Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Haemophilia ; 26(3): 543-552, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32314511

RESUMO

INTRODUCTION: Recombinant factor IX Fc fusion protein (rFIXFc) is an extended half-life concentrate for the treatment of haemophilia B (HB). rFIXFc activity monitoring is crucial in several clinical situations. However, differences were observed between one-stage clotting (OSC) and chromogenic assays, but not for all factor IX (FIX) concentrations. AIMS: To compare rFIXFc measurements obtained using different instruments and common OSC and chromogenic asssays. METHODS: FIX:C measurements were performed in rFIXFc-spiked plasma aliquots (targeted FIX levels of 1.5, 1, 0.5, 0.2, 0.05, 0.02 and 0.01 IU/mL) and plasma samples collected from two patients with HB at various time points after rFIXFc infusion, using three instruments (STA-R MAX, ACLTOP700 and CS2100i) and common clotting and chromogenic FIX:C assays. RESULTS: The same reagent could give different FIX:C measurements when adapted to different instruments. Moreover, the same reagent/instrument combination could give different results depending of the FIX concentration. For OSC assays, only STA-Cephascreen on STA-R MAX and CS2100i, SynthAFax on ACLTOP 700 and Actin on CS2100i provided acceptable recoveries for all rFIXFc concentrations. The chromogenic assays ROX-FIX and Biophen FIX:C underestimated rFIXFc for concentrations lower than 0.05 and 0.2 IU/mL, respectively. CONCLUSIONS: Our study demonstrates that the same reagent adapted to different instruments could lead to different rFIXFc values. As rFIXFc under/overestimation could be associated with inappropriate treatment or biased calculation of pharmacokinetic parameters, the reagent/instrument combination used by haemostasis laboratories should be considered and regularly evaluated by external quality assessment programmes.


Assuntos
Fator IX/farmacologia , Fragmentos Fc das Imunoglobulinas/farmacologia , Indicadores e Reagentes/farmacologia , Proteínas Recombinantes de Fusão/farmacologia , Adolescente , Feminino , Humanos , Masculino
2.
Ann Biol Clin (Paris) ; 78(6): 629-638, 2020 Dec 01.
Artigo em Francês | MEDLINE | ID: mdl-33262100

RESUMO

Exploring coagulation in newborns and children is a challenge due to the low levels of both procoagulant factors and inhibitors. Conventional coagulation tests might be inadequate to explore all of these changes. The aim of the study is to evaluate the thrombin generation assay, a global test to explore coagulation, in a pediatric population (n=586) compared to an adult population (n=166). The thrombin generation assays were performed using Calibrated Automated Thrombography with two different tissue factor concentrations (1 and 5 pM), with and without thrombomodulin (TM). In the absence of TM, the endogenous thrombin potential (ETP) is significantly lower in the pediatric population, reflecting the decrease in procoagulant factors. In the presence of TM, ETP values in pediatric subjects are within the reference range of adult values. The thrombin generation assay demonstrates that coagulation balance is maintained in the pediatric population.


Assuntos
Pediatria/normas , Trombina/análise , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Testes de Coagulação Sanguínea/métodos , Testes de Coagulação Sanguínea/normas , Calibragem , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Saúde , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Pediatria/métodos , Valor Preditivo dos Testes , Valores de Referência , Trombina/metabolismo , Trombina/normas , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA