Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Crit Care ; 20: 3, 2016 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-26743570

RESUMO

BACKGROUND: Electrical impedance tomography (EIT) is a non-invasive bedside tool which allows an individualized ventilator strategy by monitoring tidal ventilation and lung aeration. EIT can be performed at different cranio-caudal thoracic levels, but data are missing about the optimal belt position. The main goal of this prospective observational study was to evaluate the impact of different electrode layers on tidal impedance variation in relation to global volume changes in order to propose a proper belt position for EIT measurements. METHODS: EIT measurements were performed in 15 mechanically ventilated intensive care patients with the electrode belt at different thoracic layers (L1-L7). All respiratory and hemodynamic parameters were recorded. Blood gas analyses were obtained once at the beginning of EIT examination. Off-line tidal impedance variation/tidal volume (TV/VT) ratio was calculated, and specific patterns of impedance distribution due to automatic and user-defined adjustment of the colour scale for EIT images were identified. RESULTS: TV/VT ratio is the highest at L1. It decreases in caudal direction. At L5, the decrease of TV/VT ratio is significant. We could identify patterns of diaphragmatic interference with ventilation-related impedance changes, which owing to the automatically adjusted colour scales are not obvious in the regularly displayed EIT images. CONCLUSIONS: The clinical usability and plausibility of EIT measurements depend on proper belt position, proper impedance visualisation, correct analysis and data interpretation. When EIT is used to estimate global parameters like VT or changes in end-expiratory lung volume, the best electrode plane is between the 4th and 5th intercostal space. The specific colour coding occasionally suppresses user-relevant information, and manual rescaling of images is necessary to visualise this information.


Assuntos
Equipamentos Médicos Duráveis , Impedância Elétrica/uso terapêutico , Respiração com Pressão Positiva/métodos , Tomografia/instrumentação , Tomografia/métodos , Idoso , Eletrodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente/métodos , Posicionamento do Paciente/normas , Estudos Prospectivos , Volume de Ventilação Pulmonar/fisiologia
2.
Biomed Tech (Berl) ; 64(2): 135-145, 2019 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-29874190

RESUMO

There is no agreement on gold standard method for positive end-expiratory pressure (PEEP) titration. Electrical impedance tomography (EIT) may aid in finding the optimal PEEP level. In this pilot trial, we investigated potential differences in the suggested optimal PEEP (BestPEEP) as derived by respiratory compliance and EIT-derived parameters. We examined if compliance-derived PEEP differs with regard to the regional ventilation distribution in relation to atelectasis and hyperinflation. Measurements were performed during an incremental/decremental PEEP trial in 15 ventilated intensive care patients suffering from mild-to-moderate impairment of oxygenation due to sepsis, pneumonia, trauma and metabolic and ischemic disorders. Measurement agreement was analyzed using Bland-Altman plots. We observed a diversity of EIT-derived and compliance-based optimal PEEP in the evaluated patients. BestPEEPCompliance did not necessarily correspond to the BestPEEPODCL with the least regional overdistension and collapse. The collapsed area was significantly smaller when the overdistension/collapse index was used for PEEP definition (p=0.022). Our results showed a clinically relevant difference in the suggested optimal PEEP levels when using different parameters for PEEP titration. The compliance-derived PEEP level revealed a higher proportion of residual regional atelectasis as compared to EIT-based PEEP.


Assuntos
Respiração com Pressão Positiva/métodos , Tomografia/métodos , Impedância Elétrica , Humanos , Respiração , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA