Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 50(1): 127-135, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30575218

RESUMO

BACKGROUND: Due to the very short T2 of its components, the normal anatomy of Achilles enthesis is impossible to define with "conventional" long echo time (TE) T2 sequences. However, this is a common site affected by rheumatologic disease. Early abnormalities related to inflammatory processes are impossible to detect in this location. PURPOSE: To assess the feasibility of a 3D-UTE (ultrashort echo time) sequence to evaluate normal and pathological Achilles entheses, determining both anterior fibrocartilaginous and posterior collagenic portions at 4.7T, in a rat model of spondyloarthropathy (SpA) with histological correlation. To assess whether this sequence detects SpA enthesopathy prior to long TE T2 sequences, enabling disease monitoring. STUDY TYPE: Prospective case-control study. ANIMAL MODEL: Twelve immunocompetent Wistar male rats imaged before (controls); the model was induced in eight rats (16 tendons) imaged at day 6, day 13, and day 21 with regular sacrifice for ex vivo imaging and histological correlation. FIELD STRENGTH: 4.7T Bruker Biospec Systems. 3D balanced steady-state free precession (bSSFP) and 3D-UTE sequences, performed at baseline (day 0, n = 12 animals / 24 tendons), day 6 (n = 8/16), 13 (n = 4/8), and day 21 (n = 2/4). ASSESSMENT: Visual analysis and signal intensity measurements (signal to noise ratio, SNR) of both bSSFP and UTE images were performed by two independent musculoskeletal radiologists at different locations of the Achilles enthesis and preinsertional area. STATISTICAL TESTS: Normal and pathological rat values were compared by Wilcoxon signed-rank tests, as well as interobserver differences. MRI findings were compared against histological data. RESULTS: The 3D-UTE sequence identified the anterior fibrocartilage and posterior collagenic areas of Achilles entheses in all cases. Visual analysis and signal intensity measurements distinguished SpA-affected entheses from healthy ones at days 6 and 13 (P = 0.002 and P = 0.006, respectively). Neither the normal anatomy of the enthesis nor its pathological pattern could be identified on T2 bSSFP sequences. DATA CONCLUSION: Unlike bSSFP T2 sequences, 3D-UTE sequences enable visualization of normal enthesis anatomy and early detection of abnormalities in pathological conditions. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:127-135.


Assuntos
Tendão do Calcâneo/diagnóstico por imagem , Fibrocartilagem/diagnóstico por imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Espondiloartropatias/diagnóstico por imagem , Animais , Modelos Animais de Doenças , Estudos de Viabilidade , Inflamação , Masculino , Ratos , Ratos Wistar , Tendões/diagnóstico por imagem
2.
Phys Med Biol ; 65(1): 015003, 2020 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-31714255

RESUMO

4D-MRI is a promising tool for organ exploration, target delineation and treatment planning. Intra-scan motion artifacts may be greatly reduced by increasing the imaging frame rate. However, poor signal-to-noise ratios (SNR) are observed when increasing spatial and/or frame number per physiological cycle, in particular in the abdomen. In the current work, the proposed 4D-MRI method favored spatial resolution, frame number, isotropic voxels and large field-of-view (FOV) during MR-acquisition. The consequential SNR penalty in the reconstructed data is addressed retrospectively using an iterative back-projection (IBP) algorithm. Practically, after computing individual spatial 3D deformations present in the images using a deformable image registration (DIR) algorithm, each 3D image is individually enhanced by fusing several successive frames in its local temporal neighborood, these latter being likely to cover common independent informations. A tuning parameter allows one to freely readjust the balance between temporal resolution and precision of the 4D-MRI. The benefit of the method was quantitatively evaluated on the thorax of 6 mice under free breathing using a clinically acceptable duration. Improved 4D cardiac imaging was also shown in the heart of 1 mice. Obtained results are compared to theoretical expectations and discussed. The proposed implementation is easily parallelizable and optimized 4D-MRI could thereby be obtained with a clinically acceptable duration.


Assuntos
Abdome/diagnóstico por imagem , Algoritmos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/normas , Respiração , Razão Sinal-Ruído , Tórax/fisiologia , Animais , Artefatos , Humanos , Imageamento por Ressonância Magnética/métodos , Camundongos , Movimento , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA