1.
Anesthesiology ; 140(4): 752-764, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38207290

RESUMO

BACKGROUND: Lower fractional inspired oxygen tension (Fio2) during general anesthesia can reduce lung atelectasis. The objectives are to evaluate the effect of two Fio2 (0.4 and 1) during low positive end-expiratory pressure (PEEP) ventilation over lung perfusion distribution, volume, and regional ventilation. These variables were evaluated at two PEEP levels and unilateral lung atelectasis. METHODS: In this exploratory study, 10 healthy female piglets (32.3 ± 3.4 kg) underwent mechanical ventilation in two atelectasis models: (1) bilateral gravitational atelectasis (n = 6), induced by changes in PEEP and Fio2 in three combinations: high PEEP with low Fio2 (Fio2 = 0.4), zero PEEP (PEEP0) with low Fio2 (Fio2 = 0.4), and PEEP0 with high Fio2 (Fio2 = 1); and (2) unilateral atelectasis (n = 6), induced by left bronchial occlusion, with the left lung aerated (Fio2 = 0.21) and low aerated (Fio2 = 1; n = 5 for this step). Measurements were conducted after 10 min in each step, encompassing assessment of respiratory mechanics, oxygenation, and hemodynamics; lung ventilation and perfusion by electrical impedance tomography; and lung aeration and perfusion by computed tomography. RESULTS: During bilateral gravitational atelectasis, PEEP reduction increased atelectasis in dorsal regions, decreased respiratory compliance, and distributed lung ventilation to ventral regions with a parallel shift of perfusion to the same areas. With PEEP0, there were no differences between low and high Fio2 in respiratory compliance (23.9 ± 6.5 ml/cm H2O vs. 21.9 ± 5.0; P = 0.441), regional ventilation, and regional perfusion, despite higher lung collapse (18.6 ± 7.6% vs. 32.7 ± 14.5%; P = 0.045) with high Fio2. During unilateral lung atelectasis, the deaerated lung had a lower shunt (19.3 ± 3.6% vs. 25.3 ± 5.5%; P = 0.045) and lower computed tomography perfusion to the left lung (8.8 ± 1.8% vs. 23.8 ± 7.1%; P = 0.007). CONCLUSIONS: PEEP0 with low Fio2, compared with high Fio2, did not produce significant changes in respiratory system compliance, regional lung ventilation, and perfusion despite significantly lower lung collapse. After left bronchial occlusion, the shrinkage of the parenchyma with Fio2 = 1 enhanced hypoxic pulmonary vasoconstriction, reducing intrapulmonary shunt and perfusion of the nonventilated areas.


Assuntos
Atelectasia Pulmonar , Respiração Artificial , Animais , Feminino , Suínos , Respiração Artificial/métodos , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Atelectasia Pulmonar/diagnóstico por imagem , Atelectasia Pulmonar/terapia , Perfusão , Oxigênio
2.
Sensors (Basel) ; 24(6)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38544216

RESUMO

Radiofrequency (RF) coils for magnetic resonance imaging (MRI) applications serve to generate RF fields to excite the nuclei in the sample (transmit coil) and to pick up the RF signals emitted by the nuclei (receive coil). For the purpose of optimizing the image quality, the performance of RF coils has to be maximized. In particular, the transmit coil has to provide a homogeneous RF magnetic field, while the receive coil has to provide the highest signal-to-noise ratio (SNR). Thus, particular attention must be paid to the coil simulation and design phases, which can be performed with different computer simulation techniques. Being largely used in many sectors of engineering and sciences, machine learning (ML) is a promising method among the different emerging strategies for coil simulation and design. Starting from the applications of ML algorithms in MRI and a short description of the RF coil's performance parameters, this narrative review describes the applications of such techniques for the simulation and design of RF coils for MRI, by including deep learning (DL) and ML-based algorithms for solving electromagnetic problems.

3.
Sci Rep ; 14(1): 5832, 2024 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-38461172

RESUMO

Regional pulmonary perfusion (Q) has been investigated using blood volume (Fb) imaging as an easier-to-measure surrogate. However, it is unclear if changing pulmonary conditions could affect their relationship. We hypothesized that vascular changes in early acute respiratory distress syndrome (ARDS) affect Q and Fb differently. Five sheep were anesthetized and received lung protective mechanical ventilation for 20 h while endotoxin was continuously infused. Using dynamic 18F-FDG and 13NN Positron Emission Tomography (PET), regional Fb and Q were analysed in 30 regions of interest (ROIs) and normalized by tissue content (Fbn and Qn, respectively). After 20 h, the lung injury showed characteristics of early ARDS, including gas exchange and lung mechanics. PET images of Fbn and Qn showed substantial differences between baseline and lung injury. Lung injury caused a significant change in the Fbn-Qn relationship compared to baseline (p < 0.001). The best models at baseline and lung injury were Fbn = 0.32 + 0.690Qn and Fbn = 1.684Qn-0.538Qn2, respectively. Endotoxine-associated early ARDS changed the relationship between Fb and Q, shifting from linear to curvilinear. Effects of endotoxin exposure on the vasoactive blood flow regulation were most likely the key factor for this change limiting the quantitative accuracy of Fb imaging as a surrogate for regional Q.


Assuntos
Lesão Pulmonar , Síndrome do Desconforto Respiratório , Animais , Ovinos , Tomografia Computadorizada por Raios X , Pulmão/diagnóstico por imagem , Pulmão/fisiologia , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Perfusão , Volume Sanguíneo , Endotoxinas/toxicidade
4.
Ann Intensive Care ; 14(1): 85, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38849605

RESUMO

BACKGROUND: Protective ventilation seems crucial during early Acute Respiratory Distress Syndrome (ARDS), but the optimal duration of lung protection remains undefined. High driving pressures (ΔP) and excessive patient ventilatory drive may hinder lung recovery, resulting in self-inflicted lung injury. The hidden nature of the ΔP generated by patient effort complicates the situation further. Our study aimed to assess the feasibility of an extended lung protection strategy that includes a stepwise protocol to control the patient ventilatory drive, assessing its impact on lung recovery. METHODS: We conducted a single-center randomized study on patients with moderate/severe COVID-19-ARDS with low respiratory system compliance (CRS < 0.6 (mL/Kg)/cmH2O). The intervention group received a ventilation strategy guided by Electrical Impedance Tomography aimed at minimizing ΔP and patient ventilatory drive. The control group received the ARDSNet low-PEEP strategy. The primary outcome was the modified lung injury score (mLIS), a composite measure that integrated daily measurements of CRS, along with oxygen requirements, oxygenation, and X-rays up to day 28. The mLIS score was also hierarchically adjusted for survival and extubation rates. RESULTS: The study ended prematurely after three consecutive months without patient enrollment, attributed to the pandemic subsiding. The intention-to-treat analysis included 76 patients, with 37 randomized to the intervention group. The average mLIS score up to 28 days was not different between groups (P = 0.95, primary outcome). However, the intervention group showed a faster improvement in the mLIS (1.4 vs. 7.2 days to reach 63% of maximum improvement; P < 0.001), driven by oxygenation and sustained improvement of X-ray (P = 0.001). The intervention group demonstrated a sustained increase in CRS up to day 28 (P = 0.009) and also experienced a shorter time from randomization to room-air breathing (P = 0.02). Survival at 28 days and time until liberation from the ventilator were not different between groups. CONCLUSIONS: The implementation of an individualized PEEP strategy alongside extended lung protection appears viable. Promising secondary outcomes suggested a faster lung recovery, endorsing further examination of this strategy in a larger trial. Clinical trial registration This trial was registered with ClinicalTrials.gov (number NCT04497454) on August 04, 2020.

5.
J. bras. pneumol ; 40(3): 294-303, May-Jun/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-714686

RESUMO

Objective: Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. Methods: This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Results: Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. Conclusions: The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM. .


Objetivo: O desconforto e a falta de adaptação às interfaces de ventilação não invasiva (VNI) são obstáculos ao sucesso da VNI. A máscara facial total (MFT) é uma interface de VNI considerada muito confortável. No entanto, devido a seu grande volume interno e, consequentemente, ao aumento da reinalação de CO2, a MFT tem orifícios que permitem vazamentos proximais para melhorar a eliminação de CO2. É possível que os ventiladores usados na UTI não compensem esse vazamento adequadamente. Neste estudo, buscamos determinar se ventiladores de UTI com módulo de VNI podem ser usados com MFT com grandes vazamentos. Métodos: Estudo em simulador mecânico conduzido em um laboratório universitário de pesquisa. Oito ventiladores de UTI equipados para realizar VNI e um ventilador específico para VNI foram conectados a uma MFT com grandes vazamentos. Todos foram testados com dois níveis de positive end-expiratory pressure (PEEP, pressão expiratória final positiva) e três níveis de pressão de suporte. As variáveis analisadas foram disparo do ventilador, ciclagem, vazamento total e pressurização. Resultados: Dos oito ventiladores de UTI, quatro não funcionaram (autodisparo ou desligamento inapropriado por detecção incorreta de desconexão), três funcionaram com alguns problemas (valores baixos de PEEP ou grande atraso na ciclagem do ventilador) e apenas um funcionou adequadamente. Conclusões: A maioria dos ventiladores de UTI testados mostrou-se inadequada para VNI com MFT com grandes vazamentos. .


Assuntos
Humanos , Análise de Falha de Equipamento/normas , Máscaras/normas , Ventilação não Invasiva/instrumentação , Ventiladores Mecânicos/normas , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento/métodos , Unidades de Terapia Intensiva , Modelos Biológicos , Máscaras/efeitos adversos , Ventilação não Invasiva/efeitos adversos , Ventiladores Mecânicos/efeitos adversos
6.
J. bras. pneumol ; 39(2): 205-213, mar.-abr. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-673312

RESUMO

OBJETIVO: Avaliar, em um modelo pulmonar simulando um paciente sob ventilação mecânica, a eficiência e a segurança da manobra de hiperinsuflação manual (HM) com o intuito de remover secreção pulmonar. MÉTODOS: Oito fisioterapeutas utilizaram um ressuscitador manual autoinflável para realizar HM com o objetivo de remover secreções, em duas condições: conforme rotineiramente aplicada durante sua prática clínica, e após receberem instruções verbais baseadas em recomendações de especialistas. Três cenários clínicos foram simulados: função pulmonar normal, doença pulmonar restritiva e doença pulmonar obstrutiva. RESULTADOS: Antes da instrução, o uso de duas compressões sequenciais do ressuscitador era comum, e a pressão proximal (Pprox) foi mais alta em relação à obtida após a instrução. Entretanto, a pressão alveolar (Palv) nunca excedeu 42,5 cmH2O (mediana, 16,1; intervalo interquartil [IQ], 11,7-24,5), mesmo com valores de Pprox de até 96,6 cmH2O (mediana, 36,7; IQ, 22,9-49,4). O volume corrente (VC) gerado foi relativamente pequeno (mediana, 640 mL; IQ, 505-735) e o pico de fluxo inspiratório (PFI) geralmente excedeu o pico de fluxo expiratório (PFE): 1,37 L/s (IQ, 0,99-1,90) e 1,01 L/s (IQ, 0,55-1,28), respectivamente. Uma relação PFI/PFE < 0,9 (que teoricamente favorece a migração do muco em direção às vias aéreas centrais) foi obtida em somente 16,7% das manobras. CONCLUSÕES: Nas condições testadas, a HM gerou valores seguros de Palv mesmo com altas Pprox. Entretanto, a HM foi comumente realizada de um modo que não favorecia a remoção de secreção (PFI excedendo PFE) mesmo após a instrução. A relação PFI/PFE desfavorável foi explicada pelas insuflações rápidas e o baixo VC.


OBJECTIVE: To evaluate, in a lung model simulating a mechanically ventilated patient, the efficiency and safety of the manual hyperinflation (MH) maneuver as a means of removing pulmonary secretions. METHODS: Eight respiratory therapists (RTs) were asked to use a self-inflating manual resuscitator on a lung model to perform MH as if to remove secretions, under two conditions: as routinely applied during their clinical practice; and after receiving verbal instructions based on expert recommendations. In both conditions, three clinical scenarios were simulated: normal lung function, restrictive lung disease, and obstructive lung disease. RESULTS: Before instruction, it was common for an RT to compress the resuscitator bag two times, in rapid succession. Proximal pressure (Pprox) was higher before instruction than after. However, alveolar pressure (Palv) never exceeded 42.5 cmH2O (median, 16.1; interquartile range [IQR], 11.7-24.5), despite Pprox values as high as 96.6 cmH2O (median, 36.7; IQR, 22.9-49.4). The tidal volume (VT) generated was relatively low (median, 640 mL; IQR, 505-735), and peak inspiratory flow (PIF) often exceeded peak expiratory flow (PEF), the median values being 1.37 L/s (IQR, 0.99-1.90) and 1.01 L/s (IQR, 0.55-1.28), respectively. A PIF/PEF ratio < 0.9 (which theoretically favors mucus migration toward the central airways) was achieved in only 16.7% of the maneuvers. CONCLUSIONS: Under the conditions tested, MH produced safe Palv levels despite high Pprox. However, the MH maneuver was often performed in a way that did not favor secretion removal (PIF exceeding PEF), even after instruction. The unfavorable PIF/ PEF ratio was attributable to overly rapid inflations and low V T.


Assuntos
Humanos , Pulmão , Doença Pulmonar Obstrutiva Crônica/terapia , Ventilação Pulmonar/fisiologia , Terapia Respiratória/métodos , Análise de Variância , Modelos Biológicos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Terapia Respiratória/educação
7.
J. bras. pneumol ; 39(5): 595-603, Sep-Oct/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-695172

RESUMO

OBJECTIVE: To evaluate the performance of manual resuscitators (MRs) used in Brazil in accordance with international standards. METHODS: Using a respiratory system simulator, four volunteer physiotherapists employed eight MRs (five produced in Brazil and three produced abroad), which were tested for inspiratory and expiratory resistance of the patient valve; functioning of the pressure-limiting valve; and tidal volume (VT) generated when the one-handed and two-handed techniques were used. The tests were performed and analyzed in accordance with the American Society for Testing and Materials (ASTM) F920-93 criteria. RESULTS: Expiratory resistance was greater than 6 cmH2O . L−1 . s−1 in only one MR. The pressure-limiting valve, a feature of five of the MRs, opened at low pressures (< 17 cmH2O), and the maximal pressure was 32.0-55.9 cmH2O. Mean VT varied greatly among the MRs tested. The mean VT values generated with the one-handed technique were lower than the 600 mL recommended by the ASTM. In the situations studied, mean VT was generally lower from the Brazilian-made MRs that had a pressure-limiting valve. CONCLUSIONS: The resistances imposed by the patient valve met the ASTM criteria in all but one of the MRs tested. The pressure-limiting valves of the Brazilian-made MRs usually opened at low pressures, providing lower VT values in the situations studied, especially when the one-handed technique was used, suggesting that both hands should be used and that the pressure-limiting valve should be closed whenever possible. .


OBJETIVO: Avaliar o desempenho de reanimadores manuais (RMs) utilizados no Brasil conforme critérios definidos por uma norma internacional. MÉTODOS: Utilizando um simulador do sistema respiratório, oito RMs manuais (cinco produzidos no Brasil e três importados) foram avaliados em relação a resistência inspiratória e expiratória da válvula para o paciente; funcionamento da válvula limitadora de pressão; e volume corrente (VT) gerado por quatro fisioterapeutas voluntários, utilizando uma ou duas mãos. Para a realização e análise dos testes, foram utilizados critérios sugeridos pela norma da American Society for Testing and Materials (ASTM) F920-93. RESULTADOS: A resistência expiratória foi superior a 6 cmH2O . L−1 . s−1 em apenas um dos RMs testados. A válvula limitadora de pressão, presente em cinco RMs, abriu em baixas pressões (< 17 cmH2O), e a pressão máxima variou de 32,0-55,9 cmH2O. Houve grande variação da média de VT obtido pelos diferentes RMs. Os valores médios de VT utilizando uma mão foram inferiores ao sugerido pela ASTM (600 mL). O VT médio, nas situações estudadas, foi geralmente menor nos RMs nacionais com válvula limitadora de pressão. CONCLUSÕES: As resistências impostas pela válvula do paciente estão de acordo com os critérios da ASTM, com exceção de um RM. As válvulas limitadoras de pressão dos RMs nacionais geralmente abrem em baixas pressões, determinando o fornecimento de um menor VT nas situações estudadas, principalmente com o uso de uma mão, o que sugere que a ventilação deva ser feita com as duas mãos e a válvula limitadora de pressão deva ser fechada sempre que possível. .


Assuntos
Feminino , Humanos , Masculino , Unidades de Terapia Intensiva , Ressuscitação/instrumentação , Ventiladores Mecânicos/estatística & dados numéricos , Brasil , Pesquisa Comparativa da Efetividade/métodos , Simulação por Computador/normas , Variações Dependentes do Observador , Mecânica Respiratória/fisiologia , Volume de Ventilação Pulmonar , Ventiladores Mecânicos/normas
8.
Clinics ; 67(10): 1157-1163, Oct. 2012. tab
Artigo em Inglês | LILACS | ID: lil-653479

RESUMO

OBJECTIVES: The aim of this manuscript is to describe the first year of our experience using extracorporeal membrane oxygenation support. METHODS: Ten patients with severe refractory hypoxemia, two with associated severe cardiovascular failure, were supported using venous-venous extracorporeal membrane oxygenation (eight patients) or veno-arterial extracorporeal membrane oxygenation (two patients). RESULTS: The median age of the patients was 31 yr (range 14-71 yr). Their median simplified acute physiological score three (SAPS3) was 94 (range 84-118), and they had a median expected mortality of 95% (range 87-99%). Community-acquired pneumonia was the most common diagnosis (50%), followed by P. jiroveci pneumonia in two patients with AIDS (20%). Six patients were transferred from other ICUs during extracorporeal membrane oxygenation support, three of whom were transferred between ICUs within the hospital (30%), two by ambulance (20%) and one by helicopter (10%). Only one patient (10%) was anticoagulated with heparin throughout extracorporeal membrane oxygenation support. Eighty percent of patients required continuous venous-venous hemofiltration. Three patients (30%) developed persistent hypoxemia, which was corrected using higher positive end-expiratory pressure, higher inspired oxygen fractions, recruitment maneuvers, and nitric oxide. The median time on extracorporeal membrane oxygenation support was five (range 3-32) days. The median length of the hospital stay was 31 (range 3-97) days. Four patients (40%) survived to 60 days, and they were free from renal replacement therapy and oxygen support. CONCLUSIONS: The use of extracorporeal membrane oxygenation support in severely ill patients is possible in the presence of a structured team. Efforts must be made to recognize the necessity of extracorporeal respiratory support at an early stage and to prompt activation of the extracorporeal membrane oxygenation team.


Assuntos
Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Hipóxia/terapia , Oxigenação por Membrana Extracorpórea/mortalidade , Insuficiência Respiratória/terapia , Brasil/epidemiologia , Oxigenação por Membrana Extracorpórea/métodos , Tempo de Internação , Respiração , Fatores de Tempo , Resultado do Tratamento , Centros de Atenção Terciária/estatística & dados numéricos
9.
Pulmäo RJ ; 20(3): 43-48, 2011. ilus
Artigo em Português | LILACS | ID: lil-619180

RESUMO

A lesão pulmonar induzida por ventilador mecânico (LPIV) é um efeito adverso da ventilação mecânica (VM). O conhecimentoda sua fisiopatologia tem permitido desenhar estratégias ventilatórias protetoras — baixo volume corrente associado àpositive end-expiratory pressure (PEEP, pressão expiratória final positiva) — para prevenir a LPIV em pacientes com síndrome do desconforto respiratório agudo, o que reduziu a mortalidade dessa síndrome. Apresentamos uma sucinta revisão sobre LPIV discutindo novos achados tanto em pulmões doentes quanto em pulmões saudáveis. A melhor compreensão da micromecânica pulmonar tem permitido identificar variáveis que melhor refletem os determinantes da lesão pulmonar: o excesso de tensão e de deformação do parênquima pulmonar. Mesmo em pulmões normais, o uso de volumes correntes habituais (8-10 ml/kg) associado a PEEP baixa pode determinar inflamação pulmonar e lesão pulmonar aguda. Portanto, novos métodos de ajuste individualizado da PEEP têm sido analisados. Meta-análises recentes têm apontado o benefício do uso de PEEP alta para minimizar a LPIV em pacientes com SDRA. O uso de marcadores de tensão e deformação pulmonares pode facilitar o ajuste individualizado de uma VM protetora. A LPIV também pode acontecer em pulmões previamente normais e em pacientes submetidos a suporte ventilatório por curto período, como durante o período intraoperatório.


Assuntos
Humanos , Masculino , Feminino , Atelectasia Pulmonar , Respiração Artificial , Síndrome do Desconforto Respiratório , Pneumopatias , Terapia Respiratória
10.
Rev. bras. ter. intensiva ; 19(3): 399-407, jul.-set. 2007. tab
Artigo em Português | LILACS | ID: lil-470956

RESUMO

JUSTIFICATIVA E OBJETIVOS: Em 2000, foi publicado o II Consenso Brasileiro de Ventilação Mecânica. Desde então, o conhecimento na área da ventilação mecânica avançou rapidamente, com a publicação de inúmeros estudos clínicos que acrescentaram importantes informações para o manuseio de pacientes críticos em ventilação artificial. Além disso, a expansão do conceito de Medicina Baseada em Evidências determinou a hierarquização das recomendações clínicas, segundo o rigor metodológico dos estudos que as embasaram. Essa abordagem explícita vem ampliando a compreensão e a aplicação das recomendações clínicas. Por esses motivos, a AMIB - Associação de Medicina Intensiva Brasileira - e a SBPT - Sociedade Brasileira de Pneumologia e Tisiologia - julgaram conveniente a atualização das recomendações descritas no Consenso anterior. Dentre os tópicos selecionados a Fisioterapia durante a Ventilação Mecânica foi um dos temas propostos. O objetivo foi descrever os pontos mais importantes relacionados à atuação do fisioterapeuta no ambiente da terapia Intensiva com ênfase na ventilação mecânica. MÉTODO: Objetivou-se chegar a um documento suficientemente sintético, que refletisse a melhor evidência disponível na literatura. A revisão bibliográfica baseou-se na busca de estudos através de palavras-chave e em sua gradação conforme níveis de evidência. As palavras-chave utilizadas para a busca foram: mechanical ventilation e physical therapy. RESULTADOS: São apresentadas recomendações quanto aos principais procedimentos fisioterápicos, as técnicas e suas aplicações. CONCLUSÕES: A fisioterapia ocupa hoje papel relevante no ambiente da terapia intensiva, principalmente para os pacientes sob ventilação mecânica invasiva ou não invasiva.


BACKGROUND AND OBJECTIVES: The II Brazilian Consensus Conference on Mechanical Ventilation was published in 2000. Knowledge on the field of mechanical ventilation evolved rapidly since then, with the publication of numerous clinical studies with potential impact on the ventilatory management of critically ill patients. Moreover, the evolving concept of evidence - based medicine determined the grading of clinical recommendations according to the methodological value of the studies on which they are based. This explicit approach has broadened the understanding and adoption of clinical recommendations. For these reasons, AMIB - Associação de Medicina Intensiva Brasileira and SBPT - Sociedade Brasileira de Pneumologia e Tisiologia - decided to update the recommendations of the II Brazilian Consensus. Physical therapy during mechanical ventilation has been one of the updated topics. This objective was described the most important topics on the physical therapy during mechanical ventilation. METHODS: Systematic review of the published literature and gradation of the studies in levels of evidence, using the key words: mechanical ventilation and physical therapy. RESULTS: Recommendations on the most important techniques applied during mechanical ventilation. CONCLUSIONS: Physical therapy has a central role at the Intensive Care environment, mainly in patients submitted to a mechanical ventilatory support invasive or non invasive.


Assuntos
Exercícios Respiratórios , Modalidades de Fisioterapia , Respiração Artificial
12.
Rev. ABP-APAL ; 12(1/4): 25-30, jan.-dez. 1990. tab
Artigo em Português | LILACS | ID: lil-198506

RESUMO

Os autores discutem as diferenças existentes entre mulheres alcoolistas (n=68) e homens alcoolistas (n=68), todos pacientes de um hospital público universitário. Foram pesquisados fatores demográficos e outras características ligadas ao uso do álcool. Verificou-se que os grupos em questäo diferem significativamente quanto à idade de aumento de ingestäo e quanto ao número de tentativas de suicídio, sendo semelhantes quanto às características estudadas. Os autores supöem que uma amostra maior possa confirmar estatísticamente outros dados e apontam a importância dessa linha de pesquisa, dado o aumento da populaçäo alcoolista feminina


Assuntos
Humanos , Masculino , Feminino , Alcoolismo