Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
J Synchrotron Radiat ; 31(Pt 3): 485-492, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38630438

RESUMO

Synchrotron light sources can provide the required spatial coherence, stability and control to support the development of advanced lithography at the extreme ultraviolet and soft X-ray wavelengths that are relevant to current and future fabricating technologies. Here an evaluation of the optical performance of the soft X-ray (SXR) beamline of the Australian Synchrotron (AS) and its suitability for developing interference lithography using radiation in the 91.8 eV (13.5 nm) to 300 eV (4.13 nm) range are presented. A comprehensive physical optics model of the APPLE-II undulator source and SXR beamline was constructed to simulate the properties of the illumination at the proposed location of a photomask, as a function of photon energy, collimation and monochromator parameters. The model is validated using a combination of experimental measurements of the photon intensity distribution of the undulator harmonics. It is shown that the undulator harmonics intensity ratio can be accurately measured using an imaging detector and controlled using beamline optics. Finally, the photomask geometric constraints and achievable performance for the limiting case of fully spatially coherent illumination are evaluated.

2.
J Synchrotron Radiat ; 30(Pt 4): 723-738, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37343017

RESUMO

The ability to utilize a hybrid-photon-counting detector to its full potential can significantly influence data quality, data collection speed, as well as development of elaborate data acquisition schemes. This paper facilitates the optimal use of EIGER2 detectors by providing theory and practical advice on (i) the relation between detector design, technical specifications and operating modes, (ii) the use of corrections and calibrations, and (iii) new acquisition features: a double-gating mode, 8-bit readout mode for increasing temporal resolution, and lines region-of-interest readout mode for frame rates up to 98 kHz. Examples of the implementation and application of EIGER2 at several synchrotron sources (ESRF, PETRA III/DESY, ELETTRA, AS/ANSTO) are presented: high accuracy of high-throughput data in serial crystallography using hard X-rays; suppressing higher harmonics of undulator radiation, improving peak shapes, increasing data collection speed in powder X-ray diffraction; faster ptychography scans; and cleaner and faster pump-and-probe experiments.


Assuntos
Fótons , Síncrotrons , Raios X , Radiografia , Difração de Raios X
3.
J Synchrotron Radiat ; 29(Pt 2): 480-487, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35254312

RESUMO

Over the last decade ptychography has progressed rapidly from a specialist ultramicroscopy technique into a mature method accessible to non-expert users. However, to improve scientific value ptychography data must reconstruct reliably, with high image quality and at no cost to other correlative methods. Presented here is the implementation of high-speed ptychography used at the Australian Synchrotron on the XFM beamline, which includes a free-run data collection mode where dead time is eliminated and the scan time is optimized. It is shown that free-run data collection is viable for fast and high-quality ptychography by demonstrating extremely high data rate acquisition covering areas up to 352 000 µm2 at up to 140 µm2 s-1, with 13× spatial resolution enhancement compared with the beam size. With these improvements, ptychography at velocities up to 250 µm s-1 is approaching speeds compatible with fast-scanning X-ray fluorescence microscopy. The combination of these methods provides morphological context for elemental and chemical information, enabling unique scientific outcomes.


Assuntos
Microscopia , Síncrotrons , Austrália , Microscopia/métodos
4.
J Synchrotron Radiat ; 29(Pt 4): 939-946, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35787559

RESUMO

Characterizing the properties of X-ray free-electron laser (XFEL) sources is a critical step for optimization of performance and experiment planning. The recent availability of MHz XFELs has opened up a range of new opportunities for novel experiments but also highlighted the need for systematic measurements of the source properties. Here, MHz-enabled beam imaging diagnostics developed for the SPB/SFX instrument at the European XFEL are exploited to measure the shot-to-shot intensity statistics of X-ray pulses. The ability to record pulse-integrated two-dimensional transverse intensity measurements at multiple planes along an XFEL beamline at MHz rates yields an improved understanding of the shot-to-shot photon beam intensity variations. These variations can play a critical role, for example, in determining the outcome of single-particle imaging experiments and other experiments that are sensitive to the transverse profile of the incident beam. It is observed that shot-to-shot variations in the statistical properties of a recorded ensemble of radiant intensity distributions are sensitive to changes in electron beam current density. These changes typically occur during pulse-distribution to the instrument and are currently not accounted for by the existing suite of imaging diagnostics. Modulations of the electron beam orbit in the accelerator are observed to induce a time-dependence in the statistics of individual pulses - this is demonstrated by applying radio-frequency trajectory tilts to electron bunch-trains delivered to the instrument. We discuss how these modifications of the beam trajectory might be used to modify the statistical properties of the source and potential future applications.

5.
Opt Express ; 28(24): 36862-36872, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33379770

RESUMO

Dynamic coherent diffractive imaging (CDI) reveals the fine details of structural, chemical, and biological processes occurring at the nanoscale but imposes strict constraints on the object distribution and illumination. Ptychographic CDI relaxes these constraints by exploiting redundant information in data obtained from overlapping regions of an object, but its time resolution is inherently limited. We have extended ptychographic redundancy into the spatiotemporal domain in dynamic CDI, automatically identifying redundant information in time-series coherent diffraction data obtained from dynamic systems. Simulated synchrotron experiments show that high spatiotemporal resolution is achieved without a priori knowledge of the object or its dynamics.

6.
J Synchrotron Radiat ; 23(Pt 5): 1151-7, 2016 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-27577770

RESUMO

Owing to its extreme sensitivity, quantitative mapping of elemental distributions via X-ray fluorescence microscopy (XFM) has become a key microanalytical technique. The recent realisation of scanning X-ray diffraction microscopy (SXDM) meanwhile provides an avenue for quantitative super-resolved ultra-structural visualization. The similarity of their experimental geometries indicates excellent prospects for simultaneous acquisition. Here, in both step- and fly-scanning modes, robust, simultaneous XFM-SXDM is demonstrated.

7.
IUCrJ ; 10(Pt 6): 708-719, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37782462

RESUMO

Many coherent imaging applications that utilize ultrafast X-ray free-electron laser (XFEL) radiation pulses are highly sensitive to fluctuations in the shot-to-shot statistical properties of the source. Understanding and modelling these fluctuations are key to successful experiment planning and necessary to maximize the potential of XFEL facilities. Current models of XFEL radiation and their shot-to-shot statistics are based on theoretical descriptions of the source and are limited in their ability to capture the shot-to-shot intensity fluctuations observed experimentally. The lack of accurate temporal statistics in simulations that utilize these models is a significant barrier to optimizing and interpreting data from XFEL coherent diffraction experiments. Presented here is a phenomenological model of XFEL radiation that is capable of capturing the shot-to-shot statistics observed experimentally using a simple time-dependent approximation of the pulse wavefront. The model is applied to reproduce non-stationary shot-to-shot intensity fluctuations observed at the European XFEL, whilst accurately representing the single-shot properties predicted by FEL theory. Compared with previous models, this approach provides a simple, robust and computationally inexpensive method of generating statistical representations of XFEL radiation.

8.
Opt Express ; 20(21): 23361-6, 2012 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-23188299

RESUMO

We describe a direct quantitative phase reconstruction approach using an X-ray laboratory-based source. Using a single phase-contrast image from each tomographic projection we show that it is possible to modify the filter term in a filtered back projection reconstruction to take account of the broad spectrum from a laboratory source. The accessibility of conventional X-ray laboratory sources makes this method very useful for quantitative phase imaging of homogeneous and weakly absorbing objects.


Assuntos
Aumento da Imagem/instrumentação , Refratometria/instrumentação , Tomografia por Raios X/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
9.
J Appl Crystallogr ; 55(Pt 3): 479-483, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35719300

RESUMO

X-ray coherent diffractive imaging (CDI) techniques have been applied with widespread impact to study nanoscale material properties. New fast framing detectors may reveal dynamics that occur at millisecond timescales. This work demonstrates by simulation that kilohertz synchrotron CDI is possible, by making use of redundant information from static parts of the image field. Reconstruction ambiguities are strongly suppressed by applying a spatio-temporal constraint, obviating the need for slower methods of introducing diversity such as ptychography. The relationship between image fidelity and time resolution is investigated and shows that dynamics an order of magnitude faster can be reconstructed, compared with conventional CDI.

10.
Chem Commun (Camb) ; 55(8): 1052-1055, 2019 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-30608504

RESUMO

Biological X-ray fluorescence microscopy (XFM) is an important tool for determining quantitative distributions of bioinorganics and essential trace elements. Here we present a new analysis approach for rapid nanoscale ptychographic imaging and simultaneous chemical mapping of large radiation sensitive specimens without image degradation associated with probe evolution.

11.
Sci Rep ; 4: 6796, 2014 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-25348877

RESUMO

Isolating compositional information in biological X-ray imaging can be problematic as such information is conflated with thickness and density variations when viewing in projection through a sample. We demonstrate an effective method for identifying variations in material composition by simultaneously using the quantitative phase and magnitude images provided through soft X-ray ptychography. Using this approach we show significantly increased contrast and improved reliability of the identification of intracellular features from uncharacterised samples. While demonstrated for X-ray ptychography, this method is immediately applicable to electron and optical microscopy methods where the complex transmission function of the sample is recovered.


Assuntos
Rastreamento de Células/métodos , Microscopia/métodos , Imagem Molecular , Animais , Meios de Contraste/química , Elétrons , Fibroblastos/ultraestrutura , Camundongos , Raios X
12.
Ultramicroscopy ; 143: 88-92, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24209602

RESUMO

Phase-diverse X-ray coherent diffractive imaging (CDI) provides a route to high sensitivity and spatial resolution with moderate radiation dose. It also provides a robust solution to the well-known phase-problem, making on-line image reconstruction feasible. Here we apply phase-diverse CDI to a cellular sample, obtaining images of an erythrocyte infected by the sexual stage of the malaria parasite, Plasmodium falciparum, with a radiation dose significantly lower than the lowest dose previously reported for cellular imaging using CDI. The high sensitivity and resolution allow key biological features to be identified within intact cells, providing complementary information to optical and electron microscopy. This high throughput method could be used for fast tomographic imaging, or to generate multiple replicates in two-dimensions of hydrated biological systems without freezing or fixing. This work demonstrates that phase-diverse CDI is a valuable complementary imaging method for the biological sciences and ready for immediate application.


Assuntos
Diagnóstico por Imagem/métodos , Malária Falciparum/diagnóstico , Parasitos/ultraestrutura , Plasmodium falciparum/ultraestrutura , Difração de Raios X/métodos , Animais , Eritrócitos/parasitologia , Processamento de Imagem Assistida por Computador/métodos , Microscopia Eletrônica/métodos , Imagem Óptica/métodos , Sensibilidade e Especificidade
13.
Sci Rep ; 3: 2288, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23887204

RESUMO

X-ray tomography can provide structural information of whole cells in close to their native state. Radiation-induced damage, however, imposes a practical limit to image resolution, and as such, a choice between damage, image contrast, and image resolution must be made. New coherent diffractive imaging techniques, such Fresnel Coherent Diffractive Imaging (FCDI), allows quantitative phase information with exceptional dose efficiency, high contrast, and nano-scale resolution. Here we present three-dimensional quantitative images of a whole eukaryotic cell by FCDI at a spatial resolution below 70 nm with sufficient phase contrast to distinguish major cellular components. From our data, we estimate that the minimum dose required for a similar resolution is close to that predicted by the Rose criterion, considerably below accepted estimates of the maximum dose a frozen-hydrated cell can tolerate. Based on the dose efficiency, contrast, and resolution achieved, we expect this technique will find immediate applications in tomographic cellular characterisation.


Assuntos
Análise de Célula Única/métodos , Tomografia Computadorizada por Raios X/métodos , Eritrócitos/citologia , Eritrócitos/parasitologia , Humanos
14.
J Phys Condens Matter ; 22(9): 092201, 2010 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-21389410

RESUMO

We have measured the correlated electron pair emission from a Cu(001) surface by both direct and core-resonant channels upon excitation with linearly polarized photons of energy far above the 3p threshold. As expected for a single-step process mediated by electron correlation in the initial and final states, the two electrons emitted by the direct channel continuously share the sum of the energy available to them. The core-resonant channel is often considered in terms of successive and independent steps of photoexcitation and Auger decay. However, electron pairs emitted by the core-resonant channel also share their energy continuously to jointly conserve the energy of the complete process. By detecting the electron pairs in parallel over a wide range of energy, evidence of the core-resonant double photoemission proceeding by a coherent single-step process is most strikingly manifested by a continuum of correlated electron pairs with a sum energy characteristic of the process but for which the individual electrons have arbitrary energies and cannot meaningfully be distinguished as a photoelectron or Auger electron.

15.
Langmuir ; 24(15): 7897-905, 2008 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-18616223

RESUMO

Fluoropolymer plasma coatings have been investigated for application as stent coatings due to their chemical stability, conformability, and hydrophobic properties. The challenge resides in the capacity for these coatings to remain adherent, stable, and cohesive after the in vivo stent expansion, which can generate local plastic deformation of up to 25%. Plasma-coated samples have been prepared by a multistep process on 316L stainless steel substrates, and some coated samples were plastically deformed to mimic a stent expansion. Analyses were then performed by X-ray photoelectron spectroscopy (XPS), X-ray photoelectron emission microscopy (X-PEEM), and time-of-flight secondary ion mass spectrometry (TOF-SIMS) to determine the chemical and physical effects of such a deformation on both the coating and the interfacial region. While XPS analyses always showed a continuous coating with no significant effect of the deformation, TOF-SIMS and near-edge X-ray absorption fine structure (derived from X-PEEM) data indicated the presence of a certain density of porosity and pinholes in all coatings as well as sparse fissures and molecular fragmentation in the deformed ones. The smallness of the area fraction affected by the defects and the subtlety of the chemical changes could only be evidenced through the higher chemical sensitivity of these latter techniques.


Assuntos
Compostos de Flúor/química , Microscopia Eletrônica/métodos , Polímeros/química , Espectrometria de Massa de Íon Secundário/métodos , Stents , Raios X , Absorção , Fatores de Tempo
16.
Nanotechnol Sci Appl ; 1: 33-44, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-24198459

RESUMO

This study reports the adhesion behavior of two bacterial species, Vibrio fischeri and Escherichia coli, to the photoresistant poly(tert-butyl methacrylate) (P(tBMA)) polymer surface. The data has demonstrated that ultraviolet irradiation of P(tBMA) was able to provide control over bacterial adhesion tendencies. Following photolithography, several of the surface characteristics of P(tBMA) were found to be altered. Atomic force microscopy analysis indicated that photolithographically modified P(tBMA) (henceforth termed 'modified polymer') appeared as a 'nanosmooth' surface with an average surface roughness of 1.6 nm. Although confocal laser scanning microscopy and scanning electron microscopy analysis clearly demonstrated that V. fischeri and E. coli presented largely different patterns of attachment in order to adhere to the same surfaces, both species exhibited a greater adhesion propensity towards the 'nanosmooth' surface. The adhesion of both species to the modified polymer surface appeared to be facilitated by an elevated production of extracellular polymeric substances when in contact with the substrate.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA