Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Magn Reson Med ; 84(6): 3117-3127, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32573807

RESUMO

PURPOSE: Diffusion weighted imaging (DWI) is commonly limited by low signal-to-noise ratio (SNR) as well as motion artifacts. To address this limitation, a method that allows to maximize the achievable signal yield and increase the resolution in motion robust single-shot DWI is presented. METHODS: DWI was performed on a 3T scanner equipped with a recently developed gradient insert (gradient strength: 200 mT/m, slew rate: 600 T/m/s). To further shorten the echo time, Stejskal-Tanner diffusion encoding with a single-shot spiral readout was implemented. To allow non-Cartesian image reconstruction using such strong and fast gradients, the characterization of eddy current and concomitant field effects was performed based on field-camera measurements. RESULTS: An echo time of only 19 ms was achieved for a b-factor of 1000 s/mm2 . An in-plane resolution of 0.68 mm was encoded by a single-shot spiral readout of 40.5 ms using 3-fold undersampling. The resulting images did not suffer from off-resonance artifacts and T 2 ∗ blurring that are common to single-shot images acquired with regular gradient systems. CONCLUSION: Spiral diffusion imaging using a head gradient system, together with an accurate characterization of the encoding process allows for a substantial reduction of the echo time, and improves the achievable resolution in motion-insensitive single-shot DWI.


Assuntos
Encéfalo , Imagem Ecoplanar , Artefatos , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador
2.
Magn Reson Med ; 83(6): 2173-2184, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31840300

RESUMO

PURPOSE: In diffusion MRI, the actual b-value played out on the scanner may deviate from the nominal value due to magnetic field imperfections. A simple image-based correction method for this problem is presented. METHODS: The apparent diffusion constant (ADC) of a water phantom was measured voxel-wise along 64 diffusion directions at b = 1000 s/mm2 . The true diffusion constant of water was estimated, considering the phantom temperature. A voxel-wise correction factor, providing an effective b-value including any magnetic field deviations, was determined for each diffusion direction by relating the measured ADC to the true diffusion constant. To test the method, the measured b-value map was used to calculate the corrected voxel-wise ADC for additionally acquired diffusion data sets on the same water phantom and data sets acquired on a small water phantom at three different positions. Diffusion tensor was estimated by applying the measured b-value map to phantom and in vivo data sets. RESULTS: The b-value-corrected ADC maps of the phantom showed the expected spatial uniformity as well as a marked improvement in consistency across diffusion directions. The b-value correction for the brain data resulted in a 5.8% and 5.5% decrease in mean diffusivity and angular differences of the primary diffusion direction of 2.71° and 0.73° inside gray and white matter, respectively. CONCLUSION: The actual b-value deviates significantly from its nominal setting, leading to a spatially variable error in the common diffusion outcome measures. The suggested method measures and corrects these artifacts.


Assuntos
Artefatos , Imagem de Difusão por Ressonância Magnética , Difusão , Imagens de Fantasmas , Reprodutibilidade dos Testes
3.
Magn Reson Med ; 79(2): 770-778, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28556247

RESUMO

PURPOSE: To assess the potential of a real-time field-control (FC) system for mitigating effects of spatiotemporal field fluctuations in quantitative susceptibility mapping (QSM) at 7 T. METHODS: Magnitude, phase, and QSM images of phantoms and healthy volunteers were acquired under standard conditions and under induced field perturbation (FP) (phantoms: periodic water-bottle displacement; volunteers: deep breathing and forearm movement) with and without FC, which continuously detects and minimizes magnetic-field variations. RESULTS: Field control successfully eliminated FP-induced impairment of phantom image quality and deviations from a linear susceptibility increase for increasing gadolinium concentration in a Gd dilution series (y = 320x - 0.60, R2 = 0.93 for the scan with FP and FC versus y = 259x - 0.54, R2 = 0.78 for the scan with FP and no FC (slope literature value: 326 ppm L/mol)). Similarly, in volunteers, FC allowed a recovery of a FP-induced loss of identifiable brain structures and reduced the relative change of mean susceptibilities and standard deviations (93 ± 53% to 34 ± 46%) in all regions of interests with respect to the reference scan. CONCLUSIONS: Real-time FC improved the delineation of brain structures and the match of susceptibility values with reference values obtained without FP. Magn Reson Med 79:770-778, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Encéfalo/diagnóstico por imagem , Humanos , Imagens de Fantasmas
4.
Magn Reson Med ; 79(6): 3256-3266, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-28983969

RESUMO

PURPOSE: The goal of this study was to devise a gradient system for MRI in humans that reconciles cutting-edge gradient strength with rapid switching and brings up the duty cycle to 100% at full continuous amplitude. Aiming to advance neuroimaging and short-T2 techniques, the hardware design focused on the head and the extremities as target anatomies. METHODS: A boundary element method with minimization of power dissipation and stored magnetic energy was used to design anatomy-targeted gradient coils with maximally relaxed geometry constraints. The design relies on hollow conductors for high-performance cooling and split coils to enable dual-mode gradient amplifier operation. With this approach, strength and slew rate specifications of either 100 mT/m with 1200 mT/m/ms or 200 mT/m with 600 mT/m/ms were reached at 100% duty cycle, assuming a standard gradient amplifier and cooling unit. RESULTS: After manufacturing, the specified values for maximum gradient strength, maximum switching rate, and field geometry were verified experimentally. In temperature measurements, maximum local values of 63°C were observed, confirming that the device can be operated continuously at full amplitude. Testing for peripheral nerve stimulation showed nearly unrestricted applicability in humans at full gradient performance. In measurements of acoustic noise, a maximum average sound pressure level of 132 dB(A) was determined. In vivo capability was demonstrated by head and knee imaging. Full gradient performance was employed with echo planar and zero echo time readouts. CONCLUSION: Combining extreme gradient strength and switching speed without duty cycle limitations, the described system offers unprecedented options for rapid and short-T2 imaging. Magn Reson Med 79:3256-3266, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Desenho de Equipamento , Humanos , Joelho/diagnóstico por imagem , Masculino , Dinâmica não Linear , Imagens de Fantasmas , Temperatura
5.
NMR Biomed ; 30(10)2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28678353

RESUMO

T2 * mapping offers access to a number of important structural and physiological tissue parameters. It is robust against RF field variations and overall signal scaling. However, T2 * measurement is highly sensitive to magnetic field errors, including perturbations caused by breathing motion at high baseline field. The goal of this work is to assess this issue in T2 * mapping of the brain and to study the benefit of field stabilization by feedback field control. T2 * quantification in the brain was investigated by phantom and in vivo measurements at 7 T. Repeated measurements were made with and without feedback field control using NMR field sensing and dynamic third-order shim actuation. The precision and reliability of T2 * quantification was assessed by studying variation across repeated measurements as well as fitting errors. Breathing effects were found to introduce significant error in T2 * mapping results. Field control mitigates this problem substantially. In a phantom it virtually eliminates the effects of emulated breathing fluctuations in the head. In vivo it enhances the structural fidelity of T2 * maps and reduces fitting residuals along with standard deviation. In conclusion, feedback field control improves the fidelity of T2 * mapping in the presence of field perturbations. It is an effective means of countering bulk susceptibility effects of breathing and hence holds particular promise for efforts to leverage high field for T2 * studies in vivo.


Assuntos
Retroalimentação , Imageamento por Ressonância Magnética/métodos , Adulto , Humanos , Masculino , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA