Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 508
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 92(2): 543-555, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38688865

RESUMO

PURPOSE: To determine whether intravoxel incoherent motion (IVIM) describes the blood perfusion in muscles better, assuming pseudo diffusion (Bihan Model 1) or ballistic motion (Bihan Model 2). METHODS: IVIM parameters were measured in 18 healthy subjects with three different diffusion gradient time profiles (bipolar with two diffusion times and one with velocity compensation) and 17 b-values (0-600 s/mm2) at rest and after muscle activation. The diffusion coefficient, perfusion fraction, and pseudo-diffusion coefficient were estimated with a segmented fit in the gastrocnemius medialis (GM) and tibialis anterior (TA) muscles. RESULTS: Velocity-compensated gradients resulted in a decreased perfusion fraction (6.9% ± 1.4% vs. 4.4% ± 1.3% in the GM after activation) and pseudo-diffusion coefficient (0.069 ± 0.046 mm2/s vs. 0.014 ± 0.006 in the GM after activation) compared to the bipolar gradients with the longer diffusion encoding time. Increased diffusion coefficients, perfusion fractions, and pseudo-diffusion coefficients were observed in the GM after activation for all gradient profiles. However, the increase was significantly smaller for the velocity-compensated gradients. A diffusion time dependence was found for the pseudo-diffusion coefficient in the activated muscle. CONCLUSION: Velocity-compensated diffusion gradients significantly suppress the IVIM effect in the calf muscle, indicating that the ballistic limit is mostly reached, which is supported by the time dependence of the pseudo-diffusion coefficient.


Assuntos
Imagem de Difusão por Ressonância Magnética , Músculo Esquelético , Humanos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Adulto , Masculino , Feminino , Movimento (Física) , Perna (Membro)/diagnóstico por imagem , Perna (Membro)/irrigação sanguínea , Adulto Jovem , Processamento de Imagem Assistida por Computador/métodos , Algoritmos
2.
Magn Reson Med ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888143

RESUMO

PURPOSE: To investigate the impact of reduced k-space sampling on B 1 + $$ {\mathrm{B}}_1^{+} $$ mapping and the resulting impact on phase shimming and dynamic/universal parallel transmit (pTx) RF pulse design. METHODS: Channel-wise 3D B 1 + $$ {\mathrm{B}}_1^{+} $$ maps were measured at 7 T in 35 and 23 healthy subjects for the heart and prostate region, respectively. With these B 1 + $$ {\mathrm{B}}_1^{+} $$ maps, universal phase shims optimizing homogeneity and B 1 + $$ {\mathrm{B}}_1^{+} $$ efficiency were designed for heart and prostate imaging. In addition, universal 4kT-point pulses were designed for the heart. Subsequently, individual phase shims and individual 4kT-pulses were designed based on B 1 + $$ {\mathrm{B}}_1^{+} $$ maps with different acceleration factors and tested on the original maps. The performance of the pulses was compared by evaluating their coefficients of variation (CoV), B 1 + $$ {\mathrm{B}}_1^{+} $$ efficiencies and specific energy doses (SED). Furthermore, validation measurements were carried out for one heart and one prostate subject. RESULTS: For both organs, the universal phase shims showed significantly higher B 1 + $$ {\mathrm{B}}_1^{+} $$ efficiencies and lower CoVs compared to the vendor provided default shim, but could still be improved with individual phase shims based on accelerated B 1 + $$ {\mathrm{B}}_1^{+} $$ maps (acquisition time = 30 s). In the heart, the universal 4kT-pulse achieved significantly lower CoVs than tailored phase shims. Tailored 4kT-pulses based on accelerated B 1 + $$ {\mathrm{B}}_1^{+} $$ maps resulted in even further reduced CoVs or a 2.5-fold reduction in SED at the same CoVs as the universal 4kT-pulse. CONCLUSION: Accelerated B 1 + $$ {\mathrm{B}}_1^{+} $$ maps can be used for the design of tailored pTx pulses for prostate and cardiac imaging at 7 T, which further improve homogeneity, B 1 + $$ {\mathrm{B}}_1^{+} $$ efficiency, or SED compared to universal pulses.

3.
Eur Radiol ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38345606

RESUMO

OBJECTIVES: The purpose of this study was to assess morphological and quantitative changes of the anterior cruciate ligament (ACL) and cartilage after ACL repair. METHODS: 7T MRI of the knee was acquired in 31 patients 1.5 years after ACL repair and in 13 controls. Proton density-weighted images with fat saturation (PD-fs) were acquired to assess ACL width, signal intensity, elongation, and fraying. T2/T2* mapping was performed for assessment of ACL and cartilage. Segmentation of the ACL, femoral, and tibial cartilage was carried out at 12 ROIs. The outcome evaluation consisted of the Lysholm Knee Score and International Knee Documentation Committee (IKDC) subjective score and clinical examination. RESULTS: ACL showed a normal signal intensity in 96.8% and an increased width in 76.5% after repair. Fraying occurred in 22.6% without having an impact on the clinical outcome (Lysholm score: 90.39 ± 9.75, p = 0.76 compared to controls). T2 analysis of the ACL revealed no difference between patients and controls (p = 0.74). Compared to controls, assessment of the femoral and tibial cartilage showed a significant increase of T2* times in all ROIs, except at the posterolateral femur. Patients presented a good outcome in clinical examination with a Lysholm score of 87.19 ± 14.89 and IKDC of 80.23 ± 16.84. CONCLUSION: T2 mapping results suggest that the tissue composition of the ACL after repair is similar to that of a native ACL after surgery, whereas the ACL exhibits an increased width. Fraying of the ACL can occur without having any impact on functional outcomes. T2* analysis revealed early degradation at the cartilage. CLINICAL RELEVANCE STATEMENT: MRI represents a noninvasive diagnostic tool for the morphological and compositional assessment of the anterior cruciate ligament after repair, whereas knowledge about post-surgical alterations is crucial for adequate imaging interpretation. KEY POINTS: • There has been renewed interest in repairing the anterior cruciate ligament with a proximally torn ligament. • T2 times of the anterior cruciate ligament do not differ between anterior cruciate ligament repair patients and controls. • T2 mapping may serve as a surrogate for the evaluation of the anterior cruciate ligament after repair.

4.
Eur Radiol ; 34(7): 4752-4763, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38099964

RESUMO

OBJECTIVES: To evaluate whether artifacts on contrast-enhanced (CE) breast MRI maximum intensity projections (MIPs) might already be forecast before gadolinium-based contrast agent (GBCA) administration during an ongoing examination by analyzing the unenhanced T1-weighted images acquired before the GBCA injection. MATERIALS AND METHODS: This IRB-approved retrospective analysis consisted of n = 2884 breast CE MRI examinations after intravenous administration of GBCA, acquired with n = 4 different MRI devices at different field strengths (1.5 T/3 T) during clinical routine. CE-derived subtraction MIPs were used to conduct a multi-class multi-reader evaluation of the presence and severity of artifacts with three independent readers. An ensemble classifier (EC) of five DenseNet models was used to predict artifacts for the post-contrast subtraction MIPs, giving as the input source only the pre-contrast T1-weighted sequence. Thus, the acquisition directly preceded the GBCA injection. The area under ROC (AuROC) and diagnostics accuracy scores were used to assess the performance of the neural network in an independent holdout test set (n = 285). RESULTS: After majority voting, potentially significant artifacts were detected in 53.6% (n = 1521) of all breast MRI examinations (age 49.6 ± 12.6 years). In the holdout test set (mean age 49.7 ± 11.8 years), at a specificity level of 89%, the EC could forecast around one-third of artifacts (sensitivity 31%) before GBCA administration, with an AuROC = 0.66. CONCLUSION: This study demonstrates the capability of a neural network to forecast the occurrence of artifacts on CE subtraction data before the GBCA administration. If confirmed in larger studies, this might enable a workflow-blended approach to prevent breast MRI artifacts by implementing in-scan personalized predictive algorithms. CLINICAL RELEVANCE STATEMENT: Some artifacts in contrast-enhanced breast MRI maximum intensity projections might be predictable before gadolinium-based contrast agent injection using a neural network. KEY POINTS: • Potentially significant artifacts can be observed in a relevant proportion of breast MRI subtraction sequences after gadolinium-based contrast agent administration (GBCA). • Forecasting the occurrence of such artifacts in subtraction maximum intensity projections before GBCA administration for individual patients was feasible at 89% specificity, which allowed correctly predicting one in three future artifacts. • Further research is necessary to investigate the clinical value of such smart personalized imaging approaches.


Assuntos
Artefatos , Neoplasias da Mama , Meios de Contraste , Imageamento por Ressonância Magnética , Humanos , Meios de Contraste/administração & dosagem , Feminino , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Neoplasias da Mama/diagnóstico por imagem , Adulto , Mama/diagnóstico por imagem , Gadolínio/administração & dosagem , Idoso , Aumento da Imagem/métodos
5.
MAGMA ; 37(2): 257-272, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38366129

RESUMO

OBJECTIVE: To compensate subject-specific field inhomogeneities and enhance fat pre-saturation with a fast online individual spectral-spatial (SPSP) single-channel pulse design. METHODS: The RF shape is calculated online using subject-specific field maps and a predefined excitation k-space trajectory. Calculation acceleration options are explored to increase clinical viability. Four optimization configurations are compared to a standard Gaussian spectral selective pre-saturation pulse and to a Dixon acquisition using phantom and volunteer (N = 5) data at 1.5 T with a turbo spin echo (TSE) sequence. Measurements and simulations are conducted across various body parts and image orientations. RESULTS: Phantom measurements demonstrate up to a 3.5-fold reduction in residual fat signal compared to Gaussian fat saturation. In vivo evaluations show improvements up to sixfold for dorsal subcutaneous fat in sagittal cervical spine acquisitions. The versatility of the tailored trajectory is confirmed through sagittal foot/ankle, coronal, and transversal cervical spine experiments. Additional measurements indicate that excitation field (B1) information can be disregarded at 1.5 T. Acceleration methods reduce computation time to a few seconds. DISCUSSION: An individual pulse design that primarily compensates for main field (B0) inhomogeneities in fat pre-saturation is successfully implemented within an online "push-button" workflow. Both fat saturation homogeneity and the level of suppression are improved.


Assuntos
Aumento da Imagem , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Frequência Cardíaca , Vértebras Cervicais/diagnóstico por imagem
6.
BMC Geriatr ; 24(1): 141, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38326734

RESUMO

BACKGROUND: Osteosarcopenia is a common geriatric syndrome with an increasing prevalence with age, leading to secondary diseases and complex consequences such as falls and fractures, as well as higher mortality and frailty rates. There is a great need for prevention and treatment strategies. METHODS: In this analysis, we used magnetic resonance imaging (MRI) data from the randomised controlled FrOST trial, which enrolled community-dwelling osteosarcopenic men aged > 72 years randomly allocated to 16 months of twice-weekly high-intensity resistance training (HIRT) or a non-training control group. MR Dixon imaging was used to quantify the effects of HIRT on muscle fat infiltration in the paraspinal muscles, determined as changes in muscle tissue, fat faction and intermuscular adipose tissue (IMAT) in the erector spinae and psoas major muscles. Intention-to-treat analysis with multiple imputation was used to analyse the data set. RESULTS: After 16 months of intervention, 15 men from the HIRT and 16 men from the CG were included in the MRI analysis. In summary, no positive effects on the fat infiltration of the erector spinae and psoas major muscles were observed. CONCLUSIONS: The previously reported positive effects on lumbar spine bone mineral density (BMD) suggest that mechanotransduction induces tropic effects on bone, but that fat infiltration of the erector spinae and psoas major muscles are either irreversible or, for some unknown reason, resistant to exercise. Because of the beneficial effects on spinal BMD, HIRT is still recommended in osteosarcopenic older men, but further research is needed to confirm appropriate age-specific training exercises for the paraspinal muscles. The potential of different MRI sequences to quantify degenerative and metabolic changes in various muscle groups must be better characterized. TRIAL REGISTRATIONS: FrOST was approved by the University Ethics Committee of the Friedrich-Alexander University of Erlangen-Nürnberg (number 67_15b and 4464b) and the Federal Office for Radiation Projection (BfS, number Z 5-2,246,212 - 2017-002). Furthermore, it fully complies with the Declaration of Helsinki and is registered at ClinicalTrials.gov: NCT03453463 (05/03/2018). JAMA 310:2191-2194, 2013.


Assuntos
Mecanotransdução Celular , Músculos Paraespinais , Idoso , Masculino , Humanos , Músculos Paraespinais/diagnóstico por imagem , Músculos Paraespinais/fisiologia , Densidade Óssea , Tecido Adiposo/diagnóstico por imagem , Projetos de Pesquisa , Imageamento por Ressonância Magnética/métodos
7.
Orthod Craniofac Res ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38783751

RESUMO

OBJECTIVES: This study aimed to establish a fully digital measurement protocol for standardizing the description of hard palate and cleft morphology in neonates with an isolated cleft palate (CPO) and Pierre Robin sequence (PRS). MATERIALS AND METHODS: A total of 20 digitized plaster models of neonates with CPO and 20 digitized plaster models of neonates with PRS were retrospectively investigated. For the control group, the hard palate was segmented from 21 pre-existing 1.5 T MRI datasets of neonates and exported as an STL file. The digital models were marked with predefined reference points by three raters. Distance, angular, and area measurements were performed using Blender and MeshLab. RESULTS: Neonates with CPO (20.20 ± 2.33 mm) and PRS (21.41 ± 1.81 mm) had a significantly shorter hard palate than the control group (23.44 ± 2.24 mm) (CPO vs. control: P < .001; PRS vs. control: P = .014). Notably, neonates with PRS (33.05 ± 1.95 mm) demonstrated a significantly wider intertuberosity distance than those with CPO (30.52 ± 2.28 mm) (P = .012). Furthermore, there were also significant differences measured between the cleft and control groups (25.22 ± 2.50 mm) (P < .001). CONCLUSIONS: The data from this study demonstrate the feasibility of using MRI datasets to generate digital models of the hard palate. The presence of a cleft palate leads to pronounced adaptations of the total palatal surface area, dorsal width, and length of the hard palate. Mandibular retrognathia and altered tongue position in PRS, as opposed to CPO, might further impact palatal morphology and intertuberosity distance.

8.
Proc Natl Acad Sci U S A ; 118(28)2021 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-34260395

RESUMO

Novel MRI techniques allow a noninvasive quantification of tissue sodium and reveal the skin as a prominent compartment of sodium storage in health and disease. Since multiple sclerosis (MS) immunopathology is initiated in the periphery and increased sodium concentrations induce proinflammatory immune cells, the skin represents a promising compartment linking high sodium concentrations and MS immunopathology. We used a 7-T sodium MRI (23Na-MRI) and inductively coupled plasma mass spectrometry to investigate the skin sodium content in two mouse models of MS. We additionally performed 3-T 23Na-MRI of calf skin and muscles in 29 male relapsing-remitting MS (RRMS) patients and 29 matched healthy controls. Demographic and clinical information was collected from interviews, and disease activity was assessed by expanded disability status scale scoring. 23Na-MRI and chemical analysis demonstrated a significantly increased sodium content in the skin during experimental autoimmune encephalomyelitis independent of active immunization. In male patients with RRMS, 23Na-MRI demonstrated a higher sodium signal in the area of the skin compared to age- and biological sex-matched healthy controls with higher sodium, predicting future disease activity in cranial MRI. In both studies, the sodium enrichment was specific to the skin, as we found no alterations of sodium signals in the muscle or other tissues. Our data add to the recently identified importance of the skin as a storage compartment of sodium and may further represent an important organ for future investigations on salt as a proinflammatory agent driving autoimmune neuroinflammation such as that in MS.


Assuntos
Esclerose Múltipla/metabolismo , Pele/metabolismo , Sódio/metabolismo , Adulto , Animais , Modelos Animais de Doenças , Humanos , Inflamação/patologia , Imageamento por Ressonância Magnética , Masculino , Camundongos Endogâmicos C57BL , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla Recidivante-Remitente/metabolismo , Processamento de Sinais Assistido por Computador , Pele/diagnóstico por imagem
9.
Skeletal Radiol ; 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381197

RESUMO

This narrative review explores recent advancements and applications of modern low-field (≤ 1 Tesla) magnetic resonance imaging (MRI) in musculoskeletal radiology. Historically, high-field MRI systems (1.5 T and 3 T) have been the standard in clinical practice due to superior image resolution and signal-to-noise ratio. However, recent technological advancements in low-field MRI offer promising avenues for musculoskeletal imaging. General principles of low-field MRI systems are being introduced, highlighting their strengths and limitations compared to high-field counterparts. Emphasis is placed on advancements in hardware design, including novel magnet configurations, gradient systems, and radiofrequency coils, which have improved image quality and reduced susceptibility artifacts particularly in musculoskeletal imaging. Different clinical applications of modern low-field MRI in musculoskeletal radiology are being discussed. The diagnostic performance of low-field MRI in diagnosing various musculoskeletal pathologies, such as ligament and tendon injuries, osteoarthritis, and cartilage lesions, is being presented. Moreover, the discussion encompasses the cost-effectiveness and accessibility of low-field MRI systems, making them viable options for imaging centers with limited resources or specific patient populations. From a scientific standpoint, the amount of available data regarding musculoskeletal imaging at low-field strengths is limited and often several decades old. This review will give an insight to the existing literature and summarize our own experiences with a modern low-field MRI system over the last 3 years. In conclusion, the narrative review highlights the potential clinical utility, challenges, and future directions of modern low-field MRI, offering valuable insights for radiologists and healthcare professionals seeking to leverage these advancements in their practice.

10.
Skeletal Radiol ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38607418

RESUMO

OBJECTIVE: To compare image quality and diagnostic performance of 3T and 7T magnetic resonance imaging (MRI) for direct depiction of finger flexor pulleys A2, A3 and A4 before and after artificial pulley rupture in an ex-vivo model using anatomic preparation as reference. MATERIALS AND METHODS: 30 fingers from 10 human cadavers were examined at 3T and 7T before and after being subjected to iatrogenic pulley rupture. MRI protocols were comparable in duration, both lasting less than 22 min. Two experienced radiologists evaluated the MRIs. Image quality was graded according to a 4-point Likert scale. Anatomic preparation was used as gold standard. RESULTS: In comparison, 7T versus 3T had a sensitivity and specificity for the detection of A2, A3 and A4 pulley lesions with 100% vs. 95%, respectively 98% vs. 100%. In the assessment of A3 pulley lesions sensitivity of 7T was superior to 3T MRI (100% vs. 83%), whereas specificity was lower (95% vs. 100%). Image quality assessed before and after iatrogenic rupture was comparable with 2.74 for 7T and 2.61 for 3T. Visualization of the A3 finger flexor pulley before rupture creation was significantly better for 7 T (p < 0.001). Interobserver variability showed substantial agreement at 3T (κ = 0.80) and almost perfect agreement at 7T (κ = 0.90). CONCLUSION: MRI at 3T allows a comparable diagnostic performance to 7T for direct visualization and characterization of finger flexor pulleys before and after rupture, with superiority of 7T MRI in the visualization of the normal A3 pulley.

11.
Sensors (Basel) ; 24(3)2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38339689

RESUMO

Whole-body electromyostimulation (WB-EMS) can be considered as a time-efficient, joint-friendly, and highly customizable training technology that attracts a wide range of users. The present evidence map aims to provide an overview of different non-athletic cohorts addressed in WB-EMS research. Based on a comprehensive systematic search according to PRISMA, eighty-six eligible longitudinal trials were identified that correspond with our eligibility criteria. In summary, WB-EMS research sufficiently covers all adult age categories in males and females. Most cohorts addressed (58%) were predominately or exclusively overweight/obese, and in about 60% of them, diseases or conditions were inclusion criteria for the trials. Cohorts specifically enrolled in WB-EMS trials suffer from cancer/neoplasm (n = 7), obesity (n = 6), diabetes mellitus (n = 5), metabolic syndrome (n = 2), nervous system diseases (n = 2), chronic heart failure (n = 4), stroke (n = 1), peripheral arterial diseases (n = 2), knee arthrosis (n = 1), sarcopenia (n = 3), chronic unspecific low back pain (n = 4), and osteopenia (n = 3). Chronic kidney disease was an eligibility criterion in five WB-EMS trials. Finally, three studies included only critically ill patients, and two further studies considered frailty as an inclusion criterion. Of importance, no adverse effects of the WB-EMS intervention were reported. In summary, the evidence gaps in WB-EMS research were particular evident for cohorts with diseases of the nervous and cerebrovascular system.


Assuntos
Terapia por Estimulação Elétrica , Dor Lombar , Sarcopenia , Masculino , Adulto , Feminino , Humanos , Músculo Esquelético/fisiologia , Obesidade/terapia
12.
Radiol Med ; 129(2): 268-279, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38017228

RESUMO

OBJECTIVES: To compare a novel, non-contrast, flow-independent, 3D isotropic magnetic resonance angiography (MRA) sequence that combines respiration compensation, electrocardiogram (ECG)-triggering, undersampling, and Dixon water-fat separation with an ECG-triggered aortic high-pitch computed tomography angiography (CTA) of the aorta. MATERIALS AND METHODS: Twenty-five patients with recent CTA were scheduled for non-contrast MRA on a 3 T MRI. Aortic diameters and cross-sectional areas were measured on MRA and CTA using semiautomatic measurement tools at 11 aortic levels. Image quality was assessed independently by two radiologists on predefined aortic levels, including myocardium, proximal aortic branches, pulmonary veins and arteries, and the inferior (IVC) and superior vena cava (SVC). Image quality was assessed on a 5-point Likert scale. RESULTS: All datasets showed diagnostic image quality. Visual grading was similar for MRA and CTA regarding overall image quality (0.71), systemic arterial image quality (p = 0.07-0.91) and pulmonary artery image quality (p = 0.05). Both readers favored MRA for SVC and IVC, while CTA was preferred for pulmonary veins (all p < 0.05). No significant difference was observed in aortic diameters or cross-sectional areas between native MRA and contrast-enhanced CTA (p = 0.08-0.94). CONCLUSION: The proposed non-contrast MRA enables robust imaging of the aorta, its proximal branches and the pulmonary arteries and great veins with image quality and aortic diameters and cross-sectional areas comparable to that of CTA. Moreover, this technique represents a suitable free-breathing alternative, without the use of contrast agents or ionizing radiation. Therefore, it is especially suitable for patients requiring repetitive imaging.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Humanos , Angiografia por Ressonância Magnética/métodos , Veia Cava Superior/diagnóstico por imagem , Artéria Pulmonar
13.
Odontology ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38758257

RESUMO

The maxilla occupies a key position in dentofacial orthopaedics, since its transversal development can be directly influenced by orthodontic therapy. The maturation stages of the mid-palatal suture, which are obtained from cone-beam computed tomography images (CBCT), present an addition to clinical decision-making in transversal discrepancies of the upper jaw. In an endeavour to reduce ionizing radiation in adolescents and young adults, who are particularly susceptible to long term stochastic irradiation effects, we investigated the feasibility of 3 Tesla (3T) MRI in detecting the maturation stages of the mid-palatal suture. A collective of 30 patients aged 24-93 years with routine neck MRI at 3T, underwent an additional three-dimensional isotropic T1 weighted study sequence of the midface. Image evaluation was performed on axial, multi-planar formatted reconstructions of the dataset aligned to the midline axis of the palate, and curved reconstructions aligned to the concavity of the palate. Inverted images helped to achieve an image impression similar to the well-known CBCT appearance. All datasets were reviewed by three readers and mid-palatal maturation was scored twice according to Angelieri et al. Intra- and inter-rater agreement were evaluated to measure the robustness of the images for clinical evaluation. 3T MRI deemed reliable for the assessment of mid-palatal suture maturation and hence for the appraisal of the hard palate and its adjacent sutures. The data of this pilot study display the feasibility of non-ionizing cross-sectional MRI for the determination of sutural maturation stages. These findings underline the potential of MRI for orthodontic treatment planning, further contributing to the avoidance of unnecessary radiation doses.

14.
Radiology ; 307(2): e220753, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36625744

RESUMO

Background Ultrahigh-field-strength MRI at 7 T may permit superior visualization of noninflammatory wrist pathologic conditions, particularly due to its high signal-to-noise ratio compared with the clinical standard of 3 T, but direct comparison studies are lacking. Purpose To compare the subjective image quality of 3-T and 7-T ultrahigh-field-strength wrist MRI through semiquantitative scoring of multiple joint tissues in a multireader study. Materials and Methods In this prospective study, healthy controls and participants with chronic wrist pain underwent 3-T and 7-T MRI (coronal T1-weighted turbo spin-echo [TSE], coronal fat-suppressed proton-density [PD]-weighted TSE, transversal T2-weighted TSE) on the same day, from July 2018 to June 2019. Images were scored by seven musculoskeletal radiologists. The overall image quality, presence of artifacts, homogeneity of fat suppression, and visualization of cartilage, the triangular fibrocartilage complex (TFCC), and scapholunate and lunotriquetral ligaments were semiquantitatively assessed. Pairwise differences between 3 T and 7 T were assessed using the Wilcoxon signed-rank test. Interreader reliability was determined using the Fleiss kappa. Results In total, 25 healthy controls (mean age, 25 years ± 4 [SD]; 13 women) and 25 participants with chronic wrist pain (mean age, 39 years ± 16; 14 men) were included. Overall image quality (P = .002) and less presence of artifacts at PD-weighted fat-suppressed MRI were superior at 7 T. T1- and T2-weighted MRI were superior at 3 T (both P < .001), as was fat suppression (P < .001). Visualization of cartilage was superior at 7 T (P < .001), while visualization of the TFCC (P < .001) and scapholunate (P = .048) and lunotriquetral (P = .04) ligaments was superior at 3 T. Interreader reliability showed slight to substantial agreement for the detected pathologic conditions (κ = 0.20-0.64). Conclusion A 7-T MRI of the wrist had potential advantages over 3-T MRI, particularly in cartilage assessment. However, superiority was not shown for all parameters; for example, visualization of the triangular fibrocartilage complex and wrist ligaments was superior at 3 T. © RSNA, 2023 Supplemental material is available for this article.


Assuntos
Dor Crônica , Punho , Masculino , Humanos , Feminino , Adulto , Estudos Prospectivos , Reprodutibilidade dos Testes , Articulação do Punho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Artralgia
15.
Radiology ; 306(3): e221250, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36125379

RESUMO

Background Long COVID occurs at a lower frequency in children and adolescents than in adults. Morphologic and free-breathing phase-resolved functional low-field-strength MRI may help identify persistent pulmonary manifestations after SARS-CoV-2 infection. Purpose To characterize both morphologic and functional changes of lung parenchyma at low-field-strength MRI in children and adolescents with post-COVID-19 condition compared with healthy controls. Materials and Methods Between August and December 2021, a cross-sectional clinical trial using low-field-strength MRI was performed in children and adolescents from a single academic medical center. The primary outcome was the frequency of morphologic changes at MRI. Secondary outcomes included MRI-derived functional proton ventilation and perfusion parameters. Clinical symptoms, the duration from positive reverse transcriptase-polymerase chain reaction test result, and serologic parameters were compared with imaging results. Nonparametric tests for pairwise and corrected tests for groupwise comparisons were applied to assess differences in healthy controls, recovered participants, and those with long COVID. Results A total of 54 participants after COVID-19 infection (mean age, 11 years ± 3 [SD]; 30 boys [56%]) and nine healthy controls (mean age, 10 years ± 3; seven boys [78%]) were included: 29 (54%) in the COVID-19 group had recovered from infection and 25 (46%) were classified as having long COVID on the day of enrollment. Morphologic abnormality was identified in one recovered participant. Both ventilated and perfused lung parenchyma (ventilation-perfusion [V/Q] match) was higher in healthy controls (81% ± 6.1) compared with the recovered group (62% ± 19; P = .006) and the group with long COVID (60% ± 20; P = .003). V/Q match was lower in patients with time from COVID-19 infection to study participation of less than 180 days (63% ± 20; P = .03), 180-360 days (63% ± 18; P = .03), and 360 days (41% ± 12; P < .001) as compared with the never-infected healthy controls (81% ± 6.1). Conclusion Low-field-strength MRI showed persistent pulmonary dysfunction in children and adolescents who recovered from COVID-19 and those with long COVID. Clinical trial registration no. NCT04990531 © RSNA, 2022 Supplemental material is available for this article. See also the editorial by Paltiel in this issue.


Assuntos
COVID-19 , Adolescente , Adulto , Criança , Humanos , Masculino , Estudos Transversais , Pulmão/diagnóstico por imagem , Síndrome de COVID-19 Pós-Aguda , SARS-CoV-2
16.
Magn Reson Med ; 90(1): 270-279, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36861449

RESUMO

PURPOSE: Studies on intravoxel incoherent motion (IVIM) imaging in the liver have been carried out with different acquisition protocols. The number of acquired slices and the distances between slices can influence IVIM measurements due to saturation effects, but these effects have often been disregarded. This study investigated differences in biexponential IVIM parameters between two slice settings. METHODS: Fifteen healthy volunteers (21-30 years) were examined at a field strength of 3 T. Diffusion-weighted images of the abdomen were acquired with 16 b values (0-800 s/mm2 ), with four slices for the few slices setting and 24-27 slices for the many slices setting. Regions of interest were manually drawn in the liver. The data were fitted with a monoexponential signal curve and a biexponential IVIM curve, and biexponential IVIM parameters were determined. The dependence on the slice setting was assessed with Student's t test for paired samples (normally distributed IVIM parameters) and the Wilcoxon signed-rank test (non-normally distributed parameters). RESULTS: None of the parameters were significantly different between the settings. For few slices and many slices, respectively, the mean values (SDs) for D $$ D $$ were 1.21 µm 2 / ms $$ 1.21{\upmu \mathrm{m}}^2/\mathrm{ms} $$ ( 0.19 µm 2 / ms $$ 0.19\kern0.3em {\upmu \mathrm{m}}^2/\mathrm{ms} $$ ) and 1.20 µm 2 / ms $$ 1.20{\upmu \mathrm{m}}^2/\mathrm{ms} $$ ( 0.11 µm 2 / ms $$ 0.11\kern0.3em {\upmu \mathrm{m}}^2/\mathrm{ms} $$ ); for f $$ f $$ they were 29.7% (6.2%) and 27.7% (3.6%); and for D * $$ {D}^{\ast } $$ they were 8.76 ⋅ 10 - 2 mm 2 / s $$ 8.76\cdot {10}^{-2}{\mathrm{mm}}^2/\mathrm{s} $$ ( 4.54 ⋅ 10 - 2 mm 2 / s $$ 4.54\cdot {10}^{-2}\kern0.3em {\mathrm{mm}}^2/\mathrm{s} $$ ) and 8.71 ⋅ 10 - 2 mm 2 / s $$ 8.71\cdot {10}^{-2}{\mathrm{mm}}^2/\mathrm{s} $$ ( 4.06 ⋅ 10 - 2 mm 2 / s $$ 4.06\cdot {10}^{-2}\kern0.3em {\mathrm{mm}}^2/\mathrm{s} $$ ). CONCLUSION: Biexponential IVIM parameters in the liver are comparable among IVIM studies that use different slice settings, with mostly negligible saturation effects. However, this may not hold for studies that use much shorter TR.


Assuntos
Abdome , Fígado , Humanos , Fígado/diagnóstico por imagem , Movimento (Física) , Abdome/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Difusão por Ressonância Magnética/métodos
17.
Magn Reson Med ; 89(1): 423-439, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36089798

RESUMO

PURPOSE: To enhance image quality of flow-compensated diffusion-weighted liver MRI data by increasing the lesion conspicuity and reducing the cardiac pulsation artifact using postprocessing algorithms. METHODS: Diffusion-weighted image data of 40 patients with liver lesions had been acquired at 1.5 T. These data were postprocessed with 5 different algorithms (weighted averaging, p-mean, percentile, outlier exclusion, and exception set). Four image properties of the postprocessed data were evaluated for optimizing the algorithm parameters. These properties were the lesion to tissue contrast-to-noise ratio (CNR), the reduction of the cardiac pulsation artifact, the data consistency, and the vessel darkness. They were combined into a total quality score ( Q total , $$ {Q}_{\mathrm{total}}, $$ set to 1 for the trace-weighted reference image), which was used to rate the image quality objectively. RESULTS: The weighted averaging algorithm performed best according to the total quality score ( Q total = 1.111 ± 0.067 $$ {Q}_{\mathrm{total}}=1.111\pm 0.067 $$ ). The further ranking was outlier exclusion algorithm ( Q total = 1.086 ± 0.061 $$ {Q}_{\mathrm{total}}=1.086\pm 0.061 $$ ), p-mean algorithm ( Q total = 1.045 ± 0.049 $$ {Q}_{\mathrm{total}}=1.045\pm 0.049 $$ ), percentile algorithm ( Q total = 1.012 ± 0.049 $$ {Q}_{\mathrm{total}}=1.012\pm 0.049 $$ ), and exception set algorithm ( Q total = 0.957 ± 0.027 $$ {Q}_{\mathrm{total}}=0.957\pm 0.027 $$ ). All optimized algorithms except for the exception set algorithm corrected the pulsation artifact and increased the lesion CNR. Changes in Q total $$ {Q}_{\mathrm{total}} $$ were significant for all optimized algorithms except for the percentile algorithm. Liver ADC was significantly reduced (except for the exception set algorithm), particularly in the left lobe. CONCLUSION: Postprocessing algorithms should be used for flow-compensated liver DWI. The proposed weighted averaging algorithm seems to be suited best to increase the image quality of artifact-corrupted flow-compensated diffusion-weighted liver data.


Assuntos
Algoritmos , Artefatos , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Difusão , Fígado/diagnóstico por imagem
18.
Magn Reson Med ; 89(3): 1102-1116, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36373186

RESUMO

PURPOSE: To evaluate the classifiability of small multiple sclerosis (MS)-like lesions in simulated sodium (23 Na) MRI for different 23 Na MRI contrasts and reconstruction methods. METHODS: 23 Na MRI and 23 Na inversion recovery (IR) MRI of a phantom and simulated brain with and without lesions of different volumes (V = 1.3-38.2 nominal voxels) were simulated 100 times by adding Gaussian noise matching the SNR of real 3T measurements. Each simulation was reconstructed with four different reconstruction methods (Gridding without and with Hamming filter, Compressed sensing (CS) reconstruction without and with anatomical 1 H prior information). Based on the mean signals within the lesion volumes of simulations with and without lesions, receiver operating characteristics (ROC) were determined and the area under the curve (AUC) was calculated to assess the classifiability for each lesion volume. RESULTS: Lesions show higher classifiability in 23 Na MRI than in 23 Na IR MRI. For typical parameters and SNR of a 3T scan, the voxel normed minimal classifiable lesion volume (AUC > 0.9) is 2.8 voxels for 23 Na MRI and 19 voxels for 23 Na IR MRI, respectively. In terms of classifiability, Gridding with Hamming filter and CS without anatomical 1 H prior outperform CS reconstruction with anatomical 1 H prior. CONCLUSION: Reliability of lesion classifiability strongly depends on the lesion volume and the 23 Na MRI contrast. Additional incorporation of 1 H prior information in the CS reconstruction was not beneficial for the classification of small MS-like lesions in 23 Na MRI.


Assuntos
Esclerose Múltipla , Sódio , Humanos , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Processamento de Imagem Assistida por Computador/métodos
19.
Magn Reson Med ; 89(1): 77-94, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36128895

RESUMO

PURPOSE: To evaluate the benefits and challenges of dynamic parallel transmit (pTx) pulses for fat saturation (FS) and water-excitation (WE), in the context of CEST MRI. METHODS: "Universal" kT -points (for FS) and spiral non-selective (for WE) trajectories were optimized offline for flip angle (FA) homogeneity. Routines to optimize the pulse shape online, based on the subject's fields maps, were implemented (target FA of 110°/0° for FS, 0°/5° for WE at fat/water frequencies). The pulses were inserted in a CEST sequence with a pTx readout. The different fat suppression schemes and their effects on CEST contrasts were compared in 12 volunteers at 7T. RESULTS: With a 25%-shorter pulse duration, pTx FS largely improved the FA homogeneity (root-mean-square-error (RMSE) = 12.3° vs. 53.4° with circularly-polarized mode, at the fat frequency). However, the spectral selectivity was degraded mainly in the cerebellum and close to the sinuses (RMSE = 5.8° vs. 0.2° at the water frequency). Similarly, pTx WE showed a trade-off between FA homogeneity and spectral selectivity compared to pTx non-selective pulses (RMSE = 0.9° and 1.1° at the fat and water frequencies, vs. 4.6° and 0.5°). In the brain, CEST metrics were reduced by up to 31.9% at -3.3 ppm with pTx FS, suggesting a mitigated lipid-induced bias. CONCLUSION: This clinically compatible implementation of dynamic pTx pulses improved the fat suppression homogeneity at 7T taking into account the subject-specific B0 heterogeneities online. This study highlights the lipid-induced biases on the CEST z-spectrum. The results are promising for body applications where B0 heterogeneities and fat are more substantial.


Assuntos
Imageamento por Ressonância Magnética , Água , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Meios de Contraste , Lipídeos , Algoritmos
20.
NMR Biomed ; 36(2): e4840, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36196511

RESUMO

The objective of the current study was to assess sodium (23 Na) and quantitative proton (1 H) parameter changes in muscle tissue with magnetic resonance imaging (MRI) after eccentric exercise and in delayed-onset muscle soreness (DOMS). Fourteen participants (mean age: 25 ± 4 years) underwent 23 Na/1 H MRI of the calf muscle on a 3-T MRI system before exercise (t0), directly after eccentric exercise (t1), and 48 h postintervention (t2). In addition to tissue sodium concentration (TSC), intracellular-weighted sodium (ICwS) signal was acquired using a three-dimensional density-adapted radial projection readout with an additional inversion recovery preparation module. Phantoms containing saline solution served as references to quantify sodium concentrations. The 1 H MRI protocol consisted of a T1 -weighted turbo spin echo sequence, a T2 -weighted turbo inversion recovery, as well as water T2 mapping and water T1 mapping. Additionally, blood serum creatine kinase (CK) levels were assessed at baseline and 48 h after exercise. The TSC and ICwS of exercised muscles increased significantly from t0 to t1 and decreased significantly from t1 to t2. In the soleus muscle (SM), ICwS decreased below baseline values at t2. In the tibialis anterior muscle (TA), TSC and ICwS remained at baseline levels at each measurement point. However, high-CK participants (i.e., participants with a more than 10-fold CK increase, n = 3) displayed different behavior, with 2- to 4-fold increases in TSC values in the medial gastrocnemius muscle (MGM) at t2. 1 H water T1 relaxation times increased significantly after 48 h in the MGM and SM. 1 H water T2 relaxation times and muscle volume increased in the MGM at t2. Sodium MRI parameters and water relaxation times peaked at different points. Whereas water relaxation times were highest at t2, sodium MRI parameters had already returned to baseline values (or even below baseline values, for low-CK participants) by this point. The observed changes in ion concentrations and water relaxation time parameters could enable a better understanding of the physiological processes during DOMS and muscle regeneration. In the future, this might help to optimize training and to reduce associated sports injuries.


Assuntos
Hidrogênio , Mialgia , Humanos , Adulto Jovem , Adulto , Mialgia/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/lesões , Sódio , Prótons , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA