Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Am J Audiol ; 14(2): S178-85, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16489862

RESUMO

PURPOSE: This article is the 1st in a series of 4 articles on a recently completed multistate study of newborn hearing screening. METHOD: The study examined the efficacy of the 2-stage otoacoustic emission/automated auditory brainstem response (OAE/A-ABR) protocol for identifying hearing loss in newborns. RESULTS: The study found that the 2-stage OAE/A-ABR protocol did miss a significant number of babies who exhibited a permanent hearing loss by 1 year of age. Three subsequent articles will describe the research design and results in detail, discuss the behavioral assessment of infants, and summarize the implications of the study for policy, practice, and research.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Perda Auditiva/diagnóstico , Triagem Neonatal/métodos , Emissões Otoacústicas Espontâneas , Humanos , Recém-Nascido , Reprodutibilidade dos Testes , Estados Unidos
2.
Am J Audiol ; 14(2): S186-199, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16489863

RESUMO

PURPOSE: Most newborns are screened for hearing loss, and many hospitals use a 2-stage protocol in which all infants are screened first with otoacoustic emissions (OAEs). In this protocol, no additional testing is done for those passing the OAE screening, but infants failing the OAE are also screened with automated auditory brainstem response (A-ABR). This study evaluated how many infants who failed the OAE and passed the A-ABR had permanent hearing loss (PHL) at 8-12 months of age. METHOD: A total of 86,634 infants were screened at 7 birthing centers using a 2-stage OAE/A-ABR hearing screening protocol. Of infants who failed the OAE but passed the A-ABR, 1,524 were enrolled in the study. Diagnostic audiologic evaluations were performed on 64% of the enrolled infants (1,432 ears from 973 infants) when they were 8-12 months old. RESULTS: Twenty-one infants (30 ears) who passed the newborn A-ABR hearing screening were identified with PHL when they were 8-12 months old. Most (71%) had mild hearing loss. CONCLUSIONS: If all infants were screened for hearing loss using a typical 2-stage OAE/A-ABR protocol, approximately 23% of those with PHL at 8-12 months of age would have passed the A-ABR.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Perda Auditiva/diagnóstico , Triagem Neonatal/métodos , Emissões Otoacústicas Espontâneas , Projetos de Pesquisa , Feminino , Seguimentos , Perda Auditiva/congênito , Perda Auditiva/epidemiologia , Humanos , Lactente , Recém-Nascido , Masculino , Prevalência , Reprodutibilidade dos Testes , Estados Unidos/epidemiologia
3.
Am J Audiol ; 14(2): S200-16, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16489864

RESUMO

PURPOSE: This 3rd of 4 articles on a study of the efficacy of the 2-stage otoacoustic emission/automated auditory brainstem response (OAE/A-ABR) newborn hearing screening protocol describes (a) the behavioral audiometric protocol used to validate hearing status at 8-12 months of age, (b) the hearing status of the sample, and (c) the success of the visual reinforcement audiometry (VRA) protocol across 7 sites. METHOD: A total of 973 infants who failed OAE but passed A-ABR, in one or both ears, during newborn screening were tested with a VRA protocol, supplemented by tympanometry and OAE screening at age 8-12 months. RESULTS: VRA audiograms (1.0, 2.0, and 4.0 kHz) were obtained for 1,184 (82.7%) of the 1,432 study ears. Hearing loss was ruled out in another 100 ears by VRA in combination with OAE, for a total of 88.7% of the study sample. Permanent hearing loss was identified in 30 ears of 21 infants. Sites differed in their success with the VRA protocol. CONCLUSIONS: Continued monitoring of hearing beyond the newborn period is an important component of early detection of hearing loss. Using a structured protocol, VRA is an appropriate test method for most, but not all, infants. A battery of test procedures is often needed to adequately delineate hearing loss in infants. Examiner experience appears to be a factor in successful VRA.


Assuntos
Audiometria/métodos , Potenciais Evocados Auditivos do Tronco Encefálico , Perda Auditiva/diagnóstico , Triagem Neonatal/métodos , Emissões Otoacústicas Espontâneas , Testes de Impedância Acústica , Atenção , Feminino , Seguimentos , Perda Auditiva/congênito , Perda Auditiva/epidemiologia , Humanos , Lactente , Recém-Nascido , Masculino , Estimulação Luminosa , Prevalência , Reforço Psicológico , Reprodutibilidade dos Testes , Estados Unidos/epidemiologia
4.
Am J Audiol ; 14(2): S217-28, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16489865

RESUMO

PURPOSE: This article examines whether changes in hearing screening practices are warranted based on the results of the recent series of studies by J. L. Johnson, K. R. White, J. E. Widen, J. S. Gravel, B. R. Vohr, M. James, T. Kennalley, A. B. Maxon, L. Spivak, M. Sullivan-Mahoney, Y. Weirather, and S. Meyer (Johnson, White, Widen, Gravel, James, et al., 2005; Johnson, White, Widen, Gravel, Vohr, et al., 2005; White et al., 2005; Widen et al., 2005) that found a significant number of infants who passed an automated auditory brainstem response (A-ABR) screening after failing an initial otoacoustic emission (OAE) screening later were found to have permanent hearing loss in one or both ears. METHOD: Similar to the approach used by F. H. Bess and J. Paradise (1994), this article addresses the public health tenets that need to be in place before screening programs, or in this case, a change in screening practice (use of a 2-step screening protocol) can be justified. RESULTS: There are no data to suggest that a 2-step OAE/A-ABR screening protocol should be avoided. CONCLUSION: Research is needed before any change in public policy and practice surrounding current early hearing detection and intervention programs could be supported.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Perda Auditiva/diagnóstico , Perda Auditiva/terapia , Triagem Neonatal/métodos , Emissões Otoacústicas Espontâneas , Correção de Deficiência Auditiva , Análise Custo-Benefício , Intervenção Educacional Precoce , Feminino , Seguimentos , Perda Auditiva/epidemiologia , Humanos , Lactente , Recém-Nascido , Masculino , Triagem Neonatal/economia , Triagem Neonatal/normas , Valor Preditivo dos Testes , Prevalência , Reprodutibilidade dos Testes , Estados Unidos/epidemiologia
5.
Hawaii Med J ; 61(2): 26-30, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11892381

RESUMO

This article describes the importance of early identification of hearing loss in newborns, the current status of newborn hearing screening in the United States, and the leadership that Hawaii has contributed to that effort. Described are events that may help the nation reach the Year 2010 Health Goals for newborn hearing screening, identification, and intervention.


Assuntos
Surdez/diagnóstico , Triagem Neonatal/organização & administração , Objetivos Organizacionais , Planos Governamentais de Saúde , Havaí , Prioridades em Saúde , Testes Auditivos/estatística & dados numéricos , Humanos , Recém-Nascido , Triagem Neonatal/normas , Triagem Neonatal/estatística & dados numéricos , Estados Unidos
6.
Pediatrics ; 116(3): 663-72, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16140706

RESUMO

OBJECTIVE: Ninety percent of all newborns in the United States are now screened for hearing loss before they leave the hospital. Many hospitals use a 2-stage protocol for newborn hearing screening in which all infants are screened first with otoacoustic emissions (OAE). No additional testing is done with infants who pass the OAE, but infants who fail the OAE next are screened with automated auditory brainstem response (A-ABR). Infants who fail the A-ABR screening are referred for diagnostic testing to determine whether they have permanent hearing loss (PHL). Those who pass the A-ABR are considered at low risk for hearing loss and are not tested further. The objective of this multicenter study was to determine whether a substantial number of infants who fail the initial OAE and pass the A-ABR have PHL at approximately 9 months of age. METHODS: Seven birthing centers with successful newborn hearing screening programs using a 2-stage OAE/A-ABR screening protocol participated. During the study period, 86634 infants were screened for hearing loss at these sites. Of those infants who failed the OAE but passed the A-ABR in at least 1 ear, 1524 were enrolled in the study. Data about prenatal, neonatal, and socioeconomic factors, plus hearing loss risk indicators, were collected for all enrolled infants. When the infants were an average of 9.7 months of age, diagnostic audiologic evaluations were done for 64% of the enrolled infants (1432 ears from 973 infants). RESULTS: Twenty-one infants (30 ears) who had failed the OAE but passed the A-ABR during the newborn hearing screening were identified with permanent bilateral or unilateral hearing loss. Twenty-three (77%) of the ears had mild hearing loss (average of 1 kHz, 2 kHz, and 4 kHz < or =40-decibel hearing level). Nine (43%) infants had bilateral as opposed to unilateral loss, and 18 (86%) infants had sensorineural as opposed to permanent conductive hearing loss. CONCLUSIONS: If all infants were screened for hearing loss using the 2-stage OAE/A-ABR newborn hearing screening protocol currently used in many hospitals, then approximately 23% of those with PHL at approximately 9 months of age would have passed the A-ABR. This happens in part because much of the A-ABR screening equipment in current use was designed to identify infants with moderate or greater hearing loss. Thus, program administrators should be certain that the screening program, equipment, and protocols are designed to identify the type of hearing loss targeted by their program. The results also show the need for continued surveillance of hearing status during childhood.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Perda Auditiva/diagnóstico , Triagem Neonatal , Emissões Otoacústicas Espontâneas , Audiometria de Resposta Evocada , Seguimentos , Perda Auditiva/congênito , Humanos , Lactente , Recém-Nascido
7.
Pediatrics ; 111(5 Pt 2): 1202-6, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12728139

RESUMO

OBJECTIVE: Universal Newborn Hearing Screening began in 2 Honolulu hospitals in 1992, and by 1999, all 14 civilian birthing facilities in Hawaii were providing screening. Examination of 1998 Hawaii data indicated that approximately 13% of infants who did not pass initial hearing screening in the hospital did not return for the indicated follow-up. The purpose of this study was to determine the epidemiologic profile of infants who were born in 1999 and did not return for follow-up. METHODS: A population-based, cohort study of the hearing screening completion rates among the 13 civilian birthing facilities in Hawaii that provided data to the Department of Health was conducted. Analysis included a bivariate analysis of the demographic characteristics of infants who completed the screening/follow-up process compared with those who did not and logistic regression modeling to ascertain the demographic profile of infants at high risk for being lost to follow-up. RESULTS: Of 12 456 infants, hearing screening data could be linked to the birth certificate file, and a final disposition regarding completion of the screening/follow-up process was determined for 10 328 (83%). Less than 2% (n = 176) of the linked infants failed to complete the screening/follow-up procedures. Low birth weight and white infants and infants born to women who had not completed high school were approximately twice as likely not to complete the screening as were their normal birth weight or nonwhite counterparts. CONCLUSIONS: Failure to complete the hearing screening follow-up may be related to cultural differences that have been previously reported in other maternal and child health studies of the diverse populations in Hawaii. The results of this study will allow the Hawaii Newborn Hearing Screening Program to target its efforts and limited resources toward infants who are at higher risk of not completing the screening and who may need special attention to encourage their mothers to complete the screening process, and to move quickly with rescreening infants whose initial tests are positive so that infants are not lost to follow-up.


Assuntos
Audiometria de Resposta Evocada/estatística & dados numéricos , Perda Auditiva/diagnóstico , Triagem Neonatal/estatística & dados numéricos , Estudos de Coortes , Havaí , Humanos , Recém-Nascido , Razão de Chances , Avaliação de Programas e Projetos de Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA