Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Clin Oral Investig ; 28(2): 133, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38315246

RESUMO

OBJECTIVE: The objective of this study was to compare the detection of caries in bitewing radiographs by multiple dentists with an automatic method and to evaluate the detection performance in the absence of a reliable ground truth. MATERIALS AND METHODS: Four experts and three novices marked caries using bounding boxes in 100 bitewing radiographs. The same dataset was processed by an automatic object detection deep learning method. All annotators were compared in terms of the number of errors and intersection over union (IoU) using pairwise comparisons, with respect to the consensus standard, and with respect to the annotator of the training dataset of the automatic method. RESULTS: The number of lesions marked by experts in 100 images varied between 241 and 425. Pairwise comparisons showed that the automatic method outperformed all dentists except the original annotator in the mean number of errors, while being among the best in terms of IoU. With respect to a consensus standard, the performance of the automatic method was best in terms of the number of errors and slightly below average in terms of IoU. Compared with the original annotator, the automatic method had the highest IoU and only one expert made fewer errors. CONCLUSIONS: The automatic method consistently outperformed novices and performed as well as highly experienced dentists. CLINICAL SIGNIFICANCE: The consensus in caries detection between experts is low. An automatic method based on deep learning can improve both the accuracy and repeatability of caries detection, providing a useful second opinion even for very experienced dentists.


Assuntos
Suscetibilidade à Cárie Dentária , Cárie Dentária , Humanos , Radiografia Interproximal , Cárie Dentária/diagnóstico por imagem
2.
Clin Oral Investig ; 27(12): 7463-7471, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37968358

RESUMO

OBJECTIVE: The aim of this work was to assemble a large annotated dataset of bitewing radiographs and to use convolutional neural networks to automate the detection of dental caries in bitewing radiographs with human-level performance. MATERIALS AND METHODS: A dataset of 3989 bitewing radiographs was created, and 7257 carious lesions were annotated using minimal bounding boxes. The dataset was then divided into 3 parts for the training (70%), validation (15%), and testing (15%) of multiple object detection convolutional neural networks (CNN). The tested CNN architectures included YOLOv5, Faster R-CNN, RetinaNet, and EfficientDet. To further improve the detection performance, model ensembling was used, and nested predictions were removed during post-processing. The models were compared in terms of the [Formula: see text] score and average precision (AP) with various thresholds of the intersection over union (IoU). RESULTS: The twelve tested architectures had [Formula: see text] scores of 0.72-0.76. Their performance was improved by ensembling which increased the [Formula: see text] score to 0.79-0.80. The best-performing ensemble detected caries with the precision of 0.83, recall of 0.77, [Formula: see text], and AP of 0.86 at IoU=0.5. Small carious lesions were predicted with slightly lower accuracy (AP 0.82) than medium or large lesions (AP 0.88). CONCLUSIONS: The trained ensemble of object detection CNNs detected caries with satisfactory accuracy and performed at least as well as experienced dentists (see companion paper, Part II). The performance on small lesions was likely limited by inconsistencies in the training dataset. CLINICAL SIGNIFICANCE: Caries can be automatically detected using convolutional neural networks. However, detecting incipient carious lesions remains challenging.


Assuntos
Aprendizado Profundo , Cárie Dentária , Humanos , Cárie Dentária/diagnóstico por imagem , Suscetibilidade à Cárie Dentária , Redes Neurais de Computação
3.
J Prosthet Dent ; 127(5): 750-758, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-33431177

RESUMO

STATEMENT OF PROBLEM: The bonding of light-activated adhesives to root canal dentin with an additional touch-polymerization activator has been insufficiently examined. PURPOSE: The purpose of this in vitro study was to investigate the effect of touch-polymerization activators and extended light-irradiation time on the microtensile bond strength (µTBS) of light-activated adhesives. MATERIAL AND METHODS: Post cavities were prepared in 50 extracted mandibular premolars and bonded using Prime&Bond Universal (PBU); PBU+Self Cure Activator (SCA); Clearfil SE Bond 2 (SEB); SEB+Clearfil DC Activator (DCA); or Clearfil Universal Bond Quick ER (UBQ). After light-irradiation for 10 or 20 seconds, the post cavities were filled with dual-activated resin core materials. Eight beams were prepared per specimen and subjected to the µTBS test. The µTBS data were analyzed by using 3-way ANOVAs with the Bonferroni correction (α=.05). RESULTS: The 3-way ANOVAs indicated that the use of touch-polymerization activators (SCA and DCA) significantly increased the µTBS of PBU and SEB in both the coronal (P=.015) and apical (P=.001) regions. The extension of light-irradiation time to 20 seconds significantly improved their µTBS in the apical region (P<.001), but not in the coronal region (P=.09). Light-irradiation for 20 seconds increased the µTBS of UBQ significantly in the coronal region (P=.014). CONCLUSIONS: Touch-polymerization activators improved the bond strength of light-activated adhesives to root canal dentin, especially when combined with an extended light-irradiation time.


Assuntos
Colagem Dentária , Adesivos Dentinários , Resinas Compostas/química , Cimentos Dentários , Cavidade Pulpar , Dentina , Adesivos Dentinários/química , Teste de Materiais , Polimerização , Cimentos de Resina/química , Resistência à Tração , Tato
4.
J Prosthet Dent ; 126(2): 150-154, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32800576

RESUMO

A straightforward technique is presented for an interim or short-term definitive esthetic replacement of missing anterior teeth requiring no tooth preparation. Composite resins are injected into transparent silicone indices fabricated from 3-dimensional-printed casts of a digital waxing. The dentin core is formed of a durable short fiber-reinforced injectable composite resin and veneered with an enamel-shade composite resin for enhanced esthetics. Besides being noninvasive, this technique is more straightforward than traditional options, reducing chair time while providing an accurate outcome.


Assuntos
Resinas Compostas , Prótese Dentária , Estética Dentária , Humanos , Incisivo , Fluxo de Trabalho
5.
Eur J Oral Sci ; 128(3): 255-262, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32311176

RESUMO

The effect of smear layer-deproteinizing pretreatment using hypochlorous acid (HOCl) on the micro-shear bond strengths (µSBS) of conventional and resin-modified glass-ionomer cements (GIC) to dentin was investigated and compared with demineralizing pretreatment with polyacrylic acid (PAA). Three GICs: Fuji IX GP Extra (restorative conventional GIC), GC Fuji II LC EM (restorative resin-modified GIC), and GC Fuji Luting EX (luting resin-modified GIC), were used. One hundred fifty human molars were divided into groups (n = 10) according to the cements and dentin pretreatments; no pretreatment (control), 10 s PAA pretreatment, and HOCl pretreatment for 5, 15, or 30 s. After 24 h, µSBS was tested and the data were statistically analyzed using a two-way ANOVA, followed by Tukey's post-hoc test. HOCl pretreatment significantly increased µSBS of conventional GIC compared to the control group. For resin-modified restorative GIC, 5 s HOCl deproteinization significantly increased µSBS, while longer application times did not. There was no significant difference between HOCl-pretreated and control groups of resin-modified luting GIC. PAA pretreatment increased the µSBS of all cements significantly. In conclusion, smear layer deproteinization with HOCl can enhance the dentin bonding of conventional GIC. However, the residual radicals may adversely affect the polymerization of resin-modified GICs.


Assuntos
Colagem Dentária , Camada de Esfregaço , Resinas Compostas , Dentina , Cimentos de Ionômeros de Vidro , Humanos , Ácido Hipocloroso , Teste de Materiais , Cimentos de Resina
6.
J Esthet Restor Dent ; 32(7): 638-644, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32603555

RESUMO

OBJECTIVE: Restorative treatment of anterior teeth is often required as the final step of orthodontic therapy to optimize the esthetics and function. This case report presents a direct minimally invasive approach for post-orthodontic recontouring of anterior teeth using the composite injection technique with a digital workflow. CLINICAL CONSIDERATIONS: The extraction of central incisors with short roots was indicated to resolve maxillary anterior crowding. The gained space was closed with lateral incisors, and it was necessary to recontour them and canines to resemble central and lateral incisors, respectively. The restorations were digitally designed, and a transparent silicone index was fabricated from a 3D-printed cast of the digital wax-up. After lateral incisors and canines were bonded with a universal adhesive in the etch-and-rinse mode, a highly filled injectable composite resin was applied into the index. The restorative treatment was preceded by gingivectomy using an Er:YAG laser and home bleaching. CONCLUSIONS: In cases where more complex recontouring of anterior teeth is necessary, the composite injection technique could be a suitable alternative to indirect restorations, because it is straightforward, cost-effective, and does not require any preparation. The digital workflow simplified and expedited the treatment while contributing to its precision. CLINICAL SIGNIFICANCE: Post-orthodontic recontouring using direct composite restorations is well accepted by patients due to low cost and non-invasiveness. However, in complicated cases, the free-hand technique is time-consuming and technique-sensitive. The presented composite injection technique with a digital workflow significantly simplifies and expedites the composite placement while predictably enhancing the treatment outcome.


Assuntos
Restauração Dentária Permanente , Fluxo de Trabalho , Resinas Compostas , Estética Dentária , Humanos , Incisivo
7.
J Prosthodont Res ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38479888

RESUMO

PATIENTS: This case report presents a minimally invasive approach to replace a missing mandibular lateral incisor using a dual-injection molding technique with flowable composite resins. Integrated with a comprehensive digital workflow, this method achieves a structurally and esthetically biomimetic, bi-layered prosthetic solution. A 34-year-old woman with congenital absence of a mandibular lateral incisor was successfully rehabilitated using a direct composite resin-bonded fixed partial denture (RBFPD). DISCUSSION: Two specialized three-dimensional (3D)-printed flexible indices stabilized by a custom-designed 3D-printed rigid holder were employed to ensure the meticulous injection molding of flowable composite resins formulated to emulate the inherent chromatic gradations between dentin and enamel. The inherent flexibility of the indices, combined with the holder, facilitated accurate and seamless adaptation to the complex morphological features of the dental arch, thereby mitigating the challenges commonly associated with rigid 3D-printed resin indices. CONCLUSIONS: The bilayered direct composite RBFPD using 3D printed flexible indices prepared with a full digital workflow has several advantages over other dental prosthetic solutions, including noninvasiveness, cost-effectiveness, biomimetic esthetics, repairability, and shortened treatment times. Although the initial results are promising, further longitudinal studies with larger patient cohorts are required to confirm the long-term efficacy of this approach.

8.
Materials (Basel) ; 16(14)2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37512378

RESUMO

A slight alteration of the enamel surface is inevitable upon debonding of orthodontic brackets, adhesive removal, and finishing/polishing. The aim of this in vitro study was to compare two adhesives and three polishing methods by measuring enamel surface roughness using confocal laser scanning microscopy (CLSM). Brackets were bonded on 42 extracted human premolars using Transbond XT (Transbond group) or Fuji Ortho (Fuji group). After debracketing, adhesives were removed with a tungsten carbide bur, and surfaces were polished using Sof-Lex discs, a rotary brush with a prophylactic paste (Depural), or a prophylactic cup with two polishing pastes (n = 7 in each subgroup). Surface roughness (Sa, Sku, Sq, and Sz) was measured using CLSM and compared before treatment (T1), after debracketing and adhesive removal (T2), and after polishing (T3). The data were statistically analyzed using the Mann-Whitney U and Kruskal-Wallis tests with Bonferroni correction. The time required for adhesive removal was measured and compared using a two-sample t-test. Surface roughness at T2 increased compared to T1, but the difference was significant only for the Fuji group (p < 0.01). The time required to remove Transbond XT (94.1 ± 6.8 s) was significantly higher compared to Fuji (72.1 ± 5.9 s, p < 0.0001). Polishing with Sof-Lex discs resulted in lower surface roughness compared to T1 (p = 0.018). Using Depural and polishing pastes showed no significant difference in surface roughness compared to T1, except for a significant decrease in Sa and Sq for Transbond (p = 0.043) and in Sku for Fuji (p = 0.018) after polishing with Depural. In conclusion, the removal of Transbond took significantly longer, but there were fewer residues of composite resin on the enamel surface. Sof-Lex discs decreased enamel roughness, whereas enamel morphology and roughness were similar to the pre-treatment state after polishing with polishing pastes.

9.
Diagnostics (Basel) ; 13(11)2023 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-37296731

RESUMO

This in vitro study aimed to compare outcomes of dental caries detection using visual inspection classified according to the International Caries Detection and Assessment System (ICDAS) with objective assessments using a well-established laser fluorescence system (Diagnodent pen) and a novel diffuse reflectance spectroscopy (DRS) device. One hundred extracted permanent premolars and molars were utilized, including sound teeth, teeth with non-cavitated caries, or teeth with small cavitated lesions. A total of 300 regions of interest (ROIs) were assessed using each detection method. Visual inspection, being a subjective method, was performed by two independent examiners. The presence and extent of caries were histologically verified according to Downer's criteria, serving as a reference for other detection methods. Histological results revealed 180 sound ROIs and 120 carious ROIs, categorized into three different extents of caries. Overall, there was no significant difference between the detection methods in sensitivity (0.90-0.93) and false negative rate (0.05-0.07). However, DRS exhibited superior performance in specificity (0.98), accuracy (0.95), and false positive rate (0.04) compared to other detection methods. Although the tested DRS prototype device exhibited limited penetration depth, it shows promise as a method, particularly for the detection of incipient caries.

10.
J Adhes Dent ; 25(1): 187-194, 2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37843501

RESUMO

PURPOSE: Resin composites are commonly used in pediatric dentistry, but there is limited evidence on adhesion to primary teeth, especially primary enamel. In this study, three bonding strategies were assessed - one-step self-etch (1-SE), two-step self-etch (2-SE), and three-step etch-and-rinse (3-ER) - by measuring the immediate and aged microshear bond strength (µSBS) to sound primary enamel. MATERIALS AND METHODS: 120 extracted human primary molars with sound buccal surfaces were used for µSBS testing. Six adhesive protocols (two per bonding strategy) were selected and µSBS was measured either after 24 h or 10,000 thermal cycles (n = 10). Confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM) were used to determine failure modes. Furthermore, 18 primary molars were etched using the different adhesive protocols (n = 3) for the measurement of surface roughness (Sa) using CLSM and morphological analysis using SEM. RESULTS: After 24 h, there was no significant difference in µSBS between 1-SE and 2-SE strategies (p = 0.96), but the 2-SE strategy yielded significantly higher µSBS after thermocycling (p < 0.001). The highest µSBS was obtained using the 3-ER strategy regardless of aging (p < 0.001). The 3-ER strategy clearly exposed enamel prisms and resulted in the highest Sa (p < 0.001). In contrast, if SE strategies were used, enamel prisms were barely recognizable, and Sa was not significantly different from baseline (p > 0.95). CONCLUSION: The 3-ER strategy is optimal for bonding to primary enamel. The etching effect of SE strategies is weaker, resulting in lower µSBS. Thermocycling revealed that the bonding durability of the 1-SE strategy is inferior to that of to multi-step strategies.


Assuntos
Colagem Dentária , Cimentos Dentários , Criança , Humanos , Idoso , Cimentos de Resina , Adesivos Dentinários , Colagem Dentária/métodos , Dentina , Teste de Materiais , Esmalte Dentário
11.
Dent Mater J ; 42(3): 343-350, 2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-36709985

RESUMO

The color-matching ability of single-shade composites Omnichroma (OMN) and Omnichroma Flow (OCF) is ensured by structural color, which arises from monodisperse 260 nm spherical fillers. This study evaluated how filler load influences the color adjustment potential of composite restorations to human teeth of various shades. The performance of composites containing the 260 nm spherical fillers -OMN (79 wt%), OCF (71 wt%), and experimental composites R1 (65 wt%), and R2 (60 wt%)- was compared to two conventional A2-shade composites and a transparent composite. Additionally, the translucency parameter, spectral reflectance, and light transmission properties were assessed. Composites with a lower load of the 260 nm spherical fillers exhibited lower light diffusion and lower reflectance in the yellow-to-red range (580-650 nm), which is characteristic for the structural color of OMN and OCF. The best color adjustment was achieved with OCF, presumably due to its high translucency and uniform spectral reflectance.


Assuntos
Resinas Compostas , Humanos , Cor , Teste de Materiais , Resinas Compostas/química
12.
Dent Mater J ; 42(2): 255-265, 2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-36624077

RESUMO

The recently introduced resin composites with a universal shade are claimed to match any tooth color. In this study, it was examined how composite thickness affects the color adjustment of conventional and universal-shade composites to background dentin. Thirty sound human central incisors of various shade were used, and color differences between their intact labial surfaces, exposed dentin surfaces and composite restorations (thickness 1-3 mm) were evaluated. In addition, the translucency, light transmission characteristics, and spectral reflectance of the composites were measured. The results showed that universal-shade composites outperformed conventional composites of A2 shade in the adjustment of hue and chroma (p<0.05) but not in lightness (p>0.05). The color adjustment potential of all composites significantly decreased as their thickness increased (p<0.05). The effect of thickness on Omnichroma and Omnichroma Flow was less marked, presumably because of their higher translucency (p<0.05) and structural coloration which induces light reflectance in the yellow-to-red range.


Assuntos
Resinas Compostas , Dentina , Humanos , Cor , Resinas Compostas/química , Teste de Materiais
13.
J Adhes Dent ; 25(1): 211-218, 2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37843503

RESUMO

PURPOSE: This case report presents a direct composite inverse injection technique using a bi-layer clear mini-index fabricated with a digital workflow to restore extensive posterior occlusal cavities in a 13-year-old patient. MATERIALS AND METHODS: After a root canal treatment in the right mandibular first molar and step-wise excavation of deep caries in the left mandibular first molar, the extensive occlusal restorations were digitally designed using CAD software, upon which digital wax-ups were 3D-printed. Bi-layer clear mini-indices consisting of a hard outer plastic layer and an elastic inner silicone layer were prepared from the 3D-printed cast. The bonding surfaces were deproteinized using a 6% sodium hypochlorite solution, and an antioxidant (Clearfil DC Activator; Kuraray Noritake) was utilized to improve the dentin bonding durability of a 2-step self-etch adhesive (Clearfil SE Bond 2; Kuraray Noritake). Subsequently, a highly filled universal-shade flowable resin composite (RC) was incrementally placed into the cavities. To create the final occlusal morphology, the same RC was inversely injected through the opening of the bi-layer indices. RESULTS: The workflow was feasible, and the occlusal cavities were efficiently restored using the injection technique. Occlusal carving and adjustments of the morphology were not necessary, leading to less chair time. At the 1-year follow-up, the clinical outcome was excellent. CONCLUSION: The injection technique with a bi-layer clear mini-index accurately translated the digital wax-ups into large, final restorations. Precise morphology and shortened chair time enhanced patient satisfaction, but at the expense of multiple visits.


Assuntos
Suscetibilidade à Cárie Dentária , Cimentos Dentários , Humanos , Criança , Adolescente , Cimentos Dentários/química , Resinas Compostas/química , Cimentos de Resina/química , Antioxidantes , Restauração Dentária Permanente , Adesivos Dentinários/química
14.
Dent Mater J ; 42(3): 426-432, 2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37032103

RESUMO

Volumetric shrinkage (VS) of conventional, bulk-fill, and core build-up resin-based composites (RBCs) of various thickness (1-5 mm) was measured using the modified bonded-disk method with confocal laser scanning microscopy. Additionally, the bottom-to-top ratio of Vickers hardness (%VH) was measured. Conventional RBCs exhibited significantly higher VS than bulk-fill and core build-up RBCs (p<0.05). As specimen thickness increased, VS relative to volume (%VS) and difference in VS at each depth (VSdepth) decreased. For conventional RBCs, there was a significant drop in VSdepth between 1 mm and 2 mm (p<0.05), and another drop was observed between 3 mm and 4 mm (p<0.05) where %VH decreased below 90%. For bulk-fill and core build-up RBCs, VSdepth decreased significantly between 2 mm and 3 mm (p<0.05), but %VH exceeded 90% even in 5 mm deep cavities. These results indicated that post-curing contributed to lower shrinkage in deeper layers, and that conventional RBCs were not adequately polymerized at the depth of over 3 mm.


Assuntos
Resinas Compostas , Cárie Dentária , Humanos , Polimerização , Teste de Materiais , Materiais Dentários , Dureza , Propriedades de Superfície , Cura Luminosa de Adesivos Dentários/métodos
15.
Dent Mater J ; 41(5): 724-730, 2022 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-35676046

RESUMO

This study investigated how the double application of adhesives and dentin moisture level influence the microtensile bond strength (µTBS) of universal adhesives containing different hydrophilic monomers to bur-cut dentin. Four universal adhesives (Scotchbond Universal, Clearfil Universal Bond Quick, Prime&Bond Universal, BeautiBond Universal) were applied to wet and dry bur-cut dentin either in one or two layers. The µTBS test was performed after 25,000 thermal cycles, and scanning electron microscopy was used for the analysis of failure mode and interfacial ultrastructure. Double application significantly improved µTBS on wet dentin (p<0.001), but the effect was not significant on dry dentin (p>0.050). Double application also enhanced the formation of resin tags and limited voids within the adhesive layer of BeautiBond Universal. Dentin moisture had a significant effect on µTBS only if the adhesives were applied in a single layer (p=0.007). Except for Prime&Bond Universal, the tested universal adhesives performed better on dry dentin.


Assuntos
Colagem Dentária , Adesivos Dentinários , Adesivos , Cimentos Dentários , Dentina/ultraestrutura , Adesivos Dentinários/química , Teste de Materiais , Cimentos de Resina/química , Resistência à Tração
16.
J Adhes Dent ; 24(1): 223-232, 2022 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-35418011

RESUMO

PURPOSE: To evaluate the effect of a sulfinate agent on the bonding durability of one-step self-etch adhesives (1-SEAs) to smear-layer-covered dentin deproteinized with hypochlorous acid (HOCl). MATERIALS AND METHODS: Human coronal dentin disks with a standardized smear layer were deproteinized with 100 ppm HOCl solution for 0 s (control), 15 s or 30 s. After rinsing with water for 30 s and air drying, half of the specimens were treated with a sulfinate agent (Scotchbond Universal Dual Cure Activator; SDA) prior to the application of a 1-SEA (Bond Force II [Tokuyama Dental] or Clearfil Universal Bond Quick [Kuraray Noritake]). Microtensile bond strength (µTBS) was measured after 24 h or 10,000 thermal cycles (TC). The data were analyzed by three-way ANOVA with Tukey's post-hoc tests and t-tests at the 0.05 significance level. RESULTS: The 24-h µTBS of both adhesives increased statistically significantly with the HOCl pretreatment for 15 s or 30 s (p < 0.05), but it was not statistically significantly affected by the application of SDA (p > 0.05). However, after TC, the groups treated with the combination of HOCl and SDA maintained their µTBS (p > 0.05), as opposed to untreated dentin and dentin treated with either HOCl or SDA, whose µTBS decreased significantly (p < 0.05). CONCLUSION: The application of the sulfinate agent did not statistically significantly affect the immediate bond strength of 1-SEAs, and it could not prevent a significant decrease in the bond strength to untreated dentin after thermocycling. However, the sulfinate agent significantly improved the bonding durability of 1-SEAs to HOCl smear-layer deproteinized dentin.


Assuntos
Colagem Dentária , Camada de Esfregaço , Adesivos , Cimentos Dentários , Dentina , Adesivos Dentinários/química , Humanos , Ácido Hipocloroso , Teste de Materiais , Cimentos de Resina/química , Resistência à Tração
17.
Dent Mater ; 38(8): 1235-1247, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35715250

RESUMO

OBJECTIVES: To evaluate the effect of smear layer deproteinization using hypochlorous acid (HOCl) with/without metal chlorides (SrCl2 and ZnCl2) on the microtensile bond strength (µTBS) of two simplified adhesives to dentin. METHODS: Human dentin surfaces with a standardized smear layer were pretreated using a 105 ppm HOCl solution with/without SrCl2 (0.05 M, 0.1 M, 0.2 M, 0.4 M) or ZnCl2 (0.05 M, 0.1 M, 0.2 M) for 5 s, 15 s, or 30 s. After the deproteinizing solution was washed out with water for 5 s, 15 s, or 30 s, pretreated surfaces were bonded with one-step self-etch adhesive Bond Force II or universal adhesive Clearfil Universal Bond Quick, and µTBS was measured after 24 h. Additionally, the deproteinizing effects of HOCl solutions with/without the metal chlorides were compared by measuring changes in the amide:phosphate ratio using attenuated total reflection Fourier transform infrared spectroscopy. Statistical analysis was performed using multifactor ANOVA, Tukey's post hoc tests and t-tests (p < 0.05). RESULTS: Pretreatment with pure HOCl for 15 s and 30 s significantly decreased the amide:phosphate ratio (p < 0.05), indicating effective deproteinization, but the µTBS of both adhesives increased significantly only if HOCl was washed out for 30 s (p < 0.05). Increasing the concentrations of metal chlorides enabled shortening of the wash-out time down to 5 s while maintaining the improved µTBS (p < 0.05). The deproteinizing effect of HOCl was not significantly altered by the addition of metal chlorides (p > 0.05). SIGNIFICANCE: The effectiveness of smear layer deproteinization using HOCl can be improved by the addition of metal chlorides, as their increasing concentration allowed to shorten the wash-out time from 30 s down to 5 s.


Assuntos
Colagem Dentária , Camada de Esfregaço , Amidas/análise , Amidas/farmacologia , Cloretos/análise , Cloretos/farmacologia , Cimentos Dentários/farmacologia , Dentina/química , Adesivos Dentinários/química , Humanos , Ácido Hipocloroso/análise , Ácido Hipocloroso/farmacologia , Teste de Materiais , Fosfatos/farmacologia , Cimentos de Resina/química , Resistência à Tração
18.
Dent Mater J ; 41(3): 353-362, 2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35082181

RESUMO

This study investigated the influence of application/wash-out times of sodium hypochlorite (NaOCl) and hypochlorous acid (HOCl) on dentin bond strength of one-step self-etch adhesives (1-SEAs). Human coronal dentin discs with a standardized smear layer were pretreated with 6% NaOCl or 100 ppm HOCl for 5 s, 15 s, or 30 s, and washed out with water for 5 s, 15 s or 30 s with or without the application of Clearfil DC Activator (CDA). No pretreatment was used as a control. The discs were bonded with a 1-SEA (Bond Force II or Clearfil Universal Bond Quick) and microtensile bond strength (µTBS) was measured after 24 h. Pretreatment with NaOCl for 15 s and 30 s significantly decreased µTBS (p<0.05), irrespective of wash-out time. The application of CDA recovered µTBS but did not outperform the control group. Conversely, pretreatment with HOCl for 15 s and 30 s followed by 30 s wash-out time significantly increased µTBS of 1-SEAs (p<0.05), regardless of CDA application.


Assuntos
Colagem Dentária , Camada de Esfregaço , Cimentos Dentários , Dentina/química , Adesivos Dentinários/química , Humanos , Ácido Hipocloroso/análise , Teste de Materiais , Cimentos de Resina/química , Resistência à Tração
19.
Materials (Basel) ; 14(19)2021 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-34640263

RESUMO

Polycarbonates are polymers of bisphenol A (BPA), a well-known endocrine disruptor. This study evaluated the release of BPA from polycarbonate crowns that were (1) milled from Temp Premium Flexible (ZPF, Zirkonzahn, Italy) or Tizian Blank Polycarbonate (TBP, Schütz Dental, Germany), or (2) 3D-printed (Makrolon 2805, Covestro, Germany). Commercial prefabricated polycarbonate crowns (3M, USA) and milled poly(methyl methacrylate) (PMMA) crowns (Temp Basic, Zirkonzahn, Italy) were included for comparison. The crowns were stored at 37 °C in artificial saliva (AS) or methanol, which represented the worst-case scenario of BPA release. Extracts were collected after 1 day, 1 week, 1 month and 3 months. BPA concentrations were measured using liquid chromatography-tandem mass spectrometry. The amounts of released BPA were expressed in micrograms per gram of material (µg/g). After 1 day, the highest amounts of BPA were measured from milled polycarbonates, TBP (methanol: 32.2 ± 3.8 µg/g, AS: 7.1 ± 0.9 µg/g) and ZPF (methanol 22.8 ± 7.7 µg/g, AS: 0.3 ± 0.03 µg/g), followed by 3D-printed crowns (methanol: 11.1 ± 2.3 µg/g, AS: 0.1 ± 0.1 µg/g) and prefabricated crowns (methanol: 8.0 ± 1.6 µg/g, AS: 0.07 ± 0.02 µg/g). Between 1 week and 3 months, the average daily release of BPA in methanol and AS decreased below 2 µg/g and 0.6 µg/g, respectively. No BPA was released from PMMA in AS, and the cumulative amount released in methanol was 0.2 ± 0.06 µg/g. In conclusion, polycarbonates could be a relevant source of BPA, but the current tolerable daily intake of BPA (4 µg/kg body weight) should not be exceeded.

20.
Dent Mater J ; 40(3): 599-605, 2021 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-33361663

RESUMO

The effect of 1-week water storage and subsequent 10,000 thermal cycles on light transmission properties (straight-line transmission (G0), diffusion (DF), the amount of transmitted light (AV)), translucency parameter (TP) and refractive index (RI) of four nanofilled flowable composites was examined. The composites included Filtek Supreme Ultra Flowable Restorative (FSU), Estelite Flow Quick (EFQ), Estelite Universal Flow, (EUF), and Clearfil Majesty ES Flow (ESF), all of A3 shade. For composites with lower filler load (FSU, EFQ), water storage increased G0, AV and TP, but subsequent thermocycling decreased them. An opposite tendency was found for DF. Materials with higher filler load (EUF, ESF) were not significantly affected by aging conditions. RI of EFQ and EUF containing bisphenol A polyethoxy methacrylate (Bis-MPEPP) increased significantly after thermocycling. Additionally, morphological changes were observed using scanning electron microscopy which revealed cracks within nanocluster fillers and dislocation of particles in FSU and EFQ after thermocycling.


Assuntos
Refratometria , Água , Resinas Compostas , Materiais Dentários , Luz , Teste de Materiais , Metacrilatos , Microscopia Eletrônica de Varredura , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA