RESUMO
BACKGROUND AND AIMS: The scarcity of suitable donor livers highlights a continuing need for innovation to recover organs with reversible injuries in liver transplantation. APPROACH AND RESULTS: Explanted human donor livers (n = 5) declined for transplantation were supported using xenogeneic cross-circulation of whole blood between livers and xeno-support swine. Livers and swine were assessed over 24 hours of xeno-support. Livers maintained normal global appearance, uniform perfusion, and preservation of histologic and subcellular architecture. Oxygen consumption increased by 75% ( p = 0.16). Lactate clearance increased from -0.4 ± 15.5% to 31.4 ± 19.0% ( p = 0.02). Blinded histopathologic assessment demonstrated improved injury scores at 24 hours compared with 12 hours. Vascular integrity and vasoconstrictive function were preserved. Bile volume and cholangiocellular viability markers improved for all livers. Biliary structural integrity was maintained. CONCLUSIONS: Xenogeneic cross-circulation provided multisystem physiological regulation of ex vivo human livers that enabled functional rehabilitation, histopathologic recovery, and improvement of viability markers. We envision xenogeneic cross-circulation as a complementary technique to other organ-preservation technologies in the recovery of marginal donor livers or as a research tool in the development of advanced bioengineering and pharmacologic strategies for organ recovery and rehabilitation.
Assuntos
Transplante de Fígado , Fígado , Humanos , Suínos , Animais , Fígado/patologia , Transplante de Fígado/métodos , Bile , Perfusão/métodos , Preservação de Órgãos/métodosRESUMO
Decompensated right ventricular failure (RVF) in pulmonary hypertension (PH) is fatal, with limited medical treatment options. Developing and testing novel therapeutics for PH requires a clinically relevant large animal model of increased pulmonary vascular resistance and RVF. This manuscript describes the method to induce an ovine PH-RVF model that utilizes left pulmonary artery (LPA) ligation, progressive main pulmonary artery (MPA) banding, and insertion of an RV pressure line for monitoring. The PA cuff and RV pressure tubing are connected to subcutaneous access ports. This model of PH-RVF is a versatile platform to control not only the disease severity, but also the RV's phenotypic response. Subjects undergo progressive PA band adjustments twice per week for approximately 9 weeks with sequential measures of RV pressure, PA cuff pressures, and mixed venous blood gas (SvO2). Subjects can further be exercised on a livestock treadmill while hemodynamic parameters are captured. At the initiation and endpoint of this model, ventricular function and dimensions are assessed using echocardiography. In this model, RV mean and systolic pressure increased to 28 ± 5 and 57 ± 7 mmHg at week 1, and further to 44 ± 7 and 93 ± 18 mmHg by week 9, respectively. Echocardiography demonstrates characteristic findings of PH-RVF, notably RV dilation, increased wall thickness, and septal bowing. The rate of PA banding has a significant impact on SvO2 and thus the model can be titrated to elicit varying RV phenotypes. When the PA cuff is tightened rapidly, it can lead to a precipitous decline in SvO2, leading to RV decompensation, whereas a slower, more paced strategy leads to an adaptive RV stress-load response that maintains physiologic SvO2. A faster rate of PA banding will also lead to more severe liver fibrosis. The addition of controlled exercise provides a useful platform for assessing the effects of physical exertion in a PH-RVF model. This chronic PH-RVF model provides a valuable tool for studying molecular mechanisms, developing diagnostic biomarkers, and evaluating mechanical circulatory support systems.
Assuntos
Modelos Animais de Doenças , Insuficiência Cardíaca , Hipertensão Pulmonar , Disfunção Ventricular Direita , Animais , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/etiologia , Ovinos , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/etiologia , Artéria Pulmonar/fisiopatologia , Ecocardiografia , HemodinâmicaRESUMO
BACKGROUND: Right heart failure is the major cause of death in pulmonary hypertension. Lung transplantation is the only long-term treatment option for patients who fail medical therapy. Due to the scarcity of donor lungs, there is a critical need to develop durable mechanical support for the failing right heart. A major design goal for durable support is to reduce the size and complexity of devices to facilitate ambulation. Toward this end, we sought to deploy wearable mechanical support technology in a sheep disease model of chronic right heart failure. METHODS: In 6 sheep with chronic right heart failure, a mechanical support system consisting of an extracorporeal blood pump coupled with a gas exchange unit was attached in a right atrium-to-left atrium configuration for up to 7 days. Circuit performance, hematologic parameters, and animal hemodynamics were analyzed. RESULTS: Six subjects underwent the chronic disease model for 56 to 71 days. Three of the subjects survived to the 7-day end-point for circulatory support. The circuit provided 2.8 (0.5) liter/min of flow compared to the native pulmonary blood flow of 3.5 (1.1) liter/min. The animals maintained physiologically balanced blood gas profile with a sweep flow of 1.2 (1.0) liter/min. Two animals freely ambulated while wearing the circuit. CONCLUSIONS: Our novel mechanical support system provided physiologic support for a large animal model of pulmonary hypertension with right heart failure. The small footprint of the circuit and the low sweep requirement demonstrate the feasibility of this technology to enable mobile ambulatory applications.
Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Hipertensão Pulmonar , Humanos , Animais , Ovinos , Hipertensão Pulmonar/terapia , Insuficiência Cardíaca/cirurgia , Hemodinâmica/fisiologia , Átrios do CoraçãoRESUMO
Congestive hepatopathy is becoming increasingly recognized among Fontan-palliated patients. Elevated central venous pressure is thought to drive the pathologic progression, characterized by sinusoidal dilatation, congestion, and fibrosis. A clinically relevant large animal model for congestive hepatopathy would provide a valuable platform for researching novel biomarkers, treatment, and prevention. Here, we report on a titratable, sheep pulmonary artery banding model for this disease application. Pulmonary artery banding was achieved by progressively inflating the implanted pulmonary artery cuff. Right ventricular catheter was implanted to draw venous blood samples and measure pressure. The pulmonary artery cuff pressure served as a surrogate for the intensity of pulmonary artery banding and was measured weekly. After about 9 wk, animals were euthanized, and the liver was harvested for histopathological assessment. Nine animal subjects received pulmonary artery banding for 64 ± 8 days. Four of the nine subjects exhibited moderate to severe liver injury, and three of those four exhibited bridging fibrosis. Increasing pulmonary artery cuff pressure significantly correlated with declining mixed venous oxygen saturation (P = 3.29 × 10-5), and higher congestive hepatic fibrosis score (P = 0.0238), suggesting that pulmonary artery banding strategy can be titrated to achieve right-sided congestion and liver fibrosis. Blood analyses demonstrated an increase in plasma bile acids, aspartate aminotransferase, and γ-glutamyltransferase among subjects with moderate to severe injury, further corroborating liver tissue findings. Our large animal pulmonary artery banding model recapitulates congestive hepatopathy and provides a basis to bridge the current gaps in scientific and clinical understanding about the disease.NEW & NOTEWORTHY We present here a large animal platform for congestive hepatopathy, a disease growing in clinical prevalence due to the increasing number of Fontan-palliated patients. Further data are needed to develop a better clinical management strategy for this poorly characterized patient population. Previous reports of animal models to study this disease have mostly been in small animals with limited fidelity. We show that congestive hepatopathy can be replicated in a chronic, progressive pulmonary artery banding model in sheep. We also show that the banding strategy can be controlled to titrate the level of liver injury. To date, we do not know of any other large animal model that can achieve this level of control over disease phenotype and clinical relevance.
Assuntos
Insuficiência Cardíaca , Doenças Vasculares , Animais , Humanos , Fibrose , Cirrose Hepática/patologia , Modelos Animais , Artéria Pulmonar , Ovinos , Modelos Animais de DoençasRESUMO
BACKGROUND: Xenogeneic cross-circulation (XC) is an experimental method for ex vivo organ support and recovery that could expand the pool of donor lungs suitable for transplantation. The objective of this study was to establish and validate a standardized, reproducible, and broadly applicable technique for performing xenogeneic XC to support and recover injured human donor lungs ex vivo. METHODS: Human donor lungs (n = 9) declined for transplantation were procured, cannulated, and subjected to 24 hours of xenogeneic XC with anesthetized xeno-support swine (Yorkshire/Landrace) treated with standard immunosuppression (methylprednisolone, mycophenolate mofetil, tacrolimus) and complement-depleting cobra venom factor. Standard lung-protective perfusion and ventilation strategies, including periodic lung recruitment maneuvers, were used throughout xenogeneic XC. Every 6 hours, ex vivo donor lung function (gas exchange, compliance, airway pressures, pulmonary vascular dynamics, lung weight) was evaluated. At the experimental endpoint, comprehensive assessments of the lungs were performed by bronchoscopy, histology, and electron microscopy. Student's t-test and 1-way analysis of variance with Dunnett's post-hoc test was performed, and p < 0.05 was considered significant. RESULTS: After 24 hours of xenogeneic XC, gas exchange (PaO2/FiO2) increased by 158% (endpoint: 364 ± 142 mm Hg; p = 0.06), and dynamic compliance increased by 127% (endpoint: 46 ± 20 ml/cmH2O; p = 0.04). Airway pressures, pulmonary vascular pressures, and lung weight remained stable (p > 0.05) and within normal ranges. Over 24 hours of xenogeneic XC, gross and microscopic lung architecture were preserved: airway bronchoscopy and parenchymal histomorphology appeared normal, with intact blood-gas barrier. CONCLUSIONS: Xenogeneic cross-circulation is a robust method for ex vivo support, evaluation, and improvement of injured human donor lungs declined for transplantation.
Assuntos
Transplante de Pulmão , Humanos , Suínos , Animais , Transplante de Pulmão/métodos , Pulmão , Perfusão/métodos , Doadores de Tecidos , Preservação de Órgãos/métodosRESUMO
INTRODUCTION: Right ventricular failure (RVF) is a major cause of mortality in pulmonary hypertension (PH). Mechanical circulatory support holds promise for patients with medically refractory PH, but there are no clinical devices for long-term right ventricular (RV) support. Investigations into optimal device parameters and circuit configurations for PH-induced RVF (PH-RVF) are needed. METHODS: Eleven sheep underwent previously published chronic PH model. We then evaluated a low-profile, ventricular assist device (VAD)-quality pump combined with a novel low-resistance membrane oxygenator (Pulmonary Assist Device, PAD) under one of four central cannulation strategies: right atrium-to-left atrium (RA-LA, N = 3), RA-to-pulmonary artery (RA-PA, N=3), pumpless pulmonary artery-to-left atrium (PA-LA, N = 2), and RA-to-ascending aorta (RA-Ao, N = 3). Acute-on-chronic RVF (AoC RVF) was induced, and mechanical support was provided for up to 6 hours at blood flow rates of 1 to 3 liter/min. Circuit parameters, physiologic, hemodynamic, and echocardiography data were collected. RESULTS: The RA-LA configuration achieved blood flow of 3 liter/min. Meanwhile, RA-PA and RA-Ao faced challenges maintaining 3 liter/min of flow due to higher circuit afterload. Pumpless PA-LA was flow-limited due to anatomical limitations inherent to this animal model. RA-LA and RA-Ao demonstrated serial RV unloading with increasing circuit flow, while RA-PA did not. RA-LA also improved left ventricular (LV) and septal geometry by echocardiographic assessment and had the lowest inotropic dependence. CONCLUSION: RA-LA and RA-Ao configurations unload the RV, while RA-LA also lowers pump speed and inotropic requirements, and improves LV mechanics. RA-PA provide inferior support for PH-RVF, while an alternate animal model is needed to evaluate PA-LA.
Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Hipertensão Pulmonar , Animais , Ovinos , Hipertensão Pulmonar/terapia , Ventrículos do Coração , Átrios do Coração , HemodinâmicaRESUMO
Improved approaches to expanding the pool of donor lungs suitable for transplantation are critically needed for the growing population with end-stage lung disease. Cross-circulation (XC) of whole blood between swine and explanted human lungs has previously been reported to enable the extracorporeal recovery of donor lungs that declined for transplantation due to acute, reversible injuries. However, immunologic interactions of this xenogeneic platform have not been characterized, thus limiting potential translational applications. Using flow cytometry and immunohistochemistry, we demonstrate that porcine immune cell and immunoglobulin infiltration occurs in this xenogeneic XC system, in the context of calcineurin-based immunosuppression and complement depletion. Despite this, xenogeneic XC supported the viability, tissue integrity, and physiologic improvement of human donor lungs over 24 hours of xeno-support. These findings provide targets for future immunomodulatory strategies to minimize immunologic interactions on this organ support biotechnology.
Assuntos
Transplante de Pulmão , Pulmão , Humanos , Suínos , Animais , Terapia de ImunossupressãoRESUMO
Swine (Sus scrofa domesticus) are commonly used large animal subjects for the study of disease and preclinical therapies. Organ machine perfusion is a therapy that has gained momentum as a research platform for the study of ex vivo organ preservation and therapeutics. However, complex perfusion circuits and research protocols often require large volumes of blood as perfusate. Here, we report a technique for increasing terminal blood yield during swine organ and blood procurement; our method involves acute normovolemic hemodilution and exsanguination via the femoral artery. We collected a total of 47 ± 4 mL/kg of blood and 4.3 ± 0.6 g/kg of hemoglobin, representing 73% ± 6% of the estimated blood volume and 64% ± 8% of the total estimated intravascular hemoglobin (n = 4). Neither pH, lactate, nor pO2 levels changed significantly during blood procurement. Acute normovolemic hemodilution is an effective method for increasing RBC and hemoglobin yield during blood procurement in swine.
Assuntos
Volume Sanguíneo , Hemodiluição , Animais , Hemodiluição/métodos , Hemodiluição/veterinária , Hemoglobinas , Humanos , Perfusão/veterinária , Cuidados Pré-Operatórios , SuínosRESUMO
Decompensated right ventricular failure (RVF) in patients with pulmonary hypertension (PH) is fatal, with limited treatment options. Novel mechanical circulatory support systems have therapeutic potential for RVF, but the development of these devices requires a large animal disease model that replicates the pathophysiology observed in humans. We previously reported an effective disease model of PH in sheep through ligation of the left pulmonary artery (PA) and progressive occlusion of the main PA. Herein, we report a case of acute decompensation with this model of chronic RVF. Gradual PA banding raised the RV pressure (maximum RV systolic/mean pressure = 95 mmHg/56 mmHg). Clinical findings and laboratory serum parameters suggested appropriate physiologic compensation for 7 weeks. However, mixed venous saturation declined precipitously on week 7, and creatinine increased markedly on week 9. By the 10th week, the animal developed dependent, subcutaneous edema. Subsequently, the animal expired during the induction of general anesthesia. Post-mortem evaluation revealed several liters of pleural effusion and ascites, RV dilatation, eccentric RV hypertrophy, and myocardial fibrosis. The presented case supports this model's relevance to the human pathophysiology of RVF secondary to PH and its value in the development of novel devices, therapeutics, and interventions.
Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Disfunção Ventricular Direita , Animais , Modelos Animais de Doenças , Insuficiência Cardíaca/etiologia , Humanos , Hipertensão Pulmonar/etiologia , Hipertrofia Ventricular Direita/etiologia , Artéria Pulmonar , Ovinos , Disfunção Ventricular Direita/etiologiaRESUMO
Although machine perfusion has gained momentum as an organ preservation technique in liver transplantation, persistent organ shortages and high waitlist mortality highlight unmet needs for improved organ salvage strategies. Beyond preservation, extracorporeal organ support platforms can also aid the development and evaluation of novel therapeutics. Here, we report the use of veno-arterial-venous (V-AV) cross-circulation (XC) with a swine host to provide normothermic support to extracorporeal livers. Functional, biochemical, and morphological analyses of the extracorporeal livers and swine hosts were performed over 12 hours of support. Extracorporeal livers maintained synthetic function through alkaline bile production and metabolic activity through lactate clearance and oxygen consumption. Beyond initial reperfusion, no biochemical evidence of hepatocellular injury was observed. Histopathologic injury scoring showed improvements in sinusoidal dilatation and composite acute injury scores after 12 hours. Swine hosts remained hemodynamically stable throughout XC support. Altogether, these outcomes demonstrate the feasibility of using a novel V-AV XC technique to provide support for extracorporeal livers in a swine model. V-AV XC has potential applications as a translational research platform and clinical biotechnology for donor organ salvage.
Assuntos
Transplante de Fígado , Traumatismo por Reperfusão , Animais , Circulação Cruzada , Humanos , Fígado/metabolismo , Fígado/patologia , Preservação de Órgãos/métodos , Perfusão/métodos , Traumatismo por Reperfusão/metabolismo , Traumatismo por Reperfusão/patologia , SuínosRESUMO
Blood contact with high surface area medical devices, such as dialysis and extracorporeal life support (ECLS), induces rapid surface coagulation. Systemic anticoagulation, such as heparin, is thus necessary to slow clot formation, but some patients suffer from bleeding complications. Both problems might be reduced by 1) replacing heparin anticoagulation with artificial surface inhibition of the protein adsorption that initiates coagulation and 2) selective inhibition of the intrinsic branch of the coagulation cascade. This approach was evaluated by comparing clot formation and bleeding times during short-term ECLS using zwitterionic polycarboxybetaine (PCB) surface coatings combined with either a potent, selective, bicyclic peptide inhibitor of activated Factor XII (FXII900) or standard heparin anticoagulation. Rabbits underwent venovenous ECLS with small sham oxygenators for 60 min using three means of anticoagulation (n = 4 ea): (1) PCB coating + FXII900 infusion, (2) PCB coating + heparin infusion with an activated clotting time of 220-300s, and (3) heparin infusion alone. Sham oxygenator blood clot weights in the PCB + FXII900 and PCB + heparin groups were 4% and 25% of that in the heparin group (p < 10-6 and p < 10-5), respectively. At the same time, the bleeding time remained normal in the PCB + FXII900 group (2.4 ± 0.2 min) but increased to 4.8 ± 0.5 and 5.1 ± 0.7 min in the PCB + heparin and heparin alone groups (p < 10-4 and 0.01). Sham oxygenator blood flow resistance was significantly lower in the PCB + FXII900 and PCB + heparin groups than in the heparin only group (p < 10-6 and 10-5). These results were confirmed by gross and scanning electron microscopy (SEM) images and fibrinopeptide A (FPA) concentrations. Thus, the combined use of PCB coating and FXII900 markedly reduced sham oxygenator coagulation and tissue bleeding times versus the clinical standard of heparin anticoagulation and is a promising anticoagulation method for clinical ECLS.
Assuntos
Anticoagulantes/farmacologia , Oxigenação por Membrana Extracorpórea , Fator XII/antagonistas & inibidores , Animais , Betaína , Coagulação Sanguínea , Heparina/farmacologia , Humanos , Ácidos Polimetacrílicos , Coelhos , Diálise RenalRESUMO
Extracorporeal life support (ECLS) is a resource-intensive technology. Disposable components are modifiable through device selection. Cost analysis tools are needed to inform cost-conscious device selection. We generated a disposable cost analysis to forecast estimated costs of device disposables that included an assumption table, net present value (NPV) analysis, and sensitivity analysis to examine device disposable costs over 5 years with different case volumes and device mixes. To demonstrate the function of the analysis, we included four device options using the following assumptions: 100 cases in year 1, 2.5% case growth rate, 10% discount rate, and $5,000 incremental cost (Device 4 only). Using estimated device costs of $3,000, $12,000, $13,000, and $20,000 and device mix percentages of 65%, 8%, 25%, and 2% for Device 1, 2, 3, and 4, respectively, the 5 year unadjusted and NPV of disposable device costs were $3,691,000 and $2,765,000, respectively. The sensitivity analysis incorporated six separate models with different device mix percentages. The highest and lowest estimated costs were found in Model F (75% Device 3 and 25% Device 4; NPV = $6,64,400) and Model B (100% Device 1; NPV = 1,246,000) respectively. Extracorporeal life support programs may apply this disposable cost analysis tool to reduce programmatic costs.
Assuntos
Oxigenação por Membrana Extracorpórea , Análise Custo-BenefícioRESUMO
Decompensated right ventricular failure (RVF) in pulmonary hypertension (PH) is fatal, with limited medical treatment options. Developing and testing novel therapeutics for PH requires a clinically relevant large animal model of increased pulmonary vascular resistance and RVF. This manuscript discusses the latest development of the previously published ovine PH-RVF model that utilizes left pulmonary artery (PA) ligation and main PA occlusion. This model of PH-RVF is a versatile platform to control not only the disease severity but also the RV's phenotypic response. Adult sheep (60-80 kg) underwent left PA (LPA) ligation, placement of main PA cuff, and insertion of RV pressure monitor. PA cuff and RV pressure monitor were connected to subcutaneous ports. Subjects underwent progressive PA banding twice per week for 9 weeks with sequential measures of RV pressure, PA cuff pressures, and mixed venous blood gas (SvO2). At the initiation and endpoint of this model, ventricular function and dimensions were assessed using echocardiography. In a representative group of 12 animal subjects, RV mean and systolic pressure increased from 28 ± 5 and 57 ± 7 mmHg at week 1, respectively, to 44 ± 7 and 93 ± 18 mmHg (mean ± standard deviation) by week 9. Echocardiography demonstrated characteristic findings of PH-RVF, notably RV dilation, increased wall thickness, and septal bowing. The longitudinal trend of SvO2 and PA cuff pressure demonstrates that the rate of PA banding can be titrated to elicit varying RV phenotypes. A faster PA banding strategy led to a precipitous decline in SvO2 < 65%, indicating RV decompensation, whereas a slower, more paced strategy led to the maintenance of physiologic SvO2 at 70%-80%. One animal that experienced the accelerated strategy developed several liters of pleural effusion and ascites by week 9. This chronic PH-RVF model provides a valuable tool for studying molecular mechanisms, developing diagnostic biomarkers, and enabling therapeutic innovation to manage RV adaptation and maladaptation from PH.
Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Disfunção Ventricular Direita , Animais , Modelos Animais de Doenças , Hipertensão Pulmonar/etiologia , Artéria Pulmonar/cirurgia , Ovinos , Disfunção Ventricular Direita/etiologia , Função Ventricular DireitaRESUMO
Pulmonary hypertension (PH) is a progressive disease that leads to cardiopulmonary dysfunction and right heart failure from pressure and volume overloading of the right ventricle (RV). Mechanical cardiopulmonary support has theoretical promise as a bridge to organ transplant or destination therapy for these patients. Solving the challenges of mechanical cardiopulmonary support for PH and RV failure requires its testing in a physiologically relevant animal model. Previous PH models in large animals have used pulmonary bead embolization, which elicits unpredictable inflammatory responses and has a high mortality rate. We describe a step-by-step guide for inducing pulmonary hypertension and right ventricular hypertrophy (PH-RVH) in sheep by left pulmonary artery (LPA) ligation combined with progressive main pulmonary artery (MPA) banding. This approach provides a controlled method to regulate RV afterload as tolerated by the animal to achieve PH-RVH, while reducing acute mortality. This animal model can facilitate evaluation of mechanical support devices for PH and RV failure.
Assuntos
Modelos Animais de Doenças , Hipertensão Pulmonar , Hipertrofia Ventricular Direita , Disfunção Ventricular Direita , Animais , Hipertensão Pulmonar/fisiopatologia , Hipertrofia Ventricular Direita/fisiopatologia , Ligadura , Masculino , Artéria Pulmonar/fisiopatologia , Artéria Pulmonar/cirurgia , Ovinos , Disfunção Ventricular Direita/fisiopatologiaRESUMO
Recently a hinge point or the maximum bending stress point of the popliteal artery was identified when the knee bends using a lateral view dynamic angiography and a correlation between the lateral view angiography with the extended limb angiography to predict the potential location of the hinge point was defined. A hinge point has been correlated to stent fracture. These findings allowed us to develop a dynamic classification of the popliteal artery. The dynamic classification is useful for endovascular procedures in the popliteal artery. Cultural aspects of our patient population must be considered previous to the endovascular treatment of the popliteal artery, especially to the Japanese culture, which is commonly observed sitting posture such as "seiza ()."
RESUMO
Microchannel artificial lungs may provide highly efficient, long-term respiratory support, but a robust predictive oxygen transfer (VO2) model is needed to better design them. To meet this need, we first investigated the predictive accuracy of Mikic, Benn, and Drinker's advancing front (AF) oxygen transfer theory by applying it to previous microchannel lung studies. Here, the model that included membrane resistance showed no bias toward overprediction or underprediction of VO2 (median error: -1.13%, interquartile range: [-26.9%, 19.2%]) and matched closely with existing theory. Next, this theory was expanded into a general model for investigating a family of designs. The overall model suggests that, for VO2 = 100 ml/min, fraction of delivered oxygen (FDO2) = 40%, wall shear stress ((Equation is included in full-text article.)) = 30 dyn/cm, and blood channel height = 20-50 µm, a compact design can be achieved with priming volume ((Equation is included in full-text article.)) = 5.8-32 ml; however, manifolding may be challenging to satisfy the rigorous total width ((Equation is included in full-text article.)) requirement ((Equation is included in full-text article.)= 76-475 m). In comparison, 100-200 µm heights would yield larger dimensions ((Equation is included in full-text article.)122-478 ml) but simpler manifolding ((Equation is included in full-text article.)4.75-19.0 m). The device size can be further adjusted by varying FDO2, (Equation is included in full-text article.), or VO2. This model may thus serve as a simple yet useful tool to better design microchannel artificial lungs.
Assuntos
Órgãos Artificiais , Desenho de Equipamento , Pulmão , Modelos BiológicosRESUMO
BACKGROUND: Single-site, dual-lumen venovenous extracorporeal membrane oxygenation ECMO) facilitates mobilization, reduces recirculation, and mitigates insertion and infectious risks of an additional access site. This study reports the experience with a bicaval dual-lumen cannula that comprises a robust physical design allowing for easy and safe cannulation, precise positioning and monitoring, and appropriate physiologic support for patients with acute respiratory failure. METHODS: Statistical analysis was performed from data gathered retrospectively from the electronic medical records of 20 adult patients who were cannulated for ECMO with this bicaval dual-lumen cannula from August 2018 through May 2019. RESULTS: Gas exchange and blood flow were optimized in all patients after cannulation (median pH, 7.42 [interquartile range {IQR}, 7.39, 7.44], ratio of arterial partial pressure of oxygen to fraction of inspired oxygen, 186.5 [Pao2:Fio2, 116.5, 247.0]; pump flow, 3.9 L/min [IQR, 3.1, 4.3]). Eleven patients (55%) were able to be freed from mechanical ventilation after cannulation, 9 (45%) patients underwent a tracheostomy procedure while undergoing ECMO, and no patients required reintubation. No morbidity or mortality was related to the cannulation strategy or the catheter. Two patients required cannula repositioning. Survival to decannulation was 90%, and survival to hospital discharge was 80%. CONCLUSIONS: The bicaval dual-lumen cannula maintains the advantages of upper body single-site configuration to provide the adjunctive respiratory support necessary to facilitate awakening and rehabilitation while minimizing the use of invasive mechanical ventilation. This cannula introduces design qualities that may offer advantages for acute respiratory failure requiring venovenous ECMO.
Assuntos
Cânula , Oxigenação por Membrana Extracorpórea/instrumentação , Insuficiência Respiratória/terapia , Doença Aguda , Adulto , Cateterismo , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Respiração Artificial , Estudos RetrospectivosRESUMO
Patients awaiting lung transplantation face high wait-list mortality, as injury precludes the use of most donor lungs. Although ex vivo lung perfusion (EVLP) is able to recover marginal quality donor lungs, extension of normothermic support beyond 6 h has been challenging. Here we demonstrate that acutely injured human lungs declined for transplantation, including a lung that failed to recover on EVLP, can be recovered by cross-circulation of whole blood between explanted human lungs and a Yorkshire swine. This xenogeneic platform provided explanted human lungs a supportive, physiologic milieu and systemic regulation that resulted in functional and histological recovery after 24 h of normothermic support. Our findings suggest that cross-circulation can serve as a complementary approach to clinical EVLP to recover injured donor lungs that could not otherwise be utilized for transplantation, as well as a translational research platform for immunomodulation and advanced organ bioengineering.
Assuntos
Lesão Pulmonar Aguda/terapia , Transplante de Pulmão/métodos , Pulmão/irrigação sanguínea , Preservação de Órgãos/métodos , Lesão Pulmonar Aguda/sangue , Lesão Pulmonar Aguda/fisiopatologia , Animais , Circulação Extracorpórea/métodos , Humanos , Pulmão/fisiopatologia , Perfusão/métodos , Suínos , Doadores de TecidosRESUMO
The large, densely packed artificial surface area of artificial lungs results in rapid clotting and device failure. Surface generated nitric oxide (NO) can be used to reduce platelet activation and coagulation on gas exchange fibers, while not inducing patient bleeding due to its short half-life in blood. To generate NO, artificial lungs can be manufactured with PDMS hollow fibers embedded with copper nanoparticles (Cu NP) and supplied with an infusion of the NO donor S-nitroso-N-acetyl-penicillamine (SNAP). The SNAP reacts with Cu NP to generate NO. This study investigates clot formation and gas exchange performance of artificial lungs with either NO-generating Cu-PDMS or standard polymethylpentene (PMP) fibers. One miniature artificial lung (MAL) made with 10â¯wt% Cu-PDMS hollow fibers and one PMP control MAL were attached to sheep in parallel in a veno-venous extracorporeal membrane oxygenation circuit (nâ¯=â¯8). Blood flow through each device was set at 300â¯mL/min, and each device received a SNAP infusion of 0.12⯵mol/min. The ACT was between 110 and 180â¯s in all cases. Blood flow resistance was calculated as a measure of clot formation on the fiber bundle. Gas exchange experiments comparing the two groups were conducted every 24â¯h at blood flow rates of 300 and 600â¯mL/min. Devices were removed once the resistance reached 3x baseline (failure) or following 72â¯h. All devices were imaged using scanning electron microscopy (SEM) at the inlet, outlet, and middle of the fiber bundle. The Cu-PDMS NO generating MALs had a significantly smaller increase in resistance compared to the control devices. Resistance rose from 26⯱â¯8 and 23⯱â¯5 in the control and Cu-PDMS devices, respectively, to 35⯱â¯8â¯mmHg/(mL/min) and 72⯱â¯23â¯mmHg/(mL/min) at the end of each experiment. The resistance and SEM imaging of fiber surfaces demonstrate lower clot formation on Cu-PDMS fibers. Although not statistically significant, oxygen transfer for the Cu-PDMS MALs was 13.3% less than the control at 600â¯mL/min blood flow rate. Future in vivo studies with larger Cu-PDMS devices are needed to define gas exchange capabilities and anticoagulant activity over a long-term study at clinically relevant ACTs. STATEMENT OF SIGNIFICANCE: In artificial lungs, the large, densely-packed blood contacting surface area of the hollow fiber bundle is critical for gas exchange but also creates rapid, surface-generated clot requiring significant anticoagulation. Monitoring of anticoagulation, thrombosis, and resultant complications has kept permanent respiratory support from becoming a clinical reality. In this study, we use a hollow fiber material that generates nitric oxide (NO) to prevent platelet activation at the blood contacting surface. This material is tested in vivo in a miniature artificial lung and compared against the clinical standard. Results indicated significantly reduced clot formation. Surface-focused anticoagulation like this should reduce complication rates and allow for permanent respiratory support by extending the functional lifespan of artificial lungs and can further be applied to other medical devices.
Assuntos
Órgãos Artificiais , Cobre/química , Pulmão , Nanopartículas Metálicas/química , Óxido Nítrico , S-Nitroso-N-Acetilpenicilamina , Animais , Dimetilpolisiloxanos , Óxido Nítrico/química , Óxido Nítrico/farmacocinética , Óxido Nítrico/farmacologia , Nylons , S-Nitroso-N-Acetilpenicilamina/química , S-Nitroso-N-Acetilpenicilamina/farmacocinética , S-Nitroso-N-Acetilpenicilamina/farmacologia , Ovinos , Fatores de TempoRESUMO
Current artificial lungs fail in 1-4â¯weeks due to surface-induced thrombosis. Biomaterial coatings may be applied to anticoagulate artificial surfaces, but none have shown marked long-term effectiveness. Poly-carboxybetaine (pCB) coatings have shown promising results in reducing protein and platelet-fouling in vitro. However, in vivo hemocompatibility remains to be investigated. Thus, three different pCB-grafting approaches to artificial lung surfaces were first investigated: 1) graft-to approach using 3,4-dihydroxyphenylalanine (DOPA) conjugated with pCB (DOPA-pCB); 2) graft-from approach using the Activators ReGenerated by Electron Transfer method of atom transfer radical polymerization (ARGET-ATRP); and 3) graft-to approach using pCB randomly copolymerized with hydrophobic moieties. One device coated with each of these methods and one uncoated device were attached in parallel within a veno-venous sheep extracorporeal circuit with no continuous anticoagulation (Nâ¯=â¯5 circuits). The DOPA-pCB approach showed the least increase in blood flow resistance and the lowest incidence of device failure over 36-hours. Next, we further investigated the impact of tip-to-tip DOPA-pCB coating in a 4-hour rabbit study with veno-venous micro-artificial lung circuit at a higher activated clotting time of 220-300â¯s (Nâ¯≥â¯5). Here, DOPA-pCB reduced fibrin formation (pâ¯=â¯0.06) and gross thrombus formation by 59% (pâ¯<â¯0.05). Therefore, DOPA-pCB is a promising material for improving the anticoagulation of artificial lungs. STATEMENT OF SIGNIFICANCE: Chronic lung diseases lead to 168,000 deaths each year in America, but only 2300 lung transplantations happen each year. Hollow fiber membrane oxygenators are clinically used as artificial lungs to provide respiratory support for patients, but their long-term viability is hindered by surface-induced clot formation that leads to premature device failure. Among different coatings investigated for blood-contacting applications, poly-carboxybetaine (pCB) coatings have shown remarkable reduction in protein adsorption in vitro. However, their efficacy in vivo remains unclear. This is the first work that investigates various pCB-coating methods on artificial lung surfaces and their biocompatibility in sheep and rabbit studies. This work highlights the promise of applying pCB coatings on artificial lungs to extend its durability and enable long-term respiratory support for lung disease patients.