Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Rev Sci Instrum ; 93(9): 093520, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182523

RESUMO

A new deuterium-tritium experimental, DTE2, campaign has been conducted at the Joint European Torus (JET) between August 2021 and late December 2021. Motivated by significant enhancements in the past decade at JET, such as the ITER-like wall and enhanced auxiliary heating power, the campaign achieved a new fusion energy world record and performed a broad range of fundamental experiments to inform ITER physics scenarios and operations. New capabilities in the area of fusion product measurements by nuclear diagnostics were available as a result of a decade long enhancement program. These have been tested for the first time in DTE2 and a concise overview is provided here. Confined alpha particle measurements by gamma-ray spectroscopy were successfully demonstrated, albeit with limitations at neutron rates higher than some 1017 n/s. High resolution neutron spectroscopy measurements with the magnetic proton recoil instrument were complemented by novel data from a set of synthetic diamond detectors, which enabled studies of the supra-thermal contributions to the neutron emission. In the area of escaping fast ion diagnostics, a lost fast ion detector and a set of Faraday cups made it possible to determine information on the velocity space and poloidal distribution of the lost alpha particles for the first time. This extensive set of data provides unique information for fundamental physics studies and validation of the numerical models, which are key to inform the physics and scenarios of ITER.

2.
Rev Sci Instrum ; 92(4): 043553, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243489

RESUMO

The JET FILD is a scintillator-based Fast-ion Loss Detector optimized to measure fusion-born alpha-particle losses. This work covers its upgrade and absolute calibration in preparation for the following JET DT experiments. A fast scintillator material (TG-Green) has been installed in the JET FILD. A heater jacket is installed around the fiber bundle, responsible for transmitting the light from the scintillator plate, to anneal the fiber obscuring due to neutron damage. The JET FILD has been upgraded with a 1 Mpx camera and 2 MHz photomultiplier data acquisition hardware. Full-orbit simulations give an estimate of the shading effects on the scintillator plate of the first wall structures and provide a synthetic signal of the JET FILD. A detector instrument function enables absolute values of fast-ion losses using calibration factors. The calibration factors are made available in a shot-to-shot basis for the characterized species and energies and with corrections for the diagnostic conditions. The fast acquisition system sets the Nyquist frequency (1 MHz) above the typical mode frequencies (≈102 kHz), thus making it possible to identify MHD-induced fast-ion losses.

3.
J Cell Biol ; 147(5): 959-68, 1999 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-10579717

RESUMO

Translocation of nuclear-encoded preproteins across the outer membrane of mitochondria is mediated by the multicomponent transmembrane TOM complex. We have isolated the TOM core complex of Neurospora crassa by removing the receptors Tom70 and Tom20 from the isolated TOM holo complex by treatment with the detergent dodecyl maltoside. It consists of Tom40, Tom22, and the small Tom components, Tom6 and Tom7. This core complex was also purified directly from mitochondria after solubilization with dodecyl maltoside. The TOM core complex has the characteristics of the general insertion pore; it contains high-conductance channels and binds preprotein in a targeting sequence-dependent manner. It forms a double ring structure that, in contrast to the holo complex, lacks the third density seen in the latter particles. Three-dimensional reconstruction by electron tomography exhibits two open pores traversing the complex with a diameter of approximately 2.1 nm and a height of approximately 7 nm. Tom40 is the key structural element of the TOM core complex.


Assuntos
Proteínas de Transporte/química , Membranas Intracelulares/enzimologia , Proteínas de Membrana/química , Mitocôndrias/enzimologia , Proteínas de Transporte/isolamento & purificação , Proteínas de Transporte/metabolismo , Proteínas de Transporte/ultraestrutura , Proteínas Fúngicas/química , Proteínas Fúngicas/isolamento & purificação , Proteínas Fúngicas/metabolismo , Proteínas Fúngicas/ultraestrutura , Membranas Intracelulares/metabolismo , Membranas Intracelulares/fisiologia , Membranas Intracelulares/ultraestrutura , Canais Iônicos/química , Canais Iônicos/metabolismo , Canais Iônicos/fisiologia , Canais Iônicos/ultraestrutura , Proteínas de Membrana/isolamento & purificação , Proteínas de Membrana/metabolismo , Proteínas de Membrana/ultraestrutura , Mitocôndrias/metabolismo , Mitocôndrias/fisiologia , Mitocôndrias/ultraestrutura , Neurospora crassa/enzimologia , Neurospora crassa/metabolismo , Neurospora crassa/fisiologia , Neurospora crassa/ultraestrutura , Ligação Proteica , Precursores de Proteínas/metabolismo , Precursores de Proteínas/ultraestrutura
4.
Rev Sci Instrum ; 89(10): 10K119, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399696

RESUMO

In order to optimize the scientific exploitation of JET (Joint European Torus) during the upcoming deuterium-tritium experiments, a set of diagnostic systems is being enhanced. These upgrades focus mainly on the experimental and operational conditions expected during tritium campaigns. It should be stressed that measurements relevant for burning plasmas are specifically targeted. Previously non-available capabilities, such as a current measurement system fully covering all poloidal field circuits, are described in detail. Instrument descriptions, performance prediction, testing, and initial commissioning results of these systems are presented.

5.
Rev Sci Instrum ; 87(11): 11D443, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910612

RESUMO

In order to complete the exploitation of the JET ITER-like Wall and to take full benefit from deuterium-tritium experiments on JET, a set of diagnostic system refurbishments or upgrades is in progress. These diagnostic enhancements focus mainly on neutron, gamma, fast ions, instabilities, and operations support. These efforts intend to provide better spatial, temporal, and energy resolution while increasing measurement coverage. Also previously non-existing capabilities, such as Doppler reflectometry is now available for scientific exploitation. Guaranteeing diagnostic reliability and consistency during the expected DT conditions is also a critical objective of the work and systems being implemented. An overview of status and scope of the ongoing projects is presented.

6.
Diabetes Care ; 4(2): 228-34, 1981.
Artigo em Inglês | MEDLINE | ID: mdl-7011733

RESUMO

Biosynthetic human insulin (BHI) obtained from separately synthesized A- and B-chains by recombinant DNA technology with Escherichia coli fermentation was compared with human and pork insulin of high purity in vitro. Applying four biologic tests (glucose oxidation and glucose incorporation into the lipids by rat epididymal fat pads, inhibition of lipolysis, and ATP depletion of isolated fat cells) and three receptor assays (binding competition with human fat cells, IM-9 lymphocytes, and rat liver cell plasma membranes), we could not discern significant differences of the half-maximum response by these seven methods. The only variance occurred with the ATP-depletion assay. This method disclosed 10% greater maximum reversion of isoproterenol-induced ATP depletion by BHI when compared with pork insulin.


Assuntos
Insulina/farmacologia , Trifosfato de Adenosina/metabolismo , Tecido Adiposo/efeitos dos fármacos , Tecido Adiposo/metabolismo , Animais , Membrana Celular/metabolismo , DNA Recombinante/metabolismo , Escherichia coli/metabolismo , Glucose/metabolismo , Humanos , Insulina/análogos & derivados , Insulina/biossíntese , Insulina/metabolismo , Ilhotas Pancreáticas/análise , Mobilização Lipídica/efeitos dos fármacos , Fígado/metabolismo , Masculino , Ratos , Ratos Endogâmicos , Receptor de Insulina/metabolismo , Suínos
7.
Diabetes Res Clin Pract ; 4(4): 269-74, 1988 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-3286166

RESUMO

Effects of constant and pulsatile i.v. insulin delivery were examined in seven healthy subjects by means of euglycemic clamp technique. Each subject received constant insulin infusion (0.175 mU/kg.min) or insulin pulses at 12-min intervals (2.1 mU/kg) in randomized order for 8-h periods (08.00-16.00 h). Endogenous secretion of insulin was inhibited by concomitant administration of somatostatin (300 micrograms/h). Serum insulin concentrations during constant infusion (12 +/- 1 microU/ml) did not differ from basal values (11 +/- 1 microU/ml). Pulsatile insulin delivery resulted in oscillations of mean concentrations between values of about 10 and 20 microU/ml. Mean blood glucose concentrations during experiments were kept at 80 +/- 1 mg/dl, irrespective of the mode of insulin administration. Moreover, dextrose requirements for maintenance of these glucose concentrations did not differ over the hole periods of examination. We conclude that effects of constant and pulsatile delivery of basal amounts of insulin are not different. This at least applies to peripheral, short-term insulin administration in somatostatin-treated normal man, during an euglycemic clamp.


Assuntos
Sistemas de Infusão de Insulina , Insulina/farmacologia , Adulto , Glicemia/metabolismo , Peptídeo C/sangue , Esquema de Medicação , Humanos , Infusões Intravenosas , Insulina/administração & dosagem , Insulina/sangue , Masculino
8.
Rev Sci Instrum ; 81(10): 10E136, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21061488

RESUMO

Notwithstanding the advances of the past decades, significant developments are still needed to satisfactorily diagnose "burning plasmas." D­T plasmas indeed require a series of additional measurements for the optimization and control of the configuration: the 14 MeV neutrons, the isotopic composition of the main plasma, the helium ash, and the redistribution and losses of the alpha particles. Moreover a burning plasma environment is in general much more hostile for diagnostics than purely deuterium plasmas. Therefore, in addition to the development and refinement of new measuring techniques, technological advances are also indispensable for the proper characterization of the next generation of devices. On JET an integrated program of diagnostic developments, for JET future and in preparation for ITER, has been pursued and many new results are now available. In the field of neutron detection, the neutron spectra are now routinely measured in the energy range of 1­18 MeV by a time of flight spectrometer and they have allowed studying the effects of rf heating on the fast ions. A new analysis method for the interpretation of the neutron cameras measurements has been refined and applied to the data of the last trace tritium campaign (TTE). With regard to technological upgrades, chemical vapor deposition diamond detectors have been qualified both as neutron counters and as neutron spectrometers, with a potential energy resolution of about one percent. The in situ calibration of the neutron diagnostics, in preparation for the operation with the ITER-like wall, is also promoting important technological developments. With regard to the fast particles, for the first time the temperature of the fast particle tails has been obtained with a new high purity Germanium detector measuring the gamma emission spectrum from the plasma. The effects of toroidal Alfven eigenmodes modes and various MHD instabilities on the confinement of the fast particles have been determined with a combination of gamma ray cameras, neutral particle analyzers, scintillator probe, and Faraday cups. From a more technological perspective, various neutron filters have been tested to allow measurement of the gamma ray emission also at high level of neutron yield.

12.
Histochemistry ; 86(1): 83-8, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3539893

RESUMO

Biologically active insulin gold complex was used as an ultrastructural marker to study insulin binding sites, uptake, and internalization in isolated rat adipocytes. The preparation conditions for monodispersed particles, ca. 16 nm in diameter and loaded with approximately 100 insulin molecules, are reported. The complex is stable for at least six weeks. Single particles or small clusters were scattered across the cell membrane. The distribution of unbound receptors seemed to be independent of the extensive system of pre-existing surface connected vesicles in adipocytes. The uptake of particles took place predominantly via non-coated pinocytotic invaginations; clathrin-coated pits did not seem to be important for this process. Lysosome-like structures contained aggregates of 10-15 particles. These data suggest that insulin gold complex is a useful marker for the specific labeling of insulin binding sites.


Assuntos
Tecido Adiposo/metabolismo , Ouro , Insulina , Microscopia Eletrônica/métodos , Receptor de Insulina/análise , Tecido Adiposo/ultraestrutura , Animais , Coloides , Histocitoquímica/métodos , Pinocitose , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA