Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 389(13): 1167-1179, 2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37622677

RESUMO

BACKGROUND: Device-detected atrial high-rate episodes (AHREs) are atrial arrhythmias detected by implanted cardiac devices. AHREs resemble atrial fibrillation but are rare and brief. Whether the occurrence of AHREs in patients without atrial fibrillation (as documented on a conventional electrocardiogram [ECG]) justifies the initiation of anticoagulants is not known. METHODS: We conducted an event-driven, double-blind, double-dummy, randomized trial involving patients 65 years of age or older who had AHREs lasting for at least 6 minutes and who had at least one additional risk factor for stroke. Patients were randomly assigned in a 1:1 ratio to receive edoxaban or placebo. The primary efficacy outcome was a composite of cardiovascular death, stroke, or systemic embolism, evaluated in a time-to-event analysis. The safety outcome was a composite of death from any cause or major bleeding. RESULTS: The analysis population consisted of 2536 patients (1270 in the edoxaban group and 1266 in the placebo group). The mean age was 78 years, 37.4% were women, and the median duration of AHREs was 2.8 hours. The trial was terminated early, at a median follow-up of 21 months, on the basis of safety concerns and the results of an independent, informal assessment of futility for the efficacy of edoxaban; at termination, the planned enrollment had been completed. A primary efficacy outcome event occurred in 83 patients (3.2% per patient-year) in the edoxaban group and in 101 patients (4.0% per patient-year) in the placebo group (hazard ratio, 0.81; 95% confidence interval [CI], 0.60 to 1.08; P = 0.15). The incidence of stroke was approximately 1% per patient-year in both groups. A safety outcome event occurred in 149 patients (5.9% per patient-year) in the edoxaban group and in 114 patients (4.5% per patient-year) in the placebo group (hazard ratio, 1.31; 95% CI, 1.02 to 1.67; P = 0.03). ECG-diagnosed atrial fibrillation developed in 462 of 2536 patients (18.2% total, 8.7% per patient-year). CONCLUSIONS: Among patients with AHREs detected by implantable devices, anticoagulation with edoxaban did not significantly reduce the incidence of a composite of cardiovascular death, stroke, or systemic embolism as compared with placebo, but it led to a higher incidence of a composite of death or major bleeding. The incidence of stroke was low in both groups. (Funded by the German Center for Cardiovascular Research and others; NOAH-AFNET 6 ClinicalTrials.gov number, NCT02618577; ISRCTN number, ISRCTN17309850.).


Assuntos
Anticoagulantes , Arritmias Cardíacas , Embolia , Inibidores do Fator Xa , Idoso , Feminino , Humanos , Masculino , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Embolia/tratamento farmacológico , Embolia/etiologia , Inibidores do Fator Xa/efeitos adversos , Inibidores do Fator Xa/uso terapêutico , Hemorragia/induzido quimicamente , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Eletrodos Implantados , Método Duplo-Cego , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Fatores de Risco
2.
Eur Heart J ; 45(10): 837-849, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-37956458

RESUMO

BACKGROUND AND AIMS: Patients with long atrial high-rate episodes (AHREs) ≥24 h and stroke risk factors are often treated with anticoagulation for stroke prevention. Anticoagulation has never been compared with no anticoagulation in these patients. METHODS: This secondary pre-specified analysis of the Non-vitamin K antagonist Oral anticoagulants in patients with Atrial High-rate episodes (NOAH-AFNET 6) trial examined interactions between AHRE duration at baseline and anticoagulation with edoxaban compared with placebo in patients with AHRE and stroke risk factors. The primary efficacy outcome was a composite of stroke, systemic embolism, or cardiovascular death. The safety outcome was a composite of major bleeding and death. Key secondary outcomes were components of these outcomes and electrocardiogram (ECG)-diagnosed atrial fibrillation. RESULTS: Median follow-up of 2389 patients with core lab-verified AHRE was 1.8 years. AHRE ≥24 h were present at baseline in 259/2389 patients (11%, 78 ± 7 years old, 28% women, CHA2DS2-VASc 4). Clinical characteristics were not different from patients with shorter AHRE. The primary outcome occurred in 9/132 patients with AHRE ≥24 h (4.3%/patient-year, 2 strokes) treated with anticoagulation and in 14/127 patients treated with placebo (6.9%/patient-year, 2 strokes). Atrial high-rate episode duration did not interact with the efficacy (P-interaction = .65) or safety (P-interaction = .98) of anticoagulation. Analyses including AHRE as a continuous parameter confirmed this. Patients with AHRE ≥24 h developed more ECG-diagnosed atrial fibrillation (17.0%/patient-year) than patients with shorter AHRE (8.2%/patient-year; P < .001). CONCLUSIONS: This hypothesis-generating analysis does not find an interaction between AHRE duration and anticoagulation therapy in patients with device-detected AHRE and stroke risk factors. Further research is needed to identify patients with long AHRE at high stroke risk.


Assuntos
Fibrilação Atrial , Piridinas , Acidente Vascular Cerebral , Tiazóis , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/diagnóstico , Átrios do Coração , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/diagnóstico , Anticoagulantes/uso terapêutico
3.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-39028767

RESUMO

Catheter ablation (CA) has become an established treatment strategy for managing recurrent ventricular tachycardias (VTs) in patients with structural heart disease. In recent years, percutaneous mechanical circulatory support (PMCS) devices have been increasingly used intra-operatively to improve the ablation outcome. One indication would be rescue therapy for patients who develop haemodynamic deterioration during the ablation. However, more efforts are focused on identifying subjects who are at high risk of such deterioration and could benefit from the pre-emptive use of the PMCS. The third reason to use PMCS could be the inability to identify diffuse substrate, especially in non-ischaemic cardiomyopathy. This paper reviews available experiences using various types of PMCS in different clinical scenarios. Although PMCS allows mapping during VT, it does not significantly influence acute outcomes and not convincingly long-term outcomes. On the contrary, the complication rate appears to be higher in PMCS cohorts. Our data suggest that even in patients with severe left ventricular dysfunction, the substrate modification can be performed without the need for general anaesthesia and risk of haemodynamic decompensation. In end-stage heart failure associated with the electrical storm, implantation of a left ventricular assist device (or PMCS with a transition to the left ventricular assist device) might be the preferred strategy before CA. In high-risk patients who are not potential candidates for these treatment options, radiotherapy could be considered as a bail-out treatment of recurrent VTs. These approaches should be studied in prospective trials.


Assuntos
Ablação por Cateter , Coração Auxiliar , Taquicardia Ventricular , Humanos , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Fatores de Risco , Hemodinâmica
4.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38988256

RESUMO

AIMS: A pulsed electric field (PF) energy source is a novel potential option for catheter ablation of ventricular arrhythmias (VAs) as it can create deeper lesions, particularly in scarred tissue. However, very limited data exist on its efficacy and safety. This prospective observational study reports the initial experience with VA ablation using focal PF. METHODS AND RESULTS: The study population consisted of 44 patients (16 women, aged 61 ± 14years) with either frequent ventricular premature complexes (VPCs, 48%) or scar-related ventricular tachycardia (VT, 52%). Ablation was performed using an irrigated 4 mm tip catheter and a commercially available PF generator. On average, 16 ± 15 PF applications (25 A) were delivered per patient. Acute success was achieved in 84% of patients as assessed by elimination of VPC or reaching non-inducibility of VT. In three cases (7%), a transient conduction system block was observed during PF applications remotely from the septum. Root analysis revealed that this event was caused by current leakage from the proximal shaft electrodes in contact with the basal interventricular septum. Acute elimination of VPC was achieved in 81% patients and non-inducibility of VT in 83% patients. At the 3-month follow-up, persistent suppression of the VPC was confirmed on Holter monitoring in 81% patients. In the VT group, the mean follow-up was 116 ± 75 days and a total of 52% patients remained free of any VA. CONCLUSION: Pulsed electric field catheter ablation of a broad spectrum of VA is feasible with acute high efficacy; however, the short-term follow-up is less satisfactory for patients with scar-related VT.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Resultado do Tratamento , Idoso , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/diagnóstico , Estudos Prospectivos , Cicatriz/etiologia , Técnicas Eletrofisiológicas Cardíacas
5.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38864730

RESUMO

AIMS: Patients with structural heart disease (SHD) undergoing catheter ablation (CA) for ventricular tachycardia (VT) are at considerable risk of periprocedural complications, including acute haemodynamic decompensation (AHD). The PAINESD score was proposed to predict the risk of AHD. The goal of this study was to validate the PAINESD score using the retrospective analysis of data from a large-volume heart centre. METHODS AND RESULTS: Patients who had their first radiofrequency CA for SHD-related VT between August 2006 and December 2020 were included in the study. Procedures were mainly performed under conscious sedation. Substrate mapping/ablation was performed primarily during spontaneous rhythm or right ventricular pacing. A purposely established institutional registry for complications of invasive procedures was used to collect all periprocedural complications that were subsequently adjudicated using the source medical records. Acute haemodynamic decompensation triggered by CA procedure was defined as intraprocedural or early post-procedural (<12 h) development of acute pulmonary oedema or refractory hypotension requiring urgent intervention. The study cohort consisted of 1124 patients (age, 63 ± 13 years; males, 87%; ischaemic cardiomyopathy, 67%; electrical storm, 25%; New York Heart Association Class, 2.0 ± 1.0; left ventricular ejection fraction, 34 ± 12%; diabetes mellitus, 31%; chronic obstructive pulmonary disease, 12%). Their PAINESD score was 11.4 ± 6.6 (median, 12; interquartile range, 6-17). Acute haemodynamic decompensation complicated the CA procedure in 13/1124 = 1.2% patients and was not predicted by PAINESD score with AHD rates of 0.3, 1.8, and 1.1% in subgroups by previously published PAINESD terciles (<9, 9-14, and >14). However, the PAINESD score strongly predicted mortality during the follow-up. CONCLUSION: Primarily substrate-based CA of SHD-related VT performed under conscious sedation is associated with a substantially lower rate of AHD than previously reported. The PAINESD score did not predict these events. The application of the PAINESD score to the selection of patients for pre-emptive mechanical circulatory support should be reconsidered.


Assuntos
Ablação por Cateter , Hemodinâmica , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Estudos Retrospectivos , Cicatriz/fisiopatologia , Idoso , Hipotensão/etiologia , Hipotensão/fisiopatologia , Hipotensão/diagnóstico , Edema Pulmonar/etiologia , Edema Pulmonar/diagnóstico , Edema Pulmonar/fisiopatologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/diagnóstico , Fatores de Risco
6.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38306687

RESUMO

AIMS: Data on the hybrid atrial fibrillation (AF) treatment are lacking in patients with structural heart disease undergoing concomitant CryoMaze procedures. The aim was to assess whether the timely pre-emptive catheter ablation would achieve higher freedom from AF or atrial tachycardia (AT) and be associated with better clinical outcomes than surgical ablation alone. METHODS AND RESULTS: The trial investigated patients with non-paroxysmal AF undergoing coronary artery bypass grafting and/or valve repair/replacement with mandatory concomitant CryoMaze procedure who were randomly assigned to undergo either radiofrequency catheter ablation [Hybrid Group (HG)] or no further treatment (Surgery Group). The primary efficacy endpoint was the first recurrence of AF/AT without class I or III antiarrhythmic drugs as assessed by implantable cardiac monitors. The primary clinical endpoint was a composite of hospitalization for arrhythmia recurrence, worsening of heart failure, cardioembolic event, or major bleeding. We analysed 113 and 116 patients in the Hybrid and Surgery Groups, respectively, with a median follow-up of 715 (IQR: 528-1072) days. The primary efficacy endpoint was significantly reduced in the HG [41.1% vs. 67.4%, hazard ratio (HR) = 0.38, 95% confidence interval (CI): 0.26-0.57, P < 0.001] as well as the primary clinical endpoint (19.9% vs. 40.1%, HR = 0.51, 95% CI: 0.29-0.86, P = 0.012). The trial groups did not differ in all-cause mortality (10.6% vs. 8.6%, HR = 1.17, 95%CI: 0.51-2.71, P = 0.71). The major complications of catheter ablation were infrequent (1.9%). CONCLUSION: Pre-emptively performed catheter ablation after the CryoMaze procedure was safe and associated with higher freedom from AF/AT and improved clinical outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Resultado do Tratamento , Taquicardia Supraventricular/cirurgia , Antiarrítmicos/uso terapêutico , Hemorragia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
7.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38646926

RESUMO

AIMS: Using thermal-based energy sources [radiofrequency (RF) energy/cryo energy] for catheter ablation is considered effective and safe when performing pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). However, treatment success remains limited and complications can occur due to the propagation of thermal energy into non-target tissues. We aim to compare pulsed field ablation (PFA) with RF ablation in terms of efficacy and safety for patients with drug-resistant paroxysmal AF. METHODS AND RESULTS: The BEAT PAROX-AF trial is a European multicentre, superiority, open-label randomized clinical trial in two parallel groups. A total of 292 participants were recruited in 9 high-volume European clinical centres in 5 countries. Patients with paroxysmal AF were randomized to PFA (FARAPULSE Endocardial Ablation System©, Boston Scientific) or RF using the CLOSE protocol with contact force sensing catheter (SmartTouch© catheter and CARTO© Biosense Webster). The primary endpoint will be the 1-year recurrence of atrial arrhythmia, and the major secondary safety endpoint will be the occurrence of acute (<7 days) procedure-related serious adverse events, or pulmonary vein stenosis, or atrio-oesophageal fistula up to 12 months. Additionally, five sub-studies investigate the effect of PFA on oesophageal safety, cerebral lesions, cardiac autonomic nervous system, durability of PVI as assessed during redo ablation procedures, and atrial and ventricular function. The study began on 27 December 2021 and concluded recruitment on 17 January 2024. Results will be available in mid-2025. CONCLUSION: The BEAT PAROX-AF trial aims to provide critical insights into the optimal treatment approach for patients with paroxysmal AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Feminino , Masculino , Recidiva , Europa (Continente) , Pessoa de Meia-Idade
8.
Europace ; 2023 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-37178136

RESUMO

AIMS: Atrial fibrillation (AF), typical atrial flutter (AFL), and other atrial tachycardias (ATs) are common in patients with pulmonary hypertension. Frequently, several supraventricular arrhythmias are successively observed in individual patients. We investigated the hypothesis of whether more extensive radiofrequency catheter ablation of the bi-atrial arrhythmogenic substrate instead of clinical arrhythmia ablation alone results in superior clinical outcomes in patients with pulmonary arterial hypertension (PH) and supraventricular arrhythmias. METHODS AND RESULTS: Patients with combined post- and pre-capillary or isolated pre-capillary PH and supraventricular arrhythmia indicated to catheter ablation were enrolled in three centres and randomized 1:1 into two parallel treatment arms. Patients underwent either clinical arrhythmia ablation only (Limited ablation group) or clinical arrhythmia plus substrate-based ablation (Extended ablation group). The primary endpoint was arrhythmia recurrence >30 s without antiarrhythmic drugs after the 3-month blanking period. A total of 77 patients (mean age 67 ± 10 years; 41 males) were enrolled. The presumable clinical arrhythmia was AF in 38 and AT in 36 patients, including typical AFL in 23 patients. During the median follow-up period of 13 (interquartile range: 12; 19) months, the primary endpoint occurred in 15 patients (42%) vs. 17 patients (45%) in the Extended vs. Limited ablation group (hazard ratio: 0.97, 95% confidence interval: 0.49-2.0). There was no excess of procedural complications and clinical follow-up events including an all-cause death in the Extended ablation group. CONCLUSION: Extensive ablation, compared with a limited approach, was not beneficial in terms of arrhythmia recurrence in patients with AF/AT and PH. CLINICAL TRIALS REGISTRATION: ClinicalTrials.gov; NCT04053361.

9.
Europace ; 25(7)2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37345804

RESUMO

Atrial high-rate episodes (AHRE) are atrial tachyarrhythmias detected by continuous rhythm monitoring by pacemakers, defibrillators, or implantable cardiac monitors. Atrial high-rate episodes occur in 10-30% of elderly patients without atrial fibrillation. However, it remains unclear whether the presence of these arrhythmias has therapeutic consequences. The presence of AHRE increases the risk of stroke compared with patients without AHRE. Oral anticoagulation would have the potential to reduce the risk of stroke in patients with AHRE but is also associated with a rate of major bleeding of ∼2%/year. The stroke rate in patients with AHRE appears to be lower than the stroke rate in patients with atrial fibrillation. Wearables like smart-watches will increase the absolute number of patients in whom atrial arrhythmias are detected. It remains unclear whether anticoagulation is effective and, equally important, safe in patients with AHRE. Two randomized clinical trials, NOAH-AFNET6 and ARTESiA, are expected to report soon. They will provide much-needed information on the efficacy and safety of oral anticoagulation in patients with AHRE.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fatores de Risco , Anticoagulantes/uso terapêutico , Átrios do Coração , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
10.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37695316

RESUMO

AIMS: Several studies have evaluated the use of electrically- or imaging-guided left ventricular (LV) lead placement in cardiac resynchronization therapy (CRT) recipients. We aimed to assess evidence for a guided strategy that targets LV lead position to the site of latest LV activation. METHODS AND RESULTS: A systematic review and meta-analysis was performed for randomized controlled trials (RCTs) until March 2023 that evaluated electrically- or imaging-guided LV lead positioning on clinical and echocardiographic outcomes. The primary endpoint was a composite of all-cause mortality and heart failure hospitalization, and secondary endpoints were quality of life, 6-min walk test (6MWT), QRS duration, LV end-systolic volume, and LV ejection fraction. We included eight RCTs that comprised 1323 patients. Six RCTs compared guided strategy (n = 638) to routine (n = 468), and two RCTs compared different guiding strategies head-to-head: electrically- (n = 111) vs. imaging-guided (n = 106). Compared to routine, a guided strategy did not significantly reduce the risk of the primary endpoint after 12-24 (RR 0.83, 95% CI 0.52-1.33) months. A guided strategy was associated with slight improvement in 6MWT distance after 6 months of follow-up of absolute 18 (95% CI 6-30) m between groups, but not in remaining secondary endpoints. None of the secondary endpoints differed between the guided strategies. CONCLUSION: In this study, a CRT implantation strategy that targets the latest LV activation did not improve survival or reduce heart failure hospitalizations.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Ecocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Hospitalização
11.
J Appl Biomed ; 21(2): 67-72, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37212155

RESUMO

BACKGROUND: Atrial fibrillation is common in patients with structural heart disease who are undergoing cardiac surgery. Surgical CryoMaze has been shown to be an effective treatment in several trials, but success rates have varied considerably, between 47-95%. The sequential hybrid approach, combining surgical CryoMaze followed by radiofrequency catheter ablation, can achieve high freedom from atrial arrhythmias. However, in patients with concomitant surgical atrial fibrillation treatment, data comparing the hybrid approach to CryoMaze alone are lacking. METHODS: The SurHyb study was designed as a prospective, open-label, multicentre randomized trial. Patients with non-paroxysmal atrial fibrillation who were scheduled for coronary artery bypass grafting or valve repair/replacement were randomized to either surgical CryoMaze alone or surgical CryoMaze followed by radiofrequency catheter ablation 3 months post-surgery. The primary outcome measure was arrhythmia-free survival without class I or III antiarrhythmic drugs, which has been evaluated using implantable cardiac monitors. CONCLUSIONS: This is the first randomized study that compares concomitant surgical CryoMaze alone with the staged hybrid surgical CryoMaze followed by catheter ablation, in patients with non-paroxysmal atrial fibrillation using rigorous rhythm monitoring. The results may contribute to the optimization of the treatment in patients undergoing concomitant CryoMaze for atrial fibrillation.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Ablação por Cateter , Humanos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Procedimentos Cirúrgicos Cardíacos/métodos , Ablação por Cateter/métodos , Estudos Multicêntricos como Assunto , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 33(12): 2569-2577, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36069129

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is the most common sustained arrhythmia in humans. The onset of the arrhythmia can significantly impair cardiac function. This hemodynamic deterioration has been explained by several mechanisms such as the loss of atrial contraction, shortening of ventricular filling, or heart rhythm irregularity. This study sought to evaluate the relative hemodynamic contribution of each of these components during in vivo simulated human AF. METHODS: Twelve patients undergoing catheter ablation for paroxysmal AF were paced simultaneously from the proximal coronary sinus and the His bundle region according to prescribed sequences of irregular R-R intervals with the average rate of 90 and 130 bpm, which were extracted from the database of digital ECG recordings of AF from other patients. The simulated AF was compared to regular atrial pacing with spontaneous atrioventricular conduction and regular simultaneous atrioventricular pacing at the same heart rate. Beat-by-beat left atrial and left ventricular pressures, including LV dP/dT and Tau index were assessed by direct invasive measurement; beat-by-beat stroke volume and cardiac output (index) were assessed by simultaneous pulse-wave doppler intracardiac echocardiography. RESULTS: Simulated AF led to significant impairment of left ventricular systolic and diastolic function. Both loss of atrial contraction and heart rate irregularity significantly contributed to hemodynamic impairment. This effect was pronounced with increasing heart rate. CONCLUSION: Our findings strengthen the rationale for therapeutic strategies aiming at rhythm control and heart rate regularization in patients with AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Função Ventricular Esquerda , Ablação por Cateter/efeitos adversos , Hemodinâmica , Frequência Cardíaca , Estimulação Cardíaca Artificial
13.
J Cardiovasc Electrophysiol ; 32(3): 647-656, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33428307

RESUMO

AIMS: Catheter ablation (CA) for atrial fibrillation (AF) has a considerable risk of procedural complications. Major vascular complications (MVCs) appear to be the most frequent. This study investigated gender differences in MVCs in patients undergoing CA for AF in a high-volume tertiary center. METHODS: A total of 4734 CAs for AF (65% paroxysmal, 26% repeated procedures) were performed at our center between January 2006 and August 2018. Patients (71% males) aged 60 ± 10 years and had a body mass index of 29 ± 4 kg/m2 at the time of the procedure. Radiofrequency point-by-point ablation was employed in 96.3% of procedures with the use of three-dimensional navigation systems and facilitated by intracardiac echocardiography. Pulmonary vein isolation was mandatory; cavotricuspid isthmus and left atrial substrate ablation were performed in 22% and 38% procedures, respectively. MVCs were defined as those that resulted in permanent injury, required intervention, or prolonged hospitalization. Their rates and risk factors were compared between genders. RESULTS: A total of 112 (2.4%) MVCs were detected: 54/1512 (3.5%) in females and 58/3222 (1.8%) in males (p < .0001). On multivariate analysis, lower body height was the only risk factor for MVCs in females (p = .0005). On the contrary, advanced age was associated with MVCs in males (p = .006). CONCLUSION: Females have a higher risk of MVCs following CA for AF compared to males. This difference is driven by lower body size in females. Low body height in females and advanced age in males are independent predictors of MVCs. Ultrasound-guided venipuncture lowered the MVC rate in males.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Fatores Sexuais , Resultado do Tratamento
14.
Europace ; 23(4): 610-615, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33185243

RESUMO

AIMS: Catheter ablation of ventricular tachycardia (VT) is an effective treatment in patients with structural heart disease (SHD) and recurrent arrhythmias. However, the procedure is associated with the risk of complications, including both manifest and asymptomatic cerebral thromboembolic events. We hypothesized that periprocedural asymptomatic brain injury (ABI) can be reduced by using transseptal instead of the retrograde access route to the left ventricle (LV). METHODS AND RESULTS: Consecutive patients undergoing VT ablation for SHD were randomized 1:1 to either retrograde or transseptal LV access. All patients underwent radiofrequency ablation in conscious sedation with the use of an irrigated tip catheter. The degree of brain damage was evaluated by serum level of biomarker S100B. Significant ABI was defined as a post-ablation relative increase of S100B level >30%. A total of 144 patients (66 ± 9 years; 14 females; 90% coronary artery disease; LV ejection fraction: 30 ± 8%) were enrolled and 72 were allocated to each study groups. Symptomatic neurological complication of the procedure was not observed in any subject. A significant ABI was detected in 19.4% of patients. It was more commonly observed in subjects randomized to retrograde vs. transseptal LV access (26.4% vs. 12.5%, P = 0.04). In a multivariate analysis, only retrograde LV access and advanced age were independent determinants of significant ABI. CONCLUSION: Significant ABI after ablation of VT in patients with SHD can be detected in one-fifth of subjects. Retrograde access to LV is associated with a two-fold higher probability of significant ABI.


Assuntos
Lesões Encefálicas , Ablação por Cateter , Cardiopatias , Taquicardia Ventricular , Idoso , Ablação por Cateter/efeitos adversos , Feminino , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
15.
Circulation ; 139(20): 2315-2325, 2019 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-30929474

RESUMO

BACKGROUND: Ventricular fibrillation (VF) storm after myocardial infarction (MI) is a life-threatening condition that necessitates multiple defibrillations. Catheter ablation is a potentially effective treatment strategy for VF storm refractory to optimal medical treatment. However, its impact on patient survival has not been verified in a large population. METHODS: We conducted a multicenter, retrospective observational study involving consecutive patients who underwent catheter ablation of post-MI refractory VF storm without preceding monomorphic ventricular tachycardia. The target of ablation was the Purkinje-related ventricular extrasystoles triggering VF. The primary outcome was in-hospital and long-term mortalities. Univariate logistic regression and Cox proportional-hazards analysis were used to evaluate clinical characteristics associated with in-hospital and long-term mortalities, respectively. RESULTS: One hundred ten patients were enrolled (age, 65±11years; 92 men; left ventricular ejection fraction, 31±10%). VF storm occurred at the acute phase of MI (4.5±2.5 days after the onset of MI during the index hospitalization for MI) in 43 patients (39%), the subacute phase (>1 week) in 48 (44%), and the remote phase (>6 months) in 19 (17%). The focal triggers were found to originate from the scar border zone in 88 patients (80%). During in-hospital stay after ablation, VF storm subsided in 92 patients (84%). Overall, 30 (27%) in-hospital deaths occurred. The duration from the VF occurrence to the ablation procedure was associated with in-hospital mortality (odds ratio for each 1-day increase, 1.11 [95% CI, 1.03-1.20]; P=0.008). During follow-up after discharge from hospital, only 1 patient developed recurrent VF storm. However, 29 patients (36%) died, with a median survival time of 2.2 years (interquartile range, 1.2-5.5 years). Long-term mortality was associated with left ventricular ejection fraction <30% (hazard ratio, 2.54 [95% CI, 1.21-5.32]; P=0.014), New York Heart Association class ≥III (hazard ratio, 2.68 [95% CI, 1.16-6.19]; P=0.021), a history of atrial fibrillation (hazard ratio, 3.89 [95% CI, 1.42-10.67]; P=0.008), and chronic kidney disease (hazard ratio, 2.74 [95% CI, 1.15-6.49]; P=0.023). CONCLUSIONS: In patients with MI presenting with focally triggered VF storm, catheter ablation of culprit triggers is lifesaving and appears to be associated with short- and long-term freedom from recurrent VF storm. Mortality over the long-term follow-up is associated with the severity of underlying cardiovascular disease and comorbidities in this specific patient population.


Assuntos
Ablação por Cateter/métodos , Infarto do Miocárdio/complicações , Fibrilação Ventricular/terapia , Idoso , Feminino , Seguimentos , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Ramos Subendocárdicos/fisiopatologia , Recidiva , Estudos Retrospectivos , Volume Sistólico , Análise de Sobrevida , Resultado do Tratamento , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/fisiopatologia , Complexos Ventriculares Prematuros/complicações , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/terapia
16.
Clin Transplant ; 34(2): e13773, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31859379

RESUMO

INTRODUCTION: Heart rate slowing agents are frequently prescribed to manage heart transplant (HTx) patients with the assumption that higher heart rate is a risk factor in cardiovascular disease. PATIENTS AND METHODS: This prospective two-center study investigated early progression of cardiac allograft vasculopathy (CAV) in 116 HTx patients. Examinations by coronary optical coherence tomography and 24-hour ambulatory ECG monitoring were performed both at baseline (1 month after HTx) and during follow-up (12 months after HTx). RESULTS: During the first post-HTx year, we observed a significant reduction in the mean coronary luminal area from 9.0 ± 2.5 to 8.0 ± 2.4 mm2 (P < .001), and progression in mean intimal thickness (IT) from 106.5 ± 40.4 to 130.1 ± 53.0 µm (P < .001). No significant relationship was observed between baseline and follow-up mean heart rates and IT progression (R = .02, P = .83; R = -.13, P = .18). We found a mild inverse association between beta-blocker dosage at 12 months and IT progression (R = -.20, P = .035). CONCLUSION: Our study did not confirm a direct association between mean heart rate and progression of CAV. The role of beta blockers warrants further investigation, with our results indicating that they may play a protective role in early CAV development.


Assuntos
Doença da Artéria Coronariana , Transplante de Coração , Aloenxertos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Frequência Cardíaca , Transplante de Coração/efeitos adversos , Humanos , Estudos Prospectivos , Tomografia de Coerência Óptica
18.
Europace ; 21(10): 1459-1467, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31377792

RESUMO

Self-terminating atrial arrhythmias are commonly detected on continuous rhythm monitoring, e.g. by pacemakers or defibrillators. It is unclear whether the presence of these arrhythmias has therapeutic consequences. We sought to summarize evidence on the prevalence of atrial high-rate episodes (AHREs) and their impact on risk of stroke. We performed a comprehensive, tabulated review of published literature on the prevalence of AHRE. In patients with AHRE, but without atrial fibrillation (AF), we reviewed the stroke risk and the potential risk/benefit of oral anticoagulation. Atrial high-rate episodes are found in 10-30% of AF-free patients. Presence of AHRE slightly increases stroke risk (0.8% to 1%/year) compared with patients without AHRE. Atrial high-rate episode of longer duration (e.g. those >24 h) could be associated with a higher stroke risk. Oral anticoagulation has the potential to reduce stroke risk in patients with AHRE but is associated with a rate of major bleeding of 2%/year. Oral anticoagulation is not effective in patients with heart failure or survivors of a stroke without AF. It remains unclear whether anticoagulation is effective and safe in patients with AHRE. Atrial high-rate episodes are common and confer a slight increase in stroke risk. There is true equipoise on the best way to reduce stroke risk in patients with AHRE. Two ongoing trials (NOAH-AFNET 6 and ARTESiA) will provide much-needed information on the effectiveness and safety of oral anticoagulation using non-vitamin K antagonist oral anticoagulants in patients with AHRE.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/epidemiologia , Átrios do Coração/fisiopatologia , Frequência Cardíaca/fisiologia , Medição de Risco/métodos , Acidente Vascular Cerebral/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Saúde Global , Humanos , Prevalência , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
19.
J Cardiovasc Electrophysiol ; 29(1): 64-70, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28884872

RESUMO

INTRODUCTION: Frequent ventricular premature complexes (VPCs) may cause symptoms and/or lead to deterioration of LV systolic function. Although frequent VPCs may be abolished by catheter ablation, it may be challenging in case of their origin from the LV papillary muscles (PMs). Our collaborative study aimed to analyze in detail the site of origin and the outcome of ablation. METHODS: Consecutive 34 patients (males: 68%; aged 62 ± 12 years; LV ejection fraction: 50 ± 9%) undergoing catheter ablation of VPCs originating from PMs were included. All procedures were guided by intracardiac echocardiography. RESULTS: The size and shape of PMs were highly variable. The length of anterolateral and posteromedial PM was 23 ± 4 mm and 28 ± 7 mm, respectively. In about one-third of patients, the PM was formed by two distinctly separate heads. The ectopic foci were located on anterolateral, posteromedial or both PM in 35%, 56% and 9% of cases, respectively. Their location was found within the distal, mid, or proximal (basal) third of PM in the 67%, 19%, and 14%, respectively. A total of 86% of PM foci were acutely abolished and long-term success was achieved in 65% of patients. Absence of VPCs of other morphologies and a high burden of ectopic activity before ablation were associated with favorable clinical outcome. CONCLUSION: VPCs originate predominantly from the distal portion of the PM. This knowledge may facilitate the mapping in patients with infrequent ectopic beats. Intracardiac echocardiography is of crucial importance for navigation of the ablation catheter and for assessment of its stability at PM target sites.


Assuntos
Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Músculos Papilares/fisiopatologia , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/fisiopatologia , Potenciais de Ação , Idoso , Ablação por Cateter , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Europa (Continente) , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/cirurgia , Fatores de Tempo , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA