Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
BMC Musculoskelet Disord ; 23(1): 991, 2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-36401224

RESUMO

BACKGROUND AND PURPOSE: Several surgical procedures are used to treat tuberculous kyphosis. However, the treatment of extreme spinal kyphosis is challenging, and associated with various complications. Halo traction has been used as an adjunctive method in the treatment of severe spinal deformities. However, there are few reports about the effectiveness of halo-pelvic traction (HPT) for the treatment of extreme spinal kyphosis secondary to tuberculosis. This study evaluated the effectiveness of halo-pelvic traction followed by a posterior-only approach correction in the treatment of severe spinal kyphosis secondary to tuberculosis. METHODS: The records of 19 patients with severe spinal kyphosis secondary to tuberculosis were retrospectively reviewed. All 19 patients were treated with a two-stage approach: HPT combined with posterior fusion surgery by a posterior-only approach. Radiographic parameters were measured and evaluated. America Spinal Injury Association grade (ASIA), Scoliosis Research Society outcome (SRS-22) score, and complications were also evaluated. RESULTS: There were 9 males and 10 females, with an average age of 29.7 years at the time of surgery. The average HPT duration was 10.4 weeks. The mean kyphosis angle decreased from 131.40 ± 10.7° pre-traction to 77.1 ± 7.4° post-traction (P < 0.01). The traction correction rate was 41.3%. The mean postoperative kyphosis angle was 65.7 ± 8.5°, and the surgical correction rate was 8.7%. Of the total correction, 82.6% was the result of HPT. At a mean follow-up of 26.5 months, the average kyphosis correction loss was 2.9°. The mean sagittal balance was 11.1 ± 45.2 mm before traction, - 25.0 ± 37.4 mm after traction, 7.0 ± 13 mm after surgery, and 2.8 ± 9.6 mm at the final follow-up. The mean preoperative SRS-22 score was 3.0 and postoperative was 4.2 (P < 0.01). The neurological status of most patients was improved. The total complication rate was 15.7%, including 1 neurological and 2 non-neurological complications. CONCLUSIONS: HPT is effective in the management of severe spinal kyphotic deformity secondary to tuberculosis. Preoperative HPT can greatly reduce global kyphosis, and the need for corpectomy.


Assuntos
Cifose , Anormalidades Musculoesqueléticas , Tuberculose da Coluna Vertebral , Humanos , Masculino , Feminino , Adulto , Tração/métodos , Estudos Retrospectivos , Resultado do Tratamento , Cifose/diagnóstico por imagem , Cifose/etiologia , Cifose/cirurgia , Tuberculose da Coluna Vertebral/complicações , Tuberculose da Coluna Vertebral/diagnóstico por imagem , Tuberculose da Coluna Vertebral/cirurgia
2.
BMC Musculoskelet Disord ; 23(1): 4, 2022 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-34980059

RESUMO

BACKGROUND: Finite element analyses and biomechanical tests have shown that PEEK rods promote fusion and prevent adjacent segment degeneration. The purpose of this study was to evaluate the effects and complications of hybrid surgery with PEEK rods in lumbar degenerative diseases. METHODS: From January 2015-December 2017, 28 patients who underwent lumbar posterior hybrid surgery with PEEK rods were included in the study. The patients were diagnosed with lumbar disc herniation, lumbar spinal stenosis, or degenerative grade I spondylolisthesis. Before the operation and at the last follow-up, the patients completed lumbar anteroposterior and lateral X-ray, dynamic X-ray, MRI examinations. In addition, at the last follow-up the patients also completed lumbar CT examinations. The radiographic parameters, clinical visual analog scale (VAS) score and Oswestry disability index (ODI) score were compared. RESULTS: The average age of the patients was 44.8 ± 12.6 years, and the average follow-up duration was 26.4 ± 3.6 months. The VAS score improved from 6.3 ± 1.6 to 1.0 ± 0.9, and the ODI score decreased from 38.4 ± 10.8 to 6.8 ± 4.6. The fusion rate of the fused segment was 100%. There were no significant changes in the modified Pfirrmann classifications or disc height index for the nonfused segments and the upper adjacent segments from pre- to postoperatively. No cases of screw loosening, broken screws, broken rods or other mechanical complications were found. CONCLUSION: Hybrid surgery with PEEK rods for lumbar degenerative diseases can yield good clinical results and effectively reduce the incidence of complications such as adjacent segment diseases.


Assuntos
Degeneração do Disco Intervertebral , Fusão Vertebral , Adulto , Benzofenonas , Seguimentos , Humanos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Pessoa de Meia-Idade , Polímeros , Estudos Retrospectivos , Fusão Vertebral/efeitos adversos , Resultado do Tratamento
3.
BMC Musculoskelet Disord ; 21(1): 665, 2020 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-33032558

RESUMO

BACKGROUND: Halo traction has been used as an adjunctive method in the treatment of severe spinal deformities. But there are few reports on the clinical efficacy of halo-pelvic traction (HPT) in the treatment of severe spinal deformities complicated with respiratory dysfunction. This study was to evaluate the clinical efficacy and complications associated with pre-operative HPT in the treatment of severe spinal deformities with respiratory dysfunction. METHODS: Thirty patients with severe spinal deformities complicated with respiratory dysfunction treated with short-term pre-operative HPT were retrospectively reviewed. Inclusion criteria were: (1) patients with severe kyphoscoliosis (coronal Cobb angle or kyphosis angle ≥100°) and respiratory failure, (2) patients undergoing HPT until posterior fusion surgery. All patients underwent general anesthesia for HPT application, which the pelvic ring used in this study was a half-ring, and the rods were all placed on the anterolateral side of the truck. RESULTS: The major coronal curve scoliosis averaged 116.00 ± 16.70° and was reduced to 63.23 ± 14.00° after HPT, 46.33 ± 10.70° after surgery. The major kyphosis was 102.40 ± 27.67° and was reduced to 52.23 ± 14.16° after HPT, 42.0 ± 11.92° after surgery. A significantly increased FVC was observed after HPT (p < 0.001), with a significantly improved FVC% (p < 0.001). Similarly, a significantly increased FEV1 was also observed (p < 0.001), with a significantly improved FEV1% (p < 0.001). CONCLUSION: This study indicated that the modified HPT could be used to help patients with severe spinal deformities complicated with respiratory dysfunction achieve significant correction in both the coronal and sagittal deformities during the pre-operative treatment period along with improved respiratory function and in the absence of severe complications.


Assuntos
Cifose , Escoliose , Fusão Vertebral , Humanos , Cifose/complicações , Cifose/diagnóstico por imagem , Cifose/cirurgia , Estudos Retrospectivos , Escoliose/complicações , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Fusão Vertebral/efeitos adversos , Tração , Resultado do Tratamento
4.
Front Bioeng Biotechnol ; 12: 1416046, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39055340

RESUMO

Introduction: Polyetheretherketone (PEEK) lumbar fusion rods have been successfully used in short-segment posterior instrumentation to prevent adjacent segment degeneration. However, limited studies have reported their application in lumbar long-segment instrumentation. This study aimed to compare the biomechanical performances of PEEK rods and titanium rods in lumbar long-segment instrumentation using finite element (FE) models, with the expectation of providing clinical guidance. Methods: A lumbar FE model (A) and four lumbar fixation FE models (BI, CI, BII, CII) of the L1-S1 vertebral body were developed using CT image segmentation (A: intact model; BI: intact model with L2-S1 PEEK rod internal fixation; CI: intact model with L2-S1 titanium rod internal fixation; BII: intact model with L3-S1 PEEK rod internal fixation; CII: intact model with L3-S1 titanium rod internal fixation). A 150-N preload was applied to the top surface of L1, similar to the intact model. The stresses on the lumbar intervertebral disc, facet joint, pedicle screws, and rods were calculated to evaluate the biomechanical effect of the different fixation procedures in lumbar long-segment instrumented surgery. Results: Under the four physiological motion states, the average stresses on the adjacent segment intervertebral disc and facet joint in all fixation models were greater than those in the intact model. Furthermore, the average stresses on the adjacent segment intervertebral disc and facet joint were greater in models CI and CII than in models BI and BII, respectively. The average stresses on the pedicle screws and rods were decreased in models BI and BII compared with models CI and CII under the four physiological motion states, respectively. Discussion: The PEEK rod internal fixation system may have better biomechanical properties than the titanium rod internal fixation system in delaying adjacent segment degeneration, improving the lumbar function of postoperative patients, and reducing the risk of screw loosening and breakage in lumbar long-segment instrumentation.

5.
Global Spine J ; : 21925682221126123, 2022 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-36112809

RESUMO

STUDY DESIGN: Retrospective radiological study. OBJECTIVES: Physical examination reveals sciatic scoliotic list (SSL) in some patients with lumbar disc herniation (LDH). We aimed to evaluate the coronal and sagittal parameters of the SSL curve, describe their characteristics, and establish a new classification system. METHODS: We retrospectively reviewed 230 patients (SSL group = 96; non-SSL group = 134) diagnosed with single-segment LDH from January 2018 to December 2020. The control group comprised 70 healthy volunteers. Radiographic parameters were compared between the groups. RESULTS: In the SSL group, the Cobb's angle was 12.5 ± 5.3° (4.2-31.2), trunk shift 26.2 ± 17.9 mm (.0-88.2 mm), and apical vertebral translation 31.7 ± 16.0 mm (1.18-8.58 mm). Further, 62.5% of patients had L4/5 disc herniation, 76.0% had disc herniation at the convex side of the lumbosacral scoliosis, and 81.3% had disc herniation at the opposite side of the trunk shift. Compared to the control group, lumbar lordosis and thoracic kyphosis decreased, pelvic tilt increased, and the sagittal vertical axis moved forward in the other patients. The sagittal imbalance in the SSL group exacerbated. Using the positional relationship between vertebrae and the central sacral vertical line (CSVL), we identified two main SSL patterns with which 95.8% of the patients were defined as Type 1. CONCLUSIONS: The SSL curve is characterized by a long thoracic or thoracolumbar curve, with a relatively straight sagittal profile and little rotation. Further, the lumbar and thoracic vertebrae shifts are on the same side as the CSVL. These features of the SSL curve differentiate it from other types of structural scoliosis.

6.
Front Neurol ; 13: 869230, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35547367

RESUMO

Background: Spinal muscular atrophy (SMA) is an autosomal recessive disorder caused by pathogenic variation of the survival motor neuron (SMN) 1 gene. Symptoms of SMA include progressive limb muscle weakness, atrophy, and severe scoliosis. Nusinersen is an antisense oligonucleotide that can enhance the production of the SMN protein. Here, we report a case with scoliosis who received orthopedic surgery combined with Nusinersen intrathecal injections. Case Presentation: Scoliosis orthopedic surgery followed by Nusinersen intrathecal injections was given to a 16-year-old girl who had thoracic and lumbar scoliosis and type 3 SMA. Surgery was performed for T3-S2 posterolateral fusion (PLF), with a channel left on the vertebral laminae of L3-L4. The balance of the spine and pelvis was significantly improved and the height increased by 9 cm. Lumbar puncture was conducted with local anesthesia under ultrasound and CT guidance through the laminae channel and Nusinersen was successfully injected. Comparing the two approaches, real-time ultrasound guidance for intrathecal Nusinersen injections after spinal surgery is preferred, however, CT guidance is an alternative if the initial puncture procedure is difficult. After the aforementioned multidisciplinary treatment, a good outcome was achieved, as demonstrated by a 2-point increase in RULM and MFM32 scores 2 months later. Conclusion: Scoliosis orthopedic surgery combined with Nusinersen intrathecal injection is an effective treatment for SMA patients with scoliosis.

7.
Nanoscale ; 11(9): 3896-3904, 2019 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-30758015

RESUMO

Graphene shows great promise for advanced filtration membranes with high permeance and enhanced rejection. Here we demonstrate filtration membranes with a nanochannel network for superior separation performance using 100-500 nm-wide graphene nanoplatelets (GnPs) that are efficiently prepared via a green method. The resulting membranes exhibit a well packed layer structure formed by GnPs and are highly stable in water and organic solvents and even in strongly acidic and alkaline media. Moreover, the GnP membranes possess high fluxes and good selectivity in both water and organic solvents based on the small size nanoplatelets and the stable nanochannels between the GnPs. The exfoliated GnPs and the subsequent membranes show great potential for practical applications in water purification and organic solvent filtration.

8.
ACS Appl Mater Interfaces ; 11(40): 37247-37255, 2019 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-31508934

RESUMO

Hexagonal boron nitride has displayed increased potential in heat dissipation applications due to its desirable high thermal conductivity and remarkable thermal stability. However, the large-yield and high-quality preparation of boron nitride nanosheets (BNNSs) has been still an enormous challenge. In present work, we developed a universal exfoliation strategy to synthesize few-layer and defect-free BNNSs, which involved the intercalation of hexafluorosilicates/sodium hydroxide into BN crystals followed by exfoliation through a mild stirring process. The yield and concentration of as-obtained BNNS reached up to 78.5% and 12.78 mg/mL, respectively. More importantly, this method has been proven to exfoliate other layered materials like graphene (G), MoS2, and WS2. These as-obtained BNNSs can be directly used for constructing freestanding papers with high thermal conductivities. Typically, the thermal conductivities of the BNNS-G hybrid paper were up to 63.5 W/mK along the in-plane direction and 7.4 W/mK along the through-plane direction. According to the thermal interface materials performance measures, BNNS-G hybrid paper shows great promising applications for heat transfer in integrated circuit packaging.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA