Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 61(8): 1411-1419, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-36952681

RESUMO

The International Federation of Clinical Chemistry Committee on Clinical Applications of Cardiac Biomarkers (IFCC C-CB) provides educational documents to facilitate the interpretation and use of cardiac biomarkers in clinical laboratories and practice. Our aim is to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay. Measurements of cardiac troponin (cTn) have a prominent place in the clinical work-up of patients with suspected acute coronary syndrome. It is therefore important that clinical laboratories know how to recognize and assess analytical issues. Two emerging analytical issues resulting in falsely high cTn concentrations, often several fold higher than the upper reference limit (URL), are antibody-mediated assay interference due to long-lived cTn-antibody complexes, called macrotroponin, and crosslinking antibodies that are frequently referred to as heterophilic antibodies. We provide an overview of antibody-mediated cTn assay interference and provide recommendations on how to confirm the interference and interpret the results.


Assuntos
Infarto do Miocárdio , Humanos , Biomarcadores , Química Clínica , Anticorpos , Troponina
2.
Clin Chem Lab Med ; 60(11): 1736-1744, 2022 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36036565

RESUMO

OBJECTIVES: To assess interlaboratory variability of total serum bilirubin (TSB) results in newborns. Initiated following a clinical incident in which a neonate was transferred to a tertiary hospital for treatment of severe hyperbilirubinemia but on arrival was reclassified into a lower risk category due to a 20% difference in TSB between laboratories. METHODS: Fresh residual plasma samples from hospital-born infants were pooled to obtain 11 samples across a range of total bilirubin concentrations. Aliquots were light-protected and measured on 7 commercial platforms at 4 accredited medical laboratories. Data from The Royal College of Pathologists of Australasia Quality Assurance Programs' (RCPAQAP) Neonatal Bilirubin program was analysed. RESULTS: Twenty-four to 30% difference in results for individual samples, largely due to calibration differences between assays. When interpreted according to guidelines, results from different platforms would have led to different clinical interventions in some cases. RCPAQAP results showed significant within-method bias but were not shown to be commutable with patient samples. CONCLUSIONS: There are clinically significant method-dependent differences in TSB results from neonatal samples, consistent with our clinical incident. The differences are largely due to lack of standardisation of calibrator values. This has implications for healthcare resource use and possibly for the neurodevelopment of infants. Intervention is needed at a number of levels, including clinical reporting of incidents arising from discordant results, commitment by manufacturers to ensure metrological traceability of methods with sufficiently low uncertainty in the final measurements, and availability of commutable quality assurance material to monitor assay performance, especially at the clinical decision points for neonatal jaundice.


Assuntos
Hiperbilirrubinemia Neonatal , Icterícia Neonatal , Bilirrubina , Calibragem , Humanos , Hiperbilirrubinemia Neonatal/diagnóstico , Hiperbilirrubinemia Neonatal/terapia , Lactente , Recém-Nascido , Icterícia Neonatal/terapia , Padrões de Referência
3.
Clin Chem Lab Med ; 54(11): 1821-1829, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27092651

RESUMO

BACKGROUND: Cardiac troponin is the preferred biomarker of myocardial injury. High-sensitivity troponin assays allow measurement of very low levels of troponin with excellent precision. After the introduction of a high-sensitivity troponin I assay the laboratory began to receive enquiries from clinicians about clinically discordant elevated troponin I results. This led to a systematic investigation and characterisation of the cause. METHODS: Routine clinical samples were measured by the Architect High Sensitive Troponin-I (hsTnI) and the VITROS Troponin I ES assays (VitrosTnI). Results that were elevated according to the Architect but not the VITROS assay (Group 1) or results elevated by both assays but disproportionately higher on the Architect (Group 2) were re-analysed for hsTnI after re-centrifugation, multiple dilutions, incubation with heterophilic blocking reagents, polyethylene glycol (PEG) precipitation, and Protein A/G/L treatment. Sephacryl S-300 HR gel filtration chromatography (GFC) was performed on selected specimens. RESULTS: A high molecular weight complex containing immunoreactive troponin I and immunoglobulin (macrotroponin I) was identified in 5% of patients with elevated hsTnI. Patients with both macrotroponin and myocardial injury had higher and longer elevation of hsTnI compared with VitrosTnI with peaks of both macrotroponin and free troponin I-C complex on GFC. CONCLUSIONS: Circulating macrotroponin I (macroTnI) causes elevated hsTnI results with the Architect High Sensitive Troponin-I assay with the potential to be clinically misleading. The assay involved in this investigation may not be the only assay affected by macrotroponin. It is important for laboratories and clinicians to be aware of and develop processes to identify and manage specimens with elevated results due to macrotroponin.


Assuntos
Imunoensaio , Troponina I/sangue , Cromatografia em Gel , Humanos , Peso Molecular
4.
BMC Med Res Methodol ; 13: 135, 2013 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-24209392

RESUMO

BACKGROUND: Patient registries represent a well-established methodology for prospective data collection with a wide array of applications for clinical research and health care administration. An examination and synthesis of registry stakeholder perspectives has not been previously reported in the literature. METHODS: To inform the development of future neurological registries we examined stakeholder perspectives about such registries through a literature review followed by 3 focus groups comprised of a total of 15 neurological patients and 12 caregivers. RESULTS: (1) LITERATURE REVIEW: We identified 6,435 abstracts after duplicates were removed. Of these, 410 articles underwent full text review with 24 deemed relevant to perspectives about neurological and non-neurological registries and were included in the final synthesis. From a patient perspective the literature supports altruism, responsible use of data and advancement of research, among others, as motivating factors for participating in a patient registry. Barriers to participation included concerns about privacy and participant burden (i.e. extra clinic visits and associated costs). (2) Focus groups: The focus groups identified factors that would encourage participation such as: having a clear purpose; low participant burden; and being well-managed among others. CONCLUSIONS: We report the first examination and synthesis of stakeholder perspectives on registries broadly with a specific focus on neurological patient registries. The findings of the broad literature review were congruent with the neurological patient and caregiver focus groups. We report common themes across the literature and the focus groups performed. Stakeholder perspectives need to be considered when designing and operating patient registries. Emphasizing factors that promote participation and mitigating barriers may enhance patient recruitment.


Assuntos
Doenças do Sistema Nervoso/terapia , Sistema de Registros , Grupos Focais , Necessidades e Demandas de Serviços de Saúde , Humanos , Doenças do Sistema Nervoso/epidemiologia , Participação do Paciente
5.
J Hum Genet ; 56(2): 156-60, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21150920

RESUMO

Premature ovarian failure (POF) is a disorder characterized by amenorrhea and elevated serum gonadotropins before 40 years of age. As X chromosomal abnormalities are often recognized in POF patients, defects of X-linked gene may contribute to POF. Four cases of POF with t(X;autosome) were genetically analyzed. All the translocation breakpoints were determined at the nucleotide level. Interestingly, COL4A6 at Xq22.3 encoding collagen type IV alpha 6 was disrupted by the translocation in one case, but in the remaining three cases, breakpoints did not involve any X-linked genes. According to the breakpoint sequences, two translocations had microhomology of a few nucleotides and the other two showed insertion of 3-8 nucleotides with unknown origin, suggesting that non-homologous end-joining is related to the formation of all the translocations.


Assuntos
Pontos de Quebra do Cromossomo , Cromossomos Humanos X , Insuficiência Ovariana Primária/genética , Translocação Genética , Sequência de Bases , Feminino , Genes Ligados ao Cromossomo X , Humanos , Mutagênese Insercional , Homologia de Sequência do Ácido Nucleico
6.
Clin Endocrinol (Oxf) ; 70(6): 838-46, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18823395

RESUMO

OBJECTIVE: Reduced bone mineral density (BMD) and increased rates of atraumatic fracture are observed in cystic fibrosis (CF) patients, causing increasing morbidity as this population ages. The study aimed to assess the safety, tolerability and effect on BMD of intravenous zoledronate in adults with CF and osteopaenia. DESIGN: Randomized, double-blind, placebo-controlled clinical trial. SETTING: Adult CF outpatient clinics at two hospitals. PATIENTS: Twenty-two non-transplanted CF patients aged > or = 18 years with a bone densitometry T-score of < -1.5 at one of three sites (lumbar spine, femoral neck, distal forearm) were studied. Participants were randomized to receive either 2 mg zoledronate i.v. (n = 10) or normal saline (placebo, n = 12) every 3 months for 2 years (8 infusions). All participants received calcium and vitamin D supplements twice daily. MEASUREMENTS: Percentage change in areal BMD from baseline. RESULTS: Lumbar spine BMD increased from baseline more with zoledronate than placebo at 6 months (5.35 +/- 0.76 vs. 1.19 +/- 1.20%, P = 0.012), 12 months (6.6 +/- 1.5 vs. 0.35 +/- 1.55%, P = 0.011) and 24 months (6.14 +/- 1.86 vs. 0.44 +/- 0.10, P = 0.021). Femoral neck BMD increased more after zoledronate than placebo at 6 months (3.2 +/- 1.6 vs.-1.43 +/- 0.43%, P = 0.019), 12 months (4.12 +/- 1.8 vs.-1.59 +/- 1.4%, P = 0.024) and 24 months (4.23 +/- 1.3 vs.-2.5 +/- 1.41%, P = 0.0028). Forearm BMD did not change. Zoledronate was associated with flu-like and musculoskeletal side effects, particularly after the first infusion. There were no fractures in either group. CONCLUSION: Intravenous zoledronate was significantly more effective than placebo for increasing BMD in adults with CF and osteopaenia, but side effects limited its tolerability.


Assuntos
Conservadores da Densidade Óssea/uso terapêutico , Densidade Óssea/efeitos dos fármacos , Fibrose Cística/complicações , Difosfonatos/uso terapêutico , Imidazóis/uso terapêutico , Osteoporose/tratamento farmacológico , Adulto , Fibrose Cística/tratamento farmacológico , Método Duplo-Cego , Feminino , Humanos , Masculino , Osteoporose/etiologia , Placebos , Ácido Zoledrônico
14.
Comb Chem High Throughput Screen ; 8(4): 327-39, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16101009

RESUMO

We report a systematic analysis of the P1' and P2' substrate specificity of TNF-alpha converting enzyme (TACE) using a peptide library and a novel analytical method, and we use the substrate specificity information to design novel reverse hydroxamate inhibitors. Initial truncation studies, using the amino acid sequence around the cleavage site in precursor-TNF-alpha, showed that good turnover was obtained with the peptide DNP-LAQAVRSS-NH2. Based on this result, 1000 different peptide substrates of the form Biotin-LAQA-P1'-P2'-SSK(DNP)-NH2 were prepared, with 50 different natural and unnatural amino acids at P1' in combination with 20 different amino acids at P2'. The peptides were pooled, treated with purified microsomal TACE, and the reaction mixtures were passed over a streptavidin affinity column to remove unreacted substrate and the N-terminal biotinylated product. C-terminal cleavage products not binding to streptavidin were subjected to liquid chromatography/mass spectrometry analysis where individual products were identified and semiquantitated. 25 of the substrates were resynthesized as discrete peptides and assayed with recombinant TACE. The experiments show that recombinant TACE prefers lipophilic amino acids at the P1' position, such as phenylglycine, homophenylalanine, leucine and valine. At the P2' position, TACE can accommodate basic amino acids, such as arginine and lysine, as well as certain non-basic amino acids such as citrulline, methionine sulfoxide and threonine. These substrate preferences were used in the design of novel reverse hydroxamate TACE inhibitors with phenethyl and 5-methyl-thiophene-methyl side-chains at P1', and threonine and nitro-arginine at P2'.


Assuntos
Avaliação Pré-Clínica de Medicamentos/métodos , Metaloendopeptidases/antagonistas & inibidores , Metaloendopeptidases/metabolismo , Inibidores de Proteases/química , Inibidores de Proteases/farmacologia , Mapeamento de Interação de Proteínas/métodos , Proteínas ADAM , Proteína ADAM17 , Sítios de Ligação , Biotina/química , Cromatografia Líquida/métodos , Desenho de Fármacos , Processamento de Imagem Assistida por Computador , Espectrometria de Massas/métodos , Metaloendopeptidases/genética , Modelos Moleculares , Biblioteca de Peptídeos , Peptídeos/química , Peptídeos/farmacologia , Conformação Proteica , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Relação Estrutura-Atividade , Especificidade por Substrato , Fator de Necrose Tumoral alfa/metabolismo
15.
J Anal Toxicol ; 39(2): 140-3, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25342718

RESUMO

In Australia, it is a requirement of workplace oral fluid (OF) drugs of abuse testing that drug recovery from collection devices be verified by an accredited laboratory. Recovery data are used in conjunction with collection volume imprecision data and uncertainty of measurement to provide an estimation of drug concentration in neat OF. The manufacturer's product information for the DCD5000 collection device indicates that the collection volume of the swab is 380 µL. Recovery data for the swab when used with the isopropanol provided by the manufacturer are not available. A series of experiments using fortified drug-free OF were performed to assess the collection volume imprecision of the Dräger DCD5000 swab and the recovery of drugs from the swab using isopropanol. The fortified OF was collected with the swabs (n = 16), and swabs were discharged into vials of isopropanol as per the manufacturer's instructions. The mean collection volume of the DCD5000 swab was 487 µL with an imprecision of 1.3%. Recovery of drug from the device ranged from 86 to 98% for drugs listed in the Australian OF workplace testing standard. Recovery of methadone, buprenorphine and norbuprenorphine ranged from 93 to 102%. Recovery of 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidene was 45%, suggesting that urine is more suitable sample if methadone therapy is being monitored. Overall, drug recovery from the device using isopropanol was acceptable when the increased collection volume of the swab was taken into account.


Assuntos
Detecção do Abuso de Substâncias/instrumentação , 2-Propanol/análise , Austrália , Humanos
16.
Artigo em Inglês | MEDLINE | ID: mdl-22521213

RESUMO

An LC-MS/MS method for the quantitation of urinary metabolites of eight JWH-type synthetic cannabinoids (SCs) has been developed and validated. Urine samples are subjected to deconjugation using ß-glucuronidase, followed by a solvent extraction procedure. Compounds are separated on a reverse-phase HPLC column within a 14 min cycle. Low assay limits are required in order to demonstrate prior exposure to SCs. Matrix effects were studied and proved to be significant for selected analytes, and were challenging to circumvent as isotope-labeled internal standards are not available. An elimination profile from a naïve user following a single smoke of "Kronic" was constructed, showing urinary excretion over 2-3 days with peak concentrations of different metabolites 3-16.5 h after smoking. This method has been developed to process several hundred samples within a high-throughput drugs of abuse laboratory, with growing evidence that the use of synthetic cannabinoid blends is common within the Australian workforce.


Assuntos
Canabinoides/urina , Cromatografia de Fase Reversa/métodos , Indóis/urina , Naftalenos/urina , Espectrometria de Massas em Tandem/métodos , Acetatos , Acetonitrilas , Austrália , Cromatografia Líquida de Alta Pressão/métodos , Drogas Desenhadas , Humanos , Drogas Ilícitas , Indóis/metabolismo , Modelos Lineares , Metanol , Naftalenos/metabolismo , Reprodutibilidade dos Testes
18.
Diabetes Technol Ther ; 13(1): 55-62, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21175272

RESUMO

BACKGROUND: within hospitals, bedside blood glucose measurements are widely used for investigating suspected hyper- or hypoglycemia, monitoring diabetes, and adjusting glucose-lowering medication. Numerous point-of-care glucose meters are available, but for large hospitals using the same meter in all settings has practical and economic advantages. This investigation sought to identify a meter that was accurate, precise, and free from interferences, making it suitable for use across all ages and diseases. METHODS: lithium-heparinized whole blood was analyzed, under various conditions, on the HemoCue Glucose 201 (Hemocue AB, Ängelhom, Sweden), Accu-Chek Performa (Roche Diagnostics, Basel Switzerland) (using the newly reformulated maltose-insensitive strips), and Optium (Abbott Diabetes, Alameda, CA, USA) glucose meters and compared with plasma glucose measurements on the Vitros 5,1 FS analyzer (Ortho Clinical Diagnostics, Neckargemund, Germany). RESULTS: biases of 3.2%, -5.8%, and -8% were found with Accu-Chek, Optium, and HemoCue, respectively. Within-run imprecision was 2.5-5.8%. Between-run imprecision was 3.1-6.8%, with the Accu-Chek performing best. All meters measured to 1.3 mmol/L with acceptable precision (coefficient of variation, <14%). Varying hematocrits between 0.2 and 0.7 L/L affected results of all meters. Interference at clinically relevant concentrations of galactose and possibly maltose was demonstrated with the Accu-Chek. CONCLUSIONS: all three meters are sufficiently accurate and precise for in-hospital use. Because of possible interference by galactosemia or high hematocrit, the Accu-Chek is not the safest option for neonatal use. Patients receiving high doses of maltose in therapeutic infusions may still be at risk of being falsely classified as euglycemic or hyperglycemic with the reformulated Accu-Chek strips, and clinical evaluation of these strips in patients receiving maltose-containing infusions is urgently needed.


Assuntos
Glicemia/análise , Equipamentos para Diagnóstico/normas , Sistemas Automatizados de Assistência Junto ao Leito/normas , Adulto , Galactose/análise , Hematócrito , Humanos , Recém-Nascido , Maltose/análise , Análise de Regressão , Reprodutibilidade dos Testes
19.
Am J Obstet Gynecol ; 187(2): 349-52, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12193923

RESUMO

OBJECTIVE: The purpose of this study was to quantify the baseline inaccuracies in histopathologic diagnosis between colposcopically directed cervical biopsies and loop electrosurgical excision procedure specimens. STUDY DESIGN: A retrospective review was made of cervical biopsies and loop electrosurgical excision procedure pairs (n = 448) that were performed at the University of Arizona between 1992 and 2000. Agreement was assessed by kappa statistics and Spearman rho coefficients. Subgroup analysis was performed (n = 139) to assess pairs with significant inaccuracy between biopsy and loop electrosurgical excision procedure, when these were performed within 28 days of each other. RESULTS: Eighty-one percent agreement was found between cervical biopsy and loop electrosurgical excision procedure histopathologic diagnoses, when compared to within 1 degree (kappa, 0.73; P <.0001). A discrepancy that would be attributed to regression or progression was found: mild biopsy (regression, none by definition; progression, 4%), moderate biopsy (regression, 9%; progression, 0%), and severe biopsy (regression, 26%; progression, 0%). CONCLUSION: Even when colposcopically directed cervical biopsy correlates strongly with loop electrosurgical excision procedure histopathologic diagnosis, there is a definable percentage of patients for whom there is a discrepancy between these 2 diagnoses. This discrepancy represents an inherent inaccuracy of the diagnostic testing modality and should not be interpreted as progression or regression of disease.


Assuntos
Biópsia/normas , Eletrocirurgia/normas , Displasia do Colo do Útero/patologia , Progressão da Doença , Feminino , Humanos , Estudos Retrospectivos , Estatísticas não Paramétricas , Displasia do Colo do Útero/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA