Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am J Emerg Med ; 67: 194.e7-194.e10, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36997382

RESUMO

The Electrocardiogram (ECG) is a readily available non-invasive test used in the evaluation of a patient with angina. ECG artifacts are common and stem from a number of different reasons including lead placement and must be identified to appropriately manage patients. We present the case of an elderly patient for whom an ECG was performed to evaluate chest pain showing an abnormal waveform concerning for an ST elevation myocardial infarction (STEMI). Closer inspection of the ECG revealed a characteristic pattern documented in the literature known as Aslanger's Sign seen when an ECG lead is placed over an artery.


Assuntos
Artefatos , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Idoso , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Eletrocardiografia , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Angina Pectoris
2.
J Cardiothorac Vasc Anesth ; 36(1): 236-241, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33745836

RESUMO

Perioperative management of implantable cardioverter-defibrillators is an important part of anesthetic care. Society recommendations and expert consensus statements exist to aid clinicians, and they have identified the umbilicus as an important landmark in decision-making. Implantable cardioverter-defibrillator antitachycardia therapy may not need to be deactivated for infraumbilical surgery because electromagnetic interference is unlikely to occur. The authors present two cases in which inappropriate antitachycardia therapy occurred intraoperatively with use of an underbody dispersive electrode, even though both surgeries were infraumbilical. The authors also present two cadaver models to demonstrate how monopolar electrosurgery below the umbilicus is sensed using both traditional and underbody dispersive electrosurgical return electrodes.


Assuntos
Desfibriladores Implantáveis , Desfibriladores Implantáveis/efeitos adversos , Eletrocirurgia , Humanos
3.
J Cardiovasc Electrophysiol ; 29(1): 17-21, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28877379

RESUMO

INTRODUCTION: Left atrial appendage (LAA) closure with the WATCHMAN device, according to FDA labelling, is recommended in patients with a maximal LAA ostial width between 17 and 31 mm. The safety and efficacy of LAA closure in patients with a maximal LAA ostial width < 17 mm has not been evaluated. The goal of this study was to determine the acute and short-term safety and efficacy of LAA closure with the WATCHMAN device in patients with a maximal LAA ostial width < 17 mm. METHODS AND RESULTS: Thirty-two consecutive patients with a maximal LAA ostial width < 17 mm as determined by a screening transesophageal echocardiogram (TEE) underwent LAA closure with the WATCHMAN device between March 2015 and November 2016 at five medical centers, and were included in this study. Mean age, body mass index (BMI), and CHA2 DS2 -VASC score were 70.8 ± 8.6 years, 29.3 ± 6.5 kg/m2 , and 3.9 ±1.2, respectively. At the screening TEE, mean maximal LAA ostial width and depth were 15.6 ± 0.6 mm (range 14-16) and 23.2 ± 4.5 mm (range 13-31), respectively. Successful LAA closure with the WATCHMAN device was achieved in 31 of 32 patients (97%), with no major complications. TEE performed 45 days after LAA closure demonstrated no peridevice leak > 5 mm and no device related thrombi. Warfarin was discontinued in all 31 patients 45 days after LAA closure. CONCLUSIONS: LAA closure with the WATCHMAN device can be successfully and safely achieved in patients with a maximal LAA ostial width < 17 mm.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Potenciais de Ação , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Bases de Dados Factuais , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Desenho de Equipamento , Frequência Cardíaca , Humanos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
Clin Genet ; 93(3): 567-576, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28708303

RESUMO

Although whole-exome sequencing (WES) is the gold standard for the diagnosis of neurodevelopmental disorders (NDDs), it remains expensive for some genetic centers. Commercialized panels comprising all OMIM-referenced genes called "medical exome" (ME) constitute an alternative strategy to WES, but its efficiency is poorly known. In this study, we report the experience of 2 clinical genetic centers using ME for diagnosis of NDDs. We recruited 216 consecutive index patients with NDDs in 2 French genetic centers, corresponded to the daily practice of the units and included non-syndromic intellectual disability (NSID, n = 33), syndromic ID (NSID = 122), pediatric neurodegenerative disorders (n = 7) and autism spectrum disorder (ASD, n = 54). We sequenced samples from probands and their parents (when available) with the Illumina TruSight One sequencing kit. We found pathogenic or likely pathogenic variants in 56 index patients, for a global diagnostic yield of 25.9%. The diagnosis yield was higher in patients with ID as the main diagnosis (32%) than in patients with ASD (3.7%). Our results suggest that the use of ME is a valuable strategy for patients with ID when WES cannot be used as a routine diagnosis tool.


Assuntos
Sequenciamento do Exoma , Estudos de Associação Genética , Predisposição Genética para Doença , Transtornos do Neurodesenvolvimento/genética , Adolescente , Adulto , Alelos , Criança , Pré-Escolar , Biologia Computacional/métodos , Feminino , Estudos de Associação Genética/métodos , Humanos , Lactente , Padrões de Herança , Masculino , Pessoa de Meia-Idade , Transtornos do Neurodesenvolvimento/diagnóstico , Fenótipo , Análise de Sequência de DNA/métodos , Adulto Jovem
5.
Ann Noninvasive Electrocardiol ; 23(2): e12467, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28660734

RESUMO

BACKGROUND: Although abnormalities of the QT interval are associated with atrial fibrillation (AF), it is unclear whether ventricular depolarization (QRS duration) or repolarization (JT interval) is a more important marker of AF risk. METHODS: This analysis included 4,181 (95% white; 59% women) participants from the Cardiovascular Health Study (CHS) who were free of baseline AF and major intraventricular delay. A linear scale was used to compute heart rate adjusted QT (QTa), QRS (QRSa ), and JT (JTa ) intervals. Prolonged QTa , QRSa , and JTa were defined by values greater than the sex-specific 95th percentile for each measurement. AF events were ascertained during the annual study electrocardiograms and from hospitalization discharge data. Cox regression was used to compute hazard ratios (HR) and 95% confidence intervals (CI) for the associations of prolonged QTa , QRSa , and JTa with AF, separately. RESULTS: Over a mean follow-up of 12.1 years, a total of 1,236 (30%) AF events were detected. An increased risk of AF (HR = 1.50. 95% CI = 1.20, 1.88) was observed with prolonged QTa . When we examined the association between individual components of the QTa interval and AF, the risk of AF was limited to prolonged JTa (HR = 1.31, 95% CI = 1.04, 1.65) and not prolonged QRSa (HR = 1.00, 95% CI = 0.77, 1.30). Similar results were obtained per 1-SD increase in QTa (HR = 1.07, 95% CI = 1.01, 1.13), QRSa (HR = 0.99, 95% CI = 0.94, 1.06), and JTa (HR = 1.07, 95% CI = 1.01, 1.13). CONCLUSIONS: The JT interval is a more important marker of AF risk in the QT interval among persons who do not have ventricular conduction delays.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/epidemiologia , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Estudos de Coortes , Intervalos de Confiança , Feminino , Humanos , Incidência , Masculino , Modelos de Riscos Proporcionais , Estudos Prospectivos , Medição de Risco , Taxa de Sobrevida
6.
Rev Neurol (Paris) ; 174(9): 581-588, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30166070

RESUMO

Neurotransmitter disorders comprise a rapidly expanding phenotypically and genetically heterogeneous group. Most of these disorders start in infancy through to childhood, although some forms may arise in adolescence and adulthood, and have various presentations. They may be overlooked if the phenotype leads to misdiagnoses involving various combinations of developmental disorders, hypotonia and movement disorders (dystonia, hyperkinesia, parkinsonism) or other clinical manifestations, such as sleep alterations and mood disorders. Neurotransmitter metabolite levels in cerebrospinal fluid (CSF) may help us to analyze and better understand the metabolic cascade and changes in dopamine and serotonin synthesis, and also guide genetic testing. Indeed, it is important to recognize these disorders in their early stages as they can be greatly improved by drug treatments, and if clinical responses are insufficient, then other agents that may enhance neurotransmission, such as serotonergic drugs and tetrahydrobiopterin (BH4) supplementation, could be considered. Also, a precise genetic diagnosis should be established by gene panels for dystonia, SNP microarrays and whole-exome sequencing. The present brief survey aims to review the present state of the art for the most commonly described and rare disorders of dopamine and serotonin, as well as cofactor deficiencies and dysfunctions, with an overview of clinical features, diagnostic strategies and treatments. Moreover, although these are mainly disorders of infants and children, many may nevertheless reach adulthood; thus, their evolution and treatments should be well known not only by pediatricians, but by neurologists as well, as the latter may be in charge at the stage of diagnosis (rarely) and during the follow-up of these rare patients.


Assuntos
Monoaminas Biogênicas , Transtornos dos Movimentos/fisiopatologia , Neurotransmissores , Adulto , Criança , Dopamina/metabolismo , Humanos , Transtornos dos Movimentos/diagnóstico , Serotonina/metabolismo
7.
Ann Noninvasive Electrocardiol ; 22(3): 1-5, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28019050

RESUMO

BACKGROUND: Although left ventricular hypertrophy (LVH) detected by electrocardiography (ECG-LVH) and echocardiography (echo-LVH) independently predict cardiovascular disease events, it is unclear if ECG-LVH and echo-LVH independently predict atrial fibrillation (AF). METHODS: This analysis included 4,904 participants (40% male; 85% white) from the Cardiovascular Health Study who were free of baseline AF and major intraventricular conduction delays. ECG-LVH was defined by Minnesota Code Classification from baseline ECG data. Echo-LVH was defined by sex-specific left ventricular mass values >95th sex-specific percentiles. Incident AF events were identified during the annual study ECGs and from hospitalization discharge data. Cox regression was used to compute hazard ratios (HR) and 95% confidence intervals (CI) for the association of ECG-LVH and echo-LVH with incident AF, separately. RESULTS: ECG-LVH was detected in 224 (4.6%) participants and echo-LVH was present in 231 (4.7%) participants. Over a median follow-up of 11.9 years, a total of 1,430 AF events were detected. In a multivariable Cox model adjusted for age, sex, race, education, income, smoking, systolic blood pressure, diabetes, body mass index, total cholesterol, high-density lipoprotein cholesterol, aspirin, antihypertensive medications, and cardiovascular disease, ECG-LVH (HR = 1.50; 95% CI = 1.18, 1.90) and echo-LVH (HR = 1.39; 95% CI = 1.09, 1.78) were independently associated with AF. When ECG-LVH (HR = 1.47, 95% CI = 1.16, 1.87) and echo-LVH (HR = 1.36, 1.07, 1.75) were included in the same model, both were predictive of incident AF. CONCLUSION: The association of ECG-LVH with AF is not dependent on left ventricular mass detected by echocardiography, suggesting that abnormalities in cardiac electrophysiology provide a distinct profile in the prediction of AF.


Assuntos
Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Eletrocardiografia/métodos , Hipertrofia Ventricular Esquerda/complicações , Hipertrofia Ventricular Esquerda/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Masculino , Tamanho do Órgão , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Risco
8.
J Cardiovasc Electrophysiol ; 27(4): 428-34, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26725742

RESUMO

INTRODUCTION: Totally thoracoscopic (TT) epicardial ablation combined with endocardial catheter ablation is an emerging treatment for persistent AF. The effects of timing of the TT and endocardial portion on AT/AF recurrence are not known. METHODS: We retrospectively analyzed patients undergoing TT staged versus simultaneous hybrid AF ablation at our institution. Arrhythmia-free outcome was compared using time to recurrence (AF or AT greater than 30 seconds after a 3-month blanking period from endocardial ablation) at 12 months. All subjects had continuous ILR or PM monitoring. RESULTS: Eighty-three patients (52 same-day, 31 staged) underwent TT hybrid AF ablation. Recurrence was observed in 23 (29%) patients at a median time of 147 days (IQR 91,238). In univariate analysis, a staged approach significantly increased the likelihood of detecting incomplete PVI (OR 6 [95% CI 2-17] P = 0.001). However, only longstanding persistent AF (LSP-AF) status predicted recurrence (HR 4 [95% CI 1.4-12] P = 0.01). Neither a staged approach (HR 1.0 [95% CI 0.4-2.4] P = 0.9), nor detection of incomplete PVI (HR 0.9 [95% CI 0.4-2.3] P = 0.8) predicted time to first AF/AT recurrence. CONCLUSIONS: Staged hybrid ablation of AF significantly increases the likelihood of discovering incomplete PVI at the time of endocardial mapping versus a same-day procedure. However, the staged approach did not improve time to first AT/AF recurrence.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ablação por Cateter/estatística & dados numéricos , Toracoscopia/métodos , Toracoscopia/estatística & dados numéricos , Idoso , Fibrilação Atrial/diagnóstico , Doença Crônica , Terapia Combinada/métodos , Terapia Combinada/estatística & dados numéricos , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Recidiva , Reoperação/métodos , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Tennessee/epidemiologia , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 26(10): 1111-6, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26222980

RESUMO

INTRODUCTION: Cardiac implantable electronic device (CIED) infections are potentially preventable complications associated with high morbidity, mortality, and cost. A recently developed bio-absorbable antibacterial envelope (TYRX™-A) might prevent CIED infections in high-risk subjects. However, data regarding safety and efficacy have not been published. METHODS AND RESULTS: In a single-center retrospective cohort study, we compared the prevalence of CIED infections among subjects with ≥2 risk factors treated with the TYRX™-A envelope (N = 135), the nonabsorbable TYRX™ envelope (N = 353), and controls who did not receive an envelope (N = 636). Infection was ascertained by individual chart review. The mean (95% confidence interval) number of risk factors was 3.08 (2.84-3.32) for TYRX™-A, 3.20 (3.07-3.34) for TYRX™, and 3.09 (2.99-3.20) for controls, P = 0.3. After a minimum 300 days follow-up, the prevalence of CIED infection was 0 (0%) for TYRX™-A, 1 (0.3%) for TYRX™, and 20 (3.1%) for controls (P = 1 for TYRX™-A vs. TYRX™, P = 0.03 for TYRX™-A vs. controls, and P = 0.002 for TYRX™ vs. controls). In a propensity score-matched cohort of 316 recipients of either envelope and 316 controls, the prevalence of infection was 0 (0%) and 9 (2.8%), respectively, P = 0.004. When limited to 122 TYRX™-A recipients and 122 propensity-matched controls, the prevalence of CIED infections was 0 (0%) and 5 (4.1%), respectively, P = 0.024. CONCLUSIONS: Among high-risk subjects, the TYRX™-A bio-absorbable envelope was associated with a very low prevalence of CIED related infections that was comparable to that seen with the nonabsorbable envelope.


Assuntos
Antibacterianos/administração & dosagem , Desfibriladores Implantáveis/estatística & dados numéricos , Implantes de Medicamento/administração & dosagem , Marca-Passo Artificial/estatística & dados numéricos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Implantes Absorvíveis/estatística & dados numéricos , Idoso , Causalidade , Estudos de Coortes , Preparações de Ação Retardada/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Infecções Relacionadas à Prótese/diagnóstico , Estudos Retrospectivos , Fatores de Risco , Distribuição por Sexo , Taxa de Sobrevida , Tennessee/epidemiologia , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 25(1): 36-42, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24028661

RESUMO

INTRODUCTION: The FDA has issued class I advisories for Medtronic Sprint Fidelis(®) and St. Jude Medical Riata(TM) ICD lead families. Transvenous Riata(TM) ICD lead extraction is typically considered higher risk than Fidelis(®) extraction, based on longer duration from implant, presence of externalized conductors and lack of silicone backfill in the SVC and RV coils. However, published data comparing procedural outcomes between these leads are limited. METHODS: Records were reviewed for all patients undergoing transvenous extraction of Sprint Fidelis(®) or Riata(TM) ICD leads at the Vanderbilt Heart and Vascular Institute from July 2006 to April 2013 to ascertain indication for extraction, procedural details, complications, and 30-day mortality. RESULTS: There were significant differences between those undergoing extraction of a Sprint Fidelis(®) (n = 145) or Riata(TM) lead (n = 47). In the Riata(TM) group, device-related endocarditis was a more common indication for extraction, the mean duration of implant was longer, and larger excimer laser sheaths were required. Lead malfunction was a more common indication in the Fidelis(®) group. There were no statistically significant differences in median procedure duration, procedural success (97.9% vs 95.7%, P = 0.41), median length of hospital stay (1 day vs 1 day, P = 0.23), procedural complication rate (5.5% vs 10.6%, P = 0.23) or 30-day mortality (2.1% vs 2.1%, P = 0.98). Analyses excluding patients with device infection revealed similar results. CONCLUSION: Despite differences in baseline characteristics, this study indicates that Medtronic Sprint Fidelis(®) and St. Jude Riata(TM) ICD leads have similar procedural outcomes with transvenous lead extraction.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/mortalidade , Remoção de Dispositivo/métodos , Eletrodos Implantados/efeitos adversos , Desfibriladores Implantáveis/microbiologia , Eletrodos Implantados/microbiologia , Endocardite/diagnóstico , Endocardite/mortalidade , Endocardite/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade/tendências , Estudos Retrospectivos , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 25(6): 617-21, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24446764

RESUMO

INTRODUCTION: Transvenous pacemaker or implantable cardioverter defibrillator (ICD) lead extraction via mechanical or excimer laser sheath is typically safe and effective. Longer duration from implant, presence of large vegetations or thrombi, fractured leads, and prior failed extraction are risk factors predicting higher complication rates or incomplete or failed lead removal. Techniques developed for minimally invasive valve surgery were used in conjunction with laser extraction to refine a "hybrid" technique for lead extraction. We assessed the outcomes of high-risk lead extraction using this hybrid lead extraction technique. METHODS AND RESULTS: Retrospective assessment of clinical parameters and procedural outcomes in patients undergoing planned hybrid lead extraction from February 2008 to September 2012 was performed. We report 8 cases of hybrid lead extraction performed at our institution. We extracted 21 leads with average lead age of 13.8 years since implant. All leads were removed with complete clinical and radiographic success. There were no intraprocedure complications. One patient died of continued sepsis and 1 other had symptoms consistent with pulmonary embolism. CONCLUSIONS: Hybrid lead extraction using this technique is a safe and effective approach for removal of high-risk chronic pacemaker or ICD leads. This method extends the range of approachable leads resulting in complete removal without median sternotomy. Hybrid lead extraction can be scheduled electively facilitating complete lead removal with a low complication rate and short postoperative recovery time, mitigating the risks inherent in midline sternotomy or emergent cardiac surgical rescue.


Assuntos
Angioplastia a Laser/métodos , Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Falha de Equipamento , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Toracotomia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 24(9): 1047-50, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23577693

RESUMO

St. Jude Riata family ICD leads are subject to an FDA class I recall due to insulation failure, cable extrusions, and a high rate of electrical failures. We present multiple cases of large intravascular thrombus formation adherent to externalized conductor cables on Riata leads. Our observations highlight a previously unknown risk of large or calcified thrombus formation involving externalized conductors. We suggest that these leads should be screened for thrombi prior to potential lead extraction to determine the safest approach. Serial echocardiography may help detect progressive thrombus formation. The role of systemic anticoagulation for prevention or treatment of these thrombi remains unclear.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Falha de Equipamento , Cardiopatias/diagnóstico , Trombose/diagnóstico , Idoso , Feminino , Cardiopatias/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Trombose/etiologia
13.
J Med Case Rep ; 17(1): 523, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38124073

RESUMO

INTRODUCTION: Acute cardiac tamponade is a rare event during any type of interventional or surgical procedure. It can occur during electrophysiology procedures due to radiofrequency ablation, lead or catheter manipulation, transseptal puncture, laser lead extractions, or left atrial appendage occlusion device positioning. Cardiac tamponade is difficult to study in a prospective manner, and case reports and case series are important contributions to understanding the best options for patient care. An 87-year-old Caucasian male patient breathing spontaneously developed acute tamponade during an atrial flutter ablation. Pericardial drain insertion was difficult, and hypotension failed to respond to epinephrine boluses. The patient became hypoxemic and hypercarbic, requiring intubation. Unexpectedly, the blood pressure markedly increased postintubation and remained in a normal range until the pericardium was drained. CONCLUSION: Spontaneous ventilation is considered important to maintain venous return to the right heart during cardiac tamponade. However, spontaneous ventilation reduces venous return to the left heart and worsens the paradoxical pulse in tamponade. Intravenous vasopressors are thought to be ineffective during cardiac tamponade. Our patient maintained pulmonary blood flow as indicated by end-tidal carbon dioxide measurements but had no measurable systemic blood pressure during spontaneous ventilation. Our case demonstrates that tracheal intubation and positive pressure ventilation can transiently improve left heart venous return, systemic perfusion, and drug delivery to the systemic circulation.


Assuntos
Flutter Atrial , Tamponamento Cardíaco , Ablação por Cateter , Idoso de 80 Anos ou mais , Humanos , Masculino , Flutter Atrial/cirurgia , Flutter Atrial/complicações , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Hemodinâmica/fisiologia , Respiração com Pressão Positiva , Estudos Prospectivos
16.
J Interv Card Electrophysiol ; 63(3): 531-544, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34424446

RESUMO

BACKGROUND: The ideal treatment of inappropriate sinus tachycardia (IST) and postural orthostatic tachycardia syndrome (POTS) still needs to be defined. Medical treatments yield suboptimal results. Endocardial catheter ablation of the sinus node (SN) may risk phrenic nerve damage and open-heart surgery may be accompanied by unjustified invasive risks. METHODS: We describe our first multicenter experience of 255 consecutive patients (235 females, 25.94 ± 3.84 years) having undergone a novel SN sparing hybrid thoracoscopic ablation for drug-resistant IST (n = 204, 80%) or POTS (n = 51, 20%). As previously described, the SN was identified with 3D mapping. Surgery was performed through three 5-mm ports from the right side. A minimally invasive approach with a bipolar radiofrequency clamp was used to ablate targeted areas while sparing the SN region. The targeted areas included isolation of the superior and the inferior caval veins, and a crista terminalis line was made. All lines were interconnected. RESULTS: Normal sinus rhythm (SR) was restored in all patients at the end of the procedure. All patients discontinued medication during the follow-up. After a blanking period of 6 months, all patients presented stable SR. At a mean of 4.07 ± 1.8 years, normal SN reduction and chronotropic response to exercise were present. In the 51 patients initially diagnosed with POTS, no syncope occurred. During follow-up, pericarditis was the most common complication (121 patients: 47%), with complete resolution in all cases. Pneumothorax was observed in 5 patients (1.9%), only 3 (1.1%) required surgical drainage. Five patients (1.9%) required a dual-chamber pacemaker due to sinus arrest > 5 s. CONCLUSIONS: Preliminary results of this multicenter experience with a novel SN sparing hybrid ablation of IST/POTS, using surgical thoracoscopic video-assisted epicardial ablation combined with simultaneous endocardial 3D mapping may prove to be an efficient and safe therapeutic option in patients with symptomatic drug-resistant IST and POTS. Importantly, in our study, all patients had a complete resolution of the symptoms and restored normal SN activity.


Assuntos
Ablação por Cateter , Síndrome da Taquicardia Postural Ortostática , Ablação por Cateter/métodos , Endocárdio/cirurgia , Feminino , Humanos , Síndrome da Taquicardia Postural Ortostática/diagnóstico , Nó Sinoatrial/cirurgia , Taquicardia Sinusal/diagnóstico
17.
J Clin Cases Rep ; 4(2): 39-42, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33367223

RESUMO

Cardiac tumors are rare, with primary tumors much rarer than secondary. They can present with a variety of symptoms, including cardiogenic shock, arrhythmias, tamponade, and systemic embolism. There have been cases reported of patients having cardiac tumors presenting with ST elevations. While the exact pathophysiological mechanism for ST changes in patient with tumors is not known, proposed theories include tumor emboli to coronary artery, external compression of coronary arteries, stretching of cardiac muscle fibers, inflammatory reactions, and electrolyte transfer from necrotic tumor tissue to adjacent myocardium. We present a case in which the patient had no prior history of malignancy that are presented with cough, shortness of breath, lower extremity edema, ST elevation on electrocardiogram, and was found to have epithelioid tumor in his left ventricle. This case raises awareness of wide differential for ST changes on electrocardiogram besides myocardial infarction, especially in patients who do not present with classic ischemic symptoms.

18.
J Innov Card Rhythm Manag ; 12(4): 4477-4481, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33959407

RESUMO

A 39-year-old man presented with lifelong palpitations, a mildly reduced left ventricular ejection fraction, and incessant tachycardia. Electrocardiography revealed a regular, one-to-one supraventricular tachycardia with superiorly directed P-waves and a long R-P interval. The differential diagnosis of the tachycardia, response to invasive electrophysiologic maneuvers, and treatment with catheter ablation are discussed.

19.
J Innov Card Rhythm Manag ; 12(5): 4501-4505, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34035982

RESUMO

Ventricular tachycardia storm is associated with high mortality rates and is often refractory to treatment. Historically, few options for treatment have existed in cases when antiarrhythmic drugs fail. We report the case of a patient with incessant ventricular fibrillation (VF) in the postinfarction period that was triggered by premature ventricular contractions (PVCs) that persisted despite normal electrolytes, exclusion of ongoing ischemia, infusions of antiarrhythmic drugs, general anesthesia, full circulatory support with extracorporeal membranous oxygenation, and cardiac sympathetic denervation. Given that the VF appeared to be triggered consistently by a unifocal, short-coupled PVC (consistent with Purkinje fiber-mediated VF), we performed catheter ablation, after which point, the patient experienced no further PVCs or ventricular arrhythmia. This case serves as a reminder of three key teaching points. First, not all VF is created equal, with some cases being chiefly the result of a vulnerable substrate and others being best accounted for by frequent triggers. Second, examining the available electrocardiographic data and appropriately interpreting them can guide the selection of therapies up to and including catheter ablation for treatment-refractory VF. Third, full circulatory support greatly facilitates successful electroanatomic mapping and catheter ablation of unstable ventricular arrhythmias.

20.
Diabetes ; 69(10): 2186-2193, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32732305

RESUMO

Compared with standard glycemic control, intensive glycemic control caused increased mortality in the Action to Control Cardiovascular Risk in Diabetes (ACCORD) trial. Preliminary data from several studies suggest that intensive glycemic control is associated with QT prolongation, which may lead to ventricular arrhythmias as a possible explanation of this increased mortality. We sought to assess the effects of intensive glycemic control and intensive blood pressure control on the risk of incident QT prolongation. Cox proportional hazards models were used to compare the risk of incident QT prolongation (>460 ms in women or >450 ms in men) in the intensive versus standard glycemic control arms. Over a combined 48,634 person-years of follow-up (mean 4.9), 634 participants (6.4%) developed a prolonged QTc. Participants in the intensive glycemic control arm did not have an increased risk of QT prolongation. Similarly, a strategy of intensive blood pressure control did not result in a significant change in risk of prolonged QTc. Sensitivity analyses using alternative QT correction formulas (Hodges and Bazett) yielded overall similar findings. In conclusion, the increased mortality observed in the intensive glycemic control arm in the ACCORD trial is not likely to be explained by QT prolongation leading to lethal ventricular arrhythmias.


Assuntos
Arritmias Cardíacas/fisiopatologia , Síndrome do QT Longo/fisiopatologia , Arritmias Cardíacas/metabolismo , Glicemia/metabolismo , Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Humanos , Modelos de Riscos Proporcionais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA