Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(16)2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39205060

RESUMO

Nitrates can cause severe ecological imbalances in aquatic ecosystems, with considerable consequences for human health. Therefore, monitoring this inorganic form of nitrogen is essential for any water quality management structure. This research was conducted to develop a novel Nitrate Portable Measurement System (NPMS) to monitor nitrate concentrations in water samples. NPMS is a reagent-free ultraviolet system developed using low-cost electronic components. Its operation principle is based on the Beer-Lambert law for measuring nitrate concentrations in water samples through light absorption in the spectral range of 295-315 nm. The system is equipped with a ready-to-use ultraviolet sensor, light emission diode (LED), op-amp, microcontroller, liquid crystal display, quartz cuvette, temperature sensor, and battery. All the components are assembled in a 3D-printed enclosure box, which allows a very compact self-contained equipment with high portability, enabling field and near-real-time measurements. The proposed methodology and the developed instrument were used to analyze multiple nitrate standard solutions. The performance was evaluated in comparison to the Nicolet Evolution 300, a classical UV-Vis spectrophotometer. The results demonstrate a strong correlation between the retrieved measurements by both instruments within the investigated spectral band and for concentrations above 5 mg NO3-/L.

2.
Sensors (Basel) ; 23(3)2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36772098

RESUMO

In this work, a newly developed self-contained, portable, and compact iron measurement system (IMS) based on spectroscopy absorption for determination of Fe2+ in water is presented. One of the main goals of the IMS is to operate the device in the field as opposed to instruments commonly used exclusively in the laboratory. In addition, the system has been tuned to quantify iron concentrations in accordance with the values proposed by the regulations for human consumption. The instrument uses the phenanthroline standard method for iron determination in water samples. This device is equipped with an optical sensing system consisting of a light-emitting diode paired with a photodiode to measure absorption radiation through ferroin complex medium. To assess the sensor response, four series of Fe2+ standard samples were prepared with different iron concentrations in various water matrices. Furthermore, a new solid reagent prepared in-house was investigated, which is intended as a "ready-to-use" sample pre-treatment that optimizes work in the field. The IMS showed better analytical performance compared with the state-of-the-art instrument. The sensitivity of the instrument was found to be 2.5 µg Fe2+/L for the measurement range established by the regulations. The linear response of the photodiode was determined for concentrations between 25 and 1000 µg Fe2+/L, making this device suitable for assessing iron in water bodies.

3.
Percept Mot Skills ; 117(2): 457-69, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24611250

RESUMO

The study investigated the association of tennis playing and running with the psychomotor speed of older drivers. Thirty-six active male drivers (M age = 63.2 yr.) participated. A battery of four on-the road driving tests was performed by tennis players, runners, and a control group. Measures of simple and choice reaction time, movement time, and response time were collected under single- and dual-task conditions. A composite driving score was calculated from reaction time measures of all driving tasks to reflect a general drivers' psychomotor speed. Statistically significant differences between groups were found in a braking task; tennis players performed significantly better than controls in simple reaction time and response time. The composite driving score also differed between groups, and tennis players had better results than controls. Regular participation in tennis was related to psychomotor speed of older drivers.


Assuntos
Condução de Veículo , Desempenho Psicomotor/fisiologia , Tempo de Reação/fisiologia , Corrida/fisiologia , Tênis/fisiologia , Idoso , Estudos de Casos e Controles , Humanos , Masculino , Pessoa de Meia-Idade
4.
J Aging Phys Act ; 19(1): 48-61, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21285475

RESUMO

The main aim of this research was to study the effects of a specific exercise program on the speed of behavior of older adults during on-the-road driving. Twenty-six drivers (55-78 yr old) were randomly assigned to either an exercise group or a control group. The exercise program (3 sessions of 60 min/wk for 8 wk) incorporated tasks that induced the participants to respond quickly to challenging situations. On-the-road driving tasks (under single- and dual-task conditions) included measures of simple and choice reaction time, movement time, and response time. Significant positive effects were found at follow-up resulting from participation in the exercise program: Improvements were found for several measures in all driving tasks, and a composite score reflected a better general drivers' speed of behavior. These results show that exercise can enhance speed of behavior in older drivers and should therefore be promoted.


Assuntos
Condução de Veículo , Exercício Físico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tempo de Reação
5.
Appl Opt ; 41(24): 5059-72, 2002 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-12206216

RESUMO

We compare the spectral sky radiance measured by three ground-based optical radiometers during the second Aerosol Characterization Experiment (ACE-2) to estimate the total uncertainty of the radiance in field experimental conditions. The propagation of this uncertainty on the column-integrated aerosol single-scattering albedo omega0 at 868 nm is investigated. The radiance measurements are affected by a systematic gain uncertainty of less than 2% in the visible spectral region and within 6% in the near-IR region. Correcting the measured radiance by a systematic uncertainty reduces the dispersion of the omega0 from 0.07 to 0.03. Besides, the total relative uncertainty of the radiance measurements in field experimental conditions is within 4% at any wavelength. The corresponding uncertainty delta omega0 is 4% for an aerosol optical thickness of 0.2.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA