Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 96(1): 238-247, 2024 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-38117670

RESUMO

Hypoxia-inducible factor (HIF) stabilizers are listed in the World Anti-Doping Agency's prohibited list as they can increase aerobic exercise capacity. The rapid pace of emergence of highly structurally diverse HIF stabilizers could pose a risk to conventional structure-based methods in doping control to detect new investigational drugs. Therefore, we developed a strategy that is capable of detecting the presence of any HIF stabilizer, irrespective of its structure, by detecting biological activity. Previously developed cell-based HIF1/2 assays were optimized to a stable format and evaluated for their screening potential toward HIF stabilizers. Improved pharmacological characterization was established by the stable cell-based formats, and broad specificity was demonstrated by pharmacologically characterizing a diverse set of HIF stabilizers (including enarodustat, IOX2, IOX4, MK-8617, JNJ-42041935). The methodological (in solvent) limit of detection of the optimal HIF1 stable bioassay toward detecting the reference compound roxadustat was 100 nM, increasing to 50-100 ng/mL (corresponding to 617-1233 nM in-well) in matching urine samples, owing to strong matrix effects. In a practical context, a urinary limit of detection of 1.15 µg/mL (95% detection rate) was determined, confirming the matrix-dependent detectability of roxadustat in urine. Pending optimization of a universal sample preparation strategy and/or a methodology to correct for the matrix effects, this untargeted approach may serve as a complementing method in antidoping control, as theoretically, it would be capable of detecting any unknown substance with HIF stabilizing activity.


Assuntos
Dopagem Esportivo , Detecção do Abuso de Substâncias/métodos , Glicina/química , Pirazóis , Triazóis
2.
BMC Biol ; 20(1): 151, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35761265

RESUMO

BACKGROUND: Colorectal cancer, one of the most common malignancies worldwide, is associated with a high mortality rate, mainly caused by metastasis. Comparative metagenome-wide association analyses of healthy individuals and cancer patients suggest a role for the human intestinal microbiota in tumor progression. However, the microbial molecules involved in host-microbe communication are largely unknown, with current studies mainly focusing on short-chain fatty acids and amino acid metabolites as potential mediators. Quorum sensing peptides are not yet considered in this context since their presence in vivo and their ability to affect host cells have not been reported so far. RESULTS: Here, we show that EntF*, a metabolite of the quorum sensing peptide EntF produced by Enterococcus faecium, is naturally present in mice bloodstream. Moreover, by using an orthotopic mouse model, we show that EntF* promotes colorectal cancer metastasis in vivo, with metastatic lesions in liver and lung tissues. In vitro tests suggest that EntF* regulates E-cadherin expression and consequently the epithelial-mesenchymal transition, via the CXCR4 receptor. In addition, alanine-scanning analysis indicates that the first, second, sixth, and tenth amino acid of EntF* are critical for epithelial-mesenchymal transition and tumor metastasis. CONCLUSION: Our work identifies a new class of molecules, quorum sensing peptides, as potential regulators of host-microbe interactions. We prove, for the first time, the presence of a selected quorum sensing peptide metabolite in a mouse model, and we demonstrate its effects on colorectal cancer metastasis. We believe that our work represents a starting point for future investigations on the role of microbiome in colorectal cancer metastasis and for the development of novel bio-therapeutics in other disease areas.


Assuntos
Neoplasias Colorretais , Microbiota , Aminoácidos , Animais , Humanos , Camundongos , Microbiota/fisiologia , Peptídeos , Percepção de Quorum/fisiologia
3.
Biomed Chromatogr ; 35(2): e4970, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32840903

RESUMO

As hypoxia-inducible factor stabilizers (HIFs) can artificially enhance an athlete's erythropoiesis, the World Anti-Doping Agency prohibits their use at all times. Every urine sample for doping control analysis has to be evaluated for the presence of HIFs and therefore sensitive methods that allow high sample throughput are needed. Samples suspicious for the presence of HIFs need to be confirmed following the identification criteria established by the World Anti-Doping Agency. Previous work has shown the advantages of using turbulent flow online solid-phase extraction (SPE) procedures to reduce matrix effects and retention time shifts. Furthermore, the use of online SPE allows for automation and high sample throughput. Both an initial testing procedure (ITP) and a confirmation method were developed and validated, using online SPE liquid chromatography-tandem mass spectrometry (LC-MS/MS), with limits of detection between 0.1 ng/ml (or possibly lower) and 4 ng/ml (or higher for GSK360a) and limits of identification between 0.1 ng/ml (or possibly lower) and 1.17 ng/ml. The ITP only takes 6.5 min per sample. To the best of our knowledge, these are the first ITP and confirmation methods that include more than three HIFs without the need for manual sample preparation.


Assuntos
Dopagem Esportivo , Fator 1 Induzível por Hipóxia/química , Pirazóis/urina , Detecção do Abuso de Substâncias/métodos , Triazóis/urina , Cromatografia Líquida/métodos , Glicina/análogos & derivados , Glicina/química , Glicina/urina , Humanos , Isoquinolinas/química , Isoquinolinas/urina , Limite de Detecção , Modelos Lineares , Pirazóis/química , Reprodutibilidade dos Testes , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Triazóis/química
4.
Anal Biochem ; 537: 69-71, 2017 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-28887173

RESUMO

The tendency of peptides to adsorb to surfaces can raise a concern in variety of analytical fields where the qualitative/quantitative measurement of low concentration analytes (ng/mL-pg/mL) is required. To demonstrate the importance of using the optimal glassware/plasticware, four doping relevant model peptides (GHRP 5, TB-500, Insulin Lispro, Synachten) were chosen and their recovery from various surfaces were evaluated. Our experiments showed that choosing expensive consumables with low-bind characteristics is not beneficial in all cases. A careful selection of the consumables based on the evaluation of the physico/chemical features of the peptide is recommended.


Assuntos
Cosintropina/química , Dopagem Esportivo , Insulina Lispro/química , Oligopeptídeos/química , Adsorção , Animais , Cromatografia Líquida de Alta Pressão , Cosintropina/sangue , Vidro/química , Humanos , Insulina Lispro/sangue , Oligopeptídeos/sangue , Polipropilenos/química
5.
Rapid Commun Mass Spectrom ; 30(4): 511-22, 2016 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-26777682

RESUMO

RATIONALE: The detection of new anabolic steroid metabolites and new designer steroids is a challenging task in doping analysis. Switching from electron ionization gas chromatography triple quadrupole mass spectrometry (GC/EI-MS/MS) to chemical ionization (CI) has proven to be an efficient way to increase the sensitivity of GC/MS/MS analyses and facilitate the detection of anabolic steroids. CI also extends the possibilities of GC/MS/MS analyses as the molecular ion is retained in its protonated form due to the softer ionization. In EI it can be difficult to find previously unknown but expected metabolites due to the low abundance or absence of the molecular ion and the extensive (and to a large extent unpredictable) fragmentation. The main aim of this work was to study the CI and collision-induced dissociation (CID) behavior of a large number of anabolic androgenic steroids (AAS) as their trimethylsilyl derivatives in order to determine correlations between structures and CID fragmentation. Clarification of these correlations is needed for the elucidation of structures of unknown steroids and new metabolites. METHODS: The ionization and CID behavior of 65 AAS have been studied using GC/CI-MS/MS with ammonia as the reagent gas. Glucuronidated AAS reference standards were first hydrolyzed to obtain their free forms. Afterwards, all the standards were derivatized to their trimethylsilyl forms. Full scan and product ion scan analyses were used to examine the ionization and CID behavior. RESULTS: Full scan and product ion scan analyses revealed clear correlations between AAS structure and the obtained mass spectra. These correlations were confirmed by analysis of multiple hydroxylated, methylated, chlorinated and deuterated analogs. CONCLUSIONS: AAS have been divided into three groups according to their ionization behavior and into seven groups according to their CID behavior. Correlations between fragmentation and structure were revealed and fragmentation pathways were postulated.


Assuntos
Anabolizantes/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Esteroides/química , Estrutura Molecular
6.
Biomed Chromatogr ; 30(8): 1202-9, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26663462

RESUMO

The use of anabolic steroids is prohibited in sports. Effective control is done by monitoring their metabolites in urine samples collected from athletes. Ethical objections however restrict the use of designer steroids in human administration studies. To overcome these problems alternative in vitro and in vivo models were developed to identify metabolites and to assure a fast response by anti-doping laboratories to evolutions on the steroid market. In this study human liver microsomes and an uPA(+/+) -SCID chimeric mouse model were used to elucidate the metabolism of a steroid product called 'Xtreme DMZ'. This product contains the designer steroid dimethazine (DMZ), which consists of two methasterone molecules linked by an azine group. In the performed stability study, degradation from dimethazine to methasterone was observed. By a combination of LC-High Resolution Mass Spectrometry (HRMS) and GC-MS(/MS) analysis methasterone and six other dimethazine metabolites (M1-M6), which are all methasterone metabolites, could be detected besides the parent compound in both models. The phase II metabolism of dimethazine was also investigated in the mouse urine samples. Only metabolites M1 and M2 were exclusively detected in the glucuro-conjugated fraction; all other compounds were also found in the free fraction. For effective control of DMZ misuse in doping control samples, screening for methasterone and methasterone metabolites should be sufficient. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Androstanóis/farmacocinética , Animais , Cromatografia Líquida/métodos , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Técnicas In Vitro , Camundongos , Camundongos SCID , Microssomos Hepáticos/metabolismo , Espectrometria de Massas em Tandem/métodos
7.
Anal Chem ; 87(16): 8373-80, 2015 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-26200763

RESUMO

The use of untargeted metabolomics for the discovery of markers is a promising and virtually unexplored tool in the doping control field. Hybrid quadrupole time-of-flight (QTOF) and hybrid quadrupole Orbitrap (Q Exactive) mass spectrometers, coupled to ultrahigh pressure liquid chromatography, are excellent tools for this purpose. In the present work, QTOF and Q Exactive have been used to look for markers for testosterone cypionate misuse by means of untargeted metabolomics. Two different groups of urine samples were analyzed, collected before and after the intramuscular administration of testosterone cypionate. In order to avoid analyte losses in the sample treatment, samples were just 2-fold diluted with water and directly injected into the chromatographic system. Samples were analyzed in both positive and negative ionization modes. Data from both systems were treated under untargeted metabolomic strategies using XCMS application and multivariate analysis. Results from the two mass spectrometers differed in the number of detected features, but both led to the same potential marker for the particular testosterone ester misuse. The in-depth study of the MS and MS/MS behavior of this marker allowed for the establishment of 1-cyclopentenoylglycine as a feasible structure. The putative structure was confirmed by comparison with synthesized material. This potential marker seems to come from the metabolism of the cypionic acid release after hydrolysis of the administered ester. Its suitability for doping control has been evaluated.


Assuntos
Cromatografia Líquida de Alta Pressão , Metabolômica , Espectrometria de Massas em Tandem , Testosterona/análise , Urinálise/métodos , Humanos , Masculino , Estrutura Molecular , Padrões de Referência , Testosterona/química , Testosterona/metabolismo
8.
J Pept Sci ; 21(1): 1-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25469748

RESUMO

Peptide hormones represent an emerging class of potential doping agents. Detection of their misuse is difficult due to their short half-life in plasma and rapid elimination. Therefore, investigating their metabolism can improve detectability. Unfortunately, pharmacokinetic studies with human volunteers are often not allowed because of ethical constraints, and therefore alternative models are needed. This study was performed in order to evaluate in vitro models (human liver microsomes and S9 fraction) for the prediction of the metabolism of peptidic doping agents and to compare them with the established models. The peptides that were investigated include desmopressin, TB-500, GHRP-2, GHRP-6, hexarelin, LHRH and leuprolide. Several metabolites were detected for each peptide after incubation with human liver microsomes, S9 fraction, and serum, which all showed endopeptidase and exopeptidase activity. In vitro models from different organs (liver vs. kidney) were compared, but no significant differences were recorded. Deamidation was not observed in any of the models and was therefore evaluated by incubation with α-chymotrypsin. In conclusion, in vitro models are useful tools for forensic and clinical analysts to detect peptidic metabolic markers in biological fluids.


Assuntos
Dopagem Esportivo , Detecção do Abuso de Substâncias , Bioensaio , Quimotripsina/fisiologia , Desamino Arginina Vasopressina/metabolismo , Hormônio Liberador de Gonadotropina/metabolismo , Humanos , Rim/metabolismo , Leuprolida/metabolismo , Fígado/metabolismo , Microssomos Hepáticos/enzimologia , Modelos Biológicos , Oligopeptídeos/metabolismo
9.
Anal Bioanal Chem ; 407(15): 4397-409, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25503937

RESUMO

In order to detect the misuse of endogenous anabolic steroids, doping control laboratories require methods that allow differentiation between endogenous steroids and their synthetic copies. Gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) is capable of measuring the carbon isotope ratio of urinary steroids and this allows differentiation between both. GC-C-IRMS and its application to doping control has evolved a lot during the last decade and so have the World Anti-Doping Agency (WADA) technical documents that describe how GC-C-IRMS should be applied. Especially the WADA technical document of 2014 introduced a number of obligatory quality controls and a fixed methodology that should be used by all the doping control laboratories. This document imposed more uniform methods between the laboratories in order to decrease the interlaboratory standard deviation and acquire similar results for the analysis of the same urine samples. In this paper, 3 years of drug testing data of our GC-C-IRMS method in routine doping control practice is described, with an emphasis on the new WADA technical document and its implementation. Useful data for other doping control laboratories is presented focussing on general method setup, quality control and data collected from routine samples. The paper concentrates on how IRMS results shift or remain similar by switching to the 2014 WADA technical document and gives insight in a straightforward approach to calculate the measurement uncertainty.


Assuntos
Anabolizantes/urina , Cromatografia Gasosa-Espectrometria de Massas/métodos , Esteroides/urina , Detecção do Abuso de Substâncias/métodos , Adulto , Dopagem Esportivo , Feminino , Humanos , Masculino , Controle de Qualidade , Adulto Jovem
10.
Drug Test Anal ; 2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38342098

RESUMO

Nandrolone and its prohormones, including 19-norandrost-4-ene-3,17-dione and 19-norandrost-4-ene-3ß,17ß-diol, are anabolic steroids forbidden at all times in sports according to the World Anti-Doping Code Prohibited List and its metabolite 19-norandrosterone (19NA) is the preferred urinary target compound to identify their abuse. In recent years, an increasing number of 19NA isotope ratio mass spectrometry (IRMS) cases have arisen that, based on the initial testing procedure, were likely to result in an adverse analytical finding but were concluded negative after IRMS analysis. The current study was therefore set up to gain a better insight on the prevalence of nandrolone preparations with endogenous carbon isotope ratio values in Australia. Suitable workplace (non-athlete) urine samples that had previously been reported positive for 19NA were identified and analysed on IRMS. A total of 82% of the samples that were analysed were reported with enriched carbon isotope ratios of 19NA (i.e., 19NA greater than -26‰). This indicates that there is a high prevalence of nandrolone-containing anabolic androgenic steroid preparations in Australia that have 'endogenous' carbon isotope ratios which reduces the ability to identify exogenous nandrolone.

11.
Rapid Commun Mass Spectrom ; 27(18): 2115-26, 2013 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-23943333

RESUMO

RATIONALE: The synthetic cannabinoid JWH-200 (1-[2-(4-morpholinyl)ethyl]-3-(1-naphthoyl)-indole) appeared on the market around 2009. In order to identify markers for misuse of this compound and allow for the development of adequate routine methods, the metabolism of this compound was investigated using two models. METHODS: In vitro and in vivo (both with and without enzymatic hydrolysis) samples were purified by solid-phase extraction and analyzed using liquid chromatography. Electrospray ionization high-resolution Orbitrap mass spectrometry was used for the identification of the metabolites. To confirm the results in vivo, triple-quadrupole mass spectrometry was employed RESULTS: In the in vitro model, using human liver microsomes, 22 metabolites were detected which could be divided into 11 metabolite classes. By using the chimeric mouse model with humanized liver, most of these metabolites were confirmed in vivo. It was found that all metabolites are excreted in urine as conjugates, mostly as glucuronides with varying conjugation rates. CONCLUSIONS: The metabolite formed by consecutive morpholine cleavage and oxidation of the remaining side chain to a carboxylic group was detected in the highest amounts with the longest detection time. Therefore, it is the best candidate metabolite to detect JWH-200 abuse in urine.


Assuntos
Canabinoides/metabolismo , Drogas Ilícitas/metabolismo , Animais , Canabinoides/síntese química , Cromatografia Líquida de Alta Pressão , Humanos , Drogas Ilícitas/síntese química , Camundongos , Camundongos SCID , Microssomos Hepáticos/química , Microssomos Hepáticos/metabolismo , Estrutura Molecular , Espectrometria de Massas em Tandem
12.
Biomed Chromatogr ; 27(2): 240-5, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22740500

RESUMO

The World Anti-Doping Agency (WADA) has recently added desmopressin, a synthetic analogue of the endogenous peptide hormone arginine vasopressin, to the Prohibited List, owing to the potential masking effects of this drug on hematic parameters useful to detect blood doping. A qualitative method for detection of desmopressin in human urine by high-performance liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) has been developed and validated. Desmopressin purification from urine was achieved by means of delipidation with a 60:40 di-isopropyl ether/n-butanol and solid-phase extraction with WCX cartridges. The lower limit of detection was 25 pg/mL. Extraction recovery was determined as 59.3% (SD 29.4), and signal reduction owing to ion suppression was estimated to be 42.7% (SD 12.9). The applicability of the method was proven by the analysis of real urine samples obtained after intravenous, oral and intranasal administration of desmopressin, achieving unambiguous detection of the peptide in all the cases.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Desamino Arginina Vasopressina/urina , Dopagem Esportivo , Espectrometria de Massas em Tandem/métodos , Desamino Arginina Vasopressina/química , Estabilidade de Medicamentos , Humanos , Limite de Detecção , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/métodos
13.
Biomed Chromatogr ; 27(2): 259-66, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22815226

RESUMO

The administration of anabolic steroids is one of the most important issues in doping control and is detectable through a change in the carbon isotopic composition of testosterone and/or its metabolites. Gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS), however, remains a very laborious and expensive technique and substantial amounts of urine are needed to meet the sensitivity requirements of the IRMS. This can be problematic because only a limited amount of urine is available for anti-doping analysis on a broad spectrum of substances. In this work we introduce a new type of injection that increases the sensitivity of GC-C-IRMS by a factor of 13 and reduces the limit of detection, simply by using solvent vent injections instead of splitless injection. This drastically reduces the amount of urine required. On top of that, by only changing the injection technique, the detection parameters of the IRMS are not affected and there is no loss in linearity.


Assuntos
Androgênios/urina , Androstenos/urina , Dopagem Esportivo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Androgênios/química , Androstenos/química , Humanos , Íons/química , Limite de Detecção , Modelos Lineares , Pentanos/química , Reprodutibilidade dos Testes
14.
Drug Test Anal ; 15(11-12): 1344-1355, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36843396

RESUMO

Sulfated metabolites have shown to have potential as long-term markers (LTMs) of anabolic-androgenic steroid (AAS) abuse. The compatibility of gas chromatography-mass spectrometry (GC-MS) with trimethylsilyl (TMS)-derivatives of non-hydrolysed sulfated steroids has been demonstrated, where, after derivatisation, generally, two closely eluting isomers are formed that both have the same molecular ion [M-H2 SO4 ]•+ . Sulfated reference standards are in limited commercial availability, and therefore, the current knowledge of the GC-MS behaviour of these compounds is mainly based on sulfating and analysing the available standard reference material. This procedure can unfortunately not cover all of the current known LTMs as these are often not available as pure substance. Therefore, in theory, some metabolites could be missed as they exhibit alternative behaviour. To investigate the matter, in-house sulfated reference materials that bear resemblance to known sulfated LTMs were analysed on GC-MS in their TMS-derivatised non-hydrolysed state. The (alternative) gas chromatographic and mass spectrometric behaviour was mapped, evaluated and linked to the corresponding steroid structures. Afterwards, using fraction collection, known sulfated LTMs were isolated from excretion urine to confirm the observed findings. The categories that were selected were mono-hydroxy-diones, 17-methyl-3,17-diols and 17-keto-3,16-diols as these are commonly encountered AAS conformations. The ability to predict the GC-MS behaviour of non-hydrolysed sulfated AAS metabolites is the corner stone of finding new metabolites. This knowledge is also essential, for example, for understanding AAS detection analyses, for the mass spectrometric characterization of metabolites of new designer steroids or when one needs to characterize an unknown steroid structure.


Assuntos
Anabolizantes , Dopagem Esportivo , Esteróides Androgênicos Anabolizantes , Anabolizantes/análise , Sulfatos/metabolismo , Congêneres da Testosterona , Esteroides/análise , Detecção do Abuso de Substâncias/métodos
15.
Drug Test Anal ; 15(8): 853-864, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37055939

RESUMO

The frequent detection of anabolic androgenic steroids (AAS) indicates their popularity among rule-breaking athletes. The so called long-term metabolites play a crucial role in their detection, and non-hydrolysed sulphated metabolites have gained renewed interest, as research has demonstrated their extended detection time compared to the more conventional markers (e.g., for metenolone and mesterolone). Their potential has been investigated using liquid and gas chromatography-mass spectrometry (LC- and GC-MS). However, due to their complementary nature, chances are that the most promising metabolite on one technique does not necessarily exhibit the same behaviour on the other and vice versa. Therefore, a comparison was carried out where as a trial model, metenolone, mesterolone and 17α-methyltestosterone were selected and the most likely long-term sulphated metabolites identified on four mass spectrometric instruments. Additionally, using a modified sample preparation procedure, comparison between conventional and non-hydrolysed sulphated metabolites between different GC-MS instruments was also included. When focusing on each individual marker, no cases were observed where a single metabolite provided a superior detection time on all instruments. Furthermore, for each AAS, there were incidences where a metabolite provided the best detection time on one instrument but could only be detected for a shorter period or not at all on other instruments. This demonstrates that metabolite detection windows and hence their added-value as target substance are unique and dependent on the analytical technique and not only on their pharmacokinetic behaviour. Consequently, in each case, a metabolite versus instrument evaluation is needed to maximise the probabilities of detecting doping offences.


Assuntos
Anabolizantes , Dopagem Esportivo , Humanos , Anabolizantes/metabolismo , Esteróides Androgênicos Anabolizantes , Cromatografia Gasosa-Espectrometria de Massas/métodos , Mesterolona/metabolismo , Metenolona , Metiltestosterona/química , Metiltestosterona/metabolismo , Detecção do Abuso de Substâncias/métodos , Sulfatos , Espectrometria de Massas em Tandem/métodos
16.
Rapid Commun Mass Spectrom ; 26(6): 686-92, 2012 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-22328223

RESUMO

RATIONALE: Mechano growth factor (MGF) is a splice variant of insulin-like growth factor that possesses anabolic properties and has not yet been approved for therapeutic use. Nevertheless, it is readily available on the black market. Although the World Anti-Doping Agency (WADA) has banned the use of MGF in sports, no routinely performed methods have been reported for its detection. In this work, two preparations from the black market containing an unknown MGF analogue were characterized. METHODS: Mass spectrometry characterizations of unknown preparations and a reference human MGF were performed on an Orbitrap and a triple quadrupole mass spectrometers after separation by liquid chromatography. High accuracy measurements allowed protein identification from full scan MS data, and low-resolution full scan MS/MS provided further information on fragmentation. RESULTS: HCD scans of the analytes showed the presence of common b series product ions in the black market preparations and the human MGF reference standard, but all the y series ions starting from (y(1))(+) exhibited a difference of 1 m/z unit in nominal mass. This difference was demonstrated to be due to a C-terminal amidation of MGF. High-resolution data demonstrated that the black market products were both C-terminal amidated analogues of human MGF. In addition, low-resolution MS/MS characterization revealed a potentially diagnostic transition (m/z 717.8 → 431.1) for the discrimination of C-amidated MGF from the endogenous form. CONCLUSIONS: Qualitative identification of a MGF C-terminal amidated analogue in two black market products was successfully achieved. This report demonstrates that illegal MGF preparations are commercially available for use as doping agent in sports.


Assuntos
Drogas Ilícitas/química , Fator de Crescimento Insulin-Like I/química , Detecção do Abuso de Substâncias , Amidas/química , Sequência de Aminoácidos , Cromatografia Líquida/métodos , Humanos , Fator de Crescimento Insulin-Like I/isolamento & purificação , Espectrometria de Massas/métodos , Dados de Sequência Molecular , Detecção do Abuso de Substâncias/métodos
17.
Anal Bioanal Chem ; 402(9): 2789-96, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22318696

RESUMO

This work describes a liquid chromatography-electrospray tandem mass spectrometry method for detection of desmopressin in human plasma in the low femtomolar range. Desmopressin is a synthetic analogue of the antidiuretic hormone arginine vasopressin and it might be used by athletes as a masking agent in the framework of blood passport controls. Therefore, it was recently added by the World Anti-Doping Agency to the list of prohibited substances in sport as a masking agent. Mass spectrometry characterization of desmopressin was performed with a high-resolution Orbitrap-based mass spectrometer. Detection of the peptide in the biological matrix was achieved using a triple-quadrupole instrument with an electrospray ionization interface after protein precipitation, weak cation solid-phase extraction and high performance liquid chromatography separation with an octadecyl reverse-phase column. Identification of desmopressin was performed using three product ions, m/z 328.0, m/z 120.0, and m/z 214.0, from the parent ion, m/z 535.5. The extraction efficiency of the method at the limit of detection was estimated as 40% (n = 10), the ion suppression as 5% (n = 10), and the limit of detection was 50 pg/ml (signal-to-noise ratio greater than 3). The selectivity of the method was verified against several endogenous and synthetic desmopressin-related peptides. The performance and the applicability of the method were tested by analysis of clinical samples after administration of desmopressin via intravenous, oral, and intranasal routes. Only after intravenous administration could desmopressin be successfully detected.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Desamino Arginina Vasopressina/sangue , Dopagem Esportivo/prevenção & controle , Humanos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos
18.
Biomed Chromatogr ; 26(11): 1416-35, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22362568

RESUMO

A GC-QqQ-MS method was developed for the detection of over 150 compounds from different classes (steroids, narcotics, stimulants, ß-blockers, ß-2-agonists and hormone antagonists) in a qualitative way. In the quantitative part, the traditional steroid profile with the most important endogenous steroids is expanded with six minor metabolites, which further improves the detection and identification of endogenous steroid abuse. In addition to these, norandrosterone, salbutamol and the major metabolite of cannabis are also quantified. Methods developed for anti-doping purposes should be subjected to the highest level of quality. Here, the addition of a combination of (deuterated) internal standards allows for an accurate quality control of every single step of the methodology: hydrolysis efficiency, derivatization efficiency and microbiological degradation are monitored in every single sample. Additionally, special attention is paid to the relationships between parameters indicating degradation by micro-organisms and the reliability of the steroid profile. The impact of the degradation is studied by evaluation of the quantities and percentages of 5α-androstane-3,17-dione and 5ß-androstane-3,17-dione. The concept of measurement uncertainty was introduced for the evaluation of relative abundances of mass-to-charge ratios and the obtained ranges were compared with the World Anti-Doping Agency regulations on tolerance windows for relative ion intensities. The results indicate that the approaches are similar.


Assuntos
Dopagem Esportivo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Gasosa-Espectrometria de Massas/normas , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/urina , Detecção do Abuso de Substâncias/métodos , Detecção do Abuso de Substâncias/normas , Estabilidade de Medicamentos , Humanos , Preparações Farmacêuticas/química , Preparações Farmacêuticas/metabolismo , Controle de Qualidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Manejo de Espécimes , Urina/microbiologia
19.
Drug Test Anal ; 14(5): 851-863, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-33982451

RESUMO

The most frequently detected substances prohibited by the World Anti-Doping Agency (WADA) belong to the anabolic steroids class. The most challenging compounds among this class are the endogenous anabolic steroids, which are detected by quantitative measurement of testosterone (T) and its metabolites with a so-called "steroid profiling" method. The current steroid profile is based on the concentrations and ratios of the sum of free and glucuronidated steroids. Recently, our group developed a steroid profiling method for the detection of three free steroids and 14 intact steroid conjugates, including both the glucuronic acid conjugated and sulfated fraction. The study aimed at evaluating the long-term stability of steroid conjugate concentrations and ratios, and the influence of different endogenous steroids on this extended steroid profile. A single dose of oral T undecanoate (TU), topical T gel, topical dihydrotestosterone (DHT) gel, and oral dehydroepiandrosterone (DHEA) was administered to six healthy male volunteers. One additional volunteer with a homozygote deletion of the UGT2B17 gene (del/del genotype) received a single topical dose of T gel. An intramuscular dose of TU was administered to another volunteer. To avoid fluctuation of steroid concentrations caused by variations in urinary flow rates, steroid ratios were calculated and evaluated as possible biomarkers for the detection of endogenous steroid abuse with low doses. Overall, sulfates do not have substantial additional value in prolonging detection times for the investigated endogenous steroids and administration doses. The already monitored glucuronides were overall the best markers and were sufficient to detect the administered steroids.


Assuntos
Dopagem Esportivo , Di-Hidrotestosterona/metabolismo , Humanos , Masculino , Esteroides , Detecção do Abuso de Substâncias/métodos , Sulfatos , Testosterona/metabolismo , Congêneres da Testosterona
20.
J Pharm Biomed Anal ; 214: 114726, 2022 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-35298973

RESUMO

This work presents an ultrafiltration-based, validated method for the screening and confirmation of prohibited growth hormone-releasing hormone (GHRH) analogues (sermorelin/CJC-1293, sermorelin metabolite, CJC-1295 and tesamorelin) in urine by nanoLC-HRMS/MS. Sample preparation avoids the use of laborious antibody-based extraction approaches and consists solely of preconcentration by ultrafiltration. Even in the absence of immuno-affinity purification steps, high sensitivity was still ensured as limits of detection between 5 and 25 pg/mL and limits of identification between 25 and 50 pg/mL were established. The robustness of the miniaturized chromatographic setup was evaluated through the injection of 200 + preconcentrated urinary extracts. In a comparison with immuno-affinity purification, enhanced recoveries (59 - 115%) and similar sensitivity were achieved, yet at lower operational costs. Stability experiments showed the importance of the proper handling of urine samples to avoid degradation of these peptide hormones, especially for sermorelin and its metabolite which were found to rapidly degrade at temperatures > 4 °C and pH values < 7 in accordance with earlier studies. Without the need for specific antibodies, this method may be expanded to cover emerging peptide drugs (≥ ~3 kDa), as well as their metabolites in the future to facilitate coverage for this class of prohibited substances.


Assuntos
Dopagem Esportivo , Sermorelina , Anticorpos , Cromatografia de Afinidade/métodos , Hormônio Liberador de Hormônio do Crescimento/análise , Detecção do Abuso de Substâncias/métodos , Ultrafiltração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA