Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Neuroeng Rehabil ; 21(1): 21, 2024 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-38331908

RESUMO

BACKGROUND: Lack of standardized assessments that explicitly quantify performance during prosthetic grip selection poses difficulty determining whether efforts to improve the design of multi-grip hands and their control approaches are successful. In this study, we developed and validated a novel assessment of multi-grip prosthetic performance: The Coffee Task. METHODS: Individuals without limb loss completed the Box and Block Test and two versions of the Coffee Task - Continuous and Segmented - with a myoelectric prosthetic emulator. On different days, participants selected prosthetic grips using pattern recognition and trigger control. Outcomes of the Continuous and Segmented Coffee Task were completion time and number of errors, respectively. Two independent raters assessed outcomes of the Coffee Task using video recordings to determine inter-rater reliability. Known-group validity was assessed by comparing outcomes with the emulator to those with an intact limb. Convergent validity was assessed through the correlation of the Coffee Task outcomes and those of the Box and Blocks Test. Responsiveness to changes with practice and control approach were assessed using the standardized response mean (SRM). RESULTS: Inter-rater reliability was high for both versions of the Coffee Task (Intra-class coefficient > 0.981). Coffee Task outcomes were moderately correlated with the Box and Blocks outcomes (|r| ≥ 0.412, p ≤ 0.007). Participants completed the Coffee Task faster with their intact limb than with the emulator (p < 0.001). Both versions of the Coffee Task were responsive to changes with training (SRM ≥ 0.81) but not control approach (SRM ≤ 0.12). CONCLUSIONS: The Coffee Task is reliable, has good known-group and convergent validity, and is responsive to changes due to practice. Future work should assess whether the Coffee Task is feasible and reliable for people with upper limb loss who use multi-grip prostheses.


Assuntos
Membros Artificiais , Café , Humanos , Reprodutibilidade dos Testes , Extremidade Superior , Força da Mão
2.
IEEE Trans Robot ; 38(5): 2841-2857, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37193351

RESUMO

Currently available prosthetic hands are capable of actuating anywhere from five to 30 degrees of freedom (DOF). However, grasp control of these devices remains unintuitive and cumbersome. To address this issue, we propose directly extracting finger commands from the neuromuscular system. Two persons with transradial amputations had bipolar electrodes implanted into regenerative peripheral nerve interfaces (RPNIs) and residual innervated muscles. The implanted electrodes recorded local electromyography with large signal amplitudes. In a series of single-day experiments, participants used a high speed movement classifier to control a virtual prosthetic hand in real-time. Both participants transitioned between 10 pseudo-randomly cued individual finger and wrist postures with an average success rate of 94.7% and trial latency of 255 ms. When the set was reduced to five grasp postures, metrics improved to 100% success and 135 ms trial latency. Performance remained stable across untrained static arm positions while supporting the weight of the prosthesis. Participants also used the high speed classifier to switch between robotic prosthetic grips and complete a functional performance assessment. These results demonstrate that pattern recognition systems can use intramuscular electrodes and RPNIs for fast and accurate prosthetic grasp control.

3.
Semin Plast Surg ; 38(1): 10-18, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38495064

RESUMO

Limb amputations can be devastating and significantly affect an individual's independence, leading to functional and psychosocial challenges in nearly 2 million people in the United States alone. Over the past decade, robotic devices driven by neural signals such as neuroprostheses have shown great potential to restore the lost function of limbs, allowing amputees to regain movement and sensation. However, current neuroprosthetic interfaces have challenges in both signal quality and long-term stability. To overcome these limitations and work toward creating bionic limbs, the Neuromuscular Laboratory at University of Michigan Plastic Surgery has developed the Regenerative Peripheral Nerve Interface (RPNI). This surgical construct embeds a transected peripheral nerve into a free muscle graft, effectively amplifying small peripheral nerve signals to provide enhanced control signals for a neuroprosthetic limb. Furthermore, the RPNI has the potential to provide sensory feedback to the user and facilitate neuroprosthesis embodiment. This review focuses on the animal studies and clinical trials of the RPNI to recapitulate the promising trajectory toward neurobionics where the boundary between an artificial device and the human body becomes indistinct. This paper also sheds light on the prospects of the improvement and dissemination of the RPNI technology.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38145529

RESUMO

Individuals with upper limb loss lack sensation of the missing hand, which can negatively impact their daily function. Several groups have attempted to restore this sensation through electrical stimulation of residual nerves. The purpose of this study was to explore the utility of regenerative peripheral nerve interfaces (RPNIs) in eliciting referred sensation. In four participants with upper limb loss, we characterized the quality and location of sensation elicited through electrical stimulation of RPNIs over time. We also measured functional stimulation ranges (sensory perception and discomfort thresholds), sensitivity to changes in stimulation amplitude, and ability to differentiate objects of different stiffness and sizes. Over a period of up to 54 months, stimulation of RPNIs elicited sensations that were consistent in quality (e.g. tingling, kinesthesia) and were perceived in the missing hand and forearm. The location of elicited sensation was partially-stable to stable in 13 of 14 RPNIs. For 5 of 7 RPNIs tested, participants demonstrated a sensitivity to changes in stimulation amplitude, with an average just noticeable difference of 45 nC. In a case study, one participant was provided RPNI stimulation proportional to prosthetic grip force. She identified four objects of different sizes and stiffness with 56% accuracy with stimulation alone and 100% accuracy when stimulation was combined with visual feedback of hand position. Collectively, these experiments suggest that RPNIs have the potential to be used in future bi-directional prosthetic systems.


Assuntos
Membros Artificiais , Nervos Periféricos , Feminino , Humanos , Nervos Periféricos/fisiologia , Extremidade Superior , Sensação , Mãos , Estimulação Elétrica
5.
J Neural Eng ; 20(2)2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-37023743

RESUMO

Objective.Extracting signals directly from the motor system poses challenges in obtaining both high amplitude and sustainable signals for upper-limb neuroprosthetic control. To translate neural interfaces into the clinical space, these interfaces must provide consistent signals and prosthetic performance.Approach.Previously, we have demonstrated that the Regenerative Peripheral Nerve Interface (RPNI) is a biologically stable, bioamplifier of efferent motor action potentials. Here, we assessed the signal reliability from electrodes surgically implanted in RPNIs and residual innervated muscles in humans for long-term prosthetic control.Main results.RPNI signal quality, measured as signal-to-noise ratio, remained greater than 15 for up to 276 and 1054 d in participant 1 (P1), and participant 2 (P2), respectively. Electromyography from both RPNIs and residual muscles was used to decode finger and grasp movements. Though signal amplitude varied between sessions, P2 maintained real-time prosthetic performance above 94% accuracy for 604 d without recalibration. Additionally, P2 completed a real-world multi-sequence coffee task with 99% accuracy for 611 d without recalibration.Significance.This study demonstrates the potential of RPNIs and implanted EMG electrodes as a long-term interface for enhanced prosthetic control.


Assuntos
Membros Artificiais , Nervos Periféricos , Humanos , Reprodutibilidade dos Testes , Nervos Periféricos/fisiologia , Extremidade Superior , Eletromiografia/métodos , Eletrodos Implantados , Eletrodos
6.
IEEE Int Conf Rehabil Robot ; 2022: 1-6, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36176116

RESUMO

Current prosthetic limbs offer little to no sensory feedback. Developments in peripheral nerve interfaces provide opportunities to restore some level of tactile feedback that is referred to the prosthetic limb. One such method is a Regenerative Peripheral Nerve Interface (RPNI), composed of a muscle graft wrapped around a free nerve ending. Here, we characterize perception and discomfort thresholds, as well as sensitivity to stimulation through two-alternative forced choice discrimination tasks. One person with transradial amputation who had one RPNI constructed from the median nerve and two constructed from the ulnar nerve participated. Average perception thresholds across all RPNIs were between 950 and 1120 nC with variance of less than 350 nC over a 36-month period. Discomfort thresholds were from 3880 nC to 9770 nC across all RPNIs. The just noticeable difference for the Median RPNI was 520 nC, larger than either the Ulnar-1 or Ulnar-2 RPNIs (210 nC, 470 nC, respectively). We also calculated Weber fractions to compare sensitivity between different RPNIs and relate our results to previous studies. Weber fractions for each of the Median, Ulnar-1, and Ulnar-2 RPNIs were 0.134, 0.088, 0.087, respectively. This work is the first to quantify the functional stimulation range and sensitivity of RPNIs in a human participant. Future work will focus on characterizing RPNI sensation in additional individuals to determine if these findings are generalizable to the amputee population.


Assuntos
Amputados , Membros Artificiais , Retroalimentação Sensorial , Humanos , Regeneração Nervosa/fisiologia , Nervos Periféricos/fisiologia , Limiar Sensorial
7.
J Neural Eng ; 19(6)2022 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-36317254

RESUMO

Objective.Advanced myoelectric hands enable users to select from multiple functional grasps. Current methods for controlling these hands are unintuitive and require frequent recalibration. This case study assessed the performance of tasks involving grasp selection, object interaction, and dynamic postural changes using intramuscular electrodes with regenerative peripheral nerve interfaces (RPNIs) and residual muscles.Approach.One female with unilateral transradial amputation participated in a series of experiments to compare the performance of grasp selection controllers with RPNIs and intramuscular control signals with controllers using surface electrodes. These experiments included a virtual grasp-matching task with and without a concurrent cognitive task and physical tasks with a prosthesis including standardized functional assessments and a functional assessment where the individual made a cup of coffee ('Coffee Task') that required grasp transitions.Main results.In the virtual environment, the participant was able to select between four functional grasps with higher accuracy using the RPNI controller (92.5%) compared to surface controllers (81.9%). With the concurrent cognitive task, performance of the virtual task was more consistent with RPNI controllers (reduced accuracy by 1.1%) compared to with surface controllers (4.8%). When RPNI signals were excluded from the controller with intramuscular electromyography (i.e. residual muscles only), grasp selection accuracy decreased by up to 24%. The participant completed the Coffee Task with 11.7% longer completion time with the surface controller than with the RPNI controller. She also completed the Coffee Task with 11 fewer transition errors out of a maximum of 25 total errors when using the RPNI controller compared to surface controller.Significance.The use of RPNI signals in concert with residual muscles and intramuscular electrodes can improve grasp selection accuracy in both virtual and physical environments. This approach yielded consistent performance without recalibration needs while reducing cognitive load associated with pattern recognition for myoelectric control (clinical trial registration number NCT03260400).


Assuntos
Membros Artificiais , Músculo Esquelético , Feminino , Humanos , Eletrodos , Eletromiografia/métodos , Mãos/fisiologia , Força da Mão , Músculo Esquelético/fisiologia , Nervos Periféricos/fisiologia
8.
Plast Reconstr Surg ; 149(6): 1149e-1154e, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35404335

RESUMO

SUMMARY: Without meaningful and intuitive sensory feedback, even the most advanced prosthetic limbs remain insensate and impose an enormous cognitive burden during use. The regenerative peripheral nerve interface can serve as a novel bidirectional motor and sensory neuroprosthetic interface. In previous human studies, regenerative peripheral nerve interfaces demonstrated stable high-amplitude motor electromyography signals with excellent signal-to-noise ratio for prosthetic control. In addition, they can treat and prevent postamputation pain by mitigating neuroma formation. In this study, the authors investigated whether electrical stimulation applied to regenerative peripheral nerve interfaces could produce appreciable proprioceptive and/or tactile sensations in two participants with upper limb amputations. Stimulation of the interfaces resulted in both participants reporting proprioceptive sensations in the phantom hand. Specifically, stimulation of participant 1's median nerve regenerative peripheral nerve interface activated a flexion sensation in the thumb or index finger, whereas stimulation of the ulnar nerve interface evoked a flexion sensation of the ring or small finger. Likewise, stimulation of one of participant 2's ulnar nerve interfaces produced a sensation of flexion at the ring finger distal interphalangeal joint. In addition, stimulation of participant 2's other ulnar nerve interface and the median nerve interface resulted in perceived cutaneous sensations that corresponded to each nerve's respective dermatome. These results suggest that regenerative peripheral nerve interfaces have the potential to restore proprioceptive and cutaneous sensory feedback that could significantly improve prosthesis use and embodiment.


Assuntos
Membros Artificiais , Amputação Cirúrgica , Humanos , Nervos Periféricos/fisiologia , Propriocepção , Extremidade Superior/cirurgia
9.
Hand Clin ; 37(3): 391-399, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34253312

RESUMO

Brain-machine interfaces (BMI) are being developed to restore upper limb function for persons with spinal cord injury or other motor degenerative conditions. BMI and implantable sensors for myoelectric prostheses directly extract information from the central or peripheral nervous system to provide users with high fidelity control of their prosthetic device. Control algorithms have been highly transferable between the 2 technologies but also face common issues. In this review of the current state of the art in each field, the authors point out similarities and differences between the 2 technologies that may guide the implementation of common solutions to these challenges.


Assuntos
Membros Artificiais , Interfaces Cérebro-Computador , Traumatismos da Medula Espinal , Algoritmos , Mãos , Humanos , Extremidade Superior
10.
Neuron ; 109(19): 3164-3177.e8, 2021 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-34499856

RESUMO

Modern brain-machine interfaces can return function to people with paralysis, but current upper extremity brain-machine interfaces are unable to reproduce control of individuated finger movements. Here, for the first time, we present a real-time, high-speed, linear brain-machine interface in nonhuman primates that utilizes intracortical neural signals to bridge this gap. We created a non-prehensile task that systematically individuates two finger groups, the index finger and the middle-ring-small fingers combined. During online brain control, the ReFIT Kalman filter could predict individuated finger group movements with high performance. Next, training ridge regression decoders with individual movements was sufficient to predict untrained combined movements and vice versa. Finally, we compared the postural and movement tuning of finger-related cortical activity to find that individual cortical units simultaneously encode multiple behavioral dimensions. Our results suggest that linear decoders may be sufficient for brain-machine interfaces to execute high-dimensional tasks with the performance levels required for naturalistic neural prostheses.


Assuntos
Interfaces Cérebro-Computador , Dedos/fisiologia , Movimento/fisiologia , Próteses Neurais , Algoritmos , Animais , Fenômenos Biomecânicos , Eletrodos Implantados , Dedos/inervação , Previsões , Modelos Lineares , Macaca mulatta , Masculino , Microeletrodos , Córtex Motor/fisiologia , Postura/fisiologia , Desenho de Prótese , Desempenho Psicomotor
11.
Nat Biomed Eng ; 4(10): 973-983, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32719512

RESUMO

The large power requirement of current brain-machine interfaces is a major hindrance to their clinical translation. In basic behavioural tasks, the downsampled magnitude of the 300-1,000 Hz band of spiking activity can predict movement similarly to the threshold crossing rate (TCR) at 30 kilo-samples per second. However, the relationship between such a spiking-band power (SBP) and neural activity remains unclear, as does the capability of using the SBP to decode complicated behaviour. By using simulations of recordings of neural activity, here we show that the SBP is dominated by local single-unit spikes with spatial specificity comparable to or better than that of the TCR, and that the SBP correlates better with the firing rates of lower signal-to-noise-ratio units than the TCR. With non-human primates, in an online task involving the one-dimensional decoding of the movement of finger groups and in an offline two-dimensional cursor-control task, the SBP performed equally well or better than the TCR. The SBP may enhance the decoding performance of neural interfaces while enabling substantial cuts in power consumption.


Assuntos
Interfaces Cérebro-Computador , Córtex Motor/fisiologia , Neurônios/fisiologia , Animais , Dedos , Macaca mulatta , Masculino , Microeletrodos , Próteses e Implantes , Ratos Long-Evans , Razão Sinal-Ruído
12.
Sci Transl Med ; 12(533)2020 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-32132217

RESUMO

Peripheral nerves provide a promising source of motor control signals for neuroprosthetic devices. Unfortunately, the clinical utility of current peripheral nerve interfaces is limited by signal amplitude and stability. Here, we showed that the regenerative peripheral nerve interface (RPNI) serves as a biologically stable bioamplifier of efferent motor action potentials with long-term stability in upper limb amputees. Ultrasound assessments of RPNIs revealed prominent contractions during phantom finger flexion, confirming functional reinnervation of the RPNIs in two patients. The RPNIs in two additional patients produced electromyography signals with large signal-to-noise ratios. Using these RPNI signals, subjects successfully controlled a hand prosthesis in real-time up to 300 days without control algorithm recalibration. RPNIs show potential in enhancing prosthesis control for people with upper limb loss.


Assuntos
Amputados , Membros Artificiais , Eletromiografia , Mãos , Humanos , Nervos Periféricos , Extremidade Superior
13.
Front Neurosci ; 12: 751, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30455621

RESUMO

Objective: To date, many brain-machine interface (BMI) studies have developed decoding algorithms for neuroprostheses that provide users with precise control of upper arm reaches with some limited grasping capabilities. However, comparatively few have focused on quantifying the performance of precise finger control. Here we expand upon this work by investigating online control of individual finger groups. Approach: We have developed a novel training manipulandum for non-human primate (NHP) studies to isolate the movements of two specific finger groups: index and middle-ring-pinkie (MRP) fingers. We use this device in combination with the ReFIT (Recalibrated Feedback Intention-Trained) Kalman filter to decode the position of each finger group during a single degree of freedom task in two rhesus macaques with Utah arrays in motor cortex. The ReFIT Kalman filter uses a two-stage training approach that improves online control of upper arm tasks with substantial reductions in orbiting time, thus making it a logical first choice for precise finger control. Results: Both animals were able to reliably acquire fingertip targets with both index and MRP fingers, which they did in blocks of finger group specific trials. Decoding from motor signals online, the ReFIT Kalman filter reliably outperformed the standard Kalman filter, measured by bit rate, across all tested finger groups and movements by 31.0 and 35.2%. These decoders were robust when the manipulandum was removed during online control. While index finger movements and middle-ring-pinkie finger movements could be differentiated from each other with 81.7% accuracy across both subjects, the linear Kalman filter was not sufficient for decoding both finger groups together due to significant unwanted movement in the stationary finger, potentially due to co-contraction. Significance: To our knowledge, this is the first systematic and biomimetic separation of digits for continuous online decoding in a NHP as well as the first demonstration of the ReFIT Kalman filter improving the performance of precise finger decoding. These results suggest that novel nonlinear approaches, apparently not necessary for center out reaches or gross hand motions, may be necessary to achieve independent and precise control of individual fingers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA