Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 218(1): 132-139, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34406050

RESUMO

BACKGROUND. Sequences with noncartesian k-space sampling may improve image quality of head and neck MRI. OBJECTIVE. The purpose of this study was to compare intraindividually the image quality of a spiral gradient-recalled echo (GRE) sequence and conventional cartesian GRE and cartesian turbo spin-echo (TSE) sequences for contrast-enhanced T1-weighted head and neck MRI. METHODS. This prospective study included patients referred for contrast-enhanced head and neck MRI from August 2020 to May 2021. Patients underwent 1.5-T MRI including contrast-enhanced spiral GRE (2 minutes 28 seconds), cartesian GRE (4 minutes 27 seconds), and cartesian TSE (3 minutes 41 seconds) sequences, acquired in rotating order across patients. Three radiologists independently assessed image quality measures, including conspicuity of prespecified lesions, using 5-point Likert scales. One reader measured maximal extent of dental material artifact and contrast-to-noise ratio (CNR). RESULTS. Thirty-one patients (13 men, 18 women; mean age, 63.8 years) were enrolled. Nineteen patients had a focal lesion; 22 had dental material. Interreader agreement for image quality measures was substantial to excellent (Krippendorff alpha, 0.681-1.000). Scores for overall image quality (whole head and neck, neck only, and head only), pulsation artifact, muscular contour delineation, vessel contour delineation, motion artifact, and differentiation between mucosa and pharyngeal muscles were significantly better for spiral GRE than for cartesian GRE and cartesian TSE for all readers (p < .05). Scores for lesion conspicuity (whole head and neck, neck only, and head only), quality of fat suppression, flow artifact, and foldover artifact were not significantly different between spiral GRE and the cartesian sequences for any reader (p > .05). Dental material artifact scores were significantly worse for spiral GRE than the other sequences for all readers (p < .05). The mean maximum extent of dental material artifact was 39.6 ± 25.5 (SD) mm for spiral GRE, 35.6 ± 24.3 mm for cartesian GRE, and 29.6 ± 21.4 mm for cartesian TSE; the mean CNR was 221.1 ± 94.5 for spiral GRE, 151.8 ± 85.7 for cartesian GRE, and 153.0 ± 63.2 for cartesian TSE (p < .001 between spiral GRE and other sequences for both measures). CONCLUSION. Three-dimensional spiral GRE improves subjective image quality and CNR of head and neck MRI with shorter scan time versus cartesian sequences, though it exhibits larger dental material artifact. CLINICAL IMPACT. A spiral sequence may help overcome certain challenges of conventional cartesian sequences for head and neck MRI.


Assuntos
Meios de Contraste , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Cabeça/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes
2.
Neuroimage ; 186: 399-409, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30342237

RESUMO

PURPOSE: The lateral geniculate nucleus (LGN) is an essential nucleus of the visual pathway, occupying a small volume (60-160 mm3) among the other thalamic nuclei. The reported LGN volumes vary greatly across studies due to technical limitations and due to methodological differences of volume assessment. Yet, structural and anatomical alterations in ophthalmologic and neurodegenerative pathologies can only be revealed by a precise and reliable LGN representation. To improve LGN volume assessment, we first implemented a reference acquisition for LGN volume determination with optimized Contrast to Noise Ratio (CNR) and high spatial resolution. Next, we compared CNR efficiency and rating reliability of 3D Magnetization Prepared Rapid Gradient Echo (MPRAGE) images using white matter nulled (WMn) and grey matter nulled (GMn) sequences and its subtraction (WMn-GMn) relative to the clinical standard Proton Density Turbo Spin Echo (PD 2D TSE) and the reference acquisition. We hypothesized that 3D MPRAGE should provide a higher CNR and volume determination accuracy than the currently used 2D sequences. MATERIALS AND METHODS: In 31 healthy subjects, we obtained at 3 and 7 T the following MR sequences: PD-TSE, MPRAGE with white/grey matter signal nulled (WMn/GMn), and a motion-corrected segmented MPRAGE sequence with a resolution of 0.4 × 0.4 × 0.4 mm3 (reference acquisition). To increase CNR, GMn were subtracted from WMn (WMn-GMn). Four investigators manually segmented the LGN independently. RESULTS: The reference acquisition provided a very sharp depiction of the LGN and an estimated mean LGN volume of 124 ±â€¯3.3 mm3. WMn-GMn had the highest CNR and gave the most reproducible LGN volume estimations between field strengths. Even with the highest CNR efficiency, PD-TSE gave inconsistent LGN volumes with the weakest reference acquisition correlation. The LGN WM rim induced a significant difference between LGN volumes estimated from WMn and GMn. WMn and GMn LGN volume estimations explained most of the reference acquisition volumes' variance. For all sequences, the volume rating reliability were good. On the other hand, the best CNR rating reliability, LGN volume and CNR correlations with the reference acquisition were obtained with GMn at 7 T. CONCLUSION: WMn and GMn MPRAGE allow reliable LGN volume determination at both field strengths. The precise location and identification of the LGN (volume) can help to optimize neuroanatomical and neurophysiological studies, which involve the LGN structure. Our optimized imaging protocol may be used for clinical applications aiming at small nuclei volumetric and CNR quantification.


Assuntos
Corpos Geniculados/anatomia & histologia , Corpos Geniculados/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Feminino , Humanos , Aumento da Imagem , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Adulto Jovem
3.
BMC Ophthalmol ; 19(1): 258, 2019 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-31842814

RESUMO

BACKGROUND: In this retrospective study the relationship between intraocular pressure (IOP), retinal nerve fiber layer (RNFL) thickness and pathologic hypersignal in optic nerve segments on 3D double inversion recovery (DIR) MR sequence in 21 patients with proven glaucoma of different origin was evaluated. METHODS: All patients were examined on a 3 T MR Philips® scanner. Pathologic optic nerve DIR hypersignal was determined in four different nerve segments. IOP was measured in mmHg by applanation tonometry. RNFL thickness was measured in µm with optical coherence tomography (OCT Heidelberg Engineering Spectralis® apparatus). Wilcoxon rank sum tests, student's t-tests and (multivariate) linear regression models were appied. RESULTS: 3D DIR hypersignal was present in 17 (41.5%) optic nerves. 3D DIR hypersignal was not related to ischemic or demyelinating optic nerve pathology but was associated with increased IOP (19.8 [24-18]; versus 15.45; [18.85-13.75] mmHg; p = 0.008) and decreased RNFL thickness (61.06 ± 12.1 versus 82.5 ± 21.6 µm; p < 0.001) in comparison to optic nerves of glaucoma patients without DIR hypersignal. Specifically, presence of DIR hypersignal in optic nerves in at least one optic nerve segment lowered RNFL thickness on average by 17.54 µm (p = 0.005) in comparison to optic nerves without DIR hypersignal. CONCLUSIONS: In patients with glaucomatous optic neuropathy (GON) and pathologic optic nerve DIR hypersignal, significantly increased IOP and significantly decreased RNFL thickness values are present. DIR hypersignal seems to be a marker for disease severity in GON related to decreased RNFL thickness and may thus represent long-segment severe axonal degeneration in optic nerves in patients with GON. Venous congestion and edema within the optic nerve related to high IOP may contribute to the DIR hypersignal as well.


Assuntos
Glaucoma de Ângulo Fechado/fisiopatologia , Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Fibras Nervosas/patologia , Doenças do Nervo Óptico/fisiopatologia , Células Ganglionares da Retina/patologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Glaucoma de Ângulo Fechado/diagnóstico por imagem , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Doenças do Nervo Óptico/diagnóstico por imagem , Estudos Retrospectivos , Tomografia de Coerência Óptica , Tonometria Ocular , Testes de Campo Visual , Campos Visuais/fisiologia
4.
Neuroimage ; 162: 162-172, 2017 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-28882631

RESUMO

The trigeminal brainstem sensory nuclear complex is the first central relay structure mediating orofacial somatosensory and nociceptive perception. Animal studies suggest a substantial involvement of neurochemical alterations at such basal CNS levels in acute and chronic pain processing. Translating this animal based knowledge to humans is challenging. Human related examining of brainstem functions are challenged by MR related peculiarities as well as applicability aspects of experimentally standardized paradigms. Based on our experience with an MR compatible human orofacial pain model, the aims of the present study were twofold: 1) from a technical perspective, the evaluation of proton magnetic resonance spectroscopy at 3 T regarding measurement accuracy of neurochemical profiles in this small brainstem nuclear complex and 2) the examination of possible neurochemical alterations induced by an experimental orofacial pain model. Data from 13 healthy volunteers aged 19-46 years were analyzed and revealed high quality spectra with significant reductions in total N-acetylaspartate (N-acetylaspartate + N-acetylaspartylglutamate) (-3.7%, p = 0.009) and GABA (-10.88%, p = 0.041) during the pain condition. These results might reflect contributions of N-acetylaspartate and N-acetylaspartylglutamate in neuronal activity-dependent physiologic processes and/or excitatory neurotransmission, whereas changes in GABA might indicate towards a reduction in tonic GABAergic functioning during nociceptive signaling. Summarized, the present study indicates the applicability of 1H-MRS to obtain neurochemical dynamics within the human trigeminal brainstem sensory nuclear complex. Further developments are needed to pave the way towards bridging important animal based knowledge with human research to understand the neurochemistry of orofacial nociception and pain.


Assuntos
Dor Facial/metabolismo , Espectroscopia de Prótons por Ressonância Magnética/métodos , Núcleos do Trigêmeo/metabolismo , Adulto , Ácido Aspártico/análogos & derivados , Ácido Aspártico/análise , Ácido Aspártico/metabolismo , Dipeptídeos/análise , Dipeptídeos/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Ácido gama-Aminobutírico/análise , Ácido gama-Aminobutírico/metabolismo
5.
NMR Biomed ; 30(10)2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28678353

RESUMO

T2 * mapping offers access to a number of important structural and physiological tissue parameters. It is robust against RF field variations and overall signal scaling. However, T2 * measurement is highly sensitive to magnetic field errors, including perturbations caused by breathing motion at high baseline field. The goal of this work is to assess this issue in T2 * mapping of the brain and to study the benefit of field stabilization by feedback field control. T2 * quantification in the brain was investigated by phantom and in vivo measurements at 7 T. Repeated measurements were made with and without feedback field control using NMR field sensing and dynamic third-order shim actuation. The precision and reliability of T2 * quantification was assessed by studying variation across repeated measurements as well as fitting errors. Breathing effects were found to introduce significant error in T2 * mapping results. Field control mitigates this problem substantially. In a phantom it virtually eliminates the effects of emulated breathing fluctuations in the head. In vivo it enhances the structural fidelity of T2 * maps and reduces fitting residuals along with standard deviation. In conclusion, feedback field control improves the fidelity of T2 * mapping in the presence of field perturbations. It is an effective means of countering bulk susceptibility effects of breathing and hence holds particular promise for efforts to leverage high field for T2 * studies in vivo.


Assuntos
Retroalimentação , Imageamento por Ressonância Magnética/métodos , Adulto , Humanos , Masculino , Imagens de Fantasmas
6.
Magn Reson Med ; 76(2): 430-9, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26307944

RESUMO

PURPOSE: Real-time field control can serve to reduce respiratory field perturbations during T2 * imaging at high fields. This work investigates the effectiveness of this approach in relation to key variables such as patient physique, breathing patterns, slice location, and the choice of sequence. METHODS: To cover variation in physical constitution and breathing behavior, volunteers with a wide range of body-mass-indices were asked to breathe either normally or deeply during T2 *-weighted image acquisition at 7T. Ensuing field fluctuation was countered by real-time field control or merely recorded in reference experiments. The impact of the control system on image quality was assessed by classifying and grading artifacts related to field fluctuation. RESULTS: The amplitude of respiratory field changes and related artifacts were generally stronger for subjects with higher body-mass-index and for lower slices. Field control was found effective at mitigating all five types of artifacts that were studied. Overall image quality was systematically improved. Residual artifacts in low slices are attributed to insufficient spatial order of the control system. CONCLUSION: Real-time field control was found to be a robust means of countering respiratory field perturbations in variable conditions encountered in high-field brain imaging. Reducing net fluctuation, it generally expands the feasibility of high-field T2 * imaging toward challenging patients and brain regions. Magn Reson Med 76:430-439, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Artefatos , Encéfalo/anatomia & histologia , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Algoritmos , Sistemas Computacionais , Campos Eletromagnéticos , Feminino , Humanos , Masculino , Radiometria/métodos , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade
7.
J Comput Assist Tomogr ; 40(1): 183-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26466110

RESUMO

OBJECTIVE: The aim of this study was to demonstrate the feasibility of whole-body diffusion tensor imaging (DTI) as a promising tool for research applications, for instance, for investigation of systemic muscle diseases. MATERIALS AND METHODS: Twelve healthy volunteers (mean age, 26.6 years; range, 20-39 years) underwent whole-body magnetic resonance imaging at 3 T using an echo planar imaging sequence (b value, 400 s/mm) with 6 different spatial encoding directions. Coronal maps of DTI parameters including mean diffusivity, fractional anisotropy, and diffusion tensor eigenvalues (λ1-3) were generated using in-house MATLAB routines. Diffusion tensor imaging parameters were evaluated by region-of-interest analysis in skeletal muscle, cerebral gray and white matter, the kidneys, and the liver. RESULTS: The acquisition time was 79 minutes 12 seconds. The different organs could be clearly depicted on the parametrical maps. Exemplary values in skeletal muscle were mean diffusivity, 1.67 ± 0.16 × 10(-3) mm2/s; fractional anisotropy, 0.26 ± 0.03; λ1, 2.17 ± 0.20 × 10(-3) mm2/s; λ2, 1.64 ± 0.17 × 10(-3) mm2/s; and λ3, 1.22 ± 0.12 × 10(-3) mm2/s. CONCLUSION: Whole-body DTI is technically feasible. Further refinements are required to achieve a higher signal-to-noise ratio and improved spatial resolution. A possible clinical application could be the assessment of systemic myopathies.


Assuntos
Imagem de Tensor de Difusão , Imagem Corporal Total , Adulto , Encéfalo/anatomia & histologia , Imagem Ecoplanar , Estudos de Viabilidade , Feminino , Humanos , Rim/anatomia & histologia , Fígado/anatomia & histologia , Masculino , Músculo Esquelético/anatomia & histologia , Estudos Prospectivos , Valores de Referência , Adulto Jovem
8.
Magn Reson Med ; 71(5): 1657-62, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23798466

RESUMO

PURPOSE: Magnetic resonance spectroscopy (MRS) experiments rely on a homogeneous and stable magnetic field within the sample. Field homogeneity is typically optimized by static B0 shimming while reproducible effects from dynamic field variation are commonly diminished by means of gradient system calibration as well as calibration based on non-water suppressed reference data. However, residual encoding deficiencies from incomplete calibration and nonreproducible field perturbations deteriorate the quality of the obtained data. To overcome this problem, we propose to adapt higher-order feedback field control based on NMR field probes for its application in MRS. METHODS: To allow for field measurements simultaneously with the spectroscopy readout, radiofrequency-shielded field probes were employed. The setup was evaluated in vitro and tested in vivo for single-voxel MRS at 7T to correct for field perturbations that occur due to subject breathing and limb motion. RESULTS: The in vitro experiments showed an effective field control during the MRS sequence. The resulting spectroscopy data were free of spurious signal and the achieved field stabilization improved the spectral resolution in vitro and in vivo. CONCLUSION: High-field MRS is limited by nonreproducible field perturbations for which spatiotemporal field feedback provides a solution without compromising sequence timing and efficiency.


Assuntos
Algoritmos , Artefatos , Espectroscopia de Prótons por Ressonância Magnética/instrumentação , Espectroscopia de Prótons por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Retroalimentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Tomography ; 8(1): 257-266, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35202186

RESUMO

Radiculopathy can be caused by nerve root irritation and nerve root compression at the level of the lateral recess or at the level of the intervertebral foramen. T2-weighted (T2w) MRI is considered essential to evaluate the nerve root and its course, starting at the lateral recess through the intervertebral foramen to the extraforaminal space. With the introduction of novel MRI acceleration techniques such as compressed SENSE, standard-resolution 2D T2w turbo spin echo (TSE) sequences with a slice-thickness of 3-4 mm can be replaced with high-resolution isotropic 3D T2w TSE sequences with sub-millimeter resolution without prolonging scan time. With high-resolution 3D MRI, the course of the nerve root can be visualized more precisely due to a detailed depiction of the anatomical situation and less partial volume effects, potentially allowing for a better detection of nerve root compromise. In this intra-individual comparison study, 55 patients with symptomatic unilateral singular nerve root radiculopathy underwent MRI with both 2D standard- and 3D high-resolution T2w TSE MRI sequences. Two readers graded the degree of lumbar lateral recess stenosis and lumbar foraminal stenosis twice on both image sets using previously validated grading systems in an effort to quantify the inter-readout and inter-sequence agreement of scores. Inter-readout agreement was high for both grading systems and for 2D and 3D imaging (Kappa = 0.823-0.945). Inter-sequence agreement was moderate for both lumbar lateral recess stenosis (Kappa = 0.55-0.577) and lumbar foraminal stenosis (Kappa = 0.543-0.572). The percentage of high degree stenosis with nerve root deformity increased from 16.4%/9.8% to 41.8-43.6%/34.1% from 2D to 3D images for lateral recess stenosis/foraminal stenosis, respectively. Therefore, we show that while inter-readout agreement of grading systems is high for both standard- and high-resolution imaging, the latter outperforms standard-resolution imaging for the visualization of lumbar nerve root compromise.


Assuntos
Imageamento por Ressonância Magnética , Radiculopatia , Imagem de Difusão por Ressonância Magnética , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Radiculopatia/diagnóstico por imagem , Raízes Nervosas Espinhais/diagnóstico por imagem
10.
Br J Radiol ; 95(1135): 20210354, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34762522

RESUMO

OBJECTIVES: To compare a novel 3D spiral gradient echo (GRE) sequence with a conventional 2D cartesian turbo spin echo (TSE) sequence for sagittal contrast-enhanced (CE) fat-suppressed (FS) T1 weighted (T1W) spine MRI. METHODS: In this inter-individual comparison study, 128 patients prospectively underwent sagittal CE FS T1W spine MRI with either a 2D cartesian TSE ("TSE", 285 s, 64 patients) or a 3D spiral GRE sequence ("Spiral", 93 s, 64 patients). Between both groups, patients were matched in terms of anatomical region (cervical/thoracic/lumbar spine and sacrum). Three readers used 4-point Likert scales to assess images qualitatively in terms of overall image quality, presence of artifacts, spinal cord visualization, lesion conspicuity and quality of fat suppression. RESULTS: Spiral achieved a 67.4% scan time reduction compared to TSE. Interreader agreement was high (alpha=0.868-1). Overall image quality (4;[3,4] vs 3;[3,4], p<0.001 - p=0.002 for all readers), presence of artifacts (4;[3,4] vs 3;[3,4] p=0.027 - p=0.046 for all readers), spinal cord visualization (4;[4,4] vs 4;[3,4], p<0.001 for all readers), lesion conspicuity (4;[4,4] vs 4;[4,4], p=0.016 for all readers) and quality of fat suppression (4;[4,4] vs 4;[4,4], p=0.027 - p=0.033 for all readers), were all deemed significantly improved by all three readers on Spiral images as compared to TSE images. CONCLUSION: We demonstrate the feasibility of a novel 3D spiral GRE sequence for improved and rapid sagittal CE FS T1W spine MRI. ADVANCES IN KNOWLEDGE: A 3D spiral GRE sequence allows for improved sagittal CE FS T1W spine MRI at very short scan times.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Pelve , Coluna Vertebral
11.
Phys Med ; 93: 20-28, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34902771

RESUMO

PURPOSE: To assess the clinical feasibility of spiral 3D Time-Of-Flight (TOF) MR Angiography (MRA) sequence variants for rapid non-contrast carotid artery imaging. METHODS: Nine different 3D TOF MRA sequences were acquired in nine healthy volunteers on a standard clinical 1.5 T scanner. Three cartesian sequences (fully sampled (10:15 min), accelerated with SENSE (05:08 min), accelerated with Compressed SENSE (03:32 min)) and six different spiral sequences were acquired (spiral acquisition windows ranging from 10 to 5 ms (01:32 min-03:05 min)). Three readers graded the images qualitatively in terms of overall image quality, vessel sharpness, inhomogeneous intraluminal signal, background noise, visualization of large and small vessels and overall impression of the number of visible vessels. Cross-sectional areas of the vessel lumen were measured and vessel sharpness was quantified. RESULTS: The SENSE and Compressed SENSE accelerated cartesian sequences and the Spiral 6 ms and 5 ms sequences were deemed comparable to the fully sampled cartesian sequence in most qualitative categories (p > 0.05) based on exact binomial tests. The Spiral 6 ms and 5 ms sequences achieved a scan time reduction of 75.3% and 69.9% respectively compared to the fully sampled cartesian sequence. The spiral sequences (generally) exhibited improved subjective vessel sharpness (p < 0.01-p = 0.13) but increased background noise (p = 0.03-p = 0.25). Cross-sectional area measurements were similar between all sequences (Krippendorff's alpha: 0.955-0.982). Quantitative vessel sharpness was increased for all spiral sequences compared to all cartesian sequences (p = 0.004). CONCLUSIONS: Spiral 3D TOF MRA sequences with a spiral acquisition window of 5 ms or 6 ms may be used for accurate, rapid, clinical non-contrast carotid artery imaging.


Assuntos
Imageamento Tridimensional , Angiografia por Ressonância Magnética , Artérias Carótidas/diagnóstico por imagem , Estudos de Viabilidade , Voluntários Saudáveis , Humanos
12.
Acad Radiol ; 29(2): 269-276, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33158702

RESUMO

OBJECTIVES: Acoustic noise emission from MRI scanners is considered a major factor of patient discomfort during routine MRI examinations. We prospectively evaluated the impact of acoustic noise reduction using software implementations in routine clinical MRI on subjective patient experience and image quality. METHODS: Two-hundred consecutive patients undergoing one of four MRI examinations (brain, lumbar spine, shoulder, and knee) at a single center were prospectively randomized into two groups at a 1 to 1 ratio: standard MRI examination and MRI examination with acoustic noise reduction. After the examination, patients were asked to complete a questionnaire aimed at defining their subjective experience (primary endpoint). Two readers assessed subjective image quality of all patient studies in consensus (secondary endpoint). Nonparametric tests and logistic regression models were used for statistical analysis. RESULTS: Hundred-seventy-four patients were included in the final study. Patients in the intervention group felt less discomforted by the acoustic noise (p = 0.01) and reported increased audibility of music through the headphones (p = 0.03). No significant difference in subjective image quality was found. CONCLUSION: Our study indicates that the effects of acoustic noise reduction in routine clinical MRI can be translated into reduced patient discomfort from acoustic noise and improved audibility of music. Acoustic noise reduction thus significantly contributes to increased patient comfort during MRI examinations.


Assuntos
Acústica , Imageamento por Ressonância Magnética , Humanos , Ruído , Avaliação de Resultados da Assistência ao Paciente , Razão Sinal-Ruído
13.
Am J Physiol Regul Integr Comp Physiol ; 301(1): R60-6, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21490367

RESUMO

In this study, we examined whether glycemic status influences aerobic function in women with type 1 diabetes and whether aerobic function is reduced relative to healthy women. To this end, we compared several factors determining aerobic function of 29 young sedentary asymptomatic women (CON) with 9 women of similar age and activity level with type 1 diabetes [DIA, HbA1c range = 6.9-8.2%]. Calf muscle mitochondrial capacity was estimated by (31)P-magnetic resonance spectroscopy. Capillarization and muscle fiber oxidative enzyme activity were assessed from vastus lateralis and soleus muscle biopsies. Oxygen uptake and cardiac output were evaluated by ergospirometry and N(2)O/SF(6) rebreathing. Calf muscle mitochondrial capacity was not different between CON and DIA, as indicated by the identical calculated maximal rates of oxidative ATP synthesis [0.0307 (0.0070) vs. 0.0309 (0.0058) s(-1), P = 0.930]. Notably, HbA1c was negatively correlated with mitochondrial capacity in DIA (R(2) = 0.475, P = 0.040). Although HbA1c was negatively correlated with cardiac output (R(2) = 0.742, P = 0.013) in DIA, there was no difference between CON and DIA in maximal oxygen consumption [2.17 (0.34) vs. 2.21 (0.32) l/min, P = 0.764], cardiac output [12.1 (1.9) vs. 12.3 (1.8) l/min, P = 0.783], and endurance capacity [532 (212) vs. 471 (119) s, P = 0.475]. There was also no difference between the two groups either in the oxidative enzyme activity or capillary-to-fiber ratio. We conclude that mitochondrial capacity depends on HbA1c in untrained women with type 1 diabetes but is not reduced relative to untrained healthy women.


Assuntos
Glicemia/metabolismo , Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 1/fisiopatologia , Exercício Físico/fisiologia , Hemoglobinas Glicadas/metabolismo , Mitocôndrias Musculares/fisiologia , Adulto , Biópsia , Débito Cardíaco/fisiologia , Estudos de Casos e Controles , Feminino , Humanos , Músculo Esquelético/patologia , Músculo Esquelético/fisiologia , Oxigênio/sangue , Consumo de Oxigênio/fisiologia , Resistência Física/fisiologia
14.
J Magn Reson Imaging ; 33(3): 661-7, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21563250

RESUMO

PURPOSE: To evaluate in vivo MR imaging of the wrist at 3.0 Tesla (T) and 7.0T quantitatively and qualitatively. MATERIALS AND METHODS: To enable unbiased signal-to-noise ratio (SNR) comparisons, geometrically identical eight-channel receiver arrays were used at both field strengths. First, in vitro images of a phantom bottle were acquired at 3.0T and 7.0T to obtain an estimate of the maximum SNR gain that can be expected. MR images of the dominant wrist of 10 healthy volunteers were acquired at both field strengths. All measurements were done using the same sequence parameters. Quantitative SNR maps were calculated on a pixel-by-pixel basis and analyzed in several regions-of-interest. Furthermore, the images were qualitatively evaluated by two independent radiologists. RESULTS: The quantitative analysis showed SNR increases of up to 100% at 7.0T compared with 3.0T, with considerable variation between different anatomical structures. The qualitative analysis revealed no significant difference in the visualization of anatomical structures comparing 3.0T and 7.0T MR images (P>0.05). CONCLUSION: The presented results establish the SNR benefits of the transition from 3.0T to 7.0T for wrist imaging without bias by different array designs and based on exact, algebraic SNR quantification. The observed SNR increase nearly reaches expected values but varies greatly between different tissues. It does not necessarily improve the visibility of anatomic structures but adds valuable latitude for sequence optimization.


Assuntos
Imageamento por Ressonância Magnética/métodos , Articulação do Punho/patologia , Adulto , Artefatos , Cartilagem Articular/patologia , Desenho de Equipamento , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Imagens de Fantasmas , Punho/patologia
15.
Eur Radiol ; 21(9): 1979-87, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21533632

RESUMO

OBJECTIVE: To prospectively determine the diagnostic value of electrocardiography-triggered non-contrast-enhanced magnetic resonance angiography (TRANCE) of the lower extremities including the feet versus DSA. METHODS: All 43 patients with symptomatic peripheral arterial occlusive disease (PAOD) underwent TRANCE before DSA. Quality of MRA vessel depiction was rated by two independent radiologists on a 3-point scale. Arterial segments were graded for stenoses using a 4-point scale (grade 1: no stenosis; grade 2: moderate stenosis; grade 3: severe stenosis; grade 4: occlusion). Findings were compared with those of DSA. RESULTS: In the 731 vessel segments analysed, intra-arterial DSA revealed 283 stenoses: 33.6% moderate, 16.6% severe and 49.8% occlusions. TRANCE yielded a mean sensitivity, specificity, positive and negative predictive value and diagnostic accuracy to detect severe stenoses or occlusions of 95.6%, 97.4%, 87.2%, 99.2%, 97.1% for the thigh segments and 95.2%, 87.5%, 83.2%, 96.6%, 90.5% for the calf segments. Excellent overall image quality was observed for TRANCE in 91.4% versus 95.7% (DSA) for the thigh and in 60.7% versus 91.0% for the calves, while diagnostic quality of the pedal arteries was rated as insufficient. CONCLUSION: TRANCE achieves high diagnostic accuracy in the thigh and calf regions, whereas the pedal arteries showed limited quality.


Assuntos
Angiografia Digital/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Eletrocardiografia , Angiografia por Ressonância Magnética/métodos , Doença Arterial Periférica/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Idoso , Arteriopatias Oclusivas/fisiopatologia , Estudos de Coortes , Intervalos de Confiança , Meios de Contraste , Feminino , Humanos , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença
16.
Invest Radiol ; 56(8): 517-524, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33653993

RESUMO

OBJECTIVES: Pulse sequences with non-Cartesian k-space sampling enable improved imaging in anatomical areas with high degrees of motion artifacts. We analyzed a novel spiral 3-dimensional (3D) gradient echo (GRE) magnetic resonance imaging (MRI) sequence ("spiral," 114.7 ± 11 seconds) and compared it with a radial 3D GRE ("vane," 216.7 ± 2 seconds) and a conventional Cartesian 2D turbo spin echo (TSE) sequence ("TSE," 266.7 ± 82 seconds) for contrast-enhanced fat-suppressed T1-weighted spine imaging. MATERIALS AND METHODS: Forty consecutive patients referred for contrast-enhanced MRI were prospectively scanned with all 3 sequences. A qualitative analysis was performed by 3 readers using 4- or 5-point Likert scales to independently grade images in terms of overall image quality, occurrence of artifacts, lesion conspicuity, and conspicuity of nerve roots. The numbers of visible nerve roots per sequence and patient were counted in consensus. Coefficient of variation measurements were performed for the paravertebral musculature (CVPM) and the spinal cord (CVSC). RESULTS: Spiral (median [interquartile range], 5 [4-5]) exhibited improved overall image quality in comparison to TSE (3 [3-4]) and vane (4 [4-5]; both P < 0.001). Vane surpassed TSE in terms of overall image quality (P < 0.001). Spiral (4 [3.75-4]) and vane (3.5 [3-4]) presented with less artifacts than TSE (3 [2.75-3.25]; both P < 0.001). Spiral (4 [4-5]) outperformed vane (4 [3-5]; P = 0.01) and TSE (4 [3-4]; P = 0.04) in terms of lesion conspicuity. Conspicuity of nerve roots was superior on spiral (3 [3-4]) and vane (4 [3-4]) when compared with TSE (1.5 [1-2]; both P < 0.001). Readers discerned significantly more nerve roots on spiral (4 [2.75-8]) and vane (4 [3.75-7.25]) images when compared with TSE (2 [0-4]; both P < 0.001). Interreader agreement ranged from moderate (α = 0.639) to almost perfect (α = 0.967). CVPM and CVSC were significantly lower on spiral as compared with vane and TSE (P < 0.001, P = 0.04). Vane exhibited lower CVPM and CVSC than TSE (P < 0.001, P = 0.01). CONCLUSIONS: A novel spiral 3D GRE sequence improves contrast-enhanced fat-suppressed T1-weighted spinal imaging qualitatively and quantitatively in comparison with a conventional Cartesian 2D TSE sequence and to a lesser extent with a radial 3D GRE sequence at shorter scan times.


Assuntos
Meios de Contraste , Imageamento Tridimensional , Artefatos , Humanos , Imageamento por Ressonância Magnética , Coluna Vertebral/diagnóstico por imagem
17.
Sci Rep ; 11(1): 5506, 2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33750899

RESUMO

We sought to evaluate the utility of radiomics for Amide Proton Transfer weighted (APTw) imaging by assessing its value in differentiating brain metastases from high- and low grade glial brain tumors. We retrospectively identified 48 treatment-naïve patients (10 WHO grade 2, 1 WHO grade 3, 10 WHO grade 4 primary glial brain tumors and 27 metastases) with either primary glial brain tumors or metastases who had undergone APTw MR imaging. After image analysis with radiomics feature extraction and post-processing, machine learning algorithms (multilayer perceptron machine learning algorithm; random forest classifier) with stratified tenfold cross validation were trained on features and were used to differentiate the brain neoplasms. The multilayer perceptron achieved an AUC of 0.836 (receiver operating characteristic curve) in differentiating primary glial brain tumors from metastases. The random forest classifier achieved an AUC of 0.868 in differentiating WHO grade 4 from WHO grade 2/3 primary glial brain tumors. For the differentiation of WHO grade 4 tumors from grade 2/3 tumors and metastases an average AUC of 0.797 was achieved. Our results indicate that the use of radiomics for APTw imaging is feasible and the differentiation of primary glial brain tumors from metastases is achievable with a high degree of accuracy.


Assuntos
Algoritmos , Neoplasias Encefálicas , Encéfalo , Glioma , Imageamento por Ressonância Magnética , Adulto , Idoso , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Feminino , Glioma/diagnóstico por imagem , Glioma/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica
18.
Sci Rep ; 11(1): 12000, 2021 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-34099833

RESUMO

In this paper we sought to develop and assess the reproducibility of an updated 6-point grading system for lumbar foraminal stenosis based on the widely used Lee classification that more accurately describes lumbar foraminal stenosis as seen on high-resolution MRI. Grade A indicates absence of foraminal stenosis. Grades B, C, D and E indicate presence of foraminal stenosis with contact of the nerve root with surrounding anatomical structures (on one, two, three or four sides for B, C, D and E respectively) yet without morphological change of the nerve root. To each grade, a number code indicating the location of contact between the nerve root and surrounding anatomical structure(s) is appended. 1, 2, 3 and 4 indicate contact of the nerve root at superior, posterior, inferior and anterior position of the borders of the lumbar foramen. Grade F indicates presence of foraminal stenosis with morphological change of the nerve root. Three readers graded the lumbar foramina of 101 consecutive patients using high-resolution T2w (and T1w) MR images with a spatial resolution of beyond 0.5 mm3. Interreader agreement was excellent (Cohen's Kappa = 0.866-1). Importantly, 30.6%/31.6%/32.2% (reader 1/reader 2/ reader 3) of foramina were assigned grades that did not appear in the original Lee grading system (grades B and D). The readers found no foramen that could not be described accurately with the updated grading system. Thus, an updated 6-point grading system for lumbar foraminal stenosis is reproducible and comprehensively describes lumbar foraminal stenosis as seen on high-resolution MRI.


Assuntos
Constrição Patológica/metabolismo , Região Lombossacral/anatomia & histologia , Estenose Espinal/metabolismo , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
19.
Br J Radiol ; 94(1121): 20200869, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33596102

RESUMO

OBJECTIVES: Diffusion-weighted imaging (DWI) plays a crucial role in the diagnosis of ischemic stroke. We assessed the value of computed and acquired high b-value DWI in comparison with conventional b = 1000 s mm-2 DWI for ischemic stroke at 3T. METHODS: We included 36 patients with acute ischemic stroke who presented with diffusion abnormalities on DWI performed within 24 h of symptom onset. B-values of 0, 500, 1000 and 2000 s mm-2 were acquired. Synthetic images with b-values of 1000, 1500, 2000 and 2500 s mm-2 were computed. Two readers compared synthetic (syn) and acquired (acq) b = 2000 s mm-2 images with acquired b = 1000 s mm-2 images in terms of lesion detection rate, image quality, presence of uncertain hyperintensities and lesion conspicuity. Readers also selected their preferred b-value. Contrast ratio (CR) measurements were performed. Non-parametrical statistical tests and weighted Cohens' κ tests were computed. RESULTS: Syn1000 and syn1500 matched acq1000 images in terms of lesion detection rate, image quality and presence of uncertain hyperintensities but presented with significantly improved lesion conspicuity (p < 0.01) and were frequently selected as preferred b-values. Acq2000 images exhibited a similar lesion detection rate and improved lesion conspicuity (p < 0.01) but worse image quality (p < 0.01) than acq1000 images. Syn2000 and syn2500 images performed significantly worse (p < 0.01) than acq1000 images in most or all categories. CR significantly increased with increasing b-values. CONCLUSION: Synthetic images at b = 1000 and 1500 s mm-2 and acquired DWI images at b = 2000 s mm-2 may be of clinical value due to improved lesion conspicuity. ADVANCES IN KNOWLEDGE: Synthetic b-values enable improved lesion conspicuity for DWI of ischemic stroke.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , AVC Isquêmico/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Imagem de Difusão por Ressonância Magnética/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Estudos Retrospectivos , Razão Sinal-Ruído , Incerteza
20.
Eur J Radiol Open ; 8: 100377, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34611530

RESUMO

PURPOSE: To investigate the diagnostic yield of low to ultra-high b-values for the differentiation of benign from malignant vertebral fractures using a state-of-the-art single-shot zonal-oblique-multislice spin-echo echo-planar diffusion-weighted imaging sequence (SShot ZOOM SE-EPI DWI). MATERIALS AND METHODS: 66 patients (34 malignant, 32 benign) were examined on 1.5 T MR scanners. ADC maps were generated from b-values of 0,400; 0,1000 and 0,2000s/mm2. ROIs were placed into the fracture of interest on ADC maps and trace images and into adjacent normal vertebral bodies on trace images. The ADC of fractures and the Signal-Intensity-Ratio (SIR) of fractures relative to normal vertebral bodies on trace images were considered quantitative metrics. The appearance of the fracture of interest was graded qualitatively as iso-, hypo-, or hyperintense relative to normal vertebrae. RESULTS: ADC achieved an area under the curve (AUC) of 0.785/0.698/0.592 for b = 0,400/0,1000/0,2000s/mm2 ADC maps respectively. SIR achieved an AUC of 0.841/0.919/0.917 for b = 400/1000/2000s/mm2 trace images respectively. In qualitative analyses, only b = 2000s/mm2 trace images were diagnostically valuable (sensitivity:1, specificity:0.794). Machine learning models incorporating all qualitative and quantitative metrics achieved an AUC of 0.95/0.98/0.98 for b-values of 400/1000/2000s/mm2 respectively. The model incorporating only qualitative metrics from b = 2000s/mm2 achieved an AUC of 0.97. CONCLUSION: By using quantitative and qualitative metrics from SShot ZOOM SE-EPI DWI, benign and malignant vertebral fractures can be differentiated with high diagnostic accuracy. Importantly qualitative analysis of ultra-high b-value images may suffice for differentiation as well.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA