Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 213
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 59(1): 179-189, 2024 01.
Artigo | MEDLINE | ID: mdl-37052580

RESUMO

BACKGROUND: In cardiac T1 mapping, a series of T1 -weighted (T1 w) images are collected and numerically fitted to a two or three-parameter model of the signal recovery to estimate voxel-wise T1 values. To reduce the scan time, one can collect fewer T1 w images, albeit at the cost of precision or/and accuracy. Recently, the feasibility of using a neural network instead of conventional two- or three-parameter fit modeling has been demonstrated. However, prior studies used data from a single vendor and field strength; therefore, the generalizability of the models has not been established. PURPOSE: To develop and evaluate an accelerated cardiac T1 mapping approach based on MyoMapNet, a convolution neural network T1 estimator that can be used across different vendors and field strengths by incorporating the relevant scanner information as additional inputs to the model. STUDY TYPE: Retrospective, multicenter. POPULATION: A total of 1423 patients with known or suspected cardiac disease (808 male, 57 ± 16 years), from three centers, two vendors (Siemens, Philips), and two field strengths (1.5 T, 3 T). The data were randomly split into 60% training, 20% validation, and 20% testing. FIELD STRENGTH/SEQUENCE: A 1.5 T and 3 T, Modified Look-Locker inversion recovery (MOLLI) for native and postcontrast T1 . ASSESSMENT: Scanner-independent MyoMapNet (SI-MyoMapNet) was developed by altering the deep learning (DL) architecture of MyoMapNet to incorporate scanner vendor and field strength as inputs. Epicardial and endocardial contours and blood pool (by manually drawing a large region of interest in the blood pool) of the left ventricle were manually delineated by three readers, with 2, 8, and 9 years of experience, and SI-MyoMapNet myocardial and blood pool T1 values (calculated from four T1 w images) were compared with conventional MOLLI T1 values (calculated from 8 to 11 T1 w images). STATISTICAL TESTS: Equivalency test with 95% confidence interval (CI), linear regression slope, Pearson correlation coefficient (r), Bland-Altman analysis. RESULTS: The proposed SI-MyoMapNet successfully created T1 maps. Native and postcontrast T1 values measured from SI-MyoMapNet were strongly correlated with MOLLI, despite using only four T1 w images, at both field-strengths and vendors (all r > 0.86). For native T1 , SI-MyoMapNet and MOLLI were in good agreement for myocardial and blood T1 values in institution 1 (myocardium: 5 msec, 95% CI [3, 8]; blood: -10 msec, 95%CI [-16, -4]), in institution 2 (myocardium: 6 msec, 95% CI [0, 11]; blood: 0 msec, [-18, 17]), and in institution 3 (myocardium: 7 msec, 95% CI [-8, 22]; blood: 8 msec, [-14, 30]). Similar results were observed for postcontrast T1 . DATA CONCLUSION: Inclusion of field strength and vendor as additional inputs to the DL architecture allows generalizability of MyoMapNet across different vendors or field strength. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 2.


Assuntos
Coração , Miocárdio , Humanos , Masculino , Estudos Retrospectivos , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ventrículos do Coração , Reprodutibilidade dos Testes
2.
J Cardiovasc Magn Reson ; 26(1): 100995, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38219955

RESUMO

Cardiovascular magnetic resonance (CMR) is a proven imaging modality for informing diagnosis and prognosis, guiding therapeutic decisions, and risk stratifying surgical intervention. Patients with a cardiac implantable electronic device (CIED) would be expected to derive particular benefit from CMR given high prevalence of cardiomyopathy and arrhythmia. While several guidelines have been published over the last 16 years, it is important to recognize that both the CIED and CMR technologies, as well as our knowledge in MR safety, have evolved rapidly during that period. Given increasing utilization of CIED over the past decades, there is an unmet need to establish a consensus statement that integrates latest evidence concerning MR safety and CIED and CMR technologies. While experienced centers currently perform CMR in CIED patients, broad availability of CMR in this population is lacking, partially due to limited availability of resources for programming devices and appropriate monitoring, but also related to knowledge gaps regarding the risk-benefit ratio of CMR in this growing population. To address the knowledge gaps, this SCMR Expert Consensus Statement integrates consensus guidelines, primary data, and opinions from experts across disparate fields towards the shared goal of informing evidenced-based decision-making regarding the risk-benefit ratio of CMR for patients with CIEDs.


Assuntos
Consenso , Desfibriladores Implantáveis , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Valor Preditivo dos Testes , Humanos , Fatores de Risco , Medição de Risco , Imageamento por Ressonância Magnética/normas , Imageamento por Ressonância Magnética/efeitos adversos , Tomada de Decisão Clínica , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Cardiopatias/diagnóstico por imagem , Cardiopatias/terapia
3.
Eur Heart J ; 44(22): 2029-2042, 2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-36939851

RESUMO

AIMS: Chimeric antigen receptor T-cell therapy (CAR-T) harnesses a patient's immune system to target cancer. There are sparse existing data characterizing death outcomes after CAR-T-related cardiotoxicity. This study examines the association between CAR-T-related severe cardiovascular events (SCE) and mortality. METHODS AND RESULTS: From a multi-centre registry of 202 patients receiving anti-CD19 CAR-T, covariates including standard baseline cardiovascular and cancer parameters and biomarkers were collected. Severe cardiovascular events were defined as a composite of heart failure, cardiogenic shock, or myocardial infarction. Thirty-three patients experienced SCE, and 108 patients died during a median follow-up of 297 (interquartile range 104-647) days. Those that did and did not die after CAR-T were similar in age, sex, and prior anthracycline use. Those who died had higher peak interleukin (IL)-6 and ferritin levels after CAR-T infusion, and those who experienced SCE had higher peak IL-6, C-reactive protein (CRP), ferritin, and troponin levels. The day-100 and 1-year Kaplan-Meier overall mortality estimates were 18% and 43%, respectively, while the non-relapse mortality (NRM) cumulative incidence rates were 3.5% and 6.7%, respectively. In a Cox model, SCE occurrence following CAR-T was independently associated with increased overall mortality risk [hazard ratio (HR) 2.8, 95% confidence interval (CI) 1.6-4.7] after adjusting for age, cancer type and burden, anthracycline use, cytokine release syndrome grade ≥ 2, pre-existing heart failure, hypertension, and African American ancestry; SCEs were independently associated with increased NRM (HR 3.5, 95% CI 1.4-8.8) after adjusting for cancer burden. CONCLUSION: Chimeric antigen receptor T-cell therapy recipients who experience SCE have higher overall mortality and NRM and higher peak levels of IL-6, CRP, ferritin, and troponin.


Assuntos
Insuficiência Cardíaca , Neoplasias , Receptores de Antígenos Quiméricos , Humanos , Receptores de Antígenos Quiméricos/uso terapêutico , Interleucina-6 , Biomarcadores , Proteína C-Reativa , Troponina , Terapia Baseada em Transplante de Células e Tecidos
4.
Am Heart J ; 260: 113-123, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36934978

RESUMO

BACKGROUND: In the Posterior left pericardiotomy for the prevention of atrial fibrillation after cardiac surgery (PALACS) trial, posterior pericardiotomy was associated with a significant reduction in postoperative atrial fibrillation (POAF) after cardiac surgery. We aimed to investigate the mechanisms underlying this effect. METHODS: We included PALACS patients with available echocardiographic data (n = 387/420, 92%). We tested the hypotheses that the reduction in POAF with the intervention was associated with 1) a reduction in postoperative pericardial effusion and/or 2) an effect on left atrial size and function. Spline and multivariable logistic regression analyses were used. RESULTS: Most patients (n = 307, 79%) had postoperative pericardial effusions (anterior 68%, postero-lateral 51.9%). The incidence of postero-lateral effusion was significantly lower in patients undergoing pericardiotomy (37% vs 67%; P < .001). The median size of anterior effusion was comparable between patients with and without POAF (5.0 [IQR 3.0-7.0] vs 5.0 [IQR 3.0-7.5] mm; P = .42), but there was a nonsignificant trend towards larger postero-lateral effusion in the POAF group (5.0 [IQR 3.0-9.0] vs 4.0 [IQR 3.0-6.4] mm; P = .06). There was a non-linear association between postero-lateral effusion and POAF at a cut-off at 10 mm (OR 2.70; 95% CI 1.13, 6.47; P = .03) that was confirmed in multivariable analysis (OR 3.5, 95% CI 1.17, 10.58; P = 0.02). Left atrial dimension and function did not change significantly after posterior pericardiotomy. CONCLUSIONS: Reduction in postero-lateral pericardial effusion is a plausible mechanism for the effect of posterior pericardiotomy in reducing POAF. Measures to reduce postoperative pericardial effusion are a promising approach to prevent POAF.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Derrame Pericárdico , Humanos , Fibrilação Atrial/etiologia , Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/epidemiologia , Pericardiectomia/efeitos adversos , Pericardiectomia/métodos , Derrame Pericárdico/epidemiologia , Derrame Pericárdico/etiologia , Derrame Pericárdico/cirurgia , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle
5.
Anesthesiology ; 139(5): 602-613, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37552082

RESUMO

BACKGROUND: Detailed understanding of the association between intraoperative left atrial and left ventricular diastolic function and postoperative atrial fibrillation is lacking. In this post hoc analysis of the Posterior Left Pericardiotomy for the Prevention of Atrial Fibrillation after Cardiac Surgery (PALACS) trial, we aimed to evaluate the association of intraoperative left atrial and left ventricular diastolic function as assessed by transesophageal echocardiography (TEE) with postoperative atrial fibrillation. METHODS: PALACS patients with available intraoperative TEE data (n = 402 of 420; 95.7%) were included in this cohort study. We tested the hypotheses that preoperative left atrial size and function, left ventricular diastolic function, and their intraoperative changes were associated with postoperative atrial fibrillation. Normal left ventricular diastolic function was graded as 0 and with lateral e' velocity 10 cm/s or greater. Diastolic dysfunction was defined as lateral e' less than 10 cm/s using E/e' cutoffs of grade 1, E/e' 8 or less; grade, 2 E/e' 9 to 12; and grade 3, E/e' 13 or greater, along with two criteria based on mitral inflow and pulmonary wave flow velocities. RESULTS: A total of 230 of 402 patients (57.2%) had intraoperative diastolic dysfunction. Posterior pericardiotomy intervention was not significantly different between the two groups. A total of 99 of 402 patients (24.6%) developed postoperative atrial fibrillation. Patients who developed postoperative atrial fibrillation more frequently had abnormal left ventricular diastolic function compared to patients who did not develop postoperative atrial fibrillation (75.0% [n = 161 of 303] vs. 57.5% [n = 69 of 99]; P = 0.004). Of the left atrial size and function parameters, only delta left atrial area, defined as presternotomy minus post-chest closure measurement, was significantly different in the no postoperative atrial fibrillation versus postoperative atrial fibrillation groups on univariate analysis (-2.1 cm2 [interquartile range, -5.1 to 1.0] vs. 0.1 [interquartile range, -4.0 to 4.8]; P = 0.028). At multivariable analysis, baseline abnormal left ventricular diastolic function (odds ratio, 2.02; 95% CI, 1.15 to 3.63; P = 0.016) and pericardiotomy intervention (odds ratio, 0.46; 95% CI, 0.27 to 0.78, P = 0.004) were the only covariates independently associated with postoperative atrial fibrillation. CONCLUSIONS: Baseline preoperative left ventricular diastolic dysfunction on TEE, not left atrial size or function, is independently associated with postoperative atrial fibrillation. Further studies are needed to test if interventions aimed at optimizing intraoperative left ventricular diastolic function during cardiac surgery may reduce the risk of postoperative atrial fibrillation.

6.
J Cardiovasc Magn Reson ; 25(1): 21, 2023 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-36973744

RESUMO

Coronavirus disease 2019 (COVID-19) is an ongoing global pandemic that has affected nearly 600 million people to date across the world. While COVID-19 is primarily a respiratory illness, cardiac injury is also known to occur. Cardiovascular magnetic resonance (CMR) imaging is uniquely capable of characterizing myocardial tissue properties in-vivo, enabling insights into the pattern and degree of cardiac injury. The reported prevalence of myocardial involvement identified by CMR in the context of COVID-19 infection among previously hospitalized patients ranges from 26 to 60%. Variations in the reported prevalence of myocardial involvement may result from differing patient populations (e.g. differences in severity of illness) and the varying intervals between acute infection and CMR evaluation. Standardized methodologies in image acquisition, analysis, interpretation, and reporting of CMR abnormalities across would likely improve concordance between studies. This consensus document by the Society for Cardiovascular Magnetic Resonance (SCMR) provides recommendations on CMR imaging and reporting metrics towards the goal of improved standardization and uniform data acquisition and analytic approaches when performing CMR in patients with COVID-19 infection.


Assuntos
COVID-19 , Cardiopatias , Imageamento por Ressonância Magnética , Humanos , COVID-19/complicações , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Espectroscopia de Ressonância Magnética , Miocardite/diagnóstico por imagem , Valor Preditivo dos Testes , Cardiopatias/diagnóstico por imagem , Cardiopatias/etiologia
7.
J Cardiovasc Magn Reson ; 24(1): 73, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36539786

RESUMO

The global pandemic of coronavirus disease 2019 (COVID-19) caused by infection with severe acute respiratory suyndrome coronavirus 2 (SARS-CoV-2) is now entering its 4th year with little evidence of abatement. As of December 2022, the World Health Organization Coronavirus (COVID-19) Dashboard reported 643 million cumulative confirmed cases of COVID-19 worldwide and 98 million in the United States alone as the country with the highest number of cases. While pneumonia with lung injury has been the manifestation of COVID-19 principally responsible for morbidity and mortality, myocardial inflammation and systolic dysfunction though uncommon are well-recognized features that also associate with adverse prognosis. Given the broad swath of the population infected with COVID-19, the large number of affected professional, collegiate, and amateur athletes raises concern regarding the safe resumption of athletic activity (return to play, RTP) following resolution of infection. A variety of different testing combinations that leverage the electrocardiogram, echocardiography, circulating cardiac biomarkers, and cardiovascular magnetic resonance (CMR) imaging have been proposed and implemented to mitigate risk. CMR in particular affords high sensitivity for myocarditis but has been employed and interpreted non-uniformly in the context of COVID-19 thereby raising uncertainty as to the generalizability and clinical relevance of findings with respect to RTP. This consensus document synthesizes available evidence to contextualize the appropriate utilization of CMR in the RTP assessment of athletes with prior COVID-19 infection to facilitate informed, evidence-based decisions, while identifying knowledge gaps that merit further investigation.


Assuntos
COVID-19 , Miocardite , Esportes , Humanos , American Heart Association , Consenso , Liderança , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Miocardite/diagnóstico por imagem , Valor Preditivo dos Testes , SARS-CoV-2 , Estados Unidos , Sociedades Médicas
8.
J Cardiovasc Magn Reson ; 24(1): 42, 2022 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-35787291

RESUMO

The Society for Cardiovascular Magnetic Resonance (SCMR) is an international society focused on the research, education, and clinical application of cardiovascular magnetic resonance (CMR). "Cases of SCMR" is a case series hosted on the SCMR website ( https://www.scmr.org ) that demonstrates the utility and importance of CMR in the clinical diagnosis and management of cardiovascular disease. The COVID-19 Case Collection highlights the impact of coronavirus disease 2019 (COVID-19) on the heart as demonstrated on CMR. Each case in series consists of the clinical presentation and the role of CMR in diagnosis and guiding clinical management. The cases are all instructive and helpful in the approach to patient management. We present a digital archive of the 2021 Cases of SCMR and the 2020 and 2021 COVID-19 Case Collection series of nine cases as a means of further enhancing the education of those interested in CMR and as a means of more readily identifying these cases using a PubMed or similar literature search engine.


Assuntos
COVID-19 , Sistema Cardiovascular , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
9.
J Cardiothorac Vasc Anesth ; 36(5): 1279-1287, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34600832

RESUMO

OBJECTIVES: Three-dimensional transesophageal echocardiography (TEE) is widely used to guide decision-making for mitral repair. The relative impact of surgical mitral valve repair (MVr) and MitraClip on annular remodeling is unknown. The aim was to determine the impact of both mitral repair strategies on annular geometry, including the primary outcome of annular circumference and area. DESIGN: This was a retrospective observational study of patients who underwent mitral intervention between 2016 and 2020. SETTING: Weill Cornell Medicine, a single, large, academic medical center. PARTICIPANTS: The population comprised 50 patients with degenerative mitral regurgitation (MR) undergoing MVr. INTERVENTIONS: Elective MVr and TEE. MEASUREMENTS AND MAIN RESULTS: Patients undergoing MitraClip or surgical MVr were matched (1:1) for sex and coronary artery disease. Mitral annular geometry indices were quantified on intraprocedural three-dimensional TEE. Mild or less MR on follow-up transthoracic echocardiography defined optimal response. Patients undergoing MitraClip were older (80 ± eight v 66 ± six years; p < 0.001) but were otherwise similar to surgical patients. Patients undergoing MitraClip had larger baseline left atrial and ventricular sizes, increased tenting height, and volume (p < 0.01), with a trend toward increased annular area (p = 0.23). MitraClip and surgery both induced immediate mitral annular remodeling, including decreased area, circumference, and tenting height (p < 0.001), with greater remodeling with surgical repair. At follow-up (4.1 ± 9.0 months) optimal response (≤ mild MR) was ∼twofold more common with surgery than MitraClip (81% v 46%; p = 0.02). The relative reduction in annular circumference (odds ratio [OR] 1.05 [1.00-1.09] per cm; p = 0.04) and area (OR 1.03 [1.00-1.05] per cm2; p = 0.049) were both associated with optimal response. CONCLUSIONS: Surgical MVr and MitraClip both reduce annular size, but repair-induced remodeling is greater with surgery and associated with an increased likelihood of optimal response.


Assuntos
Ecocardiografia Tridimensional , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
10.
J Cardiothorac Vasc Anesth ; 36(8 Pt A): 2412-2417, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34903459

RESUMO

OBJECTIVE: Whereas left atrial (LA) strain has been well-validated using transthoracic echocardiography (TTE), its detection using transesophageal echocardiography (TEE) has not been studied. Conventional transesophageal views are known to be limited due to the posterior location of the LA. Here, the feasibility and accuracy of the deep transgastric long-axis LA focused view for peak atrial longitudinal strain (PALS) quantification was tested. DESIGN: This was a retrospective study of patients who underwent elective cardiac surgery between 2018 and 2020. TEE deep transgastric long-axis view was compared to TTE 4-chamber atrial focused view as the reference standard. LA area, volume, and PALS were quantified independently. SETTING: At Weill Cornell Medicine, a single, large academic medical center. PARTICIPANTS: The population comprised 42 patients undergoing cardiac surgery who had a TTE and TEE within 14.9 ± 20.8 days. INTERVENTIONS: TTE, TEE, and cardiac surgery. MEASUREMENTS AND MAIN RESULTS: TEE-derived PALS strongly correlated with TTE- derived PALS (r = 0.92, p < 0.001), though absolute PALS were lower (20.7 ± 6.0% v 25.7 ± 6.8%; p < 0.001). Mean TEE-derived atrial length was similar to TTE-derived length (5.18 ± 0.61 cm v 5.24 ± 0.61 cm; p = 0.38), but mean LA area was significantly smaller (16.7 ± 3.5 cm2v 18.9 ± 3.7 cm2; p < 0.001), with significant correlations between the 2 modalities for both (r = 0.74, 0.74, respectively; all p < 0.001). CONCLUSION: This exploratory study supported the feasibility of TEE for assessing LA longitudinal strain. There was an excellent correlation between atrial strain derived via TEE versus TTE, although values tended to be smaller on TEE, and bias between values was highly variable, suggesting that the values were not interchangeable.


Assuntos
Apêndice Atrial , Ecocardiografia Transesofagiana , Ecocardiografia , Átrios do Coração/diagnóstico por imagem , Humanos , Estudos Retrospectivos
11.
J Card Surg ; 37(12): 4138-4143, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36321961

RESUMO

This dialog between a cardiac surgeon (C.L.) and cardiac imager (J.W.W.) provides an overview of cardiac MRI (CMR) methods relevant to cardiac surgery. Major areas of focus include logistics of performing a CMR exam, as well as established and emerging methods for assessment of cardiac structure, function, valvular performance, and tissue characterization. Regarding tissue characterization, a major area of focus concerns CMR assessment of viability, for which this modality has been shown to provide incremental utility to conventional techniques for detection of presence and transmural extent of infarction, as well as powerful predictive utility of recovery of left ventricular systolic function as well as long term clinical prognosis in patients with an array of clinical conditions, including coronary artery disease and valvular heart disease both before and following cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Doença da Artéria Coronariana , Humanos , Coração , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes
12.
Magn Reson Med ; 86(4): 2105-2121, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34096083

RESUMO

PURPOSE: Myocardial strain is increasingly used to assess left ventricular (LV) function. Incorporation of LV deformation into finite element (FE) modeling environment with subsequent strain calculation will allow analysis to reach its full potential. We describe a new kinematic model-based analysis framework (KMAF) to calculate strain from 3D cine-DENSE (displacement encoding with stimulated echoes) MRI. METHODS: Cine-DENSE allows measurement of 3D myocardial displacement with high spatial accuracy. The KMAF framework uses cine cardiovascular magnetic resonance (CMR) to facilitate cine-DENSE segmentation, interpolates cine-DENSE displacement, and kinematically deforms an FE model to calculate strain. This framework was validated in an axially compressed gel phantom and applied in 10 healthy sheep and 5 sheep after myocardial infarction (MI). RESULTS: Excellent Bland-Altman agreement of peak circumferential (Ecc ) and longitudinal (Ell ) strain (mean difference = 0.021 ± 0.04 and -0.006 ± 0.03, respectively), was found between KMAF estimates and idealized FE simulation. Err had a mean difference of -0.014 but larger variation (±0.12). Cine-DENSE estimated end-systolic (ES) Ecc , Ell and Err exhibited significant spatial variation for healthy sheep. Displacement magnitude was reduced on average by 27%, 42%, and 56% after MI in the remote, adjacent and MI regions, respectively. CONCLUSIONS: The KMAF framework allows accurate calculation of 3D LV Ecc and Ell from cine-DENSE.


Assuntos
Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio , Animais , Fenômenos Biomecânicos , Infarto do Miocárdio/diagnóstico por imagem , Reprodutibilidade dos Testes , Ovinos , Função Ventricular Esquerda
13.
Eur Radiol ; 31(4): 2013-2021, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33048226

RESUMO

OBJECTIVES: To evaluate the utility of perfusion defects on dual-energy CT angiograms (DECTA) in assessing the clinical severity of pulmonary embolism (PE). METHODS: We retrospectively reviewed 1136 consecutive diagnostic DECTA exams performed on patients with suspected PE between January 2014 and September 2014. Presence and location of obstructive and non-obstructive PE, right ventricular to left ventricular ratio (RV/LV ratio), and inferior vena cava (IVC) backflow were recorded. Iodine maps were reviewed to establish the presence of perfusion defect and its extent was determined through a score-based segmental impaired perfusion. Subsequently, the perfusion defect scores were correlated with clinical parameters including vital signs, electrocardiogram (ECG) abnormalities, echocardiogram findings, troponin, and brain natriuretic peptide (bnp) levels. Clinical information regarding primary cancer diagnosis, oncologic stage, and date of death if applicable was also recorded. RESULTS: Of the 1136 diagnostic iodine maps, 96 of these patients had perfusion defects on iodine maps. After uni- and multivariate analysis, significant correlation was found between the presence of a perfusion defect and RV/LV ratio (p = 0.05), IVC backflow (p = 0.03), elevated troponin (p = 0.03), and right heart dysfunction as determined on an echocardiogram (p = 0.05). The greater the perfusion defect score, the higher the likelihood of IVC backflow (p = 0.005) and obstructive PE (p = 0.002). When adjusted for oncologic stage, patients with a perfusion defect and a higher perfusion defect score had a higher mortality rate (p = 0.005). CONCLUSION: The presence of a perfusion defect correlates with several parameters evaluating PE severity. A perfusion defect and higher perfusion defect score were associated with a lower survival. KEY POINTS: • Detection of perfusion defects on dual-energy CT angiograms and its extent correlates with right heart strain in the setting of pulmonary embolism. • The presence and extent of a perfusion defect in patients with pulmonary embolism are associated with lower survival.


Assuntos
Embolia Pulmonar , Disfunção Ventricular Direita , Angiografia , Humanos , Perfusão , Embolia Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Disfunção Ventricular Direita/diagnóstico por imagem
14.
J Cardiovasc Magn Reson ; 23(1): 42, 2021 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-33814005

RESUMO

BACKGROUND: Late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) is widely used to identify cardiac neoplasms, for which diagnosis is predicated on enhancement stemming from lesion vascularity: Impact of contrast-enhancement pattern on clinical outcomes is unknown. The objective of this study was to determine whether cardiac metastasis (CMET) enhancement pattern on LGE-CMR impacts prognosis, with focus on heterogeneous lesion enhancement as a marker of tumor avascularity. METHODS: Advanced (stage IV) systemic cancer patients with and without CMET matched (1:1) by cancer etiology underwent a standardized CMR protocol. CMET was identified via established LGE-CMR criteria based on lesion enhancement; enhancement pattern was further classified as heterogeneous (enhancing and non-enhancing components) or diffuse and assessed via quantitative (contrast-to-noise ratio (CNR); signal-to-noise ratio (SNR)) analyses. Embolic events and mortality were tested in relation to lesion location and contrast-enhancement pattern. RESULTS: 224 patients were studied, including 112 patients with CMET and unaffected (CMET -) controls matched for systemic cancer etiology/stage. CMET enhancement pattern varied (53% heterogeneous, 47% diffuse). Quantitative analyses were consistent with lesion classification; CNR was higher and SNR lower in heterogeneously enhancing CMET (p < 0.001)-paralleled by larger size based on linear dimensions (p < 0.05). Contrast-enhancement pattern did not vary based on lesion location (p = NS). Embolic events were similar between patients with diffuse and heterogeneous lesions (p = NS) but varied by location: Patients with right-sided lesions had threefold more pulmonary emboli (20% vs. 6%, p = 0.02); those with left-sided lesions had lower rates equivalent to controls (4% vs. 5%, p = 1.00). Mortality was higher among patients with CMET (hazard ratio [HR] = 1.64 [CI 1.17-2.29], p = 0.004) compared to controls, but varied by contrast-enhancement pattern: Diffusely enhancing CMET had equivalent mortality to controls (p = 0.21) whereas prognosis was worse with heterogeneous CMET (p = 0.005) and more strongly predicted by heterogeneous enhancement (HR = 1.97 [CI 1.23-3.15], p = 0.005) than lesion size (HR = 1.11 per 10 cm [CI 0.53-2.33], p = 0.79). CONCLUSIONS: Contrast-enhancement pattern and location of CMET on CMR impacts prognosis. Embolic events vary by CMET location, with likelihood of PE greatest with right-sided lesions. Heterogeneous enhancement-a marker of tumor avascularity on LGE-CMR-is a novel marker of increased mortality risk.


Assuntos
Meios de Contraste , Neoplasias Cardíacas/irrigação sanguínea , Neoplasias Cardíacas/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Meglumina , Células Neoplásicas Circulantes/patologia , Compostos Organometálicos , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Neoplasias Cardíacas/mortalidade , Neoplasias Cardíacas/secundário , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Cidade de Nova Iorque , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Fatores de Risco
15.
J Cardiothorac Vasc Anesth ; 35(9): 2707-2714, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33223382

RESUMO

OBJECTIVES: Aortic valve replacement (AVR) potentially can modify pulse-wave propagation to the distal aorta. Echo-derived global circumferential strain (GCS) was used to test whether AVR for aortic stenosis (AS) or aortic insufficiency (AI) resulted in differential aortic biomechanics in the descending thoracic aorta. DESIGN: This was a prospective observational study of patients who underwent cardiac surgery between 2016 and 2019. SETTING: Weill Cornell Medicine, a single large academic medical center. PARTICIPANTS: The population comprised 48 patients undergoing AVR (62 ± 15 y/o, 79% male; 22 with AI and 26 with AS) and 11 patients undergoing coronary bypass surgery as controls. INTERVENTIONS: Elective cardiac surgery, transesophageal echocardiography (TEE), pulmonary artery catheter. MEASUREMENTS AND MAIN RESULTS: Pre- and postprocedural TEEs were collected. Descending aorta short-axis images were analyzed for GCS, time-to-peak strain, aortic end-diastolic, end-systolic area, and fractional area changes. Pulse pressure (PP) and stroke volume were quantified. Preprocedural GCS significantly differed between patients with AI and AS, with AI patients having greater GCS (median/interquartile range, 9.6 95.3,13.6) than patients with AS (4.3 [3.4-5.1]). After AVR, in AI patients, strain significantly decreased (5.5 [3.8,8.2], p = 0.001), along with PP (mean ± standard deviation) (66.4 ± 0.8 to 54.1 ± 13.7, p < 0.001), and PP corrected strain did not (GCS/PP = 14.8 [6.9-19.9] v 12.7[8.2-18.6], p = 0.34). In AS patients, GCS significantly increased after AVR to (5.45 [4.2-6.8], p = 0.003), as did PP-corrected strain (6.9 [5.8-9.2] v 9.7 [6.5-13.4], p = 0.016). Surgical AVR produced decrements in time-to-peak strain in AI and AS groups (both p < 0.001). CONCLUSIONS: After AVR for AI and AS, the direction of change in distal aortic strain from baseline depends on valve pathology. This finding may have important clinical implications in terms of indication for surgery and postoperative surveillance, especially in patients with aortopathies.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Aorta , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Resultado do Tratamento
16.
Eur Heart J ; 41(18): 1733-1743, 2020 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-32112560

RESUMO

AIMS: Myocarditis is a potentially fatal complication of immune checkpoint inhibitors (ICI). Sparse data exist on the use of cardiovascular magnetic resonance (CMR) in ICI-associated myocarditis. In this study, the CMR characteristics and the association between CMR features and cardiovascular events among patients with ICI-associated myocarditis are presented. METHODS AND RESULTS: From an international registry of patients with ICI-associated myocarditis, clinical, CMR, and histopathological findings were collected. Major adverse cardiovascular events (MACE) were a composite of cardiovascular death, cardiogenic shock, cardiac arrest, and complete heart block. In 103 patients diagnosed with ICI-associated myocarditis who had a CMR, the mean left ventricular ejection fraction (LVEF) was 50%, and 61% of patients had an LVEF ≥50%. Late gadolinium enhancement (LGE) was present in 48% overall, 55% of the reduced EF, and 43% of the preserved EF cohort. Elevated T2-weighted short tau inversion recovery (STIR) was present in 28% overall, 30% of the reduced EF, and 26% of the preserved EF cohort. The presence of LGE increased from 21.6%, when CMR was performed within 4 days of admission to 72.0% when CMR was performed on Day 4 of admission or later. Fifty-six patients had cardiac pathology. Late gadolinium enhancement was present in 35% of patients with pathological fibrosis and elevated T2-weighted STIR signal was present in 26% with a lymphocytic infiltration. Forty-one patients (40%) had MACE over a follow-up time of 5 months. The presence of LGE, LGE pattern, or elevated T2-weighted STIR were not associated with MACE. CONCLUSION: These data suggest caution in reliance on LGE or a qualitative T2-STIR-only approach for the exclusion of ICI-associated myocarditis.


Assuntos
Inibidores de Checkpoint Imunológico , Miocardite , Meios de Contraste , Gadolínio , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Miocardite/induzido quimicamente , Valor Preditivo dos Testes , Volume Sistólico , Função Ventricular Esquerda
17.
Stroke ; 51(9): e203-e210, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32781943

RESUMO

BACKGROUND AND PURPOSE: One-fifth of ischemic strokes are embolic strokes of undetermined source (ESUS). Their theoretical causes can be classified as cardioembolic versus noncardioembolic. This distinction has important implications, but the categories' proportions are unknown. METHODS: Using data from the Cornell Acute Stroke Academic Registry, we trained a machine-learning algorithm to distinguish cardioembolic versus non-cardioembolic strokes, then applied the algorithm to ESUS cases to determine the predicted proportion with an occult cardioembolic source. A panel of neurologists adjudicated stroke etiologies using standard criteria. We trained a machine learning classifier using data on demographics, comorbidities, vitals, laboratory results, and echocardiograms. An ensemble predictive method including L1 regularization, gradient-boosted decision tree ensemble (XGBoost), random forests, and multivariate adaptive splines was used. Random search and cross-validation were used to tune hyperparameters. Model performance was assessed using cross-validation among cases of known etiology. We applied the final algorithm to an independent set of ESUS cases to determine the predicted mechanism (cardioembolic or not). To assess our classifier's validity, we correlated the predicted probability of a cardioembolic source with the eventual post-ESUS diagnosis of atrial fibrillation. RESULTS: Among 1083 strokes with known etiologies, our classifier distinguished cardioembolic versus noncardioembolic cases with excellent accuracy (area under the curve, 0.85). Applied to 580 ESUS cases, the classifier predicted that 44% (95% credibility interval, 39%-49%) resulted from cardiac embolism. Individual ESUS patients' predicted likelihood of cardiac embolism was associated with eventual atrial fibrillation detection (OR per 10% increase, 1.27 [95% CI, 1.03-1.57]; c-statistic, 0.68 [95% CI, 0.58-0.78]). ESUS patients with high predicted probability of cardiac embolism were older and had more coronary and peripheral vascular disease, lower ejection fractions, larger left atria, lower blood pressures, and higher creatinine levels. CONCLUSIONS: A machine learning estimator that distinguished known cardioembolic versus noncardioembolic strokes indirectly estimated that 44% of ESUS cases were cardioembolic.


Assuntos
Embolia Intracraniana/patologia , Aprendizado de Máquina , Acidente Vascular Cerebral/patologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Fibrilação Atrial/complicações , Árvores de Decisões , Eletrocardiografia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Embolia Intracraniana/complicações , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Sistema de Registros , Reprodutibilidade dos Testes , Acidente Vascular Cerebral/etiologia
18.
J Cardiovasc Magn Reson ; 22(1): 61, 2020 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-32878639

RESUMO

The aim of this document is to provide specific recommendations on the use of cardiovascular magnetic resonance (CMR) protocols in the era of the COVID-19 pandemic. In patients without COVID-19, standard CMR protocols should be used based on clinical indication as usual. Protocols used in patients who have known / suspected active COVID-19 or post COVID-19 should be performed based on the specific clinical question with an emphasis on cardiac function and myocardial tissue characterization. Short and dedicated protocols are recommended.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Infecções por Coronavirus/prevenção & controle , Controle de Infecções/organização & administração , Imagem Cinética por Ressonância Magnética/normas , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Guias de Prática Clínica como Assunto , COVID-19 , Infecções por Coronavirus/epidemiologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pandemias/estatística & dados numéricos , Pneumonia Viral/epidemiologia , Índice de Gravidade de Doença , Sociedades Médicas , Estados Unidos
19.
Echocardiography ; 37(5): 688-697, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32396705

RESUMO

PURPOSE: Echocardiography (echo) is widely used for right ventricular (RV) assessment. Current techniques for RV evaluation require additional imaging and manual analysis; machine learning (ML) approaches have the potential to provide efficient, fully automated quantification of RV function. METHODS: An automated ML model was developed to track the tricuspid annulus on echo using a convolutional neural network approach. The model was trained using 7791 image frames, and automated linear and circumferential indices quantifying annular displacement were generated. Automated indices were compared to an independent reference of cardiac magnetic resonance (CMR) defined RV dysfunction (RVEF < 50%). RESULTS: A total of 101 patients prospectively underwent echo and CMR: Fully automated annular tracking was uniformly successful; analyses entailed minimal processing time (<1 second for all) and no user editing. Findings demonstrate all automated annular shortening indices to be lower among patients with CMR-quantified RV dysfunction (all P < .001). Magnitude of ML annular displacement decreased stepwise in relation to population-based tertiles of TAPSE, with similar results when ML analyses were localized to the septal or lateral annulus (all P ≤ .001). Automated segmentation techniques provided good diagnostic performance (AUC 0.69-0.73) in relation to CMR reference and compared to conventional RV indices (TAPSE and S') with high negative predictive value (NPV 84%-87% vs 83%-88%). Reproducibility was higher for ML algorithm as compared to manual segmentation with zero inter- and intra-observer variability and ICC 1.0 (manual ICC: 0.87-0.91). CONCLUSIONS: This study provides an initial validation of a deep learning system for RV assessment using automated tracking of the tricuspid annulus.


Assuntos
Imagem Cinética por Ressonância Magnética , Disfunção Ventricular Direita , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Aprendizado de Máquina , Reprodutibilidade dos Testes , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita
20.
Echocardiography ; 37(11): 1820-1827, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32909633

RESUMO

BACKGROUND: Whereas cardiac magnetic resonance (CMR) imaging provides high temporal resolution imaging of aortic distensibility (strain), transesophageal echocardiography (TEE) is widely used for intra-operative aortic imaging and provides a clinical alternative for aortic assessment. We tested intra-operative global circumferential aortic strain (GCS) measured on TEE in relation to the reference of CMR-derived strain among patients undergoing surgical graft repair of ascending aortic aneurysms. METHODS: CMR (3T) was prospectively performed in patients scheduled for aortic repair. TEE was performed intra-operatively; images were co-localized with MRI. GCS on CMR and TEE was quantified independently, blinded to results of the other modality. RESULTS: 25 patients (54 ± 10 year-old, 88% male) were studied, inclusive of 13 genetically mediated and 12 degenerative aneurysms: CMR and TEE were performed within 12 ± 9 days. Pulse pressure (PP)-adjusted descending aortic TEE-derived GCS strongly correlated with cine-CMR-derived GCS (r = .75, P = .002) though absolute GCS and PP-adjusted values were slightly lower (5.40 ± 1.11 vs 6.49 ± 1.43% and 11.55 ± 3.04 vs 13.99 ± 4.53%, respectively). Similarly, TEE yielded slightly lower end-diastolic area (EDA [5.1 ± 1.7 cm2 vs 5.8 ± 1.3 cm2 , P = .004]) and end-systolic area (ESA [6.1 ± 1.9 cm2 vs 6.5 ± 1.7 cm2 , P = .10]), with significant correlations between the two modalities (r = .73, .76, P < .05 for all). CONCLUSIONS: This exploratory study supports feasibility of TEE for assessing aortic GCS in a surgical at-risk population, as well as magnitude of agreement between intra-operative TEE and preoperative CMR. We found that there is a significant correlation between GCS and EDA and ESA aortic areas, but that TEE-derived parameters underestimated CMR values by a small but significant amount.


Assuntos
Ecocardiografia Transesofagiana , Ecocardiografia , Adulto , Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA