Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
Transl Lung Cancer Res ; 11(4): 560-571, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35529792

RESUMO

Background: Spread through air spaces (STAS) has been reported as a negative prognostic factor in patients with lung cancer undergoing sublobar resection. Radiomics has been recently proposed to predict STAS using preoperative computed tomography (CT). However, limitations of previous studies included the strict selection of imaging acquisition protocols, leading to results hardly applicable to daily clinical practice. The aim of this study is to test a radiomics-based prediction model of STAS in a practice-based dataset. Methods: A training cohort of 99 consecutive patients (65 STAS+ and 34 STAS-) with resected lung adenocarcinoma (ADC) was retrospectively collected. Preoperative CT images were collected from different centers regardless model and scanner manufacture, acquisition and reconstruction protocol, contrast phase and pixel size. Radiomics features were selected according to separation power and P value stability within different preprocessing setups and bootstrapping resampling. A prospective cohort of 50 patients (33 STAS+ and 17 STAS-) was enrolled for the external validation. Results: Only the five features with the highest stability were considered for the prediction model building. Radiomics, radiological and mixed radiomics-radiological prediction models were created, showing an accuracy of 0.66±0.02 after internal validation and reaching an accuracy of 0.78 in the external validation. Conclusions: Radiomics-based prediction models of STAS may be useful to properly plan surgical treatment and avoid oncological ineffective sublobar resections. This study supports a possible application of radiomics-based models on data with high variance in acquisition, reconstruction and preprocessing, opening a new chance for the use of radiomics in the prediction of STAS. Trial Registration: ClinicalTrials.gov identifier: NCT04893200.

3.
Phys Med ; 94: 75-84, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34999515

RESUMO

PURPOSE: One of the obstacles to the application of Boron Neutron Capture Therapy (BNCT) and Proton Boron Fusion Therapy (PBFT) concerns the measurement of borated carriers' biodistribution. The objective of the present study was to evaluate the in vitro internalization of the 19F-labelled p-boronophenylalanine (19F-BPA) in the human cancer pancreatic cell line (PANC-1) for the potential application of BNCT and PBFT in pancreatic cancer. The 19F-BPA carrier has the advantage that its bio-distribution may be monitored in vivo using 19F-Nuclear Magnetic Resonance (19F NMR). MATERIALS AND METHODS: The 19F-BPA internalization in PANC-1 cells was evaluated using three independent techniques on cellular samples left in contact with growing medium enriched with 13.6 mM 19F-BPA corresponding to a 11B concentration of 120 ppm: neutron autoradiography, which quantifies boron; liquid chromatography hyphenated to tandem mass spectrometry and UV-Diode Array Detection (UV-DAD), which quantifies 19F-BPA molecule; and 19F NMR spectroscopy, which detects fluorine nuclei. RESULTS: Our studies suggested that 19F-BPA is internalized by PANC-1 cells. The three methods provided consistent results of about 50% internalization fraction at 120 ppm of 11B. Small variations (less than 15%) in internalization fraction are mainly dependent on the proliferation state of the cells. CONCLUSIONS: The ability of 19F NMR spectroscopy to study 19F-BPA internalization was validated by well-established independent techniques. The multimodal approach we used suggests 19F-BPA as a promising BNCT/PBFT carrier for the treatment of pancreatic cancer. Since the quantification is performed at doses useful for BNCT/PBFT, 19F NMR can be envisaged to monitor 19F-BPA bio-distribution during the therapy.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias Pancreáticas , Terapia com Prótons , Boro , Compostos de Boro , Humanos , Neoplasias Pancreáticas/radioterapia , Distribuição Tecidual
4.
Med Phys ; 44(8): 4276-4286, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28586136

RESUMO

PURPOSE: The real-time monitoring of the spread-out Bragg peak would allow the planned dose delivered during treatment to be directly verified, but this poses a major challenge in modern ion beam therapy. A possible method to achieve this goal is to exploit the production of secondary particles by the nuclear reactions of the beam with the patient and correlate their emission profile to the planned target volume position. In this study, we present both the production rate and energy spectra of the prompt-γ produced by the interactions of the 12 C ion beam with a polymethyl methacrylate (PMMA) target. We also assess three different Monte Carlo models for prompt-γ simulation based on our experimental data. METHODS: The experiment was carried out at the GSI Helmholtz Centre for Heavy Ion Research, Darmstadt, Germany with a 220 MeV/u 12 C ions beam impinging on a 5× 5× 20 cm3 polymethyl methacrylate beam stopping target, with the prompt-γ being detected by a hexagonally-shaped barium fluoride scintillator with a circumscribed radius of 5.4 cm and a length of 14 cm, placed at 60° and 90° with respect to the beam direction. Monte Carlo simulations were carried out with three different hadronic models from the Geant4 code: binary ion cascade (BIC), quantum molecular dynamics (QMD), and Liege intranuclear cascade (INCL++ ). RESULTS: An experimental prompt-γ yield of 1.06 × 10-2  sr-1 was measured at 90°. A good agreement was observed between the shapes of the experimental and simulated energy spectra, especially with the INCL++ physics list. The prompt-γ yield obtained with this physics list was compatible with the measurement within 2σ, with a relative difference of 26% on average. BIC and QMD physics lists proved to be less accurate than INCL++ , with the difference between the measured and simulated yields exceeding 100%. The differences between the three physics lists were ascribed to important discrepancies between the models of the physical processes producing prompt-γ emissions. CONCLUSION: In conclusion, this study provides prompt-γ yield values in agreement with previously published results for different carbon ions energies. This work demonstrates that the INCL++ physics list from Geant4 is more accurate than BIC and QMD to reproduce prompt-γ emission properties.


Assuntos
Benchmarking , Radioterapia com Íons Pesados , Carbono , Humanos , Método de Monte Carlo , Fenômenos Físicos , Radiometria
5.
Phys Med ; 34: 18-27, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28111101

RESUMO

Charged particle therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbon ions. A critical issue is the monitoring of the beam range so to check the correct dose deposition to the tumor and surrounding tissues. The design of a new tracking device for beam range real-time monitoring in pencil beam carbon ion therapy is presented. The proposed device tracks secondary charged particles produced by beam interactions in the patient tissue and exploits the correlation of the charged particle emission profile with the spatial dose deposition and the Bragg peak position. The detector, currently under construction, uses the information provided by 12 layers of scintillating fibers followed by a plastic scintillator and a pixelated Lutetium Fine Silicate (LFS) crystal calorimeter. An algorithm to account and correct for emission profile distortion due to charged secondaries absorption inside the patient tissue is also proposed. Finally detector reconstruction efficiency for charged particle emission profile is evaluated using a Monte Carlo simulation considering a quasi-realistic case of a non-homogenous phantom.


Assuntos
Radioterapia com Íons Pesados/instrumentação , Desenho de Equipamento , Imagens de Fantasmas , Prótons , Dosagem Radioterapêutica , Contagem de Cintilação
6.
Front Oncol ; 6: 177, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27536555

RESUMO

The interaction of the incoming beam radiation with the patient body in hadrontherapy treatments produces secondary charged and neutral particles, whose detection can be used for monitoring purposes and to perform an on-line check of beam particle range. In the context of ion-therapy with active scanning, charged particles are potentially attractive since they can be easily tracked with a high efficiency, in presence of a relatively low background contamination. In order to verify the possibility of exploiting this approach for in-beam monitoring in ion-therapy, and to guide the design of specific detectors, both simulations and experimental tests are being performed with ion beams impinging on simple homogeneous tissue-like targets (PMMA). From these studies, a resolution of the order of few millimeters on the single track has been proven to be sufficient to exploit charged particle tracking for monitoring purposes, preserving the precision achievable on longitudinal shape. The results obtained so far show that the measurement of charged particles can be successfully implemented in a technology capable of monitoring both the dose profile and the position of the Bragg peak inside the target and finally lead to the design of a novel profile detector. Crucial aspects to be considered are the detector positioning, to be optimized in order to maximize the available statistics, and the capability of accounting for the multiple scattering interactions undergone by the charged fragments along their exit path from the patient body. The experimental results collected up to now are also valuable for the validation of Monte Carlo simulation software tools and their implementation in Treatment Planning Software packages.

7.
J Nucl Med ; 56(10): 1501-6, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26338895

RESUMO

UNLABELLED: A novel radioguided surgery (RGS) technique exploiting ß- radiation has been proposed. To develop such a technique, a suitable radiotracer able to deliver a ß- emitter to the tumor has to be identified. A first candidate is represented by 90Y-labeled DOTATOC, a compound commonly used today for peptide radioreceptor therapy. The application of this ß- RGS to neuroendocrine tumors (NET) requires study of the uptake of DOTATOC and its time evolution both in tumors and in healthy organs and evaluation of the corresponding performance of the technique. METHODS: Uptake by lesions and healthy organs (kidneys, spleen, liver and healthy muscle) was estimated on 177Lu-DOTATOC SPECT/CT scans of 15 patients affected by NET with different localizations, treated at IRCCS-Arcispedale Santa Maria Nuova, Reggio Emilia, Italy. For each patient, SPECT/CT images, acquired at 0.5, 4, 20, 40, and 70 h after injection, were studied. For each lesion, the tumor-to-nontumor ratio (TNR) with respect to all healthy organs and its time evolution were studied. A subset of patients showing hepatic lesions was selected, and the TNR with respect to the nearby healthy tissue was calculated. By means of a Monte Carlo simulation of the probe for ß- RGS, the activity that is to be administered for a successful detection was estimated lesion-by-lesion. RESULTS: Uptake of DOTATOC on NETs maximized at about 24 h after injection. The cases of hepatic lesions showed a TNR with respect to the tumor margins compatible with the application of ß- RGS. In particular, 0.1-mL residuals are expected to be detectable within 1 s with 5% false-negative and 1% false-positive by administering the patient as little as 1 MBq/kg. CONCLUSION: The balance between tumor uptake and metabolic washout in healthy tissue causes the TNR to increase with time, reaching its maximum after 24 h, and this characteristic can be exploited when a radiotracer with a long half-life, such as 90Y, is used. In particular, if 90Y-DOTATOC is used with liver NET metastases, the proposed RGS technique is believed to be feasible by injecting an activity that is one third of that commonly used for PET imaging.


Assuntos
Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/cirurgia , Octreotida/análogos & derivados , Compostos Radiofarmacêuticos/farmacocinética , Cirurgia Assistida por Computador/métodos , Partículas beta , Meia-Vida , Humanos , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagem , Octreotida/farmacocinética , Baço/diagnóstico por imagem , Distribuição Tecidual , Tomografia Computadorizada de Emissão de Fóton Único
8.
J Nucl Med ; 56(1): 3-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25500828

RESUMO

UNLABELLED: A novel radioguided surgery (RGS) technique for cerebral tumors using ß(-) radiation is being developed. Checking for a radiotracer that can deliver a ß(-) emitter to the tumor is a fundamental step in the deployment of such a technique. This paper reports a study of the uptake of (90)Y-DOTATOC in meningiomas and high-grade gliomas (HGGs) and a feasibility study of the RGS technique in these types of tumor. Estimates were performed assuming the use of a ß(-) probe under development with a sensitive area 2.55 mm in radius to detect 0.1-mL residuals. METHODS: Uptake and background from healthy tissues were estimated on (68)Ga-DOTATOC PET scans of 11 meningioma patients and 12 HGG patients. A dedicated statistical analysis of the DICOM images was developed and validated. The feasibility study was performed using full simulation of emission and detection of the radiation, accounting for the measured uptake and background rate. RESULTS: All meningioma patients but one with an atypical extracranial tumor showed high uptake of DOTATOC. In terms of feasibility of the RGS technique, we estimated that by administering a 3 MBq/kg activity of radiotracer, the time needed to detect a 0.1-mL remnant with 5% false-negative and 1% false-positive rates is less than 1 s. Actually, to achieve a detection time of 1 s the required activities to administer were as low as 0.2-0.5 MBq/kg in many patients. In HGGs, the uptake was lower than in meningiomas, but the tumor-to-nontumor ratio was higher than 4, which implies that the tracer can still be effective for RGS. It was estimated that by administering 3 mBq/kg of radiotracer, the time needed to detect a 0.1-mL remnant is less than 6 s, with the exception of the only oligodendroma in the sample. CONCLUSION: Uptake of (90)Y-DOTATOC in meningiomas was high in all studied patients. Uptake in HGGs was significantly worse than in meningiomas but was still acceptable for RGS, particularly if further research and development are done to improve the performance of the ß(-) probe.


Assuntos
Partículas beta , Glioma/cirurgia , Neoplasias Meníngeas/cirurgia , Meningioma/cirurgia , Octreotida/análogos & derivados , Somatostatina/análogos & derivados , Cirurgia Assistida por Computador/métodos , Transporte Biológico , Glioma/metabolismo , Glioma/patologia , Humanos , Neoplasias Meníngeas/metabolismo , Meningioma/metabolismo , Gradação de Tumores , Octreotida/química , Octreotida/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA