Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 210(4): 766-774, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29470153

RESUMO

OBJECTIVE: The purpose of this study is to evaluate whether use of a standardized radiology report template would improve the ability of liver transplant surgeons to diagnose stage T2 hepatocellular carcinoma (HCC) and determine patient suitability to undergo orthotopic liver transplant (OLT). MATERIALS AND METHODS: In this retrospective study, a standardized template was devised, and its use was mandated for reporting of liver CT findings for patients with cirrhosis and HCC. Two surgeons analyzed 200 reports (100 before and 100 after template implementation) for descriptions of cirrhosis, portal hypertension, lesion enhancement characteristics, tumor thrombus, portal and superior mesenteric vein patency, and Organ Procurement Transplantation Network (OPTN) class. Ability to determine Milan criteria and surgeon satisfaction were also assessed. Data obtained before and after template implementation were statistically analyzed using the Cochran-Mantel-Haenszel test. RESULTS: Template implementation increased the percentage of reports documenting the presence or absence of portal hypertension (74% to 88% for surgeon 1 and 86% to 87% for surgeon 2; p = 0.042); lesion number (76% to 88% for surgeon 2 [no change for surgeon 1]; p = 0.038), size (95% to 96% for surgeon 1 and 82% to 93% for surgeon 2; p = 0.03), and enhancement (93% to 94% for surgeon 1 and 80% to 91% for surgeon 2; p = 0.049); presence of tumor thrombus (10% to 57% for surgeon 1 and 31% to 63% for surgeon 2; p < 0.001); and OPTN class (8% to 82% for surgeon 1 and 2% to 81% for surgeon 2; p < 0.001). The surgeons were significantly more able to determine the presence of T2 disease and qualification for exception points after implementation of the template (increasing from 80% to 94%; p = 0.025). Satisfaction with reports also improved (p < 0.0001). CONCLUSION: The reporting template improved determination of patient suitability to undergo transplant according to the Milan criteria.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Transplante de Fígado , Seleção de Pacientes , Sistemas de Informação em Radiologia/normas , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/patologia , Feminino , Humanos , Cirrose Hepática/patologia , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Retrospectivos , Obtenção de Tecidos e Órgãos/normas
2.
Z Gastroenterol ; 56(5): 499-506, 2018 05.
Artigo em Alemão | MEDLINE | ID: mdl-29734449

RESUMO

The American College of Radiology (ACR) endorsed the Liver Imaging Reporting and Data System (LI-RADS) for standardized reporting and data collection of computed tomography (CT) and magnetic resonance (MR) imaging for hepatocellular carcinoma (HCC) in high-risk patients (liver cirrhosis). The LI-RADS imaging criteria are used to classify 'observations' from 'definitely benign' (LR-1) to 'definitely HCC' (LR-5) based on imaging criteria.Coincidently, the recent approval in the United States of a microbubble contrast agent for liver imaging (Lumason®, known as SonoVue® in Europe and elsewhere), LI-RADS. is being expanded to include contrast-enhanced ultrasound (CEUS). An international working group was initiated in 2014. Herewith, the most current version of CEUS-LI-RADS is presented.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia Doppler em Cores/métodos , Sistemas de Dados , Europa (Continente) , Humanos , Valor Preditivo dos Testes , Estados Unidos
3.
Radiology ; 281(3): 816-825, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27438167

RESUMO

Purpose To test the hypothesis that patients with pancreatic adenocarcinoma who otherwise are viewed to have resectable disease but have preoperative findings of extrapancreatic perineural invasion (EPNI) and/or duodenal invasion at multidetector computed tomography (CT) have reduced postoperative survival after pancreaticoduodenectomy for pancreatic ductal adenocarcinoma (PDAC). Materials and Methods This study was approved by the institutional review board and complied with HIPAA. The authors retrospectively evaluated 76 consecutive patients with PDAC who underwent preoperative multidetector CT and subsequent pancreaticoduodenectomy. Two radiologists blinded to surgical pathology results and clinical outcome evaluated multidetector CT images for evidence of EPNI and duodenal invasion; discrepancies were resolved by consensus. Also determined for each patient were resected lymph node status, tumor size, surgical margin status, time to progression, and time to death. Data were assessed with the Goodman-Kruskal gamma for correlations among indicators and the log-rank test, Kaplan-Meier estimates, and multivariate Cox proportional hazards regression for survival analysis. Results In univariate analysis, duodenal invasion and/or EPNI on preoperativemultidetector CT images was associated with significantly decreased progression-free survival (P < .0001) and overall survival (P = .0013), and the clinical indicators (lymph node status, tumor size, and surgical margin status) as well as duodenal invasion and/or EPNI showed correlation with each other. In multivariate regression that included multidetector CT findings as well as the three traditional clinical indicators, only duodenal invasion and/or EPNI showed significant independent association with reduction in both modes of survival (P < .0001 and P = .014, respectively). Interobserver agreement was substantial with respect to EPNI and duodenal invasion (κ = 0.691 and 0.682, respectively). Conclusion Patients with evidence of EPNI and/or duodenal invasion on preoperative multidetector CT images have significantly reduced survival after pancreaticoduodenectomy for PDAC. © RSNA, 2016.


Assuntos
Carcinoma Ductal Pancreático/patologia , Neoplasias Duodenais/patologia , Neoplasias Pancreáticas/patologia , Pancreaticoduodenectomia/métodos , Neoplasias do Sistema Nervoso Periférico/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Ductal Pancreático/mortalidade , Carcinoma Ductal Pancreático/cirurgia , Intervalo Livre de Doença , Neoplasias Duodenais/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Tomografia Computadorizada Multidetectores/mortalidade , Invasividade Neoplásica , Neoplasias Pancreáticas/mortalidade , Neoplasias Pancreáticas/cirurgia , Pancreaticoduodenectomia/mortalidade , Neoplasias do Sistema Nervoso Periférico/mortalidade , Cuidados Pré-Operatórios/métodos
4.
AJR Am J Roentgenol ; 205(6): W578-84, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26587947

RESUMO

OBJECTIVE: The purpose of this study was to test the hypothesis that soft-tissue infiltration along the celiac plexus and delayed enhancement exceeding two-thirds of the tumor area on preoperative MDCT correlate with histologic evidence of perineural invasion in resected intrahepatic cholangiocarcinomas. MATERIALS AND METHODS: Two experienced abdominal radiologists retrospectively reviewed preoperative multiphasic MDCT scans of 20 patients who underwent resection of intrahepatic cholangiocarcinoma, identifying soft-tissue infiltration along the celiac plexus, delayed enhancement exceeding two-thirds of the tumor area, and maximum tumor diameter. Consensus findings were compared with intratumoral perineural invasion in resected intrahepatic cholangiocarcinomas using the Fisher exact test. RESULTS: Six patients had histologic intratumoral perineural invasion, five of whom had soft-tissue infiltration along the celiac plexus on preoperative MDCT, with corresponding 83.3% sensitivity and 92.9% specificity for perineural invasion and significant association between these MDCT and histologic findings (p = 0.002). No patients with histologic perineural invasion had enhancement exceeding two-thirds of the tumor area on MDCT; sensitivity was 0.0% for this finding. Tumor diameter on MDCT was not significantly associated with perineural invasion at histopathology (p = 0.530). CONCLUSION: Soft-tissue infiltration along the celiac plexus on MDCT is an indicator of perineural invasion in patients with intrahepatic cholangiocarcinoma. The data did not confirm an association between delayed enhancement exceeding two-thirds of the tumor area and perineural invasion. Because perineural invasion from intrahepatic cholangiocarcinoma is associated with a very poor prognosis and is generally a contraindication to surgery, the MDCT diagnosis of celiac plexus perineural invasion in patients with intrahepatic cholangiocarcinoma may have important implications for prognosis and treatment planning.


Assuntos
Neoplasias dos Ductos Biliares/diagnóstico por imagem , Plexo Celíaco/diagnóstico por imagem , Colangiocarcinoma/patologia , Invasividade Neoplásica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Neoplasias dos Ductos Biliares/patologia , Plexo Celíaco/patologia , Meios de Contraste , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica/patologia , Estudos Retrospectivos
5.
J Ultrasound Med ; 34(12): 2225-30, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26518279

RESUMO

OBJECTIVES: To identify and evaluate sonographic features suggestive of extracapsular extension in papillary thyroid cancer. METHODS: Three board-certified radiologists blinded to the final pathologic tumor stage reviewed sonograms of pathologically proven cases of papillary thyroid cancer for the presence of extracapsular extension. The radiologists evaluated the following features: capsular abutment, bulging of the normal thyroid contour, loss of the echogenic capsule, and vascularity extending beyond the capsule. RESULTS: A total of 129 cases of pathologically proven thyroid cancer were identified. Of these, 51 were excluded because of lack of preoperative sonography, and 16 were excluded because of pathologic findings showing anaplastic carcinoma, follicular carcinoma, or microcarcinoma (<10 mm). The final analysis group consisted of 62 patients with papillary thyroid carcinoma, 16 of whom had pathologically proven extracapsular extension. The presence of capsular abutment had 100% sensitivity for detection of extracapsular extension. Conversely, lack of capsular abutment had a 100% negative predictive value (NPV) for excluding extracapsular extension. Contour bulging had 88% sensitivity for detection of extracapsular extension and when absent had an 87% NPV. Loss of the echogenic capsule was the best predictor of the presence of extracapsular extension, with an odds ratio of 10.23 (P = .034). This sonographic finding had 75% sensitivity, 65% specificity, and an 88% NPV. Vascularity beyond the capsule had 89% specificity but sensitivity of only 25%. CONCLUSIONS: Sonographic features of capsular abutment, contour bulging, and loss of the echogenic thyroid capsule have excellent predictive value for excluding or detecting extracapsular extension and may help in biopsy selection, surgical planning, and treatment of patients with papillary thyroid cancer.


Assuntos
Carcinoma/diagnóstico por imagem , Carcinoma/patologia , Invasividade Neoplásica/diagnóstico por imagem , Invasividade Neoplásica/patologia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia , Ultrassonografia/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Papilar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Câncer Papilífero da Tireoide , Glândula Tireoide/diagnóstico por imagem
7.
Eur Radiol ; 21(5): 982-6, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-20963444

RESUMO

OBJECTIVE: To identify CT findings predictive of surgical management in non-emergency small bowel obstruction (SBO). METHODS: Contrast-enhanced abdominal CT of 129 patients with non-emergency SBO were evaluated for small bowel luminal diameter, wall thickness, presence of the small bowel faeces sign (intraluminal particulate matter in a dilated small bowel) and length, transition point, submucosal oedema, mesenteric stranding, ascites and degree of obstruction (low grade partial, high grade partial and complete obstruction). Medical records were reviewed for age, gender, management and history of abdominal surgery, abdominal malignancy, or SBO. Statistical analyses were performed with Stata Release 9.2. RESULTS: Degree of obstruction was the only predictor of need for surgery. Whereas 18.0% of patients with low-grade partial obstruction (n = 50) underwent surgery, 32.5% of patients with high-grade partial obstruction (n = 77) and 100% of patients with complete obstruction (n = 2) required surgery (P = 0.004). The small bowel faeces sign was inversely predictive of surgery (P = 0.018). CONCLUSION: In non-emergency SBO patients with contrast-enhanced CT imaging, grade of obstruction predicts surgery, while the small bowel faeces sign inversely predicts need for surgery.


Assuntos
Meios de Contraste/farmacologia , Obstrução Intestinal/diagnóstico , Intestino Delgado/patologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Diagnóstico por Imagem/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Obstrução Intestinal/diagnóstico por imagem , Obstrução Intestinal/cirurgia , Intestino Delgado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
8.
Mol Ther ; 17(10): 1703-11, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19654568

RESUMO

The use of regulated gene expression systems is important for successful gene therapy applications. In this study, ligand-induced structural change in the estrogen receptor (ER) was used to develop a novel ER intramolecular folding-based transcriptional activation system. The system was studied using ER-variants of different lengths, flanked on either side by the GAL4-DNA-binding domain and the VP16-transactivation domain (GAL4(DBD)-ER-VP16). The ER ligands of different types showed efficient ligand-regulated transactivation. We also characterized a bidirectional transactivation system based on the ER and demonstrated its utility in titrating both reporter and therapeutic gene expression. The ligand-regulated transactivation system developed by using a mutant form of the ER (G521T, lacking affinity for the endogenous ligand 17beta-estradiol, whereas maintaining affinity for other ligands) showed efficient activation by the ligand raloxifene in living mice without significant interference from the circulating endogenous ligand. The ligand-regulated transactivation system was used to test the therapeutic efficiency of the tumor suppressor protein p53 in HepG2 (p53(+/+)) and SKBr3 (p53(-/-)/mutant-p53(+/+)) cells in culture and tumor xenografts in living mice. The multifunctional capabilities of this system should be useful for gene therapy applications, to study ER biology, to evaluate gene regulation, ER ligand screening, and ER ligand biocharacterization in cells and living animals.


Assuntos
Receptores de Estrogênio/química , Receptores de Estrogênio/genética , Ativação Transcricional/genética , Transgenes/genética , Animais , Linhagem Celular , Linhagem Celular Tumoral , Feminino , Vetores Genéticos/química , Vetores Genéticos/genética , Humanos , Camundongos , Ligação Proteica , Dobramento de Proteína , Proteína Supressora de Tumor p53/genética
9.
ACS Comb Sci ; 21(3): 207-222, 2019 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-30620189

RESUMO

Yeast surface display is a proven tool for the selection and evolution of ligands with novel binding activity. Selections from yeast surface display libraries against transmembrane targets are generally carried out using recombinant soluble extracellular domains. Unfortunately, these molecules may not be good models of their true, membrane-bound form for a variety of reasons. Such selection campaigns often yield ligands that bind a recombinant target but not target-expressing cells or tissues. Advances in cell-based selections with yeast surface display may aid the frequency of evolving ligands that do bind true, membrane-bound antigens. This study aims to evaluate ligand selection strategies using both soluble target-driven and cellular selection techniques to determine which methods yield translatable ligands most efficiently and generate novel binders against CD276 (B7-H3) and Thy1, two promising tumor vasculature targets. Out of four ligand selection campaigns carried out using only soluble extracellular domains, only an affibody library sorted against CD276 yielded translatable binders. In contrast, fibronectin domains against CD276 and affibodies against CD276 were discovered in campaigns that either combined soluble target and cellular selection methods or used cellular selection methods alone. A high frequency of non target-specific ligands discovered from the use of cellular selection methods alone motivated the development of a depletion scheme using disadhered, antigen-negative mammalian cells as a blocking agent. Affinity maturation of CD276-binding affibodies by error-prone PCR and helix walking resulted in strong, specific cellular CD276 affinity ( Kd = 0.9 ± 0.6 nM). Collectively, these results motivate the use of cellular selections in tandem with recombinant selections and introduce promising affibody molecules specific to CD276 for further applications.


Assuntos
Antígenos B7/química , Biomarcadores Tumorais/química , Vasos Sanguíneos/metabolismo , Fibronectinas/química , Proteínas Recombinantes de Fusão/química , Leveduras/química , Biomarcadores Tumorais/genética , Linhagem Celular , Membrana Celular/metabolismo , Escherichia coli , Fibronectinas/genética , Humanos , Ligantes , Biblioteca de Peptídeos , Ligação Proteica , Conformação Proteica , Engenharia de Proteínas/métodos , Estabilidade Proteica , Proteínas Recombinantes de Fusão/genética , Relação Estrutura-Atividade , Leveduras/genética
10.
PLoS Med ; 5(8): e170, 2008 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-18715113

RESUMO

BACKGROUND: Increasing efforts and financial resources are being invested in early cancer detection research. Blood assays detecting tumor biomarkers promise noninvasive and financially reasonable screening for early cancer with high potential of positive impact on patients' survival and quality of life. For novel tumor biomarkers, the actual tumor detection limits are usually unknown and there have been no studies exploring the tumor burden detection limits of blood tumor biomarkers using mathematical models. Therefore, the purpose of this study was to develop a mathematical model relating blood biomarker levels to tumor burden. METHODS AND FINDINGS: Using a linear one-compartment model, the steady state between tumor biomarker secretion into and removal out of the intravascular space was calculated. Two conditions were assumed: (1) the compartment (plasma) is well-mixed and kinetically homogenous; (2) the tumor biomarker consists of a protein that is secreted by tumor cells into the extracellular fluid compartment, and a certain percentage of the secreted protein enters the intravascular space at a continuous rate. The model was applied to two pathophysiologic conditions: tumor biomarker is secreted (1) exclusively by the tumor cells or (2) by both tumor cells and healthy normal cells. To test the model, a sensitivity analysis was performed assuming variable conditions of the model parameters. The model parameters were primed on the basis of literature data for two established and well-studied tumor biomarkers (CA125 and prostate-specific antigen [PSA]). Assuming biomarker secretion by tumor cells only and 10% of the secreted tumor biomarker reaching the plasma, the calculated minimally detectable tumor sizes ranged between 0.11 mm(3) and 3,610.14 mm(3) for CA125 and between 0.21 mm(3) and 131.51 mm(3) for PSA. When biomarker secretion by healthy cells and tumor cells was assumed, the calculated tumor sizes leading to positive test results ranged between 116.7 mm(3) and 1.52 x 10(6) mm(3) for CA125 and between 27 mm(3) and 3.45 x 10(5) mm(3) for PSA. One of the limitations of the study is the absence of quantitative data available in the literature on the secreted tumor biomarker amount per cancer cell in intact whole body animal tumor models or in cancer patients. Additionally, the fraction of secreted tumor biomarkers actually reaching the plasma is unknown. Therefore, we used data from published cell culture experiments to estimate tumor cell biomarker secretion rates and assumed a wide range of secretion rates to account for their potential changes due to field effects of the tumor environment. CONCLUSIONS: This study introduced a linear one-compartment mathematical model that allows estimation of minimal detectable tumor sizes based on blood tumor biomarker assays. Assuming physiological data on CA125 and PSA from the literature, the model predicted detection limits of tumors that were in qualitative agreement with the actual clinical performance of both biomarkers. The model may be helpful in future estimation of minimal detectable tumor sizes for novel proteomic biomarker assays if sufficient physiologic data for the biomarker are available. The model may address the potential and limitations of tumor biomarkers, help prioritize biomarkers, and guide investments into early cancer detection research efforts.


Assuntos
Biomarcadores Tumorais/sangue , Biomarcadores Tumorais/metabolismo , Programas de Rastreamento , Modelos Biológicos , Neoplasias/diagnóstico , Neoplasias/patologia , Antígeno Ca-125/sangue , Contagem de Células , Humanos , Proteínas de Neoplasias/sangue , Proteínas de Neoplasias/metabolismo , Neoplasias/sangue , Antígeno Prostático Específico/sangue , Antígeno Prostático Específico/metabolismo , Proteômica
11.
IEEE Trans Med Imaging ; 37(1): 241-250, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29293430

RESUMO

Ultrasound molecular imaging (USMI) is accomplished by detecting microbubble (MB) contrast agents that have bound to specific biomarkers, and can be used for a variety of imaging applications, such as the early detection of cancer. USMI has been widely utilized in preclinical imaging in mice; however, USMI in humans can be challenging because of the low concentration of bound MBs and the signal degradation caused by the presence of heterogenous soft tissue between the transducer and the lesion. Short-lag spatial coherence (SLSC) beamforming has been proposed as a robust technique that is less affected by poor signal quality than standard delay-and-sum (DAS) beamforming. In this paper, USMI performance was assessed using contrast-enhanced ultrasound imaging combined with DAS (conventional CEUS) and with SLSC (SLSC-CEUS). Each method was characterized by flow channel phantom experiments. In a USMI-mimicking phantom, SLSC-CEUS was found to be more robust to high levels of additive thermal noise than DAS, with a 6dB SNR improvement when the thermal noise level was +6dB or higher. However, SLSC-CEUS was also found to be insensitive to increases in MB concentration, making it a poor choice for perfusion imaging. USMI performance was also measured in vivo using VEGFR2-targeted MBs in mice with subcutaneous human hepatocellular carcinoma tumors, with clinical imaging conditions mimicked using a porcine tissue layer between the tumor and the transducer. SLSC-CEUS improved the SNR in each of ten tumors by an average of 41%, corresponding to 3.0dB SNR. These results indicate that the SLSC beamformer is well-suited for USMI applications because of its high sensitivity and robust properties under challenging imaging conditions.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Modelos Biológicos , Imagem Molecular/métodos , Ultrassonografia/métodos , Animais , Artefatos , Xenoenxertos/química , Xenoenxertos/diagnóstico por imagem , Humanos , Camundongos , Neoplasias Experimentais/química , Neoplasias Experimentais/diagnóstico por imagem , Imagens de Fantasmas , Sensibilidade e Especificidade , Razão Sinal-Ruído , Suínos , Receptor 2 de Fatores de Crescimento do Endotélio Vascular/análise , Receptor 2 de Fatores de Crescimento do Endotélio Vascular/metabolismo
12.
Pancreas ; 47(6): 675-689, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29894417

RESUMO

Pancreatic ductal adenocarcinoma (PDAC) has a dismal prognosis. To improve outcomes, there is a critical need for improved tools for detection, accurate staging, and resectability assessment. This could improve patient stratification for the most optimal primary treatment modality. Molecular imaging, used in combination with tumor-specific imaging agents, can improve established imaging methods for PDAC. These novel, tumor-specific imaging agents developed to target specific biomarkers have the potential to specifically differentiate between malignant and benign diseases, such as pancreatitis. When these agents are coupled to various types of labels, this type of molecular imaging can provide integrated diagnostic, noninvasive imaging of PDAC as well as image-guided pancreatic surgery. This review provides a detailed overview of the current clinical imaging applications, upcoming molecular imaging strategies for PDAC, and potential targets for imaging, with an emphasis on intraoperative imaging applications.


Assuntos
Carcinoma Ductal Pancreático/diagnóstico por imagem , Imagem Molecular/métodos , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Carcinoma Ductal Pancreático/cirurgia , Diagnóstico Diferencial , Humanos , Monitorização Intraoperatória/métodos , Pâncreas/patologia , Pâncreas/cirurgia , Neoplasias Pancreáticas/cirurgia , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Abdom Radiol (NY) ; 43(1): 127-142, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28819825

RESUMO

Contrast-enhanced ultrasound (CEUS) is a specialized form of ultrasound (US) performed with an intravenous injection of microbubble contrast agents. It has been successfully used for a variety of applications including characterization of liver tumors. In April 2014, the American College of Radiology (ACR) convened a working group of international experts to develop ACR CEUS Liver Imaging Reporting and Data System (CEUS LI-RADS). An initial version of CEUS LI-RADS was published in August 2016. Although the CEUS LI-RADS concept and principles for liver lesion characterization, using dynamic contrast enhancement features, are similar to those for CT or MRI, there are significant differences between CT/MRI and CEUS LI-RADS. Therefore, CEUS LI-RADS has different diagnostic features and a unique characterization algorithm. The size of a lesion, the type and degree of arterial phase enhancement, the presence of washout, and the timing and degree of washout are the major features used for categorization. This paper describes key differences between CT/MRI and CEUS, and provides a diagnostic algorithm of CEUS LI-RADS with detailed, step-by-step instructions and imaging examples of CEUS LI-RADS categories.


Assuntos
Algoritmos , Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Neoplasias Hepáticas/diagnóstico por imagem , Ultrassonografia/métodos , Carcinoma Hepatocelular/patologia , Diagnóstico Diferencial , Humanos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
14.
Theranostics ; 8(18): 5126-5142, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30429890

RESUMO

In ultrasound molecular imaging (USMI), ligand-functionalized microbubbles (MBs) are used to visualize vascular endothelial targets. Netrin-1 is upregulated in 60% of metastatic breast cancers and promotes tumor progression. A novel netrin-1 interference therapy requires the assessment of netrin-1 expression prior to treatment. In this study, we studied netrin-1 as a target for USMI and its potential as a companion diagnostic in breast cancer models. Methods: To verify netrin-1 expression and localization, an in vivo immuno-localization approach was applied, in which anti-netrin-1 antibody was injected into living mice 24 h before tumor collection, and revealed with secondary fluorescent antibody for immunofluorescence analysis. Netrin-1 interactions with the cell surface were studied by flow cytometry. Netrin-1-targeted MBs were prepared using MicroMarker Target-Ready (VisualSonics), and validated in in vitro binding assays in static conditions or in a flow chamber using purified netrin-1 protein or netrin-1-expressing cancer cells. In vivo USMI of netrin-1 was validated in nude mice bearing human netrin-1-positive SKBR7 tumors or weakly netrin-1-expressing MDA-MB-231 tumors using the Vevo 2100 small animal imaging device (VisualSonics). USMI feasibility was further tested in transgenic murine FVB/N Tg(MMTV/PyMT634Mul) (MMTV-PyMT) mammary tumors. Results: Netrin-1 co-localized with endothelial CD31 in netrin-1-positive breast tumors. Netrin-1 binding to the surface of endothelial HUVEC and cancer cells was partially mediated by heparan sulfate proteoglycans. MBs targeted with humanized monoclonal anti-netrin-1 antibody bound to netrin-1-expressing cancer cells in static and dynamic conditions. USMI signal was significantly increased with anti-netrin-1 MBs in human SKBR7 breast tumors and transgenic murine MMTV-PyMT mammary tumors compared to signals recorded with either isotype control MBs or after blocking of netrin-1 with humanized monoclonal anti-netrin-1 antibody. In weakly netrin-1-expressing human tumors and normal mammary glands, no difference in imaging signal was observed with anti-netrin-1- and isotype control MBs. Ex vivo analysis confirmed netrin-1 expression in MMTV-PyMT tumors. Conclusions: These results show that USMI allowed reliable detection of netrin-1 on the endothelium of netrin-1-positive human and murine tumors. Significant differences in USMI signal for netrin-1 reflected the significant differences in netrin-1 mRNA & protein expression observed between different breast tumor models. The imaging approach was non-invasive and safe, and provided the netrin-1 expression status in near real-time. Thus, USMI of netrin-1 has the potential to become a companion diagnostic for the stratification of patients for netrin-1 interference therapy in future clinical trials.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/terapia , Imunoterapia/métodos , Imagem Molecular/métodos , Terapia de Alvo Molecular/métodos , Netrina-1/análise , Ultrassonografia/métodos , Animais , Anticorpos/administração & dosagem , Neoplasias da Mama/patologia , Modelos Animais de Doenças , Feminino , Imunofluorescência , Xenoenxertos , Humanos , Camundongos Nus , Camundongos Transgênicos , Microbolhas , Transplante de Neoplasias , Netrina-1/antagonistas & inibidores , Resultado do Tratamento
15.
Clin Cancer Res ; 24(7): 1667-1676, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29298796

RESUMO

Purpose: Intraoperative near-infrared fluorescence (NIRF) imaging could help stratification for the proper primary treatment for patients with pancreatic ductal adenocarcinoma (PDAC), and achieve complete resection, as it allows visualization of cancer in real time. Integrin αvß6, a target specific for PDAC, is present in >90% of patients, and is able to differentiate between pancreatitis and PDAC. A clinically translatable αvß6-targeting NIRF agent was developed, based on a previously developed cysteine knottin peptide for PET imaging, R01-MG, and validated in preclinical mouse models.Experimental Design: The applicability of the agent was tested for cell and tissue binding characteristics using cell-based plate assays, subcutaneous, and orthotopic pancreatic models, and a transgenic mouse model of PDAC development (Pdx1-Cretg/+;KRasLSL G12D/+;Ink4a/Arf-/-). IRDye800CW was conjugated to R01-MG in a 1:1 ratio. R01-MG-IRDye800, was compared with a control peptide and IRDye800 alone.Results: In subcutaneous tumor models, a significantly higher tumor-to-background ratio (TBR) was seen in BxPC-3 tumors (2.5 ± 0.1) compared with MiaPaCa-2 (1.2 ± 0.1; P < 0.001), and to the control peptide (1.6 ± 0.4; P < 0.005). In an orthotopic tumor model, tumor-specific uptake of R01-MG-IRDye800 was shown compared with IRDye800 alone (TBR 2.7 vs. 0.86). The fluorescent signal in tumors of transgenic mice was significantly higher, TBR of 3.6 ± 0.94, compared with the normal pancreas of wild-type controls, TBR of 1.0 ± 0.17 (P < 0.001).Conclusions: R01-MG-IRDye800 shows specific targeting to αvß6, and holds promise as a diagnostic and therapeutic tool to recognize PDAC for fluorescence-guided surgery. This agent can help improve the stratification of patients for a potentially curative, margin-negative resection. Clin Cancer Res; 24(7); 1667-76. ©2018 AACR.


Assuntos
Antígenos de Neoplasias/metabolismo , Miniproteínas Nó de Cistina/farmacologia , Corantes Fluorescentes/metabolismo , Integrinas/metabolismo , Neoplasias Pancreáticas/tratamento farmacológico , Neoplasias Pancreáticas/metabolismo , Peptídeos/farmacologia , Animais , Carcinoma Ductal Pancreático/tratamento farmacológico , Carcinoma Ductal Pancreático/metabolismo , Linhagem Celular Tumoral , Células HCT116 , Humanos , Indóis/metabolismo , Camundongos
16.
Abdom Radiol (NY) ; 43(4): 861-879, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29151131

RESUMO

Contrast-enhanced ultrasound (CEUS) is a specific form of ultrasound imaging performed with intravenous administration of microbubble contrast agents. It has been extensively used for liver tumor characterization and was recently added to the American College of Radiology Liver Imaging Reporting and Data System (CEUS LI-RADS). This paper describes technical recommendations for successful liver CEUS lesion characterization, and provides imaging protocol and Lexicon of imaging findings.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Neoplasias Hepáticas/diagnóstico por imagem , Ultrassonografia/métodos , Algoritmos , Diagnóstico Diferencial , Diagnóstico Precoce , Humanos , Microbolhas , Guias de Prática Clínica como Assunto , Terminologia como Assunto , Ultrassonografia/instrumentação
17.
ACS Nano ; 12(11): 10817-10832, 2018 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-30346694

RESUMO

MicroRNAs are critical regulators of cancer initiation, progression, and dissemination. Extensive evidence suggests that the inhibition of over-expressed oncogenic miRNA function can be a robust strategy for anticancer therapy. However, in vivo targeted delivery of miRNA therapeutics to various types of cancers remains a major challenge. Inspired by their natural synthesis and cargo delivery capabilities, researchers have exploited tumor cell-derived extracellular vesicles (TEVs) for the cancer-targeted delivery of therapeutics and theranostics. Here, we investigate a TEV-based nanoplatform for multimodal miRNA delivery and phototherapy treatments as well as the magnetic resonance imaging of cancer. We demonstrated loading of anti-miR-21 that blocks the function of endogenous oncogenic miR-21 over-expressed in cancer cells into and subsequent delivery by TEVs derived from 4T1 cells. We also produced Cy5-anti-miR-21-loaded TEVs from two other cancer cell lines (HepG2 and SKBR3) and confirmed their robust homologous and heterologous transfection efficiency and intracellular Cy5-anti-miR-21 delivery. Additionally, TEV-mediated anti-miR-21 delivery attenuated doxorubicin (DOX) resistance in breast cancer cells with a 3-fold higher cell kill efficiency than in cells treated with DOX alone. We then investigated TEVs as a biomimetic source for the functionalization of gold-iron oxide nanoparticles (GIONs) and demonstrated nanotheranostic properties of TEV-GIONs in vitro. TEV-GIONs demonstrated excellent T2 contrast in in vitro magnetic resonance (MR) imaging and resulted in efficient photothermal effect in 4T1 cells. We also evaluated the biodistribution and theranostic property of anti-miR-21 loaded TEV-GIONs in vivo by labeling with indocyanine green near-infrared dye. We further validated the tumor specific accumulation of TEV-GIONs using MR imaging. Our findings demonstrate that the distribution pattern of the TEV-anti-miR-21-GIONs correlated well with the tumor-targeting capability as well as the activity and efficacy obtained in response to doxorubicin combination treatments. TEVs and TEV-GIONs are promising nanotheranostics for future applications in cancer molecular imaging and therapy.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Neoplasias da Mama/terapia , Doxorrubicina/administração & dosagem , Portadores de Fármacos/química , Vesículas Extracelulares/química , MicroRNAs/antagonistas & inibidores , Nanopartículas/química , Nanomedicina Teranóstica , Animais , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/metabolismo , Células HEK293 , Humanos , Imageamento por Ressonância Magnética , Camundongos , MicroRNAs/química , Imagem Molecular , Fototerapia
19.
Mol Imaging Biol ; 20(1): 65-73, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28616842

RESUMO

PURPOSE: Magneto-endosymbionts (MEs) show promise as living magnetic resonance imaging (MRI) contrast agents for in vivo cell tracking. Here we characterize the biomedical imaging properties of ME contrast agents, in vitro and in vivo. PROCEDURES: By adapting and engineering magnetotactic bacteria to the intracellular niche, we are creating magneto-endosymbionts (MEs) that offer advantages relative to passive iron-based contrast agents (superparamagnetic iron oxides, SPIOs) for cell tracking. This work presents a biomedical imaging characterization of MEs including: MRI transverse relaxivity (r 2) for MEs and ME-labeled cells (compared to a commercially available iron oxide nanoparticle); microscopic validation of labeling efficiency and subcellular locations; and in vivo imaging of a MDA-MB-231BR (231BR) human breast cancer cells in a mouse brain. RESULTS: At 7T, r 2 relaxivity of bare MEs was higher (250 s-1 mM-1) than that of conventional SPIO (178 s-1 mM-1). Optimized in vitro loading of MEs into 231BR cells yielded 1-4 pg iron/cell (compared to 5-10 pg iron/cell for conventional SPIO). r 2 relaxivity dropped by a factor of ~3 upon loading into cells, and was on the same order of magnitude for ME-loaded cells compared to SPIO-loaded cells. In vivo, ME-labeled cells exhibited strong MR contrast, allowing as few as 100 cells to be detected in mice using an optimized 3D SPGR gradient-echo sequence. CONCLUSIONS: Our results demonstrate the potential of magneto-endosymbionts as living MR contrast agents. They have r 2 relaxivity values comparable to traditional iron oxide nanoparticle contrast agents, and provide strong MR contrast when loaded into cells and implanted in tissue.


Assuntos
Rastreamento de Células , Imageamento por Ressonância Magnética , Nanopartículas de Magnetita/química , Simbiose , Animais , Linhagem Celular Tumoral , Sobrevivência Celular , Feminino , Humanos , Camundongos Nus
20.
Theranostics ; 7(5): 1303-1329, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28435467

RESUMO

Elastography-based imaging techniques have received substantial attention in recent years for non-invasive assessment of tissue mechanical properties. These techniques take advantage of changed soft tissue elasticity in various pathologies to yield qualitative and quantitative information that can be used for diagnostic purposes. Measurements are acquired in specialized imaging modes that can detect tissue stiffness in response to an applied mechanical force (compression or shear wave). Ultrasound-based methods are of particular interest due to its many inherent advantages, such as wide availability including at the bedside and relatively low cost. Several ultrasound elastography techniques using different excitation methods have been developed. In general, these can be classified into strain imaging methods that use internal or external compression stimuli, and shear wave imaging that use ultrasound-generated traveling shear wave stimuli. While ultrasound elastography has shown promising results for non-invasive assessment of liver fibrosis, new applications in breast, thyroid, prostate, kidney and lymph node imaging are emerging. Here, we review the basic principles, foundation physics, and limitations of ultrasound elastography and summarize its current clinical use and ongoing developments in various clinical applications.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA