Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Clin Ultrasound ; 44(3): 175-81, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26402850

RESUMO

PURPOSE: To evaluate the carotid artery diameter, and wall thickness and stiffness in patients with glomerulopathy and proteinuria without severely reduced kidney function. METHODS: We compared 30 control subjects to 30 patients with glomerular disease, proteinuria, and glomerular filtration rate > 30 ml/min/1.73 m(2) : membranous glomerulonephritis (n = 13), minimal change disease (n = 2), focal and segmental glomerulosclerosis (n = 3), IgA nephropathy (n = 5), lupus nephritis (n = 5), antiphospholipid antibody nephropathy (n = 1), cryoglobulinemic glomerulonephritis (n = 1). The laboratory evaluations included carotid artery diameter, intima-media thickness, and stiffness measurements. RESULTS: Carotid cross-sectional area of intima-media complex was thicker in patients (18.6 ± 1.4 [x ± SEM]) than in controls (14.8 ± 0.6 mm(2) , p = 0.014), as was carotid artery wall stiffness (8.96 ± 0.86 versus 5.65 ± 0.38, [x ± SEM], p < 0.01). This difference remained significant after adjustment for age, sex, and metabolic cardiovascular risk factors: carotid stiffness was 9.19 ± 0.67 (99% confidence interval [CI] 7.40-10.98)] in patients and 4.80 ± 0.75 (99% CI 2.79-7.11) in controls; adjusted mean difference 4.40 (99% CI 1.46-7.34); p <0.001. CONCLUSIONS: This study showed, for the first time, signs of altered structural and elastic properties of the arterial wall in patients with proteinuria and glomerular disease without severely reduced kidney function.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiopatologia , Proteinúria/fisiopatologia , Ultrassonografia/métodos , Espessura Intima-Media Carotídea , Elasticidade , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Nefrose/complicações , Nefrose/diagnóstico por imagem , Nefrose/fisiopatologia , Proteinúria/complicações , Fatores de Risco
2.
Microorganisms ; 12(4)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38674702

RESUMO

Acanthamoeba keratitis (AK) is a rare but potentially sight-threatening corneal infection caused by the Acanthamoeba parasite. This microorganism is found ubiquitously in the environment, often in freshwater, soil, and other sources of moisture. Despite its low incidence, AK presents significant challenges due to delayed diagnosis and the complex nature of therapeutic management. Early recognition is crucial to prevent severe ocular complications, including corneal ulceration and vision loss. Diagnostic modalities and treatment strategies may vary greatly depending on the clinical manifestation and the available tools. With the growing reported cases of Acanthamoeba keratitis, it is essential for the ophthalmic community to thoroughly understand this condition for its effective management and improved outcomes. This review provides a comprehensive overview of AK, encompassing its epidemiology, risk factors, pathophysiology, clinical manifestations, diagnosis, and treatment.

3.
Pharmaceutics ; 15(10)2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37896220

RESUMO

Diabetic macular edema (DME)'s therapeutic approach can frequently be challenging. The purpose of the review is to propose evidence-based recommendations on the employment of intravitreal dexamethasone implants (DEX) when approaching patients suffering from DME. Seven national consensuses redacted by different groups of retina specialists from Europe and Asia were examined and confronted. Each consensus was redacted utilizing a Delphi approach, in person meetings, or by reviewing the literature. DEX can be studied as a first-line strategy in individuals suffering from DME with inflammatory OCT biomarkers, in vitrectomized eyes, in patients with recent cardiovascular events, in pregnant women, in patients scheduled to undergo cataract surgery or with poor compliance. The other parameters considered were the indications to the DME treatment, when to switch to DEX, the definition of non-responder to anti-VEGFs agents and to the DEX implant, whether to combine DEX with laser photocoagulation, the association between glaucoma and DEX, and the management of DEX and the cataract. Although several years have passed since the introduction of DEX implants in the DME treatment, there is still not a unified agreement among retina specialists. This paper compares the approach in the DME treatment between countries from different continents and provides a broader and worldwide perspective of the topic.

4.
J Glaucoma ; 31(6): 406-412, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35394466

RESUMO

PRCIS: All devices evaluated in this study showed a significant underestimation in intraocular pressure (IOP) measurement after myopic photorefractive keratectomy (PRK), Goldmann tonometer more than others. Corneal biomechanics indicated a different influence on the different kinds of tonometry. PURPOSE: The aim was to investigate the reliability of Goldmann applanation tonometry (GAT), rebound tonometry (RT), ocular response analyzer (ORA), Corvis ST (CST), and dynamic contour tonometry (DCT) in IOP evaluation after myopic PRK. MATERIALS AND METHODS: One eye of 145 patients who underwent myopic PRK for a refractive defect ranging from -10.25 to -0.50 D (mean -4.69±2.00 D) was included in this retrospective comparative study. A complete eye visit with corneal tomography and IOP measurement with GAT, DCT, ORA, RT, and CST was performed before surgery and at 1, 3, and 6 months follow-up. Values provided by each device were tested and compared at each follow-up. Correlation analyses were run between changes in IOP and the corneal, morphologic and biomechanical parameters were measured after PRK. RESULTS: GAT, DCT, ORA, RT, and CST showed a significant (P<0.01) underestimation of IOP at 6 months follow-up. GAT showed the greatest underestimation (-14.1%) and stronger correlations with corneal deformation parameter changes, whereas ORA, DCT, and RT appeared to be less conditioned by these variations. At 6 months follow-up DCT, ORA, RT, and CST provided IOP values with nonsignificant differences compared with GAT before PRK. CONCLUSIONS: Each tested tonometer showed a significant IOP underestimation after myopic PRK. As this was most observed with GAT compared with all devices, we suggest DCT, ORA, RT, or CST to evaluate IOP in these patients following surgery.


Assuntos
Miopia , Ceratectomia Fotorrefrativa , Córnea/anatomia & histologia , Humanos , Pressão Intraocular , Miopia/cirurgia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tonometria Ocular
5.
J Clin Med ; 10(22)2021 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-34830681

RESUMO

BACKGROUND: Artificial intelligence (AI) is becoming ever more frequently applied in medicine and, consequently, also in ophthalmology to improve both the quality of work for physicians and the quality of care for patients. The aim of this study is to use AI, in particular classification tree, for the evaluation of both ocular and systemic features involved in the onset of complications due to cataract surgery in a teaching hospital. METHODS: The charts of 1392 eyes of 1392 patients, with a mean age of 71.3 ± 8.2 years old, were reviewed to collect the ocular and systemic data before, during and after cataract surgery, including post-operative complications. All these data were processed by a classification tree algorithm, producing more than 260 million simulations, aiming to develop a predictive model. RESULTS: Postoperative complications were observed in 168 patients. According to the AI analysis, the pre-operative characteristics involved in the insurgence of complications were: ocular comorbidities, lower visual acuity, higher astigmatism and intra-operative complications. CONCLUSIONS: Artificial intelligence application may be an interesting tool in the physician's hands to develop customized algorithms that can, in advance, define the post-operative complication risk. This may help in improving both the quality and the outcomes of the surgery as well as in preventing patient dissatisfaction.

7.
J Optom ; 8(3): 180-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26105541

RESUMO

PURPOSE: To evaluate long-term keratoconus stability after corneal crosslinking (CXL) with riboflavin. METHODS: In this prospective study, 57 eyes of 55 patients with progressive keratoconus, consecutively treated with ultraviolet A (UVA) - riboflavin CXL, were examined with the corneal topographer Pentacam, the biometer IOLMaster and the analyzer of corneal biomechanics Ocular Response Analyzer before and during a 24 months follow-up after CXL. RESULTS: Twenty-four months after CXL, there was a significant improvement in best corrected visual acuity (BCVA) (P<0.01), a significant decrease in corneal thinnest point (CTP), keratometry readings at the keratoconus apex (K max), and corneal volume (CV) (P<0.01), and a significant increase in axial eye length (AL) (P=0.01). No significant changes in anterior chamber volume (ACV) and depth (ACD), (P=0.8), corneal hysteresis (CH) (P=0.16) and corneal resistance factor (CRF) (P=0.06) were found. However, in the subgroup of patients with decreased K max readings 24 months after treatment, both CH and CRF showed a significant reduction (P<0.01). CONCLUSION: In the first month after the procedure, CXL induces a reduction in corneal volume. During the 24 months follow-up the cornea tends to recover its original volume with a persistence of the CXL efficacy.


Assuntos
Ceratocone/terapia , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Riboflavina/uso terapêutico , Adolescente , Adulto , Comprimento Axial do Olho , Criança , Colágeno/metabolismo , Córnea/fisiologia , Topografia da Córnea , Reagentes de Ligações Cruzadas/uso terapêutico , Feminino , Humanos , Ceratocone/fisiopatologia , Masculino , Estudos Prospectivos , Acuidade Visual , Adulto Jovem
8.
Cont Lens Anterior Eye ; 37(6): 438-41, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25172670

RESUMO

PURPOSE: To evaluate keratoconus biomechanical changes after transepithelial corneal collagen cross linking (TE CXL) using riboflavin and ultraviolet A (UVA). SETTING: Second University of Naples, Naples, Italy. DESIGN: Prospective non comparative case series study. METHODS: Patients with progressive keratoconus were examined, before and during a 6 months follow up after TE CXL, with a Pentacam, an Ocular Response Analyzer and an IOLMaster. Best corrected visual acuity (BCVA), refraction, corneal thinnest point (CTP), keratometry readings at the keratoconus apex (Kmax), axial eye length (AL), corneal volume (CV) anterior chamber volume (ACV), anterior chamber depth (ACD), corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated. RESULTS: Thirty-six eyes of 36 patients with progressive keratoconus were analyzed. Six months after treatment there was a significant improvement in BCVA (p<0.01), no significant changes in refraction (p=0.57), CTP (p=0.07), Kmax (p=0.88), AL (p=0.07), CV (p=0.38), ACV (p=0.07), ACD (p=0.7), CH (p=0.1) and CRF (p=0.3). CONCLUSIONS: According to our results TE CXL stabilizes most of the patients with progressive keratoconus, without affecting in negative way the corneal elasticity.


Assuntos
Córnea/patologia , Córnea/fisiopatologia , Ceratocone/fisiopatologia , Ceratocone/terapia , Riboflavina/uso terapêutico , Terapia Ultravioleta/métodos , Adolescente , Adulto , Criança , Feminino , Seguimentos , Humanos , Ceratocone/diagnóstico , Masculino , Fármacos Fotossensibilizantes/uso terapêutico , Refração Ocular , Resultado do Tratamento , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA