Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 33(5): 3156-3164, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36826496

RESUMO

OBJECTIVES: A novel method applying inertial measurement units (IMUs) was developed to assist CT-guided puncture, which enables real-time displays of planned and actual needle trajectories. The method was compared with freehand and laser protractor-assisted methods. METHODS: The phantom study was performed by three operators with 8, 2, and 0 years of experience in CT-guided procedure conducted five consecutive needle placements for three target groups using three methods (freehand, laser protractor-assisted, or IMU-assisted method). The endpoints included mediolateral angle error and caudocranial angle error of the first pass, the procedure time, the total number of needle passes, and the radiation dose. RESULTS: There was a significant difference in the number of needle passes (IMU 1.2 ± 0.42, laser protractor 2.9 ± 1.6, freehand 3.6 ± 2.0 time, p < 0.001), the procedure time (IMU 3.0 ± 1.2, laser protractor 6.4 ± 2.9, freehand 6.2 ± 3.1 min, p < 0.001), the mediolateral angle error of the first pass (IMU 1.4 ± 1.2, laser protractor 1.6 ± 1.3, freehand 3.7 ± 2.5 degree, p < 0.001), the caudocranial angle error of the first pass (IMU 1.2 ± 1.2, laser protractor 5.3 ± 4.7, freehand 3.9 ± 3.1 degree, p < 0.001), and the radiation dose (IMU 250.5 ± 74.1, laser protractor 484.6 ± 260.2, freehand 561.4 ± 339.8 mGy-cm, p < 0.001) among three CT-guided needle insertion methods. CONCLUSION: The wireless IMU improves the angle accuracy and speed of CT-guided needle punctures as compared with laser protractor guidance and freehand techniques. KEY POINTS: • The IMU-assisted method showed a significant decrease in the number of needle passes (IMU 1.2 ± 0.42, laser protractor 2.9 ± 1.6, freehand 3.6 ± 2.0 time, p < 0.001). • The IMU-assisted method showed a significant decrease in the procedure time (IMU 3.0 ± 1.2, laser protractor 6.4 ± 2.9, freehand 6.2 ± 3.1 min, p < 0.001). • The IMU-assisted method showed a significant decrease in the mediolateral angle error of the first pass and the caudocranial angle error of the first pass.


Assuntos
Agulhas , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Punções , Imagens de Fantasmas
2.
Planta Med ; 84(18): 1348-1354, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29986352

RESUMO

Phytochemical investigation of ethanol extracts from two Taiwanese collections of Vernonia cinerea resulted in the isolation of eighteen hirsutinolide-type sesquiterpenoids, including seven new ones designated as vernolides E - K (1: -7: ). All structures were determined by a combination of detailed spectroscopic analyses (NMR and MS) and comparison with reported data. In an in vitro anti-inflammatory assay, compounds 3, 7, 9, 11: , and 14: exhibited strong inhibitory activities toward NO production by LPS-induced RAW264.7 macrophages, with IC50 values of 1.18, 0.85, 0.66, 0.71 and 0.45 µM, respectively, without affecting cellular viability at 40 µM. Preliminary structure-activity relationships indicate that the ester groups at C-8 and C-13 may enhance inhibition of NO production.


Assuntos
Anti-Inflamatórios não Esteroides/farmacologia , Óxido Nítrico/biossíntese , Sesquiterpenos/química , Sesquiterpenos/farmacologia , Vernonia/química , Animais , Anti-Inflamatórios não Esteroides/química , Avaliação Pré-Clínica de Medicamentos/métodos , Concentração Inibidora 50 , Lipopolissacarídeos/farmacologia , Espectroscopia de Ressonância Magnética , Camundongos , Estrutura Molecular , Células RAW 264.7 , Espectrometria de Massas por Ionização por Electrospray , Relação Estrutura-Atividade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA