RESUMO
PURPOSE: To present a constrained optimal-control (OC) framework for designing large-flip-angle parallel-transmit (pTx) pulses satisfying hardware peak-power as well as regulatory local and global specific-absorption-rate (SAR) limits. The application is 2D and 3D spatial-selective 90° and 180° pulses. THEORY AND METHODS: The OC gradient-ascent-pulse-engineering method with exact gradients and the limited-memory Broyden-Fletcher-Goldfarb-Shanno method is proposed. Local SAR is constrained by the virtual-observation-points method. Two numerical models facilitated the optimizations, a torso at 3 T and a head at 7 T, both in eight-channel pTx coils and acceleration-factors up to 4. RESULTS: The proposed approach yielded excellent flip-angle distributions. Enforcing the local-SAR constraint, as opposed to peak power alone, reduced the local SAR 7 and 5-fold with the 2D torso excitation and inversion pulse, respectively. The root-mean-square errors of the magnetization profiles increased less than 5% with the acceleration factor of 4. CONCLUSION: A local and global SAR, and peak-power constrained OC large-flip-angle pTx pulse design was presented, and numerically validated for 2D and 3D spatial-selective 90° and 180° pulses at 3 T and 7 T. Magn Reson Med 77:374-384, 2017. © 2015 Wiley Periodicals, Inc.
Assuntos
Imageamento por Ressonância Magnética/métodos , Absorção Fisico-Química , Adulto , Algoritmos , Simulação por Computador , Cabeça/diagnóstico por imagem , Humanos , Masculino , Imagens de Fantasmas , Tronco/diagnóstico por imagemRESUMO
OBJECTIVE: Ultrahigh field MRI provides great opportunities for medical diagnostics and research. However, ultrahigh field MRI also brings challenges, such as larger magnetic susceptibility induced field changes. Parallel-transmit radio-frequency pulses can ameliorate these complications while performing advanced tasks in routine applications. To address one class of such pulses, we propose an optimal-control algorithm as a tool for designing advanced multi-dimensional, large flip-angle, radio-frequency pulses. We contrast initial conditions, constraints, and field correction abilities against increasing pulse trajectory acceleration factors. MATERIALS AND METHODS: On an 8-channel 7T system, we demonstrate the quasi-Newton algorithm with pulse designs for reduced field-of-view imaging with an oil phantom and in vivo with scans of the human brain stem. We used echo-planar imaging with 2D spatial-selective pulses. Pulses are computed sufficiently rapid for routine applications. RESULTS: Our dataset was quantitatively analyzed with the conventional mean-square-error metric and the structural-similarity index from image processing. Analysis of both full and reduced field-of-view scans benefit from utilizing both complementary measures. CONCLUSION: We obtained excellent outer-volume suppression with our proposed method, thus enabling reduced field-of-view imaging using pulse trajectory acceleration factors up to 4.
Assuntos
Tronco Encefálico/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Ondas de Rádio , Algoritmos , Mapeamento Encefálico , Tronco Encefálico/patologia , Imagem Ecoplanar , Humanos , Aumento da Imagem , Modelos Estatísticos , Imagens de Fantasmas , Reprodutibilidade dos TestesRESUMO
A mobile, low-field nuclear magnetic resonance (NMR) sensor for onboard, inline detection of catalytic fines in fuel oil in the shipping industry is presented as an alternative to onshore laboratory measurements. Catalytic fines (called cat fines) are aluminosilicate zeolite catalysts utilized in the oil cracking process at refineries. When present in fuel oil, cat fines cause abrasive wear of engine parts and may ultimately lead to engine breakdown with large economical consequences, thereby motivating methods for inline measurements. Here, we report on a robust, mobile, and low-cost (27)Al NMR sensor for continuous online measurement of the level of catalytic fines in fuel oil onboard ships. The sensor enables accurate measurements of aluminum (catalytic fines) in ppm concentrations in good agreement with commercial laboratory reference measurements.
Assuntos
Óleos Combustíveis/análise , Espectroscopia de Ressonância Magnética/instrumentação , CatáliseRESUMO
The use of increasingly strong magnetic fields in magnetic resonance imaging (MRI) improves sensitivity, susceptibility contrast, and spatial or spectral resolution for functional and localized spectroscopic imaging applications. However, along with these benefits come the challenges of increasing static field (B(0)) and rf field (B(1)) inhomogeneities induced by radial field susceptibility differences and poorer dielectric properties of objects in the scanner. Increasing fields also impose the need for rf irradiation at higher frequencies which may lead to elevated patient energy absorption, eventually posing a safety risk. These reasons have motivated the use of multidimensional rf pulses and parallel rf transmission, and their combination with tailoring of rf pulses for fast and low-power rf performance. For the latter application, analytical and approximate solutions are well-established in linear regimes, however, with increasing nonlinearities and constraints on the rf pulses, numerical iterative methods become attractive. Among such procedures, optimal control methods have recently demonstrated great potential. Here, we present a Krotov-based optimal control approach which as compared to earlier approaches provides very fast, monotonic convergence even without educated initial guesses. This is essential for in vivo MRI applications. The method is compared to a second-order gradient ascent method relying on the Broyden-Fletcher-Goldfarb-Shanno (BFGS) quasi-Newton method, and a hybrid scheme Krotov-BFGS is also introduced in this study. These optimal control approaches are demonstrated by the design of a 2D spatial selective rf pulse exciting the letters "JCP" in a water phantom.
Assuntos
Algoritmos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Simulação por Computador , Campos Magnéticos , Processamento de Sinais Assistido por ComputadorRESUMO
A low-cost single-crystal NMR kit is presented along with a web-based post-processing software. The kit consists of a piezo-crystal motor and a goniometer for the crystal, both embedded in a standard wide-bore NMR probe with a 3D printed scaffold. The NMR pulse program controls the angle setting automatically, and the post-processing software incorporates a range of orientation-angle discrepancies present in the kit and other single-crystal setups. Results with a NaNO3 single-crystal show a high degree of reproducibility and excellent agreement with previous findings for the anisotropic quadrupolar interaction.
RESUMO
There is an increasing need for development of advanced radio-frequency (RF) pulse techniques in modern magnetic resonance imaging (MRI) systems driven by recent advancements in ultra-high magnetic field systems, new parallel transmit/receive coil designs, and accessible powerful computational facilities. 2D spatially selective RF pulses are an example of advanced pulses that have many applications of clinical relevance, e.g., reduced field of view imaging, and MR spectroscopy. The 2D spatially selective RF pulses are mostly generated and optimised with numerical methods that can handle vast controls and multiple constraints. With this study we aim at demonstrating that numerical, optimal control (OC) algorithms are efficient for the design of 2D spatially selective MRI experiments, when robustness towards e.g. field inhomogeneity is in focus. We have chosen three popular OC algorithms; two which are gradient-based, concurrent methods using first- and second-order derivatives, respectively; and a third that belongs to the sequential, monotonically convergent family. We used two experimental models: a water phantom, and an in vivo human head. Taking into consideration the challenging experimental setup, our analysis suggests the use of the sequential, monotonic approach and the second-order gradient-based approach as computational speed, experimental robustness, and image quality is key. All algorithms used in this work were implemented in the MATLAB environment and are freely available to the MRI community.
Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Campos Eletromagnéticos , Desenho de Equipamento , Cabeça/anatomia & histologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Imagens de Fantasmas , Controle de Qualidade , Ondas de Rádio , Água , Fluxo de TrabalhoRESUMO
Aimed at (13)C metabolic magnetic resonance imaging (MRI) and spectroscopy (MRS) applications, we demonstrate that dynamic nuclear polarization (DNP) may be combined with optimal control 2D spatial selection to simultaneously obtain high sensitivity and well-defined spatial restriction. This is achieved through the development of spatial-selective single-shot spiral-readout MRI and MRS experiments combined with dynamic nuclear polarization hyperpolarized [1-(13)C]pyruvate on a 4.7 T pre-clinical MR scanner. The method stands out from related techniques by facilitating anatomic shaped region-of-interest (ROI) single metabolite signals available for higher image resolution or single-peak spectra. The 2D spatial-selective rf pulses were designed using a novel Krotov-based optimal control approach capable of iteratively fast providing successful pulse sequences in the absence of qualified initial guesses. The technique may be important for early detection of abnormal metabolism, monitoring disease progression, and drug research.
Assuntos
Isótopos de Carbono/análise , Isótopos de Carbono/química , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Ácido Pirúvico/química , Ácido Pirúvico/análiseRESUMO
Autotomy refers to the voluntary shedding of a body part; a renowned example is tail loss among lizards as a response to attempted predation. Although many aspects of lizard tail autotomy have been studied, the detailed morphology and mechanism remains unclear. In the present study, we showed that tail shedding by the Tokay gecko (Gekko gecko) and the associated extracellular matrix (ECM) rupture were independent of proteolysis. Instead, lizard caudal autotomy relied on biological adhesion facilitated by surface microstructures. Results based on bio-imaging techniques demonstrated that the tail of Gekko gecko was pre-severed at distinct sites and that its structural integrity depended on the adhesion between these segments.