Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Am J Respir Crit Care Med ; 198(5): 610-619, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29883204

RESUMO

RATIONALE: IL-13 is an important cytokine implicated in the pathogenesis of allergic asthma and is an attractive target for an inhaled therapeutic. OBJECTIVE: To investigate the efficacy of CDP7766, a nebulized inhaled anti-IL-13 monoclonal antibody Fab fragment, in a model of allergic asthma in cynomolgus macaques naturally sensitized to Ascaris suum. METHODS: CDP7766 was nebulized using a vibrating-membrane nebulizer on the basis of eFlow technology. The aerosol generated was analyzed to determine the particle size profile and the biophysical and functional properties of CDP7766. Nebulized CDP7766 (0.1-60 mg/animal, once daily for 5 d) was delivered via the inhaled route. MEASUREMENTS AND MAIN RESULTS: The investigational eFlow nebulizer used in this study generated a respirable aerosol of CDP7766 with no evidence of degradation, loss of potency, aggregation, or formation of particulates. Inhaled CDP7766 was well tolerated in the model (no adverse effects related to local irritation) and significantly inhibited BAL allergen-induced cytokine and chemokine upregulation (60 mg vs. vehicle: eotaxin-3, P < 0.0008; MIP [macrophage inflammatory protein]-1ß, IL-8, IFN-γ, P ≤ 0.01). CDP7766 significantly inhibited the increase in pulmonary resistance stimulated by inhaled allergen, measured 15 minutes and 24 hours after allergen challenge. CONCLUSION: Inhaled CDP7766 potently inhibited the function of IL-13 generated during the airway response to inhaled allergen in cynomolgus macaques, demonstrating the potential of inhaled anti-IL-13 therapeutics for the treatment of allergic asthma.


Assuntos
Antiasmáticos/uso terapêutico , Asma/tratamento farmacológico , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Administração por Inalação , Animais , Antiasmáticos/administração & dosagem , Antiasmáticos/imunologia , Doença Crônica , Modelos Animais de Doenças , Feminino , Fragmentos Fab das Imunoglobulinas/administração & dosagem , Fragmentos Fab das Imunoglobulinas/imunologia , Interleucina-13/imunologia , Macaca fascicularis , Masculino , Resultado do Tratamento
2.
Pediatr Res ; 78(6): 664-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26322413

RESUMO

BACKGROUND: Surfactant replacement therapy is the gold standard treatment of neonatal respiratory distress (RDS). Nebulization is a noninvasive mode of surfactant administration. We administered Poractant alfa (Curosurf) via a vibrating perforated membrane nebulizer (eFlow Neonatal Nebulizer) to spontaneously breathing preterm lambs during binasal continuous positive pressure ventilation (CPAP). METHODS: Sixteen preterm lambs were operatively delivered at a gestational age of 133 ± 1 d (term ~150 d), and connected to CPAP applied via customized nasal prongs. Nebulization was performed (i) with saline or (ii) with surfactant for 3 h in humidified or (iii) nonhumidified air, and with surfactant (iv) for 60 min or (v) for 30 min. We measured arterial oxygenation, lung gas volumes and surfactant pool size and deposition. RESULTS: Nebulization of surfactant in humidified air for 3 h improved oxygenation and lung function, and surfactant was preferentially distributed to the lower lung lobes. Shorter nebulization times and 3 h nebulization in dry air did not show these effects. Nebulized surfactant reached all lung lobes, however the increase of surfactant pool size missed statistical significance. CONCLUSION: Positive effects of surfactant nebulization to spontaneously breathing preterm lambs depend on treatment duration, surfactant dose, air humidity, and surfactant distribution within the lung.


Assuntos
Produtos Biológicos/administração & dosagem , Pressão Positiva Contínua nas Vias Aéreas , Pulmão/efeitos dos fármacos , Membranas Artificiais , Nebulizadores e Vaporizadores , Fosfolipídeos/administração & dosagem , Nascimento Prematuro , Surfactantes Pulmonares/administração & dosagem , Respiração/efeitos dos fármacos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Administração por Inalação , Animais , Animais Recém-Nascidos , Modelos Animais de Doenças , Desenho de Equipamento , Idade Gestacional , Pulmão/fisiopatologia , Síndrome do Desconforto Respiratório do Recém-Nascido/fisiopatologia , Ovinos , Fatores de Tempo , Vibração
3.
J Aerosol Med ; 20(3): 320-30, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17894538

RESUMO

In quantifying aerosol delivery, the drug is often mixed with a radiolabel such as (99m)Tc-DTPA whose deposition is used as a proxy for the drug. (99m)Tc-DTPA deposited in the lung is cleared by a combination of absorption into the pulmonary circulation and mucociliary clearance. If administration is not instantaneous, the image will not include that clearance during administration, a problem raised if comparing devices with different administration times. However, if rates of clearance are measured, it will be possible to "correct" the initial image for the clearance that occurred during administration and before counting. Five adult males inhaled a 5-mL solution containing (99m)Tc-DTPA from a breath enhanced jet nebulizer (LC Plus)over the course of 10 min and a 1.25-mL solution from a vibrating membrane device (eFlow), which was delivered in 2.5 min. Quality assurance was the radioactivity count balance (RCB) defined as the difference in the total radioactivity pre-nebulization less post, divided by pre, and expressed as a percentage. Attenuation calculations used a (57)Co flood source (Macey and Marshall). The "correction" for the clearance of (99m)Tc-DTPA was 0.91 +/- 0.04 (mean +/- SD) for the LC Plus) and 0.96 +/- 0.02 for the eFlow). RCB was -0.6 +/- 3.5% for the LC Plus and -4.7 +/- 6.4% for the eFlow, implying acceptable accuracy. For the LC Plus, lung deposition was 15.9(13.4, 18.4)% (mean and 95% CI) of the charge dose, and for the eFlow it was 32.0(29.0, 35.0)%. This technique gave an acceptable level of accuracy for quantitative planar imaging and allowed the comparison of delivery from devices with very different rates of delivery.


Assuntos
Antibacterianos/administração & dosagem , Sistemas de Liberação de Medicamentos/instrumentação , Pulmão/diagnóstico por imagem , Nebulizadores e Vaporizadores , Compostos Radiofarmacêuticos/administração & dosagem , Pentetato de Tecnécio Tc 99m/administração & dosagem , Tecnologia Farmacêutica/métodos , Tobramicina/administração & dosagem , Administração por Inalação , Adulto , Aerossóis , Desenho de Equipamento , Humanos , Interpretação de Imagem Assistida por Computador , Pulmão/metabolismo , Masculino , Cintilografia , Fatores de Tempo , Tobramicina/metabolismo , Vibração
4.
J Aerosol Med Pulm Drug Deliv ; 27(6): 441-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24383962

RESUMO

BACKGROUND: This clinical trial evaluated the pharmacokinetics and safety/tolerability of amikacin/fosfomycin solution using a vibrating plate nebulizer, in mechanically ventilated patients with ventilator-associated tracheobronchitis (VAT) or ventilator-associated pneumonia (VAP). METHODS: Nine adult patients were consented to receive three escalating doses of a combination of 50 mg/mL amikacin and 20 mg/mL fosfomycin; doses were separated by 24±2 hr. On day 3, patients received two blinded, randomized treatments (amikacin/fosfomycin and volume-matched placebo), separated by 2 hr. All treatments were administered with a single-patient, multitreatment nebulizer (Investigational eFlow(®) Inline Nebulizer System; PARI Pharma GmbH, positioned in the inspiratory limb tubing between the ventilator and the patient. The nebulizer remained in-line until all treatments had been delivered. Concentrations of amikacin and fosfomycin were measured in tracheal aspirate and plasma samples obtained during the 24 hr after each dose. RESULTS: Fifteen minutes after dosing with the 300/120 mg amikacin/fosfomycin combination, tracheal aspirate amikacin concentrations±SD were 12,390±3,986 µg/g, and fosfomycin concentrations were 6,174±2,548 µg/g (n=6). Airway clearance was rapid. Plasma concentrations were subtherapeutic; the highest observed amikacin plasma concentration was 1.4 µg/mL, and the highest observed fosfomycin plasma concentration was 0.8 µg/mL. Administration time was approximately 2 min/mL. No adverse effects on respiratory rate, peak airway pressures, or oxygenation were observed during or following drug or placebo administration. CONCLUSIONS: High tracheal aspirate concentrations of amikacin and fosfomycin were achieved in mechanically ventilated patients with VAT or VAP after aerosolized administration with an inline nebulizer system. Airway clearance was rapid. No adverse respiratory effects were noted during or following drug administration.


Assuntos
Amicacina/administração & dosagem , Antibacterianos/administração & dosagem , Bronquite/tratamento farmacológico , Fosfomicina/administração & dosagem , Nebulizadores e Vaporizadores , Pneumonia Associada à Ventilação Mecânica/tratamento farmacológico , Respiração Artificial/efeitos adversos , Traqueíte/tratamento farmacológico , Administração por Inalação , Adulto , Aerossóis , Idoso , Idoso de 80 Anos ou mais , Amicacina/efeitos adversos , Amicacina/sangue , Amicacina/farmacocinética , Antibacterianos/efeitos adversos , Antibacterianos/sangue , Antibacterianos/farmacocinética , Bronquite/diagnóstico , Bronquite/microbiologia , Método Duplo-Cego , Combinação de Medicamentos , Monitoramento de Medicamentos , Desenho de Equipamento , Fosfomicina/efeitos adversos , Fosfomicina/sangue , Fosfomicina/farmacocinética , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonia Associada à Ventilação Mecânica/diagnóstico , Pneumonia Associada à Ventilação Mecânica/microbiologia , Traqueíte/diagnóstico , Traqueíte/microbiologia , Vitória
5.
J Mol Biol ; 425(3): 577-93, 2013 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-23219467

RESUMO

We describe the discovery, engineering and characterisation of a highly potent anti-human interleukin (IL)-13 Fab fragment designed for administration by inhalation. The lead candidate molecule was generated via a novel antibody discovery process, and the selected IgG variable region genes were successfully humanised and reformatted as a human IgG γ1 Fab fragment. Evaluation of the biophysical properties of a selection of humanised Fab fragments in a number of assays allowed us to select the molecule with the optimal stability profile. The resulting lead candidate, CA652.g2 Fab, was shown to have comparable activity to the parental IgG molecule in a range of in vitro assays and was highly stable. Following nebulisation using a mesh nebuliser, CA652.g2 Fab retained full binding affinity, functional neutralisation potency and structural integrity. Epitope mapping using solution nuclear magnetic resonance confirmed that the antibody bound to the region of human IL-13 implicated in the interaction with IL-13Rα1 and IL-13Rα2. The work described here resulted in the discovery and design of CA652.g2 human γ1 Fab, a highly stable and potent anti-IL-13 molecule suitable for delivery via inhalation.


Assuntos
Fragmentos Fab das Imunoglobulinas/farmacologia , Fatores Imunológicos/farmacologia , Interleucina-13/antagonistas & inibidores , Administração por Inalação , Mapeamento de Epitopos , Humanos , Fragmentos Fab das Imunoglobulinas/genética , Fragmentos Fab das Imunoglobulinas/isolamento & purificação , Fatores Imunológicos/genética , Fatores Imunológicos/isolamento & purificação
6.
ISRN Pediatr ; 2012: 721295, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22792479

RESUMO

Background. New aerosol drugs for infants may require more efficient delivery systems, including face masks. Maximizing delivery efficiency requires tight-fitting masks with minimal internal mask volumes, which could cause carbon dioxide (CO(2)) retention. An RNA-interference-based antiviral for treatment of respiratory syncytial virus in populations that may include young children is designed for aerosol administration. CO(2) accumulation within inhalation face masks has not been evaluated. Methods. We simulated airflow and CO(2) concentrations accumulating over time within a new facemask designed for infants and young children (PARI SMARTMASK(®) Baby). A one-dimensional model was first examined, followed by 3-dimensional unsteady computational fluid dynamics analyses. Normal infant breathing patterns and respiratory distress were simulated. Results. The maximum average modeled CO(2) concentration within the mask reached steady state (3.2% and 3% for normal and distressed breathing patterns resp.) after approximately the 5th respiratory cycle. After steady state, the mean CO(2) concentration inspired into the nostril was 2.24% and 2.26% for normal and distressed breathing patterns, respectively. Conclusion. The mask is predicted to cause minimal CO(2) retention and rebreathing. Infants with normal and distressed breathing should tolerate the mask intermittently delivering aerosols over brief time frames.

7.
Pediatr Pulmonol ; 43(8): 753-9, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18613006

RESUMO

BACKGROUND: Patients with cystic fibrosis spend as much 30 min a day inhaling tobramycin. Could a new rapid system deposit the equivalent amount of tobramycin faster? METHODS: Six healthy adult males inhaled 5 ml (300 mg) of tobramycin from a breath enhanced nebulizer and either 125 mg (n = 3) or 150 mg (n = 3) from a vibrating membrane system with a large or small aerosol mixing chamber respectively. A radiolabel was added to the solution and shown to "track" with the tobramycin. Imaging was done with a dual headed gamma camera. Because the radiolabel will be cleared by mucociliary action during administration, algorithms were developed to allow the comparison of a slower system to a faster one. RESULTS: Both formulations were well tolerated. The lung deposition was 16.6 +/- 3.2% (mean +/- SD) of the charge dose delivered in 10.9 +/- 1.0 min for the breath enhanced nebulizer versus 32.0 +/- 5.1% delivered in 2.5 +/- 0.4 min from the vibrating membrane system. The absolute pulmonary delivery of tobramycin was 49.9 +/- 9.6 versus 43.9 +/- 4.8 mg for the two systems respectively, differences that were statistically significant (pair t-test) but unlikely to be clinically significant. There was a similar deposition of tobramycin for the 125 and 150 mg dose. CONCLUSIONS: It is possible to deliver an equivalent amount of tobramycin in a shorter period of time with the new vibrating membrane system and a more concentrated formulation. These data will allow the design of a comparison in patients with CF.


Assuntos
Antibacterianos/administração & dosagem , Fibrose Cística/tratamento farmacológico , Fibrose Cística/microbiologia , Infecções por Pseudomonas/tratamento farmacológico , Tobramicina/administração & dosagem , Administração por Inalação , Adulto , Antibacterianos/farmacocinética , Humanos , Masculino , Pessoa de Meia-Idade , Nebulizadores e Vaporizadores , Projetos Piloto , Fatores de Tempo , Tobramicina/farmacocinética , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA