Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38367008

RESUMO

AIMS: Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. METHODS AND RESULTS: Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15â€…Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. CONCLUSION: Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Taquicardia Ventricular , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Solução Salina/efeitos adversos , Vapor , Estudos Prospectivos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Taquicardia Ventricular/cirurgia , Irrigação Terapêutica/efeitos adversos
2.
Pacing Clin Electrophysiol ; 47(3): 437-439, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-37260106

RESUMO

We report a case of atrial fibrillation (AF) recurrence after pulmonary vein isolation, which patient had AF trigger in the superior vena cava (SVC) near the sinus node (SN). The ultra-high-resolution mapping revealed that SN located within the SVC and the atrial activation from the SN to SVC propagated in both septal and lateral direction, then upward with circumventing the spontaneous conduction block identified just above and lateral SN (upper hemisphere). We successfully isolated SVC including the ectopic origin at the same level as the SN by utilizing the spontaneous conduction block line around the SN without any complication.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veia Cava Superior/cirurgia , Fibrilação Atrial/cirurgia , Nó Sinoatrial , Átrios do Coração , Bloqueio Cardíaco , Veias Pulmonares/cirurgia
3.
Heart Vessels ; 39(7): 616-625, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38526754

RESUMO

Accurate measurement of the pulmonary vein dimension (PVD) is important for determining stenosis and efficacy following pulmonary vein isolation (PVI). Little is known about the quantitative evaluation of the impact of the cardiac cycle on pulmonary vein (PV) morphology before and after PVI. This study aims to investigate variations in the ostial size of the PV during the cardiac cycle before and after PVI and the effect of the cardiac cycle on PV stenosis and reduction rate using cardiac computed tomography (CT). Sixty-eight patients with atrial fibrillation who underwent cardiac CT before and after PVI at our institution between 23 January 2021 and 5 February 2022 were retrospectively analyzed. The maximum and minimum PVD were measured at each segment before and after the PV. Each PV was evaluated according to the PVD reduction rate (ΔPVD), calculated as follows: (1 - post-PVD/pre-PVD) × 100 (%). The average dimension of all PVs at the end-diastolic frame was significantly reduced compared to that at the end-systolic frame before PVI. The average dimensions of the right superior and right inferior PV at the end-diastolic frame were significantly reduced compared with those at the end-systolic frame following PVI. The average reduction rate of dimension-classified stenosis of PVs, except for the left inferior PV at the end-diastolic frame, was significantly reduced compared with that at the end-systolic frame. The cardiac cycle affects PVD assessment, including PV stenosis, after PVI. PVD measurement is recommended to be unified to the end-systolic frame of the cardiac cycle to avoid underestimating PV stenosis before and after PVI, ensuring appropriate management and follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Masculino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Idoso , Estenose de Veia Pulmonar/fisiopatologia , Estenose de Veia Pulmonar/etiologia , Estenose de Veia Pulmonar/diagnóstico , Estenose de Veia Pulmonar/cirurgia , Resultado do Tratamento , Seguimentos , Frequência Cardíaca/fisiologia
4.
Circ J ; 87(12): 1711-1719, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37258224

RESUMO

BACKGROUND: Pulmonary vein stenosis (PVS) after PV isolation (PVI) for atrial fibrillation (AF) is a severe complication that requires angioplasty. This study aimed to compare the reduction of the cross-sectional PV area (PVA) and the incidence of PVS after cryoballoon (CB)-PVI, hot balloon (HB)-PVI, or laser balloon (LB)-PVI.Methods and Results: A total of 320 patients who underwent an initial catheter ablation procedure for AF using a CB, HB, or LB in 2 hospitals were included. They underwent contrast-enhanced multidetector CT before and 3 months after the procedure. In all 4 PVs, the reduction in PVA was more significant in the LB group than in the CB or HB groups, respectively. Moderate (50-75%) and severe (>75%) PVS were observed in 5.3% and 0.5% of the PVs, respectively. Although moderate PVS was more frequently observed in the LB group than in the CB or HB groups (8.2%, 3.8%, and 5.0%; P=0.03), the incidence of severe PVS was similar in the LB, CB, and HB groups (0.3%, 0.5%, and 1.0%; P=0.46). Symptomatic PVS requiring intervention occurred in 1 (0.3%) patient. CONCLUSIONS: Although the reduction in cross-sectional PVA and the incidence of moderate PVS after LB-PVI was more significant than after CB-PVI or HB-PVI, it rarely led to severe PVS. Symptomatic PVS requiring intervention was rare after the balloon ablation of AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Estenose de Veia Pulmonar , Humanos , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/etiologia , Estudos Transversais , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Lasers
5.
Heart Vessels ; 38(3): 413-421, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36194289

RESUMO

The "pre-freezing" technique was a method in which a fully inflated balloon after the start of freezing was pressed against the pulmonary vein (PV) during cryoballoon ablation and has been applied especially in large-size PVs. Of 556 patients who underwent cryoballoon ablation for atrial fibrillation (AF), the pre-freezing technique was applied to 48 patients. The resulting 2:1 propensity score-matched data set included 120 patients. Using the pre-freezing technique, all left-superior PVs, all left-inferior PVs, and 95% of right-superior PVs were successfully isolated. In most right-inferior PVs, complete sealing using the pre-freezing technique was challenging, and this technique was not applied. Procedure time was similar between the two groups. In the pre-freezing group, the percentage of the left atrial posterior wall isolated was larger (47.6 ± 10.3 vs. 42.8 ± 15.7%, P = 0.006), and the postoperative reduction of diaphragmatic compound motor action potentials tended to occur less frequently (2.5 vs. 12.5%, P = 0.07), and the reduction of the cross-sectional LSPV area was smaller (17.5 ± 12.2 vs. 27.2 ± 19.8%, P = 0.03) than the conventional group. The AF-free rate of the two groups was similar between the two groups (P = 0.15). The pre-freezing technique was a simple method that can isolate a wider surface area during cryoballoon PV isolation. While the postoperative AF recurrence was comparable, the postoperative reduction in the cross-sectional PV area was less than that of the conventional method, which may reduce the risk of PV stenosis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Congelamento , Estudos Transversais , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 33(9): 2100-2103, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35842800

RESUMO

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) in patients with tachycardia-bradycardia syndrome (TBS) can be a major therapeutic option to replace permanent pacemaker implantation (PMI). However, the very long-term outcome of more than 15 years in these patients has not been elucidated. METHODS: From 2002 to 2008, 25 consecutive TBS patients (62 ± 7.9 years old, 68% male) with both AF and symptomatic sinus pauses (>3.0 s) were performed radiofrequency AF ablation. These patients were followed for 15 ± 2.7 years. RESULTS: The median longest sinus pause before the ablation procedure was 6.0 s (4.4-8.0). Following 1.6± 0.8 ablation procedures, 18 (72%) patients remained free from AF. Three (12%) patients died due to noncardiovascular causes, and seven (28%) patients underwent PMI due to symptomatic sinus pause after recurrent AF in five patients and progression of sinus node dysfunction in two patients. The median duration from the first AF ablation to PMI was 6.3 years (range: 9 days to 11.0 years). Five and two patients required PMI more than 5 and 10 years after the first ablation procedure, respectively. CONCLUSION: AF ablation prevented PMI in 72% of TBS patients for a 15-year follow-up. However, in consideration of the long duration of PMI, a continuous careful long-term follow-up was warranted.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Bradicardia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Síndrome do Nó Sinusal/terapia , Taquicardia/diagnóstico , Taquicardia/cirurgia , Resultado do Tratamento
7.
Circ J ; 86(8): 1229-1236, 2022 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-35786690

RESUMO

BACKGROUND: Pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is rare; however, it remains a serious complication. PV angioplasty is reportedly an effective therapy; however, a dedicated device for PV angioplasty has not been developed, and the detailed procedural methods remain undetermined. This study describes the symptoms, indications, treatment strategies, and long-term outcomes for PV stenosis after AF ablation.Methods and Results: This study retrospectively analyzed 7 patients with PV stenosis after catheter ablation for AF and who had undergone PV angioplasty at our hospital during 2015-2021. PV stenosis occurred in the left superior (5 patients) and left inferior (2 patients) PV. Six patients had hemoptysis, chest pain, and dyspnea. Seven de novo lesions were treated using balloon angioplasty (BA) (3 patients), a bare metal stent (BMS) (3 patients), and a drug-coated balloon (DCB) (1 patient). The restenosis rate was 42.9% (n=3; 2 patients in the BA group and 1 patient in the DCB group). The repeat treatment rate was 28.6% (2 patients in the BA group). Stenting was performed as repeat treatment. One patient with subsequent repeat restenosis development underwent BA. Ten PV angioplasties were performed; there were no major complications. CONCLUSIONS: Regarding PV angioplasty after ablation therapy for AF, stenting showed superior long-term PV patency than BA alone; therefore, it should be considered as a standard first-line approach.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Estenose de Veia Pulmonar , Angioplastia/efeitos adversos , Angioplastia/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Constrição Patológica/complicações , Humanos , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/etiologia , Estenose de Veia Pulmonar/terapia , Resultado do Tratamento
8.
Heart Vessels ; 37(1): 110-114, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34216250

RESUMO

The temporal changes in ambulatory monitoring findings after cryoballoon (CB) ablation of atrial fibrillation (AF) have not been well elucidated. This study aims to compare the details of ambulatory monitoring after CB and radiofrequency catheter (RFC) ablation for AF. Of 724 consecutive AF patients who underwent initial ablation using a CB or RFC, 508 (254 pairs) were selected using propensity score matching. Ambulatory monitoring was performed at 1, 3, 6, 12, 24 and 36 months after the procedure. After 1, 3 and 6 months, the number of total heart beats (THBs) was larger in the CB group than in the RFC group. It gradually decreased and became significantly similar by 12 months after ablation. THBs significantly increased 1, 3, 6 and 12 months after ablation in both the RFC and CB groups and became statistically similar by 24 months after ablation. The atrial premature contraction burden was higher in the RFC group than in the CB group at 3 months after ablation. THB and APC burden after AF ablation were significantly different between the RF and CB groups. THBs returned to statistically similarity by 2 years after ablation in both groups.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Complexos Atriais Prematuros/diagnóstico , Criocirurgia/efeitos adversos , Frequência Cardíaca , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 30(11): 2310-2318, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31452290

RESUMO

BACKGROUND: The presence of heart failure (HF) has been associated with poorer outcomes in patients undergoing catheter ablation (CA) for atrial fibrillation (AF). However, the effectiveness of CA amongst the subset of patients with tachycardia-induced cardiomyopathy (TIC) remains poorly defined. METHODS AND RESULTS: In a retrospective analysis we compared outcomes of first-time CA for persistent AF in a cohort of patients with previously diagnosed TIC (n = 45; age 58 ± 8 years; 91% male) to those with structurally normal hearts (non-TIC; n = 440; age 55 ± 9 years; 95% male). TIC was defined as an impaired ventricular function (left ventricular ejection function [LVEF] <50%), which was reversed after the treatment of HF. We compared atrial arrhythmias (AAs) recurrence after the CA in the TIC and non-TIC cohorts. In the TIC group, LVEF improved from 35.8% ± 8.1% to 57.5% ± 8.3% after treatment of HF. During 3.3 ± 1.5 years follow-up, AAs-free survival after CA was significantly higher in the TIC group as compared with the non-TIC group (69% vs 42%; P = .001), despite a comparable CA strategy between the two groups. In multivariable analysis, absence of HF with TIC, longer AF duration, and complex fractionated atrial electrogram ablation were independent predictors of arrhythmia recurrence (OR, 1.02; 95% CI, 1.01-1.03; P < .01; OR, 0.40; 95% CI, 0.20-0.79; P < .01 and OR, 2.29; 95%CI; 1.27-4.11; P < .01, respectively). In addition, the outcome after the last procedure was superior in the TIC cohort (89% vs 72%; P = .03) with fewer CA procedures as compared with the non-TIC cohort (1.3 ± 0.5 vs 1.5 ± 0.7; P = .01). CONCLUSIONS: Persistent patients with AF with TIC have a more favorable outcome after the CA as compared with those without.


Assuntos
Fibrilação Atrial/cirurgia , Cardiomiopatias/etiologia , Ablação por Cateter , Potenciais de Ação , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Recidiva , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
10.
Europace ; 21(7): 1039-1047, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30891597

RESUMO

AIMS: The circuit of pulmonary vein-gap re-entrant atrial tachycardia (PV-gap RAT) after atrial fibrillation ablation is sometimes difficult to identify by conventional mapping. We analysed the detailed circuit and electrophysiological features of PV-gap RATs using a novel high-resolution mapping system. METHODS AND RESULTS: This multicentre study investigated 27 (7%) PV-gap RATs in 26 patients among 378 atrial tachycardias (ATs) mapped with Rhythmia™ system in 281 patients. The tachycardia cycle length (TCL) was 258 ± 52 ms with P-wave duration of 116 ± 28 ms. Three types of PV-gap RAT circuits were identified: (A) two gaps in one pulmonary vein (PV) (unilateral circuit) (n = 17); (B) two gaps in the ipsilateral superior and inferior PVs (unilateral circuit) (n = 6); and (C) two gaps in one PV with a large circuit around contralateral PVs (bilateral circuit) (n = 4). Rhythmia™ mapping demonstrated two distinctive entrance and exit gaps of 7.6 ± 2.5 and 7.9 ± 4.1 mm in width, respectively, the local signals of which showed slow conduction (0.14 ± 0.18 and 0.11 ± 0.10m/s) with fragmentation (duration 86 ± 27 and 78 ± 23 ms) and low-voltage (0.17 ± 0.13 and 0.17 ± 0.21 mV). Twenty-two ATs were terminated (mechanical bump in one) and five were changed by the first radiofrequency application at the entrance or exit gap. Moreover, the conduction time inside the PVs (entrance-to-exit) was 138 ± 60 ms (54 ± 22% of TCL); in all cases, this resulted in demonstrating P-wave with an isoelectric line in all leads. CONCLUSION: This is the first report to demonstrate the detailed mechanisms of PV-gap re-entry that showed evident entrance and exit gaps using a high-resolution mapping system. The circuits were variable and Rhythmia™-guided ablation targeting the PV-gap can be curative.


Assuntos
Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Veias Pulmonares/fisiopatologia , Veias Pulmonares/cirurgia , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
Europace ; 20(6): 943-948, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016768

RESUMO

Aims: Establishment of pulmonary vein isolation (PVI) during cryoballoon (CB) ablation is generally confirmed by use of an octapolar inner-lumen mapping catheter (Achieve®). The aim of this study is to evaluate the residual PV potential (PVP) using the conventional circular catheter after CB-PVI. Methods and results: A total of 105 consecutive patients (418 PVs) with paroxysmal AF who underwent the initial CB-PVI were prospectively included in this study. Of those, 305 (73%) PVs with real-time recordings of PVP elimination by Achieve® catheter during successful PVI were included. After isolation of all 4 PVs, PV antral remapping by conventional circular mapping catheter was performed. After CB-PVI, residual PVP was detected in 4.3% (13/305) of PVs (1.2% of left-superior PV, 2.5% of left-inferior PV, none of right-superior PV, and 20% of right-inferior PV). Almost 60% of residual PV potential was located around the bottom portion of the right-inferior PV. In PVs with residual potential, PV trunk was shorter (12.7 ± 5.7 mm vs. 18.7 ± 7.9, P = 0.001), minimal balloon temperature was higher (-46.6 ± 5.9 °C vs. -50.9 ± 8.2, P = 0.02), and balloon warming time was shorter (35.6 ± 17.8 s vs. 50.0 ± 22.8, P = 0.006) than those without. All residual potentials were eliminated by additional touch up ablation. After the initial ablation procedure, 1-year AF-free rate was 79.5%. Conclusion: PV remapping after CB-PVI revealed residual antral PVP in 4.3% of PVs and in 20% of RIPVs in particular. The Achieve® catheter sometimes fails to detect complete PV antral isolation.


Assuntos
Fibrilação Atrial , Cateteres Cardíacos , Criocirurgia , Técnicas Eletrofisiológicas Cardíacas , Cuidados Pós-Operatórios , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/instrumentação , Criocirurgia/métodos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Desenho de Equipamento , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/instrumentação , Cuidados Pós-Operatórios/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Reprodutibilidade dos Testes , Resultado do Tratamento
12.
Heart Vessels ; 33(5): 529-536, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29147788

RESUMO

Cryoballoons (CBs) have proven to be effective for achieving pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Dissociated PV activity (DPVA) after successful radiofrequency PVI is sometimes observed inside the PV and has been found to prove the achievement of electrical disconnection from the left atrium. However, little is known about the incidence or characteristics of DPVA after CB-PVI. The aim of this study was to compare the incidence and characteristics of DPVA in patients undergoing CB and radiofrequency (RF) ablation for AF. Two hundred and ninety-four propensity score-matched patients from 440 consecutive patients who underwent initial catheter ablation for paroxysmal AF were included in the present study (CB-PVI 147, RF-PVI 147). DPVA was more frequently observed after CB-PVI than after RF-PVI (32 vs. 19% of the PVs, P < 0.001), especially in the left superior PV (52 vs. 29%, P < 0.001) and left inferior PV (22 vs. 7%, P < 0.001). The AF-free rate after the initial ablation in the patients with and without DPVA was similar in both the CB (P = 0.23) and RF (P = 0.39) groups. During repeat ablation procedures for recurrent AF, PV reconnection was similarly observed in PVs with and without DPVA during the initial procedure, both in the CB (30 vs. 44%, P = 0.29) and RF (65 vs. 58%, P = 0.41) groups. DPVA was more frequently observed after CB-PVI than after RF-PVI. The presence of DPVA was not related to the ablation outcome or chronic PV reconnection following CB-PVI.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Pontuação de Propensão , Veias Pulmonares/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Sistema de Condução Cardíaco/cirurgia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Resultado do Tratamento
13.
Heart Vessels ; 33(10): 1238-1244, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29637262

RESUMO

Atrial fibrillation (AF) ablation requires transseptal puncture to access the left atrium. Recently, a radiofrequency (RF) needle was developed. The purpose of this study was to compare the incidence of MRI-confirmed acute cerebral embolism (ACE) during AF ablation procedures performed with RF needle versus mechanical needle transseptal puncture. This study consisted of 383 consecutive patients who underwent catheter ablation for AF that required transseptal puncture with mechanical or radiofrequency transseptal needles. Of those, 232 propensity score-matched patients (116 with each needle type) were included in the analysis. All patients had cerebral MRI performed 1 or 2 days after the procedure. Baseline characteristics were similar between the two groups. Total procedure time was significantly shorter in Group RF than Group non-RF (167 ± 50 vs. 181 ± 52 min, P = 0.01). ACE was detected by MRI in 59 (25%) patients. All patients with ACE were asymptomatic. Incidence of ACE was lower in Group RF than Group non-RF (19 vs. 32%, P = 0.02). B-type natriuretic peptide level was higher in the patients with ACE as compared to those without ACE (65.2 ± 68.7 vs. 44.7 ± 55.1 pg/ml, P = 0.02). In multivariable analysis, the use of RF needle and BNP level was related to the incidence of ACE (OR = 0.499, 95% CI 0.270-0.922, P = 0.03 and OR = 1.005, 95% CI 1.000-1.010, P = 0.03). Use of RF needle for transseptal puncture was associated with lower total procedure time and risk of ACE during catheter ablation of AF.


Assuntos
Fibrilação Atrial/cirurgia , Septo Interatrial/cirurgia , Ablação por Cateter/instrumentação , Complicações Intraoperatórias/epidemiologia , Agulhas , Punções/instrumentação , Tromboembolia/epidemiologia , Fibrilação Atrial/diagnóstico , Septo Interatrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Incidência , Complicações Intraoperatórias/prevenção & controle , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Retrospectivos , Tromboembolia/diagnóstico , Tromboembolia/etiologia , Tomografia Computadorizada por Raios X
14.
Heart Vessels ; 33(7): 770-776, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29357093

RESUMO

Atrial fibrillation (AF), especially asymptomatic cases, is often detected by medical checkups. We investigated the outcome of AF ablation in cases detected by medical checkups. We reviewed the data of 735 patients with AF (56 ± 10 years, paroxysmal: 441 patients) who underwent initial catheter ablation. All patients were divided into two groups based on their AF being diagnosed either by a medical checkup (group M) or not (group NM). AF was diagnosed by medical checkups in 263 (36%) patients. In Group M, the age was younger, time from the diagnosis to ablation shorter, left atrium dimension larger, and left ventricular ejection fraction lower than in Group NM. Male gender, persistent AF, and asymptomatic AF were more frequently seen in Group M than in Group NM. A mean of 13 ± 11 months after the initial ablation procedure, AF recurrence was more frequently observed in group M compared to group NM (P = 0.018). While the AF recurrence rate was similar in both groups in persistent AF patients (P = 0.87), it was more frequently observed in Group M than in Group NM in paroxysmal AF patients (P = 0.005). AF diagnosed by medical checkups was often associated with a worse outcome of catheter ablation, especially in paroxysmal AF patients.


Assuntos
Fibrilação Atrial/diagnóstico , Ablação por Cateter , Taquicardia Paroxística/diagnóstico , Angiografia , Fibrilação Atrial/cirurgia , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Paroxística/cirurgia , Resultado do Tratamento
15.
Heart Vessels ; 32(4): 501-505, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28054100

RESUMO

We herein present a case (72 years, male) with total absence of pulmonary veins (PVs) potentials at the beginning of the first procedure for paroxysmal atrial fibrillation (AF), demonstrating dormant conduction between the left atrium and all PVs revealed by adenosine triphosphate provocation with relation to the incidence of AF. He was free from atrial arrhythmias during 1 year follow-up after complete PV isolation with the elimination of multiple transient dormant conductions by circular mapping catheter guide ablation.


Assuntos
Trifosfato de Adenosina/administração & dosagem , Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Idoso , Humanos , Masculino , Veias Pulmonares/fisiopatologia , Resultado do Tratamento
16.
Heart Vessels ; 31(8): 1402-4, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26391679

RESUMO

An 85-year-old female presented to our institution with symptomatic sick sinus syndrome. During pacemaker implantation, an anchoring sleeve in the right ventricular lead was embolized in the left pulmonary artery. Although the anchoring sleeve was radiolucent, digital subtraction angiography revealed an angiographic filling defect in the lower branch of the left pulmonary artery, and a snare catheter enabled the anchoring sleeve to be grasped and extracted.


Assuntos
Remoção de Dispositivo/métodos , Marca-Passo Artificial , Artéria Pulmonar/diagnóstico por imagem , Síndrome do Nó Sinusal/terapia , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos
17.
Heart Vessels ; 31(2): 261-4, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25213428

RESUMO

A 57-year-old male with persistent atrial fibrillation (AF) was referred for catheter ablation. Multidetector computed tomography (MDCT) revealed that a membrane divided the left atrium into two chambers, thus indicating the presence of cor triatriatum sinister. A 3D image reconstructed by MDCT showed that the accessory atrium received the left common and the right side PVs, as if it were a total common trunk, and this then flowed into the main atrium. After isolation of the pulmonary vein and posterior wall from the left atrium, AF could not be induced by any programmed pacing. The patient has remained free from AF during the 1 year of follow-up.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Coração Triatriado/complicações , Veias Pulmonares/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial , Coração Triatriado/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Flebografia , Veias Pulmonares/anormalidades , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Resultado do Tratamento
18.
Heart Vessels ; 31(2): 256-60, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25223535

RESUMO

A 40-year-old female presented at our hospital because of heart palpitations. During an electrophysiological study, atrioventricular (AV) conduction showed dual AV nodal physiology. Three types of supraventricular tachycardia (SVT) were induced. The initiation of SVT was reproducibility dependent on a critical A-H interval prolongation. An early premature atrial contraction during SVT repeatedly advanced the immediate His potential with termination of the tachycardia, indicating AV node reentrant tachycardia (AVNRT). However, after atrial overdrive pacing during SVT without termination of the tachycardia, the first return electrogram resulted in an AHHA response, consistent with junctional tachycardia. The mechanism of paradoxical responses to pacing maneuvers differentiating AVNRT and junctional tachycardia was discussed.


Assuntos
Estimulação Cardíaca Artificial , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia Ectópica de Junção/diagnóstico , Potenciais de Ação , Adulto , Ablação por Cateter , Diagnóstico Diferencial , Eletrocardiografia , Feminino , Sistema de Condução Cardíaco/cirurgia , Frequência Cardíaca , Humanos , Valor Preditivo dos Testes , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Ectópica de Junção/fisiopatologia , Taquicardia Ectópica de Junção/cirurgia , Resultado do Tratamento
19.
Heart Vessels ; 31(3): 397-401, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25471944

RESUMO

Warfarin is widely used to perform catheter ablation for atrial fibrillation (AF). Heparin is usually administered during this procedure to prevent thromboembolic events, while protamine is used to reduce the incidence of bleeding complications. The purpose of this study was to investigate the influence of heparin and protamine administration on the effects of warfarin and its safety. The subjects included 226 AF patients (206 males, 54.9 ± 9.1 years, paroxysmal/persistent AF: 118/108) undergoing AF ablation with the discontinuation of warfarin administration over 2 days. Heparin was administered to achieve an activated clotting time (ACT) above 300 s during the procedure. Several parameters of the coagulation status, including the prothrombin time international normalized ratio (PT-INR) and ACT values, measured immediately before and after protamine infusion were compared. The mean value of PT-INR prior to ablation was 1.9 ± 0.6. At the end of the procedure, the mean ACT and PT-INR values were 348.0 ± 52.9 and 2.9 ± 0.7, respectively. Following the infusion of 30 mg of protamine, both the ACT and PT-INR values significantly decreased, to 159.6 ± 31.0 (p < 0.0001) and 1.6 ± 0.3 (p < 0.0001), respectively. No cases of symptomatic cerebral infarction were observed, although femoral hematomas developed in 17 (7.5 %) of the patients without further consequence. The concomitant use of heparin augments the effect of warfarin. Meanwhile, protamine administration immediately reverses both the ACT and PT-INR, indicating the applicability of protamine for AF ablation in patients under the mixed administration of heparin and warfarin.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/terapia , Coagulação Sanguínea/efeitos dos fármacos , Ablação por Cateter , Heparina/administração & dosagem , Varfarina/administração & dosagem , Adulto , Idoso , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Testes de Coagulação Sanguínea , Perda Sanguínea Cirúrgica/prevenção & controle , Ablação por Cateter/efeitos adversos , Esquema de Medicação , Monitoramento de Medicamentos/métodos , Feminino , Heparina/efeitos adversos , Antagonistas de Heparina/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/induzido quimicamente , Hemorragia Pós-Operatória/prevenção & controle , Valor Preditivo dos Testes , Protaminas/administração & dosagem , Fatores de Risco , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Fatores de Tempo , Resultado do Tratamento , Varfarina/efeitos adversos
20.
Heart Vessels ; 31(12): 2014-2024, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26936451

RESUMO

Filling defects of the left atrial appendage (LAA) on multidetector computed tomography (MDCT) are known to occur, not only due to LAA thrombi formation, but also due to the disturbance of blood flow in the LAA of patients with atrial fibrillation (AF). The purpose of this study was to evaluate the impact of the maintenance of sinus rhythm via ablation on the incidence of LAA filling defects on MDCT in patients with AF. A total of 459 consecutive patients were included in the present study. Prior to ablation, MDCT and transesophageal echocardiography (TEE) were performed. AF ablation was performed in patients without LAA thrombi confirmed on TEE. The LAA filling defects were evaluated on MDCT at 3 months after ablation. LAA filling defects were detected on MDCT in 51 patients (11.1 %), among whom the absence of LAA thrombi was confirmed in 42 patients using TEE. The LAA Doppler velocity in patients with LAA filling defects was lower than that of patients without filling defects (0.61 ± 0.19 vs. 0.47 ± 0.21 m/s; P < 0.0001). The sensitivity, specificity and negative predictive value of MDCT in the detection of thrombi were 100, 91 and 100 %, respectively. No LAA filling defects were observed on MDCT at 3 months after ablation in any of the patients, including the patients in whom filling defects were noted prior to the procedure. MDCT is useful for evaluating the presence of LAA thrombi and the blood flow of the LAA. The catheter ablation of AF not only suppresses AF, but also eliminates LAA filling defect on MDCT suggesting the improvement of LAA blood flow.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Tomografia Computadorizada Multidetectores , Trombose/diagnóstico por imagem , Idoso , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Trombose/etiologia , Trombose/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA