EuroQoL 5-level instrument and angina status based on the Canadian Cardiovascular Society classification system were registered. RESULTS: Six-month angiography included FFR evaluations of deferred lesions. In total, completed EQ-5D of the EuroQoL 5-level instrument questionnaires were available in 86 patients (43 in the FFR versus 43 in the angiography-guided group). HRQoL was significantly improved and angina significantly decreased from baseline to 6 months after CABG with no difference between the randomization groups. Graft failure rates and clinical outcomes were similar in both groups. Patients with graft failure or FFR<0.80 of the previous deferred lesions had significantly lower visual analogue scale scores (78.7±14.2 versus 86.8±14.7, P=0.004) and more angina compared with patients without graft failure or FFR≥0.80 at 6-month follow-up. CONCLUSIONS: FFR- versus angiography-guided CABG demonstrated similar improvements in HRQoL and angina 6 months after CABG. Graft failure or low FFR in deferred lesions were associated with low HRQoL and angina. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02477371.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Trialato , Canadá , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Qualidade de Vida , Distribuição Aleatória , Resultado do Tratamento
3.
J Am Coll Cardiol ; 72(22): 2732-2743, 2018 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-30497559

RESUMO

BACKGROUND: The value of fractional flow reserve (FFR) evaluation of coronary artery stenosis in coronary artery bypass grafting (CABG) is uncertain, and stenosis assessments usually rely on visual estimates of lesion severity. OBJECTIVES: This randomized clinical trial evaluated graft patency and clinical outcome after FFR-guided CABG versus angiography-guided CABG. METHODS: A total of 100 patients referred for CABG were randomly assigned to FFR-guided or angiography-guided CABG. Based on the coronary angiogram, a heart team made a graft plan for all patients, and FFR evaluations were performed. In FFR-guided CABG, coronary lesions with FFR >0.80 were deferred, and a new graft plan was designed accordingly, whereas the surgeon was blinded to the FFR values in patients who underwent angiography-guided CABG. The primary endpoint was graft failure in the percentage of all grafts after 6 months. RESULTS: Angiographic follow-up at 6 months was available for 72 patients (39 vs. 33 in the FFR-guided and angiography-guided groups, respectively). Graft failures of all grafts were similar in both groups (16% vs. 12%; p = 0.97). Rates of death, myocardial infarction, and stroke were also similar in the study groups, and no difference was seen in revascularization before angiographic follow-up. After 6 months, deferred lesions (n = 24) showed a significant reduction in mean FFR from index to follow-up (0.89 ± 0.05 vs. 0.81 ± 0.11; p = 0.002). Index FFR did not influence graft patency. CONCLUSIONS: FFR-guided CABG had similar graft failure rates and clinical outcomes as angiography-guided CABG. However, FFR was reduced significantly after 6 months in deferred lesions. (Fractional Flow Reserve Versus Angiography Randomization for Graft Optimization [FARGO]; NCT02477371).


Assuntos
Angiografia Coronária/métodos , Ponte de Artéria Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Idoso , Angiografia Coronária/efeitos adversos , Angiografia Coronária/mortalidade , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Estenose Coronária/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Estudos Prospectivos , Método Simples-Cego , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA