Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Oral Investig ; 24(8): 2853-2866, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31754872

RESUMO

OBJECTIVES: To validate the accuracy and reproducibility of linear measurements of three-dimensional (3D) images and to compare the measurements with the direct anthropometry method on cleft lip and palate (CLP) patients. MATERIALS AND METHODS: Nineteen linear facial measurements were derived from 16 standardized surface landmarks obtained from 37 cleft patients (20 males, 17 females; mean age 23.84 years, standard deviation ± 6.02). They were taken manually with calipers and were compared with the digitally calculated distance on the 3D images captured using the VECTRA-M5 360° Imaging System with pre-marked landmarks. Another pair of 19 linear measurements were computed on the 3D images 2 weeks apart for intra- and inter-observer agreements. Statistical analyses used were paired t test, the Bland-Altman analysis, and the intra-class correlation coefficient (ICC) index. RESULTS: Most of the linear measurements showed no statistically significant differences between the proposed method and direct anthropometry linear measurements. Nevertheless, bias of the 3D imaging system is present in the linear measurements of the nose width and the upper vermillion height. The measurements' mean biases were within 2 mm, but the 95% limit of agreement was more than 2 mm. Intra- and inter-observer measurements generally showed good reproducibility. Four inter-observer measurements, the upper and lower face heights, nose width, and pronasale to left alar base were clinically significant. CONCLUSIONS: Measurements obtained from this 3D imaging system are valid and reproducible for evaluating CLP patients. CLINICAL RELEVANCE: The system is suitable to be used in a clinical setting for cleft patients. However, training of the operator is strictly advisable.


Assuntos
Fotogrametria , Antropometria , Fenda Labial , Fissura Palatina , Feminino , Humanos , Imageamento Tridimensional , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
2.
PLoS One ; 16(7): e0254478, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34243187

RESUMO

Flipped classroom may overcome weaknesses of live demonstration in teaching orthodontic wire-bending. This study aims to compare the effectiveness between flipped classroom and live demonstration in transferring skills for fabricating Adams clasp. Forty third-year undergraduate dental students were assigned to two groups. The students in group LD (n = 20) attended a live demonstration while students in group FC (n = 20) attended a flipped classroom. Both groups were taught on skills to fabricate Adams clasp in a standardised way. Each student from both groups were asked to submit an Adams clasp for a blinded quality assessment by two trained and calibrated assessors using a 18-item rubric, followed by validated students' satisfaction questionnaires to evaluate their perceived satisfaction on the teaching method received. A crossover study was then conducted three weeks later where LD attended a flipped classroom while FC attended a live demonstration. Students' satisfaction questionnaires were again collected from each student for blinded analysis. Mean scores for the quality of Adams clasp were 9.775 and 9.125 for LD and FC, respectively. No significant difference was detected between the two groups. Statistically significant association was found for one statement on the questionnaire, "I found the classroom arrangements conducive for the wire-bending activity" (p = 0.010). No significant differences were found between the two groups for other statements (p > 0.05). In conclusion, within the limitations of the study, flipped classroom is equally effective as conventional live demonstration in transferring orthodontic wire-bending skills for fabrication of Adams clasp. However, students perceived the classroom arrangements during the flipped classroom significantly more conducive for teaching orthodontic wire-bending.


Assuntos
Fios Ortodônticos , Estudos Cross-Over , Feminino , Humanos , Masculino , Aprendizagem Baseada em Problemas/métodos , Inquéritos e Questionários
3.
J Clin Neurosci ; 17(10): 1343-4, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20620064

RESUMO

A 24-year-old male patient with refractory Tourette syndrome was treated with deep brain stimulation (DBS) and developed subsequent bilateral subcortical haematomas. Additional blood tests revealed abnormalities of plasma factor XIIIA and tryptophan levels, which may be associated with Tourette syndrome. Neurosurgeons who perform DBS surgery on patients with Tourette syndrome must be aware of possible disastrous complications resulting from factor XIIIA disorders of blood haemostasis. Routine screening for this condition is not typically performed prior to surgery in these patients.


Assuntos
Estimulação Encefálica Profunda/efeitos adversos , Fator XIIIa/metabolismo , Hematoma/etiologia , Hematoma/diagnóstico , Humanos , Masculino , Tomografia Computadorizada por Raios X/métodos , Síndrome de Tourette/cirurgia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA