Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
ASAIO J ; 68(3): 333-339, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34310094

RESUMO

Early right heart failure (RHF) occurs in up to 40% of patients following left ventricular assist device (LVAD) implantation and is associated with increased morbidity and mortality. The most recent report from the Mechanical Circulatory Support-Academic Research Consortium (MCS-ARC) working group subdivides early RHF into early acute RHF and early postimplant RHF. We sought to determine the effectiveness of right ventricular (RV) longitudinal strain (LS) in predicting RHF according to the new MCS-ARC definition. We retrospectively analyzed clinical and echocardiographic data of patients who underwent LVAD implantation between 2015 and 2018. RVLS in the 4-chamber (4ch), RV outflow tract, and subcostal views were measured on pre-LVAD echocardiograms. Fifty-five patients were included in this study. Six patients (11%) suffered early acute RHF, requiring concomitant RVAD implantation intraoperatively. Twenty-two patients (40%) had postimplant RHF. RVLS was significantly reduced in patients who developed early acute and postimplant RHF. At a cutoff of -9.7%, 4ch RVLS had a sensitivity of 88.9% and a specificity of 77.8% for predicting RHF and area under the receiver operating characteristic curve of 0.86 (95% confidence interval 0.76-0.97). Echocardiographic RV strain outperformed more invasive hemodynamic measures and clinical parameters in predicting RHF.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia
2.
ASAIO J ; 67(11): e198-e200, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33741789

RESUMO

Durable left ventricular assist devices (LVAD) are frequently complicated by driveline infection. The objective of this case series was to examine whether an association exists between driveline infection and intracranial hemorrhage. This retrospective case series included patients at a single tertiary care hospital on durable LVAD support who developed intracranial hemorrhage. Physical examination data, vital signs, and laboratory markers of sepsis including blood cultures and imaging of driveline sites were reviewed. A total of nine patients were included in the case series. At the time of hemorrhagic event, five patients had active driveline infection, and five patients were found to be bacteremic. All bacteremic patients were found to have supratherapeutic INR at the time of presentation. Although five patients experienced subarachnoid hemorrhage, only one patient was found to have a cerebral aneurysm. This case series highlights a possible association between LVAD driveline infection and intracranial hemorrhage, and the need for further research to better understand the pathophysiology driving this association.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Infecções Relacionadas à Prótese , Sepse , Hemorragia Subaracnóidea , Insuficiência Cardíaca/etiologia , Coração Auxiliar/efeitos adversos , Humanos , Hemorragias Intracranianas/etiologia , Infecções Relacionadas à Prótese/etiologia , Estudos Retrospectivos , Hemorragia Subaracnóidea/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA