Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Langmuir ; 33(41): 10807-10817, 2017 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-28938076

RESUMO

The scanning Kelvin probe (SKP) is a versatile method for the measurement of the Volta potential difference between a sample and the SKP-tip (ΔψsampleSKP-tip). Based on suitable calibration, this technique is highly suited for the application in corrosion science due to its ability to serve as a very sensitive noncontact and nondestructive method for determining the electrode potential, even at buried interfaces beneath coatings or on surfaces covered by ultrathin electrolyte layers, which are not accessible by standard reference electrodes. However, the potential of the reference (i.e., the SKP-tip) will be influenced by variations of the surrounding atmosphere, resulting in errors of the electrode potential referred to the sample. The objective of this work is to provide a stable SKP-tip which can be used in different or changing atmosphere, e.g., within a wide range of relative humidity (approximately 0-99%-rh) or varying O2 partial pressure, without showing a change of its potential (note that the work functions measured in non-UHV atmospheres are electrochemical in nature [Hausbrand et al. J. Electrochem. Soc. 2008, 155 (7), C369-C379], and hence in the following we will refer to the potential of the SKP-tip instead of its work function). In that regard, the SKP-tip is in a first approach modified with self-assembled monolayers (SAMs) in order to create a hydrophobic barrier between the metallic surface and the surrounding atmosphere. The changes in potential upon varying relative humidity (ΔErh) of different bare metallic substrates are quantified, and it is shown that these potential differences cannot be minimized by SAMs. On the contrary, the ΔErh increases for every examined material system modified with SAMs. The major explanation for this observation is the dipole layer at the interface metal|SAM, causing an interfacial adsorption of water molecules even in a preferred orientation of their dipole moments, which leads to a changed work function and consequently to the correlated electrode potential. However, thin paraffin coatings were found to lead to a strongly reduced ΔErh, finally validated with novel robust Ag/Ag+ reference electrodes. It is also shown that nickel as SKP-tip material is seemingly more stable in varying atmospheric conditions compared to widely used Ni/Cr, stainless steel, or gold as SKP-tip material.

3.
Appl Environ Microbiol ; 67(2): 1001-3, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11157278

RESUMO

To investigate iron uptake, a chromosomal locus containing three consecutive open reading frames, designated fhuC, fhuB, and fhuD, was identified in Staphylococcus aureus. Whereas the fhuC gene encodes an ATP-binding protein, fhuB and fhuD code for ferrichrome permeases and thus resemble an ATP-binding cassette transporter. A fhuB knockout mutant showed impaired uptake of iron bound to the siderophores but not of ferric chloride, suggesting that this operon is specific for siderophore-mediated iron uptake.


Assuntos
Proteínas de Escherichia coli , Compostos Férricos/metabolismo , Ácidos Hidroxâmicos/metabolismo , Proteínas de Membrana Transportadoras , Óperon , Proteínas Periplásmicas de Ligação , Staphylococcus aureus/genética , Staphylococcus aureus/metabolismo , Transportadores de Cassetes de Ligação de ATP , Proteínas de Transporte/genética , Proteínas de Transporte/metabolismo , Meios de Cultura , Proteínas de Membrana/genética , Proteínas de Membrana/metabolismo , Dados de Sequência Molecular , Mutação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA