Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Neuroimage ; 189: 329-340, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30639839

RESUMO

The sensation of touch in the glabrous skin of the human hand is conveyed by thousands of fast-conducting mechanoreceptive afferents, which can be categorised into four distinct types. The spiking properties of these afferents in the periphery in response to varied tactile stimuli are well-characterised, but relatively little is known about the spatiotemporal properties of the neural representations of these different receptor types in the human cortex. Here, we use the novel methodological combination of single-unit intraneural microstimulation (INMS) with magnetoencephalography (MEG) to localise cortical representations of individual touch afferents in humans, by measuring the extracranial magnetic fields from neural currents. We found that by assessing the modulation of the beta (13-30 Hz) rhythm during single-unit INMS, significant changes in oscillatory amplitude occur in the contralateral primary somatosensory cortex within and across a group of fast adapting type I mechanoreceptive afferents, which corresponded well to the induced response from matched vibrotactile stimulation. Combining the spatiotemporal specificity of MEG with the selective single-unit stimulation of INMS enables the interrogation of the central representations of different aspects of tactile afferent signalling within the human cortices. The fundamental finding that single-unit INMS ERD responses are robust and consistent with natural somatosensory stimuli will permit us to more dynamically probe the central nervous system responses in humans, to address questions about the processing of touch from the different classes of mechanoreceptive afferents and the effects of varying the stimulus frequency and patterning.


Assuntos
Vias Aferentes/fisiologia , Ritmo beta/fisiologia , Magnetoencefalografia/métodos , Mecanorreceptores/fisiologia , Córtex Somatossensorial/fisiologia , Percepção do Tato/fisiologia , Adulto , Idoso , Estimulação Elétrica , Feminino , Mãos/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Vibração , Adulto Jovem
2.
J Neurophysiol ; 120(4): 1885-1892, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30044679

RESUMO

C-tactile (CT) afferents respond to gentle tactile stimulation, but only a handful of studies in humans and animals have investigated whether their firing is modified by temperature. We describe the effects of radiant thermal stimuli, and of stationary and very slowly moving mechanothermal stimuli, on CT afferent responses. We find that CT afferents are primarily mechanoreceptors, as they fired little during radiant thermal stimuli, but they exhibited different patterns of firing during combined mechano-cool stimulation compared with warming. CTs fired optimally to gentle, very slowly moving, or stationary mechanothermal stimuli delivered at neutral temperature (~32°C, normal skin temperature), but they responded with fewer spikes (median 67% decrease) and at significantly lower rates (47% decrease) during warm (~42°C) tactile stimuli. During cool tactile stimuli (~18°C), their mean instantaneous firing frequency significantly decreased by 35%, but they often fired a barrage of afterdischarge spikes at a low frequency (~5 Hz) that outlasted the mechanical stimulus. These effects were observed under a variety of stimulus conditions, including during stationary and slowly moving touch (0.1 cm/s), and we complemented these tactile approaches using a combined electrical-thermal stimulation experiment where we found a suppression of spiking during warming. Overall, CT afferents are exquisitely sensitive to tactile events, and we show that their firing is modulated with touch temperatures above and below neutral skin temperature. Warm touch consistently decreased their propensity to fire, whereas cool touch produced lower firing rates but afterdischarge spiking. NEW & NOTEWORTHY C-tactile (CT) afferents are thought to underpin pleasant touch, and previous work has shown that they respond optimally to a slow caress delivered at typical (neutral) skin temperature. Here, we show that, although CTs are primarily mechanoreceptive afferents, they are modified by temperature: warm touch decreases their firing, whereas cool touch produces lower firing rates but long-lasting spiking, frequently seen as afterdischarges. This has implications for the encoding of affective sensory events in human skin.


Assuntos
Potenciais Evocados , Temperatura Alta , Percepção do Tato , Tato , Adulto , Vias Aferentes/fisiologia , Estimulação Elétrica , Feminino , Humanos , Masculino , Mecanorreceptores/fisiologia
3.
J Neurophysiol ; 117(4): 1608-1614, 2017 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28123010

RESUMO

C-mechanoreceptors in humans comprise a population of unmyelinated afferents exhibiting a wide range of mechanical sensitivities. C-mechanoreceptors are putatively divided into those signaling gentle touch (C-tactile afferents, CTs) and nociception (C-mechanosensitive nociceptors, CMs), giving rise to positive and negative affect, respectively. We sought to distinguish, compare, and contrast the properties of a population of human C-mechanoreceptors to see how fundamental the divisions between these putative subpopulations are. We used microneurography to record from individual afferents in humans and applied electrical and mechanical stimulation to their receptive fields. We show that C-mechanoreceptors can be distinguished unequivocally into two putative populations, comprising CTs and CMs, by electrically evoked spike latency changes (slowing). After both natural mechanical stimulation and repetitive electrical stimulation there was markedly less latency slowing in CTs compared with CMs. Electrical receptive field stimulation, which bypasses the receptor end organ, was most effective in classifying C-mechanoreceptors, as responses to mechanical receptive field stimulation overlapped somewhat, which may lead to misclassification. Furthermore, we report a subclass of low-threshold CM responding to gentle mechanical stimulation and a potential subclass of CT afferent displaying burst firing. We show that substantial differences exist in the mechanisms governing axonal conduction between CTs and CMs. We provide clear electrophysiological "signatures" (extent of latency slowing) that can be used in unequivocally identifying populations of C-mechanoreceptors in single-unit and multiunit microneurography studies and in translational animal research into affective touch. Additionally, these differential mechanisms may be pharmacologically targetable for separate modulation of positive and negative affective touch information.NEW & NOTEWORTHY Human skin encodes a plethora of touch interactions, and affective tactile information is primarily signaled by slowly conducting C-mechanoreceptive afferents. We show that electrical stimulation of low-threshold C-tactile afferents produces markedly different patterns of activity compared with high-threshold C-mechanoreceptive nociceptors, although the populations overlap in their responses to mechanical stimulation. This fundamental distinction demonstrates a divergence in affective touch signaling from the first stage of sensory processing, having implications for the processing of interpersonal touch.


Assuntos
Mecanorreceptores/fisiologia , Fibras Nervosas Amielínicas/fisiologia , Nociceptores/fisiologia , Tempo de Reação/fisiologia , Pele/inervação , Tato/fisiologia , Potenciais de Ação/fisiologia , Adulto , Análise de Variância , Estimulação Elétrica , Feminino , Voluntários Saudáveis , Humanos , Masculino , Estimulação Física , Psicofísica , Adulto Jovem
4.
J Neurosci Methods ; 290: 69-78, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28743633

RESUMO

BACKGROUND: Intra-neural microstimulation (INMS) is a technique that allows the precise delivery of low-current electrical pulses into human peripheral nerves. Single unit INMS can be used to stimulate individual afferent nerve fibres during microneurography. Combining this with neuroimaging allows the unique monitoring of central nervous system activation in response to unitary, controlled tactile input, with functional magnetic resonance imaging (fMRI) providing exquisite spatial localisation of brain activity and magnetoencephalography (MEG) high temporal resolution. NEW METHOD: INMS systems suitable for use within electrophysiology laboratories have been available for many years. We describe an INMS system specifically designed to provide compatibility with both ultra-high field (7T) fMRI and MEG. Numerous technical and safety issues are addressed. The system is fully analogue, allowing for arbitrary frequency and amplitude INMS stimulation. RESULTS: Unitary recordings obtained within both the MRI and MEG screened-room environments are comparable with those obtained in 'clean' electrophysiology recording environments. Single unit INMS (current <7µA, 200µs pulses) of individual mechanoreceptive afferents produces appropriate and robust responses during fMRI and MEG. COMPARISON WITH EXISTING METHOD(S): This custom-built MRI- and MEG-compatible stimulator overcomes issues with existing INMS approaches; it allows well-controlled switching between recording and stimulus mode, prevents electrical shocks because of long cable lengths, permits unlimited patterns of stimulation, and provides a system with improved work-flow and participant comfort. CONCLUSIONS: We demonstrate that the requirements for an INMS-integrated system, which can be used with both fMRI and MEG imaging systems, have been fully met.


Assuntos
Encéfalo/citologia , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Magnetoencefalografia , Neurônios/fisiologia , Vias Aferentes/diagnóstico por imagem , Biofísica , Mapeamento Encefálico/métodos , Estimulação Elétrica , Eletroencefalografia , Feminino , Mãos/inervação , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Oxigênio/sangue , Tato
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA