Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Opt Express ; 31(7): 11261-11273, 2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37155766

RESUMO

To study nanostructures on substrates, surface-sensitive reflection-geometry scattering techniques such as grazing incident small angle X-ray scattering are commonly used to yield an averaged statistical structural information of the surface sample. Grazing incidence geometry can probe the absolute three-dimensional structural morphology of the sample if a highly coherent beam is used. Coherent surface scattering imaging (CSSI) is a powerful yet non-invasive technique similar to coherent X-ray diffractive imaging (CDI) but performed at small angles and grazing-incidence reflection geometry. A challenge with CSSI is that conventional CDI reconstruction techniques cannot be directly applied to CSSI because the Fourier-transform-based forward models cannot reproduce the dynamical scattering phenomenon near the critical angle of total external reflection of the substrate-supported samples. To overcome this challenge, we have developed a multislice forward model which can successfully simulate the dynamical or multi-beam scattering generated from surface structures and the underlying substrate. The forward model is also demonstrated to be able to reconstruct an elongated 3D pattern from a single shot scattering image in the CSSI geometry through fast-performing CUDA-assisted PyTorch optimization with automatic differentiation.

2.
J Synchrotron Radiat ; 28(Pt 4): 1081-1089, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34212871

RESUMO

The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 µm was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. The technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.

3.
Opt Express ; 22(12): 14041-53, 2014 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-24977503

RESUMO

Transverse coherence of the x-ray beam from a bending magnet source was studied along multiple directions using a 2-D π/2 phase grating by measuring interferogram visibilities at different distances behind the grating. These measurements suggest that the preferred measuring orientation of a 2-D checkerboard grating is along the diagonal directions of the square blocks, where the interferograms have higher visibility and are not sensitive to the deviation of the duty cycle of the grating period. These observations are verified by thorough wavefront propagation simulations. The accuracy of the measured coherence values was also validated by the simulation and analytical results obtained from the source parameters. In addition, capability of the technique in probing spatially resolved local transverse coherence is demonstrated.

4.
J Vis Exp ; (116)2016 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-27768076

RESUMO

A procedure for a technique to measure the transverse coherence of synchrotron radiation X-ray sources using a single phase grating interferometer is reported. The measurements were demonstrated at the 1-BM bending magnet beamline of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). By using a 2-D checkerboard π/2 phase-shift grating, transverse coherence lengths were obtained along the vertical and horizontal directions as well as along the 45° and 135° directions to the horizontal direction. Following the technical details specified in this paper, interferograms were measured at different positions downstream of the phase grating along the beam propagation direction. Visibility values of each interferogram were extracted from analyzing harmonic peaks in its Fourier Transformed image. Consequently, the coherence length along each direction can be extracted from the evolution of visibility as a function of the grating-to-detector distance. The simultaneous measurement of coherence lengths in four directions helped identify the elliptical shape of the coherence area of the Gaussian-shaped X-ray source. The reported technique for multiple-direction coherence characterization is important for selecting the appropriate sample size and orientation as well as for correcting the partial coherence effects in coherence scattering experiments. This technique can also be applied for assessing coherence preserving capabilities of X-ray optics.


Assuntos
Síncrotrons , Raios X , Óptica e Fotônica , Fótons
5.
Rev Sci Instrum ; 87(5): 052004, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27250384

RESUMO

We developed a portable X-ray grating interferometer setup as a standard tool for testing optics at the Advanced Photon Source (APS) beamline 1-BM. The interferometer can be operated in phase-stepping, Moiré, or single-grating harmonic imaging mode with 1-D or 2-D gratings. All of the interferometer motions are motorized; hence, it is much easier and quicker to switch between the different modes of operation. A novel aspect of this new instrument is its designed portability. While the setup is designed to be primarily used as a standard tool for testing optics at 1-BM, it could be potentially deployed at other APS beamlines for beam coherence and wavefront characterization or imaging. The design of the interferometer system is described in detail and coherence measurements obtained at the APS 34-ID-E beamline are presented. The coherence was probed in two directions using a 2-D checkerboard, a linear, and a circular grating at X-ray energies of 8 keV, 11 keV, and 18 keV.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA