Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Cerebellum ; 12(2): 205-11, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22987337

RESUMO

The objectives of this paper are (a) to establish the reliability of relative metabolite concentrations determined with (1)H-MR spectroscopy of the cerebellum using a method appropriate to the constraints of clinical radiology and (b) to record normal values for metabolites within the cerebellum and to look for differences in metabolite concentrations between the cerebellar hemispheric white matter and the superior vermis. 3-T (1)H-MR spectra were obtained from voxels positioned in the right cerebellar hemispheric white matter and the superior vermis in 55 healthy adults (mean age 41 years, range 20 to 77) using a single voxel PRESS sequence (TR/TE = 2,000/144 ms). One volunteer (male, age 34 years) was examined in six separate sessions over a period of 3 weeks. Reliability of intra- and inter-subject metabolite fitted area ratios was determined by evaluating coefficients of variance (%). Inter- and intra-subject coefficients of variance (%) in metabolite ratios were consistently lower in the vermis (4 to 11.6) compared to those of the hemisphere (7.2 to 14.3). Cho/Cr was significantly higher in the vermis (0.83 ± 0.10) compared to the hemisphere (0.76 ± 0.11) and NAA/Cho was significantly lower in the vermis (1.19 ± 0.12) compared to the hemisphere (1.35 ± 0.16). Low inter- and intra-subject variability can be achieved when using a (1)H-MR spectroscopy technique that is appropriate to the time constraints of clinical radiology. The regional variations of Cho/Cr and NAA/Cho within the hemisphere and vermis should be considered when performing studies of diseases, which may preferentially target a particular cerebellar location.


Assuntos
Cerebelo/anatomia & histologia , Cerebelo/metabolismo , Espectroscopia de Ressonância Magnética , Adulto , Idoso , Ácido Aspártico/metabolismo , Colina/metabolismo , Creatina/metabolismo , Feminino , Lateralidade Funcional , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Trítio/metabolismo , Adulto Jovem
2.
Diabetes ; 69(8): 1804-1814, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32471808

RESUMO

Painful diabetic peripheral neuropathy (DPN) is difficult to manage, as treatment response is often varied. The primary aim of this study was to examine differences in pain phenotypes between responders and nonresponders to intravenous lidocaine treatment using quantitative sensory testing. The secondary aim was to explore differences in brain structure and functional connectivity with treatment response. Forty-five consecutive patients who received intravenous lidocaine treatment for painful DPN were screened. Twenty-nine patients who met the eligibility criteria (responders, n = 14, and nonresponders, n = 15) and 26 healthy control subjects underwent detailed sensory profiling. Subjects also underwent multimodal brain MRI. A greater proportion of patients with the irritable (IR) nociceptor phenotype were responders to intravenous lidocaine treatment compared with nonresponders. The odds ratio of responding to intravenous lidocaine was 8.67 times greater (95% CI 1.4-53.8) for the IR nociceptor phenotype. Responders to intravenous lidocaine also had significantly greater mean primary somatosensory cortex cortical volume and functional connectivity between the insula cortex and the corticolimbic circuitry. This study provides preliminary evidence for a mechanism-based approach for individualizing therapy in patients with painful DPN.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Neuropatias Diabéticas/diagnóstico por imagem , Neuropatias Diabéticas/tratamento farmacológico , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Encéfalo/efeitos dos fármacos , Estudos de Coortes , Feminino , Humanos , Lidocaína/uso terapêutico , Masculino , Pessoa de Meia-Idade , Estudos Observacionais como Assunto , Fenótipo , Inquéritos e Questionários , Adulto Jovem
3.
Iran J Radiol ; 12(4): e18286, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26793288

RESUMO

BACKGROUND: Understanding hemodynamic environment in vessels is important for realizing the mechanisms leading to vascular pathologies. OBJECTIVES: Three-dimensional velocity vector field in carotid bifurcation is visualized using TR 3D phase-contrast magnetic resonance imaging (TR 3D PC MRI) and computational fluid dynamics (CFD). This study aimed to present a qualitative and quantitative comparison of the velocity vector field obtained by each technique. SUBJECTS AND METHODS: MR imaging was performed on a 30-year old male normal subject. TR 3D PC MRI was performed on a 3 T scanner to measure velocity in carotid bifurcation. 3D anatomical model for CFD was created using images obtained from time-of-flight MR angiography. Velocity vector field in carotid bifurcation was predicted using CFD and PC MRI techniques. A statistical analysis was performed to assess the agreement between the two methods. RESULTS: Although the main flow patterns were the same for the both techniques, CFD showed a greater resolution in mapping the secondary and circulating flows. Overall root mean square (RMS) errors for all the corresponding data points in PC MRI and CFD were 14.27% in peak systole and 12.91% in end diastole relative to maximum velocity measured at each cardiac phase. Bland-Altman plots showed a very good agreement between the two techniques. However, this study was not aimed to validate any of methods, instead, the consistency was assessed to accentuate the similarities and differences between Time-resolved PC MRI and CFD. CONCLUSION: Both techniques provided quantitatively consistent results of in vivo velocity vector fields in right internal carotid artery (RCA). PC MRI represented a good estimation of main flow patterns inside the vasculature, which seems to be acceptable for clinical use. However, limitations of each technique should be considered while interpreting results.

4.
Neurosurgery ; 61(1 Suppl): 187-96; discussion 196-7, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18813170

RESUMO

OBJECTIVE: To investigate the potential of novel magnetic resonance (MR) angiographic techniques for the assessment of cerebral arteriovenous malformations. METHODS: Forty patients who were about to undergo stereotactic radiosurgery were prospectively recruited. Three-dimensional, sliding-slab interleaved ky (SLINKY), time-of-flight acquisition was performed, as was a dynamic MR digital subtraction angiography (DSA) procedure in which single thick slices (6-10 cm) were obtained using a radiofrequency spoiled Fourier-acquired steady-state sequence (1 image/s). Sixty images were acquired, in two or three projections, during passage of a 6- to 10-ml bolus of gadolinium chelate. Subtraction and postprocessing were performed, and images were viewed in an inverted cine mode. SLINKY time-of-flight acquisition was repeated after the administration of gadolinium. Routine stereotactic conventional catheter angiography was performed after MR imaging. All images were assessed (in a blinded randomized manner) for Spetzler-Martin grading and determination of associated vascular pathological features. RESULTS: Forty-one arteriovenous malformations were assessed in 40 patients. Contrast-enhanced (CE) SLINKY MR angiography was the most consistent MR imaging technique, yielding a 95% correlation with the Spetzler-Martin classification defined by conventional catheter angiography; MR DSA exhibited 90% agreement, and SLINKY MR angiography exhibited 81% agreement. CE SLINKY MR angiography provided improved nidus delineation, compared with non-CE SLINKY MR angiography. Dynamic information from MR DSA significantly improved the observation of early-draining veins and associated aneurysms. CONCLUSION: CE SLINKY MR angiographic assessment of cerebral arteriovenous malformations offers significant advantages, compared with the use of non-CE SLINKY MR angiography, including improved nidus demonstration. MR DSA shows promise as a noninvasive method for dynamic angiography but is presently restricted by limitations in both temporal and spatial resolution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA