Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Vasc Interv Radiol ; 31(1): 53-60.e1, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31734075

RESUMO

PURPOSE: To investigate differences in procedure time, radiation exposure, and periprocedural complications associated with advanced inferior vena cava (IVC) filter retrieval compared with standard snare retrieval. MATERIALS AND METHODS: A total of 378 patients underwent standard or advanced IVC filter retrieval over a 5-year period. Technical success, retrieval techniques, fluoroscopy time, radiation dose, and complications were analyzed. All retrieval procedures with techniques other than a "snare-and-sheath" method were categorized as advanced, including failed standard attempts requiring intraprocedural conversion to advanced techniques. RESULTS: A total of 462 filter retrieval attempts were made in 378 patients (57% female). Success rates for standard and advanced retrieval attempts were 86.8% (317 of 365) and 91.8% (89 of 97), respectively. The rate of periprocedural complications was significantly higher in the advanced retrieval group (P = .006). Complication rates for standard and advanced retrievals were 0.6% (2 of 318; all minor) and 5.2% (5 of 97; 3 minor [3.1%] and 2 major [2.1%]), respectively. The 2 major complications during advanced retrievals included filter fracture and embolization. Average fluoroscopy time for advanced retrievals was significantly higher than for standard retrievals (23.1 min vs 4.3 min; P < .001). Average radiation dose for advanced retrievals was also significantly higher than for standard retrievals (557.2 mGy vs 156.9 mGy; P < .001). Use of general anesthesia was also significantly more common in advanced retrievals compared with standard retrievals (6.2% vs 0.9%; P = .002). CONCLUSIONS: Advanced filter retrieval results in a similarly high rate of technical success compared with standard snare retrieval but is associated with greater fluoroscopy time, anesthesia requirements, and radiation exposure.


Assuntos
Remoção de Dispositivo/métodos , Implantação de Prótese/instrumentação , Filtros de Veia Cava , Veia Cava Inferior , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral , Chicago , Remoção de Dispositivo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese/efeitos adversos , Doses de Radiação , Exposição à Radiação , Radiografia Intervencionista , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Veia Cava Inferior/diagnóstico por imagem , Adulto Jovem
2.
J Vasc Interv Radiol ; 30(9): 1432-1437, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31279685

RESUMO

The authors conducted an anonymous survey to assess positive and negative factors that may affect medical students' decisions to pursue a career in interventional radiology (IR). The survey was sent to registrants for the Midwest IR Student Symposium in 2016 and/or 2017, with a response rate of 13%; male and female responses were then compared. Female and male medical students shared similar rankings of factors affecting their decisions about choosing IR as a career, such as concern about lifestyle and excitement about therapeutic applications. Access to female IR mentors and diversification of the currently male-dominated workplace were important, gender-specific concerns.


Assuntos
Atitude do Pessoal de Saúde , Escolha da Profissão , Conhecimentos, Atitudes e Prática em Saúde , Estudantes de Medicina/psicologia , Feminino , Humanos , Masculino , Mentores , Fatores Sexuais , Sexismo , Inquéritos e Questionários , Equilíbrio Trabalho-Vida , Carga de Trabalho
3.
J Clin Ultrasound ; 43(5): 327-34, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25042165

RESUMO

Arteriovenous malformations (AVM) of the uterus can cause life-threatening hemorrhage. Unexplained, heavy vaginal bleeding in a reproductive age woman should raise suspicion for an AVM. Here a 37-year-old woman had increasingly severe vaginal bleeding for 15 days. Serum ß-hCG was elevated. Two-dimensional transvaginal ultrasound suggested retained products of conception. Before dilation and curettage (D&C), color Doppler and three-dimensional (3D) power Doppler demonstrated findings indicative of uterine AVM. A bilateral uterine artery embolization was performed without complications. Three months after uterine artery embolization, 3D power Doppler ultrasonography found complete resolution of the AVM. This case illustrates the importance of assessing both gray-scale and 3D power Doppler, and the ability of postprocedure Doppler to assess resolution.


Assuntos
Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/terapia , Imageamento Tridimensional , Ultrassonografia Doppler , Embolização da Artéria Uterina , Adulto , Feminino , Humanos , Artéria Uterina/diagnóstico por imagem , Artéria Uterina/cirurgia
4.
CVIR Endovasc ; 2(1): 14, 2019 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-32026991

RESUMO

BACKGROUND: Migration of the left hepatic lobe into the potential space following right lobe resection can result in torsion and hepatic venous outflow obstruction with compromised venous return from the IVC. If untreated, significant morbidity and mortality can develop. CASE PRESENTATION: We report a case of a 29-year-old female with Lynch syndrome who underwent right lobe resection for a metastatic hepatic tumor. There was subsequent migration of the liver remnant, torsion of the IVC, and impaired hepatic outflow, successfully treated with thrombectomy and stenting. CONCLUSION: Following right hepatectomy, hepatic venous outflow obstruction should be consdered in the setting of hepatorenal failure and hemodynamic instability. Endovascular stenting is a viable treatment option.

5.
Cardiovasc Intervent Radiol ; 41(2): 239-244, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29038876

RESUMO

PURPOSE: Although recommended placement of IVC filters is with their tips positioned at the level of the renal vein inflow, in practice, adherence is limited due to clinical situation or IVC anatomy. We seek to evaluate the indwelling and retrieval complications of IVC filters based on their specific position within the infrarenal IVC. MATERIALS AND METHODS: Retrospective, single institution study of 333 consecutive infrarenal vena cava filters placed by interventional radiologists in patients with an average age of 62.2 ± 15.7 years was performed between 2013 and 2015. Primary indication was venous thromboembolic disease (n = 320, 96.1%). Filters were classified based on location of the apex below the lowest renal vein inflow on the procedural venogram: less than 1 cm (n = 180, 54.1%), 1-2 cm (n = 96, 28.8%), and greater than 2 cm (n = 57, 17.1%). Denali (n = 171, 51.4%) and Celect (n = 162, 48.6%) filters were evaluated. CT follow-up, indwelling complications, and retrieval data were obtained. RESULTS: Follow-up CT imaging performed for symptomatic indications occurred for 38.3% of filters placed < 1 cm below the lowest renal vein, 27.1% of filters placed 1-2 cm, and 36.8% placed > 2 cm (p = .16). There was no difference in caval strut penetration, penetration of adjacent viscera, time to penetration, filter migration, or tilt (p = .15, .27, .41, .57, .93). No filter fractures occurred. There was no difference in the incidence of breakthrough PE or complex filter retrieval (p = .83, .59). Only one retrieval failure occurred. CONCLUSIONS: This study suggests filter apex location within the infrarenal IVC, including placement > 2 cm below the level of the renal vein inflow, is not associated with differences in indwelling or retrieval complications. LEVEL OF EVIDENCE: Level 3 non-randomized controlled follow-up study.


Assuntos
Remoção de Dispositivo/efeitos adversos , Filtros de Veia Cava/efeitos adversos , Veia Cava Inferior , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia/métodos , Embolia Pulmonar/etiologia , Veias Renais , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Trombose Venosa/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA