Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Adv Sci (Weinh) ; 11(30): e2402951, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38874370

RESUMO

Composite DNA letters, by merging all four DNA nucleotides in specified ratios, offer a pathway to substantially increase the logical density of DNA digital storage (DDS) systems. However, these letters are susceptible to nucleotide errors and sampling bias, leading to a high letter error rate, which complicates precise data retrieval and augments reading expenses. To address this, Derrick-cp is introduced as an innovative soft-decision decoding algorithm tailored for DDS utilizing composite letters. Derrick-cp capitalizes on the distinctive error sensitivities among letters to accurately predict and rectify letter errors, thus enhancing the error-correcting performance of Reed-Solomon codes beyond traditional hard-decision decoding limits. Through comparative analyses in the existing dataset and simulated experiments, Derrick-cp's superiority is validated, notably halving the sequencing depth requirement and slashing costs by up to 22% against conventional hard-decision strategies. This advancement signals Derrick-cp's significant role in elevating both the precision and cost-efficiency of composite letter-based DDS.


Assuntos
Algoritmos , DNA , DNA/genética , Armazenamento e Recuperação da Informação/métodos
2.
Natl Sci Rev ; 11(2): nwad229, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38213525

RESUMO

Error-correcting codes (ECCs) employed in the state-of-the-art DNA digital storage (DDS) systems suffer from a trade-off between error-correcting capability and the proportion of redundancy. To address this issue, in this study, we introduce soft-decision decoding approach into DDS by proposing a DNA-specific error prediction model and a series of novel strategies. We demonstrate the effectiveness of our approach through a proof-of-concept DDS system based on Reed-Solomon (RS) code, named as Derrick. Derrick shows significant improvement in error-correcting capability without involving additional redundancy in both in vitro and in silico experiments, using various sequencing technologies such as Illumina, PacBio and Oxford Nanopore Technology (ONT). Notably, in vitro experiments using ONT sequencing at a depth of 7× reveal that Derrick, compared with the traditional hard-decision decoding strategy, doubles the error-correcting capability of RS code, decreases the proportion of matrices with decoding-failure by 229-fold, and amplifies the potential maximum storage volume by impressive 32 388-fold. Also, Derrick surpasses 'state-of-the-art' DDS systems by comprehensively considering the information density and the minimum sequencing depth required for complete information recovery. Crucially, the soft-decision decoding strategy and key steps of Derrick are generalizable to other ECCs' decoding algorithms.

3.
RSC Adv ; 14(12): 8293-8302, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38469193

RESUMO

In this paper, the SiCN(Ni)/BN ceramic with excellent electromagnetic wave (EMW) absorption performance was successfully prepared. The Ni and Ni3Si were in situ formed by the introduction of nickel acetylacetonate (NA), which effectively improved the impedance matching performance of SiCN(Ni)/BN ceramics. The EMW absorption properties of the SiCN(Ni)/BN ceramics showed a trend of first increasing and then decreasing with the increase in content of NA. When the NA content reached 7 wt%, the impedance matching range of SiCN-7 was optimal. The minimum reflection loss (RLmin) of SiCN-7 reached -53.47 dB at 4.2 mm and the effective absorption bandwidth (EAB) was 2.32 GHz at 3.48 mm. Through the analysis of electrical conductivity, it was found that the proportion of polarization loss in dielectric loss was more than 99%. It is worth noting that the radar cross section (RCS) value of SiCN-7 absorber was lower than that of the perfect electrical conductor (PEC) plate in the range of -90-90°, and showed a larger coverage angle, indicating that it possessed a good practical application prospect in the field of electromagnetic wave absorption.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA